Public Administrative Department Local Bodies Closing in 7 days TDR #57314370

Tender For Construction Of Multi Storyed Parking At Bahu Fort Gorkha Nagar Ward No 48.

Issued by Local Bodies · Jammu, Jammu and Kashmir
Tender Value
3.88 Crore
Estimated cost
Bid Submission
22 Sep 2026
7 days left
EMD
7.76 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Multi Storyed Parking At Bahu Fort Gorkha Nagar Ward No 48.

BOQ

Name of Work:-
Sl. No. Item Description
1Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in all kind of soil.
2Extra for every additional lift of 1.5 M or part therefore in all kinds of soil.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed.
4Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work upto plinth level.
5Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement,including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work above plinth level upto floor V level.
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
7Providing and laying DPC 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and curing complete.
8Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement : 6 fine sand).
9Extra for brick work in super structure above plinth level upto floor V-level.
10Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand).
11Extra for half brick work in super structure above plinth level upto floor V-level.
12Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.
1312mm thick cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand).
1412mm cement plaster of mix 1:6 (1 cement : 6 fine sand).
1515mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand).
16Making of grove 12mm x 10mm between brick and RCC.
17Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M.
18Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete.
19Add or deduct for plaster drip coarse / groove in plastered surface of moulding to RCC projections.
20Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed.
21Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
22Centering and shuttering including strutting, propping etc. and removal of form work for :-Foundations, footings, bases of columns.
23Centering and shuttering including strutting, propping etc. and removal of form work for :-Columns, pillars, piers.
24Centering and shuttering including strutting, propping etc. and removal of form work for :-Lintels, beams, plinth beams.
25Centering and shuttering including strutting, propping etc. and removal of form work for :-Suspended floors, roofs, landings and access platforms.
26Centering and shuttering including strutting, propping etc. and removal of form work for :-Edges of slabs and breaks in floors and walls upto 20cm wide.
27Centering and shuttering including strutting, propping etc. and removal of form work for :-Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
28Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 mtr. of part thereof (Plan area to be measured). Suspended floors, roofs landing, beams and balconies (Plan area to be measured).
29Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) sal wood
30Providing & fixing glazed shutters 35mm thick for doors, windows and clear story windows using 10Kg/Sqm (4mm thick) glass panes including stainless steel but hinges of size 75mm x 62mm x 2mm of make Kitch, Arch, Blum with necessary stainless screws in second class deodar wood.
31Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauge of average width for aperture 1.4mm in both direction with wire of dia 0.63mm for doors, windows and clerestory windows with hinges and necessary screws in second class deodar wood.
32Providing and fixing of glass panes weighing 12.50 kg/sqm (5.0mm thick) with deodar wood fillets.
33Providing and fixing aluminium tower bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 150x10mm.
34Providing and fixing aluminium handles ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 100mm.
35Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter.
36Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :-Coupler 110mm.
37Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :Single tee with door 110 x 110 x 110mm.
38Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :Bend 87.5* 110mm.
39Providing 40x5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
40Applying priming coat with ready mixed pink or grey of primer of approved brand and manufacture on wood work (hard and soft wood).
41Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work (Wood work).
42Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approve steel primer all complete (fixed to openings/wooden frames with rawl plugs, screws etc.).
43Steel work welded in built-up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladders, railings, brackets, gates and similar work.
44Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacture,over the plasterted wall surface to prepare the surface even and smooth complete
45Finishing wall with acrylic smooth exterior paint of required shade on New work (two or more coats applied @ 1.67 litre/10 sqm over and including base coat of water proofing cement paint applied @ 2.20kg/10sqm)
46Finishing walls with textured exterior paint of required shade on New work (two or more coats Rustic Regular of any colour as per Engg. incharge) over and including base coat of exterior primer applied @ 3.00kg/10sqm.
47Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
48Providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
49Providing and fixing Glow studs of size 100x20mm made of heavy dutybody shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (Highimpact Polystyrene) or ABS having electronically welded micro-prismaticlens with abrasion resistant coating as approved by Engineer-in-charge.The Glow stud shall support a load of 13635 kg tested in accordance withASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5degrees to base. The reflective panels on both sides with at least 12cm ofreflective area up each side. The luminance intensity should be as per thespecification and shall be tested as described in ASTM I: 809 as recommended in BS : 873 part 4 : 1973. The studs shall be fixed to theroad surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction ofEngineer-in-charge.
50Painting road surface marking with adequate no. of coats to give uniformfinish with read mixed road marking paint conforming to IS: 164, onbituminous surface in white/yellow shade including cleaning the surfaceof all dirt, scales, oil, grease and foreign material etc. complete.New work (Two or more coats)
51Providing and fixing of rubber speeed breaker round top of size 500 x 400 x 75 mm including cost of material labour carriage etc Complete Job.
52Supplying , Providing and Fixing rubber corner gaurd of length 1200 including cost of material ,labour,carriage etc.complete as per the direction of Engineer Incharge.
53Providing ,Supplying and fixing of Rubber Wheel Gaurd of Superior quality (size 600x120x100)mm, weighing 3kg etc. Complete as per the direction of engineer incharge.
54Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)
55Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge 1:3:6 or richer mix (i/c equivalent design mix).
56Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
57Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
58Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
59Disposal of Earth by Mechanical Transport Including Loading / Unloading and stacking at site as per the directioin of Engineer Incharge complete.lead upto 5 Km.
60Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per the direction of Engineer-in-charge.
61Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Sand for an average lead of 10 Kms.
62Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Stone aggregate below 40mm size for an average lead of 10 Kms.
63Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Stone aggregate 40mm and above 40mm size for an average lead of 5 Kms.
64Carriage of material by Mechanical Transport including loading /unloading and stacking at site complete.Bricks for an average lead of 30 Kms
65Providing & fixing of white vitreous China pedestial type water closet (European Type) with cistern (A/PHAS-100 Cat No. 201100+Cat No. 21054 / Kerovit model No. 112 and flush tank model no. 1001) with CP bolts, nuts, CI chair hanging arrangements, bakelite seat & cover with CP hinges & rubber buffers, CP brass screw, washer with all accessories with WC connector with Rubber Lip / Buffer and side gap filled with silicon sealant wherever required. Including brass / SS screws and washer complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-in-charge.
66Providing & fixing of white vitreous china wash basin with pedestal (Hindware Cat No. 1008 + Ped Cat No. 11003 / Kerovit model No. 234 Ped Model no. 305) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge.
67Providing and fixing CP single liver extended basin mixer (height 85mm) without Popup waste system with 450mm long Braided Hoses and brass nuts with all fittings and accessories as per direction of Engineer-in-charge (Jaquar FUS 290238).
68Providing & fixing C.P. hand spray with lever control (health faucet) (Jaquar Cat. No. ALDCHR-565 / Kerovit make KA580001) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge.
69Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore (Make Jaquar CQT 23059 / Kerovit make Cat No. KB 1511003).
70P/F of Soap Dish Holder with all fittings as per direction of Engineer-in-charge (Jaquar Cat No. ACN 113 N).
71Providing and fixing 6mm copper backed float glass mirror MODI / SAINT-GOBAIN including 6mm thick BWR type ply board, 40mm stainless steel channel plugged to wall, hard wood treated with two coats of wood preservative, etc. all complete as specified and shown in drawing complete to the satisfaction of Engineer in charge.
72Providing and fixing of glass shelf 600m long with all C.P fittings of approved quality complete item (Jaquar Cat No. ACN 11071 N).
73Providing and fixing 15 mm dia. C.P. brass bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (Short Body) (Make Jaquar Cat No. CQT-23047)
74Internal work:- Exposed on wallProviding and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.25mm dia. Nominal bore (Hot water supply)
75Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.32mm dia. Nominal bore
76Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.40mm dia. Nominal bore
77Conceal Inside the walls:- Providing and fixing Conceled pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.20mm dia. Nominal bore
78Providing and fixing Conceled pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall20mm dia. Nominal bore (Hot water supply)
79External workProviding and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.20mm dia. Nominal bore
80Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc25mm dia. Nominal bore
81Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc32mm dia. Nominal bore
82Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc40mm dia. Nominal bore
83Supplying thermal insulation over hot pipes with 6mm thick \\"Kaiflex\\" or Careflex or approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 kg/m3 over pipes of following sizes including all required accessories complete as per manufacture's specifications and finishing it as per site requirement with cement plaster of 1:3 (1 cement: 3 coarse sand).20mm dia 9mm thickness
84Supplying thermal insulation over hot pipes with 6mm thick \\"Kaiflex\\" or Careflex or approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 kg/m3 over pipes of following sizes including all required accessories complete as per manufacture's specifications and finishing it as per site requirement with cement plaster of 1:3 (1 cement: 3 coarse sand)25mm dia 9mm thickness
85Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed.
86Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75MM pipe
87Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete110MM pipe
88Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete160MM pipe
89Construction brick measonery man hole in cement motor 1:4 (1 cement: 4 Coarse Sand) R.C.C top slab with 1:2:4 mix (1 cement: 2 Coarse Sand: 4 graded stone aggrigate 20 mm nominal size) foundation concrete aggrigate 40 mm Nominal Size, in side palstering 12mm thick with cement mortor 1:3 (1 cement:3 Coarse sand) finshed with floating coat near cement and making channels in cement concrete 1:2:4 (1 cement:2 Coarse snad:4 graded stone aggirgate 20mm nominal size) finished with floating coat of neat cement complete as per standard design. inside size 90cmx80cm and 45cm deep including cast iron cover with frame (light duty) 455x610mm internal dimensionals. total wt. of cover and frame to be not less than 38kg (wt. of cover 33kg and wt.of frame 15kg) with F.P.S bricks of class designation 75 (crush stone aggrigate)
90Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. (With F.P.S. bricks)
91Providing murum bedding below pipeline and filling on the top of the pipeline with selected material in 15 to 20 cm layers including watering ramming etc. complete. With selected earth available from excavation.
92Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge. (Size 100 mm dia) (ISI Marked)
93Providing and fixing heavy class SS grating plane including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge (Size 100 mm dia) (ISI Marked)
94Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, Lotous or equivalent having valid ISI license).
95Making soak pit 2.5m diameter 3.0 M deep with 45x45cm dry brick honey comb shaft with bricks of class designation 75mm and S.W. drain pipe 100mm diameter 1.8 m long complete as per standard design with FPS bricks.
96Supply, assembly, erection, testing and commissioning of pumping system comprising the following:Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (wilo,ebara and matherplatt etc.) Pump Capacity 180 lpm, at 30 m head (1 working + 1 standby) (Domestic water relift pump).
97Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
98Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
99Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/ Recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/ Recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
101Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
102supling and fixing of modular blank plateon the exsuisting modular oplate and switch box
103Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
104Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
105Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)8 way (4 + 24), Double door
106Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole
107Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A F.P MCB 10 Ka \\"C\\" Curve
108Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
109LED Batten light (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)40 watt
110LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I /II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS /HFFR , PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120 watt
111Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
112Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
113Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
114Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMERAdj.TMR Based MCCB 100 Amps FP=Icu=Icus=100% breaking capacity 36KAWITH EXTENDABLW ROH
115upplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMER 200 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
116upplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMERDigital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
117Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMEROUTGOINGS Manual Changeover Switch 100 A F.P 415 Volts with AC-23 Duty
118upplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMEROUTGOINGS F.P 63 A 10 Ka \\"C\\" Curve MCB
119Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMEROUTGOINGS F.P 25 A 10 Ka \\"C\\" Curve MCB
120Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
121Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.3.5 C X 25 Sq.mm A2XFY
122Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 25 sq. mm (28mm)
1232.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery.
124Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
125Supply,Installation of 3 Mtr 80 mm G.I Pole made of Galvanised Mild Steel Pipe Duly Painted with Two Coats of Primer and Aluminium Paint Including the Cost of Foundation
126Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set.
127Supplying, installation, testing & commissioning of heatdetector operating at 54ºC/57ºC with rate of rise cum fixedtemperature (dual thermistor) type with mounting basecomplete with all connection etc. as required.
128Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
129Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
130Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 2 x 1.5 sq. mm
131Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.20MM PVC CONDUIT
132Supplying,Installation,Testing and Commissioning of Cubical Type IndoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .INCOMER
133Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark (IS:15683 ) suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
134Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark (IS:15683) suitable for Class A/B/C Type Fires . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57314370
AUTHORITY Local Bodies
TENDER VALUE 3.88 Crore
LAST DATE 22-09-2026
Authority
Authority Name Jammu Municipal Corporation
Work Description Tender for Construction Of Multi Storyed Parking At Bahu Fort Gorkha Nagar Ward No 48.
Basic Detail
Tender No PWD(RB)DIV/JMC/51of 2026-27 Dated 2-096-2026
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 02 Sep 2026
Submission Date 22 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 3.88 Crore
Tender Fee 6000
EMD 7.76 Lakhs
Exemption Not Available
Document List
56751198-f123-4bea-9fe1-dac545425223.html
BOQ_1086981.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

56751198-f123-4bea-9fe1-dac545425223.html

xls

BOQ_1086981.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders