Housing Urban and Rular Development Government Departments Closing in 5 days TDR #57313842

Tender For Providing 125 Kva Silent Dg Gen Set For Swami Vivekanand Department (De-Addiction Centre) At Govt. Medical College At Amritsar.

Issued by Government Departments · Amritsar, Punjab
Tender Value
22 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
44006
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Providing 125 Kva Silent Dg Gen Set For Swami Vivekanand Department (De-Addiction Centre) At Govt. Medical College At Amritsar.

BOQ

Name of Work:- Providing 125 KVA Silent DG Gen Set For Swami Vivekanand Department (De-addiction Centre) at Govt. Medical College at Amritsar.
Sl. No. Item Description
1XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
2Overall size 150sq.mm (3½ Core) Armoured (Loose)
3DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
4Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)
5SHEET METAL IRON CLAD CHANGEOVER SWITCHES: Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:-
6IC Four Pole Changeover Switch 320amp., 415volts
7G.I. EARTHING: Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
8Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)
9G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc.
10Additional length G.I. rope 7/12 S.W.G. (7/2.80mm dia.) in 20mm dia. G.I. pipe (On Surface)
11COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
12Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
13COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
14Additional Length 20mm x 3mm thick Copper Tape
15Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 125 KVA / 100KW (Approx.).It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing 155 BHP (Min.) for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level, suitable self-starter for 12 V/ 24 V DC, battery charging alternator unit and voltage regulator, Lubrication oil cooler, Lubrication oil filters with replaceable elements.ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication, Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply.ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor: 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum dass insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.
16ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack. The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption. The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc. with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer-in-Charge at site. The model of engine will be decided by the Engineer in Charge.MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HR fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine. All the components in the control panel shall be properly mounted, duly wired and labeled.Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter, battery charger complete in all respect as desired by engineer at site:-
17Civil Work (Foundation of DG Set) Please Enable Macros to View BoQ information Compatibility Report for boq 125 kva. Run on 6/23/2026 10:44 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 'BoQ1'!A1:II33 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 19.0

AI Tender Summary

OUR REF NO 57313842
AUTHORITY Government Departments
TENDER VALUE 22 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing 125 Kva Silent Dg Gen Set For Swami Vivekanand Department (De-Addiction Centre) At Govt. Medical College At Amritsar.
Basic Detail
Tender No 16/2026-27 31-08-2029
Bidding Type Tender
Location
City Amritsar
State Punjab
Key Dates
Publish Date 02 Sep 2026
Submission Date 21 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 22 Lakhs
Tender Fee 5000
EMD 44006
Exemption Available
Document List
961efe17-eff6-4c45-99c9-9ca6bba6b0a6.html
BOQ_355564.xls
Tendernotice_1 (14).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

961efe17-eff6-4c45-99c9-9ca6bba6b0a6.html

xls

BOQ_355564.xls

pdf

Tendernotice_1 (14).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders