Tender For Development Of Tourism Infrastructure At Buddheswara Temple,Bhuban In Dhenkanal District

BOQ

Name of Work:- DEVELOPMENT OF TOURISM INFRASTRUCTURE AT BUDDHESWARA TEMPLE,BHUBAN IN DHENKANAL DISTRICT
Sl. No. Item Description
1Construction of New Half Height Boundary Wall
2Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutt
3Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by
4Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
5Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
6Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings, to be mixed in concrete mixture including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing fo
7Footing
8Column
9Tie Beam
10Cwall Top Beam
11Providing, fixing and placing of Tor steel (HYSD) Fe-500 IS 1786-2008 for RCC work in all floors of required diameter of approved quality with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills
12First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after im
1312mm cement plaster on external RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
14Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
15Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engi
16Construction of Pathway Paving
17Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutt
18Filling Foundation and plinth with avelable excavated Earth including leveling and watering, all labour and matrials complete.
19Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
20Construction of granular sub-base by providing close graded granular sub base Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, & compacting wit
21Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
22Supplying & Fixing of Pre Cast Kerb Stone of Size 600mm X 300 X 150mm OF m-30 GRADE OF approved MAKE, DESIGN, COLOUR AND SIZE MADE BY Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:
23Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete.
24Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50m
25Construction of Temple Premises Flooring
26Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutt
27Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by
28Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
29Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
30Providing and fixing 16mm thick Marble stone Flooring/Skirting (sample of Marble stone should be approved by Engineer-In-Charge) for Temple premises and similar locations where ever required in horizontal/vertical surfaces of required size of approved s
31Construction of New Gate Complex
32Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutt
33Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by
34Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
35Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
36Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings, to be mixed in concrete mixture including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing fo
37Footing
38Column
39Tie Beam
40Roof Beam
41Providing, fixing and placing of Tor steel (HYSD) Fe-500 IS 1786-2008 for RCC work in all floors of required diameter of approved quality with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills
42First class Fly ash Brick masonry using bricks of size 25cm. x 12cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after imm
43First class Fly ash Brick masonry using bricks of size 25cm. x 12cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after imm
4412mm cement plaster on external RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
45DEVELOPMENT OF TOURISM INFRASTRUCTURE AT BUDHESWAR TEMPLE ,(Retaining Wall)BHUBAN IN DHENKANAL DISTRICT
46Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutt
47Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp.
48Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
49Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
50Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings, to be mixed in concrete mixture including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing fo
51Footing
52Retaining Wall
53Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be u
54Rough Stone Dry Packing is approns and revetments with hard Granite Stone of 30cm and above size
55Grouting approns and revetment 23cm deep with cement concrete (1:4:8) with 2.5cm broken granite metal
56Supplying and filling Moorum in Stone pitching Slope gap including watering, compacting, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-in-charge.
57Renovation of Open Dining Space
58Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutt
59Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by
60Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
61Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
62Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings, to be mixed in concrete mixture including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing fo
63Footing
64Column
65Tie Beam
66roofBeam
67Providing, fixing and placing of Tor steel (HYSD) Fe-500 IS 1786-2008 for RCC work in all floors of required diameter of approved quality with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills
68First class Fly ash Brick masonry using bricks of size 25cm. x 12cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after imm
69First class Fly ash Brick masonry using bricks of size 25cm. x 12cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after imm
7012mm cement plaster on external RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
7116mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
726 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
73Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand
74Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume
75Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet Floor and similar locations where ever required in horizontal/vertical surfaces of required si
76Providing and fixing 20mm thick Granite stone Skirting (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet wall/dado and similar locations where ever required in horizontal/vertical surfaces of required
77Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
78Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engi
79Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of mix 1:2:4(1cement:2sand:4graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab
80Demolition of Existing Structures BoundaryWall,Temple Kitchen,pind & Community Kitchen
81Dismantling brick or stone masonry in lime or cement mortar under 3m. height including stacking the useful materials for reuse and removing the debris within 50m. Lead
82Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead
83Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead
84Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead.
85Dismantling and removing old cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead.
86Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead.
87Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of he materials for reuse and removing the debris within 50m lead.
88Construction of NEW TEMPLE KITCHEN
89Earth work in hard soil or gravelly soil with in 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7 cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge.
90Supplying and back filling over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-in-charge.
91Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-in-charge.
92Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
93Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 20 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
94Footing
95Column
96Plinth Beam
97Lintel
98Chajja
99Roof Slab
100Roof Beam
101Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding ( Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-in-charge Cold Twisted bars, Thermo-Mechanically-treated bars.
102First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
103First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
1046 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
105Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand
106Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume
107Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet Floor and similar locations where ever required in horizontal/vertical surfaces of required si
108Providing and fixing 20mm thick Granite stone Skirting (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet wall/dado and similar locations where ever required in horizontal/vertical surfaces of required
109Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
110Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engi
111Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of mix 1:2:4(1cement:2sand:4graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab
1126 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
113Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand
114Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume
115Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet Floor and similar locations where ever required in horizontal/vertical surfaces of required si
116Providing and fixing 20mm thick Granite stone Skirting (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet wall/dado and similar locations where ever required in horizontal/vertical surfaces of required
117Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
118Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engi
119Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of mix 1:2:4(1cement:2sand:4graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab
120Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engi
121Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of mix 1:2:4(1cement:2sand:4graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab
122Construction of Handwash,Footwash Point & Shoe Stand
123Earth work in Stoney earth soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the earth transported by transport vehicles as directed by the Engineer-In-charge.
124Excavation of founation in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department
125Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge.
126Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
127First class Fly ash Brick masonry using bricks of size 25cm. x 12cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
128First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
129Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 20 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
130Footing
131Column
132Plinth Beam
133Roof Beam
134Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-in-charge Cold Twisted bars, Thermo-Mechanically-treated bars.
13512mm cement plaster on external RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
13616mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
1376 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
138Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
139Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete.
140Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
141Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge.
142Providing and fixing M.S grill/Shutter/Gate of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply).
143Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete.
144Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by Engineer-In-Charge) for Floor & similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
145Providing and fixing 20mm thick Granite stone Skirting (sample of Granite stone should be approved by Engineer-In-Charge) for wall & similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
146Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of mix 1:2:4(1cement:2sand:4graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-in-charge prior to material procurement by the contractor.
147Electrical Estimate for Development of Tourism Infrastructure at Budheswar Temple,Bhuban
148E.I. WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/RR KABLE/ KEI with 20 mm dia HMS FRLS PVCconduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
149GROUP-A
150GROUP-B
151GROUP-C
152Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
153Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
154Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
155Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC /Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
156Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak /Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
157Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
158Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
159S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
160S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
161Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
162Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.
163Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
164SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
165Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
166Supply and fixing of 6 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator).Warranty on DB is 3 years
167Supplying and fixing 6-32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
168Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
169Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
170Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
171Providing and fixing 6swg GI wire on surface or in recess for loop earthing as required.
172Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
173supply of 4core x 16 sq mm Aluminium Armoured cable, complete with all accessories as requirement at site, including cost & conveyance of all materials labours all taxes etc. (make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster )
174LAYING OF CABLE
175Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
176Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
177Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster )
178PANELS
179S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer-1-01 number of 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.In commer-2- 01 number of 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Changeover- 01 no of 125A 4P onload changeover switch (50 KVA DG 01 NO)(Make-HPL/L&T/Siemens/Schneider).
180S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING MAIN)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer-1-01 number of 63A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Busbar-1&2 04 numbers of 100Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 22 numbers of 6-32A 2P MCB10KA,C series with space for 1PH KWH meter ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) . Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication.
181S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic coverPanasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj (5Years Warranty)
182Supply of 6 mtr long hot dip Galvanized PU Painted Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
183Supply of 6 mtr long hot dip Galvanized PU Painted Octagonal pole manufactured from HT steel(DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
184Supplying ,installation & fixing of Waterproof DMX Connectors for Light Fixture Similar to Philips/Leksa/Canara Lighting lightingincluding installation under water( with GI jalli cover)as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Warranty shall be of 5 years.
185Screened 4 core sheilded DMX signal cable for DMX network.
186S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by Simens Gray powder cote paint is desgined as G>A drawing.(FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer ,AUTO MANUAL (with start and stop push button) SELECTOR 63 A 3P contractor,OLR,RYB,ON,OFF trip indication,Type-II SPD 40ka,,04 nos 10A 4P MCB,C,10KA as outgoing MCB(Make-LEGRAND-DX3/Siemens-Betaguard/Schneider- Acti 9/ABB SB 200) as per direction of Engg-in-Charge.Necessary test report & warranty certificate to be submitted to the department for genuinity of product & to avail free after Sales service within warranty period 1 years of acceptance of materials
187Construction of \\"Internal & External P.H & Sanitary work\\"
188P.H WorkSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast)
18920mm Dia CPVC Pipe
19025mm Dia CPVC pipe
19125 mm dia PVC ASTM (Sch-80) pipe
19232 mm dia PVC ASTM (Sch-80) pipe
19340mm dia PVC ASTM (Sch-80) pipe
19450mm dia PVC ASTM (Sch-80) pipe
195Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm Thick Wall
196Ground Floor
197Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
198in ground Floor
199Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
200Ground Floor
201Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge.
20215mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN
20315mm dia CP S.B Bib cock (CON-CHR-037KN)
20420mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN
20515mm dia CP angle stop cock (FLR-ACR-5053N)
20615mm dia CP Pillar cock (Jaquar)CON-CHR-021KN
20715mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN
20832mm Full Thread Waste Coupl. (Jaquar) ALD-CHR-705
209450mm Braided hoses (Jaquar- ALD-CHR-805B)
21025mm dia brass or gun metal full way valve(shakti make)
21132mm dia brass or gun metal full way valve(shakti make)
21240mm dia brass or gun metal full way valve(shakti make)
21350mm dia brass or gun metal full way valve(shakti make)
21415mm dia CP Flange
21515mm dia CP Extention Nipple
216125mm CP grating
217Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) (3 layer)on the roof of Ground floor
218Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor(Supreme/Ashirvad/Oriplast)
219110mm dia U-PVC SWR pipe
22075 mm dia UPVC SWR Pipe
221110mm U-PVC door tee
222110mm U-PVC Plain tee
223110mm U-PVC door bend
224110mm U-PVC plain bend
225110mm dia U-PVC 'P' trap
226110mm dia U-PVC Plain Shoe Bend
227110mm dia U-PVC offset with out ear
228110mm dia U-PVC cowl
22975 mm dia UPVC plain bend Pipe (supreme/ashirvad)
23076 mm dia UPVC plain Tee Pipe (supreme/ashirvad)
231PVC clamp suitable for 75 mm to 110mm dia pipe
232Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall
233Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. Under counter basin(Hindware)No.10095+ALD-CHR-709+ALD-CHR-803AB+KUB-CHR-35001F
234Jaquar wall hung Wash Basinmodel FNS-WHT-40801 and Half Pedestal Model FNS-WHT-40305,
235Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail(Jaquar make-AHS-CHR-1501)
236CP Towel Ring (Jaquar) ACN-CHR-1121N
237Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge. CP soap holder
238Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge. 600mmx125mm size glass shelf with C.P gruard rail(Jaquar-ACN-CHR-1171N)
239Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Design Mirror(Parryware)
240Supplying all materials, labour, T&P and providing fitting and fixing Aquaguard PRO Thermapure 120 PSS RO ACH which gives you Hot,Cold & Ambient purified water.Aquaguard PEO Thermapure 120 PSS RO has built-in-3 stage combinations,Tank Capacity 120Ltr.,Cold Water-80 Ltrs,Hot water-20 Ltrs.,Ambient water-2- Ltrs.,Cooling capacity-60 LPH,Refrigerant-HFC R134a,Cold water temperature-15 Deg.C+/-1*,Heating coil wattage-2000W,Hot water temperature-50 Deg C+/-1,Thermal insulation-PUF,No of Faucets-1 Hot,1 Cold,1 Ambient,Tank,front panel and drain tray MOC-SS304,Other body panels-Powder coated CRCA Steel,No of filtration stages-7,RO Capacity-50 LPH*,RORecovery%-50%*,TDS Reject-90%*,Dimentions(WxDxH)cm-75x72x144,Net weight-92 Kg.etc.all complete as per direction of the Engineer-in-charge.
241Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
242Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
243Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
244Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
245Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
246110mm dia U-PVC Alround Concrete Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57315303
AUTHORITY Local Bodies
TENDER VALUE 1.37 Crore
LAST DATE 19-09-2026
Authority
Authority Name zilla parishad
Work Description Tender For Development Of Tourism Infrastructure At Buddheswara Temple,Bhuban In Dhenkanal District
Basic Detail
Tender No Online BHUBAN03/2026-27
Bidding Type Tender
Location
City Dhenkanal
State Odisha
Key Dates
Publish Date 02 Sep 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 1.37 Crore
Tender Fee 10000
EMD 1.37 Lakhs
Exemption Available
Document List
5796af75-c688-4f91-9ed5-bf7b6e30a112.html
BOQ_607843.xls
Tendernotice_1 (14).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

5796af75-c688-4f91-9ed5-bf7b6e30a112.html

xls

BOQ_607843.xls

pdf

Tendernotice_1 (14).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders