Tender For Construction Of Multi Storyed Parking At Bahu Fort Gorkha Nagar Ward No 48.
Tender Value
3.88 Crore
Estimated cost
Bid Submission
22 Sep 2026
7 days left
EMD
7.76 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Multi Storyed Parking At Bahu Fort Gorkha Nagar Ward No 48.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in all kind of soil. |
| 2 | Extra for every additional lift of 1.5 M or part therefore in all kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed. |
| 4 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work upto plinth level. |
| 5 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement,including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work above plinth level upto floor V level. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 7 | Providing and laying DPC 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and curing complete. |
| 8 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement : 6 fine sand). |
| 9 | Extra for brick work in super structure above plinth level upto floor V-level. |
| 10 | Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 11 | Extra for half brick work in super structure above plinth level upto floor V-level. |
| 12 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars. |
| 13 | 12mm thick cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand). |
| 14 | 12mm cement plaster of mix 1:6 (1 cement : 6 fine sand). |
| 15 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand). |
| 16 | Making of grove 12mm x 10mm between brick and RCC. |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. |
| 18 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete. |
| 19 | Add or deduct for plaster drip coarse / groove in plastered surface of moulding to RCC projections. |
| 20 | Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed. |
| 21 | Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form work for :-Foundations, footings, bases of columns. |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form work for :-Columns, pillars, piers. |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form work for :-Lintels, beams, plinth beams. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form work for :-Suspended floors, roofs, landings and access platforms. |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form work for :-Edges of slabs and breaks in floors and walls upto 20cm wide. |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form work for :-Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 28 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 mtr. of part thereof (Plan area to be measured). Suspended floors, roofs landing, beams and balconies (Plan area to be measured). |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) sal wood |
| 30 | Providing & fixing glazed shutters 35mm thick for doors, windows and clear story windows using 10Kg/Sqm (4mm thick) glass panes including stainless steel but hinges of size 75mm x 62mm x 2mm of make Kitch, Arch, Blum with necessary stainless screws in second class deodar wood. |
| 31 | Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauge of average width for aperture 1.4mm in both direction with wire of dia 0.63mm for doors, windows and clerestory windows with hinges and necessary screws in second class deodar wood. |
| 32 | Providing and fixing of glass panes weighing 12.50 kg/sqm (5.0mm thick) with deodar wood fillets. |
| 33 | Providing and fixing aluminium tower bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 150x10mm. |
| 34 | Providing and fixing aluminium handles ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 100mm. |
| 35 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter. |
| 36 | Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :-Coupler 110mm. |
| 37 | Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :Single tee with door 110 x 110 x 110mm. |
| 38 | Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :Bend 87.5* 110mm. |
| 39 | Providing 40x5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 40 | Applying priming coat with ready mixed pink or grey of primer of approved brand and manufacture on wood work (hard and soft wood). |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work (Wood work). |
| 42 | Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approve steel primer all complete (fixed to openings/wooden frames with rawl plugs, screws etc.). |
| 43 | Steel work welded in built-up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladders, railings, brackets, gates and similar work. |
| 44 | Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacture,over the plasterted wall surface to prepare the surface even and smooth complete |
| 45 | Finishing wall with acrylic smooth exterior paint of required shade on New work (two or more coats applied @ 1.67 litre/10 sqm over and including base coat of water proofing cement paint applied @ 2.20kg/10sqm) |
| 46 | Finishing walls with textured exterior paint of required shade on New work (two or more coats Rustic Regular of any colour as per Engg. incharge) over and including base coat of exterior primer applied @ 3.00kg/10sqm. |
| 47 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 48 | Providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. |
| 49 | Providing and fixing Glow studs of size 100x20mm made of heavy dutybody shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (Highimpact Polystyrene) or ABS having electronically welded micro-prismaticlens with abrasion resistant coating as approved by Engineer-in-charge.The Glow stud shall support a load of 13635 kg tested in accordance withASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5degrees to base. The reflective panels on both sides with at least 12cm ofreflective area up each side. The luminance intensity should be as per thespecification and shall be tested as described in ASTM I: 809 as recommended in BS : 873 part 4 : 1973. The studs shall be fixed to theroad surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction ofEngineer-in-charge. |
| 50 | Painting road surface marking with adequate no. of coats to give uniformfinish with read mixed road marking paint conforming to IS: 164, onbituminous surface in white/yellow shade including cleaning the surfaceof all dirt, scales, oil, grease and foreign material etc. complete.New work (Two or more coats) |
| 51 | Providing and fixing of rubber speeed breaker round top of size 500 x 400 x 75 mm including cost of material labour carriage etc Complete Job. |
| 52 | Supplying , Providing and Fixing rubber corner gaurd of length 1200 including cost of material ,labour,carriage etc.complete as per the direction of Engineer Incharge. |
| 53 | Providing ,Supplying and fixing of Rubber Wheel Gaurd of Superior quality (size 600x120x100)mm, weighing 3kg etc. Complete as per the direction of engineer incharge. |
| 54 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 55 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge 1:3:6 or richer mix (i/c equivalent design mix). |
| 56 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 57 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 58 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 59 | Disposal of Earth by Mechanical Transport Including Loading / Unloading and stacking at site as per the directioin of Engineer Incharge complete.lead upto 5 Km. |
| 60 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per the direction of Engineer-in-charge. |
| 61 | Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Sand for an average lead of 10 Kms. |
| 62 | Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Stone aggregate below 40mm size for an average lead of 10 Kms. |
| 63 | Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Stone aggregate 40mm and above 40mm size for an average lead of 5 Kms. |
| 64 | Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Bricks for an average lead of 30 Kms |
| 65 | Providing & fixing of white vitreous China pedestial type water closet (European Type) with cistern (A/PHAS-100 Cat No. 201100+Cat No. 21054 / Kerovit model No. 112 and flush tank model no. 1001) with CP bolts, nuts, CI chair hanging arrangements, bakelite seat & cover with CP hinges & rubber buffers, CP brass screw, washer with all accessories with WC connector with Rubber Lip / Buffer and side gap filled with silicon sealant wherever required. Including brass / SS screws and washer complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-in-charge. |
| 66 | Providing & fixing of white vitreous china wash basin with pedestal (Hindware Cat No. 1008 + Ped Cat No. 11003 / Kerovit model No. 234 Ped Model no. 305) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge. |
| 67 | Providing and fixing CP single liver extended basin mixer (height 85mm) without Popup waste system with 450mm long Braided Hoses and brass nuts with all fittings and accessories as per direction of Engineer-in-charge (Jaquar FUS 290238). |
| 68 | Providing & fixing C.P. hand spray with lever control (health faucet) (Jaquar Cat. No. ALDCHR-565 / Kerovit make KA580001) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge. |
| 69 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore (Make Jaquar CQT 23059 / Kerovit make Cat No. KB 1511003). |
| 70 | P/F of Soap Dish Holder with all fittings as per direction of Engineer-in-charge (Jaquar Cat No. ACN 113 N). |
| 71 | Providing and fixing 6mm copper backed float glass mirror MODI / SAINT-GOBAIN including 6mm thick BWR type ply board, 40mm stainless steel channel plugged to wall, hard wood treated with two coats of wood preservative, etc. all complete as specified and shown in drawing complete to the satisfaction of Engineer in charge. |
| 72 | Providing and fixing of glass shelf 600m long with all C.P fittings of approved quality complete item (Jaquar Cat No. ACN 11071 N). |
| 73 | Providing and fixing 15 mm dia. C.P. brass bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (Short Body) (Make Jaquar Cat No. CQT-23047) |
| 74 | Internal work:- Exposed on wallProviding and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.25mm dia. Nominal bore (Hot water supply) |
| 75 | Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.32mm dia. Nominal bore |
| 76 | Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.40mm dia. Nominal bore |
| 77 | Conceal Inside the walls:- Providing and fixing Conceled pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.20mm dia. Nominal bore |
| 78 | Providing and fixing Conceled pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall20mm dia. Nominal bore (Hot water supply) |
| 79 | External workProviding and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.20mm dia. Nominal bore |
| 80 | Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc25mm dia. Nominal bore |
| 81 | Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc32mm dia. Nominal bore |
| 82 | Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc40mm dia. Nominal bore |
| 83 | Supplying thermal insulation over hot pipes with 6mm thick \\"Kaiflex\\" or Careflex or approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 kg/m3 over pipes of following sizes including all required accessories complete as per manufacture's specifications and finishing it as per site requirement with cement plaster of 1:3 (1 cement: 3 coarse sand).20mm dia 9mm thickness |
| 84 | Supplying thermal insulation over hot pipes with 6mm thick \\"Kaiflex\\" or Careflex or approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 kg/m3 over pipes of following sizes including all required accessories complete as per manufacture's specifications and finishing it as per site requirement with cement plaster of 1:3 (1 cement: 3 coarse sand)25mm dia 9mm thickness |
| 85 | Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed. |
| 86 | Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75MM pipe |
| 87 | Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete110MM pipe |
| 88 | Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete160MM pipe |
| 89 | Construction brick measonery man hole in cement motor 1:4 (1 cement: 4 Coarse Sand) R.C.C top slab with 1:2:4 mix (1 cement: 2 Coarse Sand: 4 graded stone aggrigate 20 mm nominal size) foundation concrete aggrigate 40 mm Nominal Size, in side palstering 12mm thick with cement mortor 1:3 (1 cement:3 Coarse sand) finshed with floating coat near cement and making channels in cement concrete 1:2:4 (1 cement:2 Coarse snad:4 graded stone aggirgate 20mm nominal size) finished with floating coat of neat cement complete as per standard design. inside size 90cmx80cm and 45cm deep including cast iron cover with frame (light duty) 455x610mm internal dimensionals. total wt. of cover and frame to be not less than 38kg (wt. of cover 33kg and wt.of frame 15kg) with F.P.S bricks of class designation 75 (crush stone aggrigate) |
| 90 | Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. (With F.P.S. bricks) |
| 91 | Providing murum bedding below pipeline and filling on the top of the pipeline with selected material in 15 to 20 cm layers including watering ramming etc. complete. With selected earth available from excavation. |
| 92 | Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge. (Size 100 mm dia) (ISI Marked) |
| 93 | Providing and fixing heavy class SS grating plane including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge (Size 100 mm dia) (ISI Marked) |
| 94 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, Lotous or equivalent having valid ISI license). |
| 95 | Making soak pit 2.5m diameter 3.0 M deep with 45x45cm dry brick honey comb shaft with bricks of class designation 75mm and S.W. drain pipe 100mm diameter 1.8 m long complete as per standard design with FPS bricks. |
| 96 | Supply, assembly, erection, testing and commissioning of pumping system comprising the following:Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (wilo,ebara and matherplatt etc.) Pump Capacity 180 lpm, at 30 m head (1 working + 1 standby) (Domestic water relift pump). |
| 97 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 98 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 99 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/ Recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 100 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/ Recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 101 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 102 | supling and fixing of modular blank plateon the exsuisting modular oplate and switch box |
| 103 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 104 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 105 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)8 way (4 + 24), Double door |
| 106 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 107 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A F.P MCB 10 Ka \\"C\\" Curve |
| 108 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 109 | LED Batten light (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)40 watt |
| 110 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I /II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS /HFFR , PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120 watt |
| 111 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 112 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 113 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 114 | Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMERAdj.TMR Based MCCB 100 Amps FP=Icu=Icus=100% breaking capacity 36KAWITH EXTENDABLW ROH |
| 115 | upplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMER 200 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 116 | upplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMERDigital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 117 | Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMEROUTGOINGS Manual Changeover Switch 100 A F.P 415 Volts with AC-23 Duty |
| 118 | upplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMEROUTGOINGS F.P 63 A 10 Ka \\"C\\" Curve MCB |
| 119 | Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMEROUTGOINGS F.P 25 A 10 Ka \\"C\\" Curve MCB |
| 120 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 121 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.3.5 C X 25 Sq.mm A2XFY |
| 122 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 25 sq. mm (28mm) |
| 123 | 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery. |
| 124 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 125 | Supply,Installation of 3 Mtr 80 mm G.I Pole made of Galvanised Mild Steel Pipe Duly Painted with Two Coats of Primer and Aluminium Paint Including the Cost of Foundation |
| 126 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 127 | Supplying, installation, testing & commissioning of heatdetector operating at 54ºC/57ºC with rate of rise cum fixedtemperature (dual thermistor) type with mounting basecomplete with all connection etc. as required. |
| 128 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 129 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 130 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 2 x 1.5 sq. mm |
| 131 | Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.20MM PVC CONDUIT |
| 132 | Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMER |
| 133 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark (IS:15683 ) suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires |
| 134 | Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark (IS:15683) suitable for Class A/B/C Type Fires . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender