Housing Urban and Rular Development Government Departments Closing in 7 days TDR #57314697

Tender For annual repair maintenance Of E & M Services At Vidhan Sabha Speaker / Mla Office Along With Waiting Room, Toilet At Delhi Jal Board At Rajapur Store Plot, Saector-9, Rohini, Delhi. (Sh: - Electrical Work))

Issued by Government Departments · Delhi, Delhi
Tender Value
20.95 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
7 days left
EMD
41903
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for annual repair maintenance Of E & M Services At Vidhan Sabha Speaker / Mla Office Along With Waiting Room, Toilet At Delhi Jal Board At Rajapur Store Plot, Saector-9, Rohini, Delhi. (Sh: - Electrical Work))

BOQ

Name of Work:- ARMO of E & M Services at Vidhan Sabha speaker / MLA office along with Waiting room, toilet at Delhi Jal board at Rajapur Store Plot, Saector-9, Rohini, Delhi. (SH: - Electrical Work))
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group C
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.a) Group C
3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 x 1.5 sq. mm
4b) 3 x 4 sq. mm
5Wiring for light/ power plug with 2X4 sq.mmFRLS/HFFR PVC insulated copper conductor singlecore cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing asrequired.
6Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
7b) 25 mm
8Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 A switch
9b) 3 pin 5/6 A socket outlet
10c) 15/16 A switch
11d) 6 pin 15/16 A socket outlet
12e) 15 Amp 3 Pin plug Top (ISI Marked)
13Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 6 Module (200mmX75mm)
14b) 12 Module (200mmX150mm)
15Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modularsocket outlet and 5/6 A modular switch, connectionsetc. as required
16Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch,connections etc. as required.
17Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 2 nos. 3 pin 5/6 Amodular socket outlet and 2 nos. 5/6 A modularswitch, connections etc. as required.
18Supplying & fixing suitable size GI box with modularplate and cover in front on surface or in recessincluding providing and fixing 25 A modular socketoutlet and 25 A modular SP MCB, \\"C\\" curve includingconnections, painting etc. as required.
19Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 16 way, Double door
20Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 6 way (4 + 18), Double door
21Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole
22b) Single pole and neutral
23Providing and fixing following rating and breaking capacity and pole MCCB/TPN/SPN MCB with thermomagnetic release and terminal spreaders & associated switchgears in the above cubical panel board/TPDB including drilling holes in cubicle panel, fitting strips for MCB ,making connections, etc. as required.a) 100 A TP&N
24Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi core cable in then existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 core 2.5 sq. mm
25Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
26Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
27Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
28LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 36 watt
29LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 36 watt
30LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.a) 18 watt
31LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 100 watt
32b) 150 watt
33LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, interna surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/4000°K/5700°K/6500°K(As per ANSBin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 72 watt
34b) 120 watt
35Supplying and fixing hot press moulded SMC box (sintex) of size 250mmx200mmx105mm i/c s/f neutral link sp mcb 0-32 amp on the existing pole /on the wall surface or recess repairing etc as reqd.
36Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd. a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
37SITC of wall fan 400 mm sweep oscillating type having plastic blade complete with all accessories such as front jaali i/c connection etc. as reqd.
38Supplying & fixing of 300/305 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. As reqd.
39Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as required. a) size 3 X 10 sq. mm
40b) size 4 X 16 sq. mm
41Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size in DWC/HDPE/ RCC/ HUME/METAL as required. a) size 4 X 16 sq. mm
42Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE al. conductor cable of 1.1 kV grade as reqd. a) 3 X 10 sq. mm (22mm)
43b) 4 X 16 sq. mm (28mm)
44Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
45Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
46Supplying, Installation, Testing & Commissioning of 75” Crystal 4K UHD Smart LED TV having resolution minimum 3840 X 2160,Audio-Dolby Digital plus, speaker type 2CH,Multi voice assistance, app casting, cloud serviceMicrosoft 365,Dongle compatible, Digital Brodcasting-DVBT2,HDMI-3, including company supplied bracket on wall complete etc as reqd.
47New Generation IP65 LED, 40 Watt post top family, energy saving, enviromental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform ilumination for different applications etc. as required at site.
48Supply, Installation, Testing and Commissioning of SS body Water Cooler with 80 Litre water storage capacity and 60 Litre per hour Cooling capacity; suitable for operation on 230 V AC ,50 HZ, 1 phase having Refrigerant R-134A, reciprocating type compressor with condensing tube of Grooved Copper. The storage tank material should be SS 202, The product have faucet material of Brass (chrome plated) with water inlet & outlet hose pipes as required. The Company is having their NABL Accredited Lab Testing facilities in Delhi. The Product is ISO 9001 and Indian Medical Association Certified , GC (Green Company) Mark and BIS certificate, ISO9001.
49SITC of Reverse Osmosis(RO) System of 50 LPH along with Pre Filter Bowl set of 20” designed for Treatment of saline water in the TDS range of 500-2000 ppm having 7-stage purification having Particulate Filter Membrane Life Enhancer-Sediment Filter Pre Carbon Filter- RO Membrane-Post Carbon Filter-UV Lamp. The unit has body of CRCA Powder Coated. The TDS Rejection is 90% along with 50% Purified Water Recovery etc as required.
50Supplying, Installation, Testing and Commissioning of Wall Mounted RO Water Purifier with RO+UF+TDS Control Technology. Equiped With RO Mineral Technology that retain essential natural minerals in the purified water. With storage capacity of 8 Ltr., Made of ABS Food Grade Plastic, Purification production rate 20 Lph i/c all accessories and connections etc. as reqd.
51SITC of 1 HP Monoblock Pumpset having head range 12-28 Mtr. At a discharge range of 85-38 LPM , interconnection testing etc. complete as required.
52Supplying & fixing of Mandatory starter control panel for motor up to 3 HP single phase consisting of Single phase starter, Starting & Running capacitor, Ammeter, voltmeter, Push buttons, complete etc. as reqd.
53Supply and fixing of following ABC type fire extinguisher (ISI marked MAP 90%) complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd.a) 6 kg capacity ABC type fire extinguisher (ISI)
54Supply and fixing of 4.5 kg. capacity CO2 type fire extinguisher (ISI) marked complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd
55Supplying , Installation, Testing and Commissioning of AirCooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU toODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase ACsupply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB). Must comply : Electricalcable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as perCPWD specification and IS : 1391 Part II 2023. The systemshall be able to operate up to 50 0C (out door ambienttemperature).a) 1.5 TR with 5 Star BEE Rating
56Supplying &Fixing of 4 KVA capacity automatic voltage stabilizer with time delay relay and high/low\ voltage trip facility input voltage 150V to 290V and output voltage 220+10% with copper flexible cable connection etc. as required at site.
57Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
58b) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
59Providing, laying, fixing, and commissioning of PVC (Polyvinyl Chloride) drain pipe for Air Conditioning units, including all necessary fittings such as elbows, tees, reducers, clamps, supports, adhesives, and accessories as required.
60Supplying, Installation, Testing & Commissioning of Water dispenser (with water storing bottle ) suitable for operation 230-240 Volt 50 Hz AC supply having heating and cooling capacity of minimum 3 litre/hour with storage compartment , auto shut off and capable of dispensing hot, normal and cold water etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57314697
AUTHORITY Government Departments
TENDER VALUE 20.95 Lakhs
LAST DATE 10-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for annual repair maintenance Of E & M Services At Vidhan Sabha Speaker / Mla Office Along With Waiting Room, Toilet At Delhi Jal Board At Rajapur Store Plot, Saector-9, Rohini, Delhi. (Sh: - Electrical Work))
Basic Detail
Tender No 51/EE(E)/NWED/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 02 Sep 2026
Submission Date 10 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 20.95 Lakhs
Tender Fee Ref. Documents
EMD 41903
Exemption Available
Document List
b0d8fb77-a228-44b0-bef4-10c07dbfddfa.html
BOQ_396984.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b0d8fb77-a228-44b0-bef4-10c07dbfddfa.html

xls

BOQ_396984.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender