Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57312922

Tender For maintenance of electrical installation & Fan And Other Electrical Services In Pwd Offices Under Pwd Electrical Division South During 2026-27. (Sh- Miscellaneous Electrical Work At Chirag Delhi Civil Office Under South Electrical Maintenanc

Issued by Government Departments · Delhi, Delhi
Tender Value
5.88 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
6 days left
EMD
11769
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of electrical installation & Fan And Other Electrical Services In Pwd Offices Under Pwd Electrical Division South During 2026-27. (Sh- Miscellaneous Electrical Work At Chirag Delhi Civil Office Under South Electrical Maintenance Division)

BOQ

Name of Work:- MOEI & Fan and other electrical services in PWD Offices under PWD Electrical Division South during 2026-27. (SH- Miscellaneous Electrical work at Chirag Delhi Civil Office under South Electrical Maintenance Division)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group C
3Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
4Group C
5Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
63 x 1.5 sq. mm
73 x 4 sq. mm
83 x 6 sq. mm
9Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
102 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
112 X 4 sq. mm + 1 X 4 sq. mm earth wire
12Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1325 mm
14Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
15Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1612 way, Double door
17Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
184 way (4 + 12), Double door
19Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
20Single pole
21Single pole and neutral
22Supplying and fixing of following rating 63A Three Pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
24100 A, 16 KA,TPMCCB
25200 A,36KA,FPMCCB
26Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
273 Module (100mmX75mm)
286 Module (200mmX75mm)
2912 Module (200mmX150mm)
30Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
315/6 A switch
3215/16 A switch
333 pin 5/6 A socket outlet
346 pin 15/16 A socket outlet
35LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.).
36Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
3736 watt
38LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.).
39Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
4018- 22 Watt
41Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5,
42Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
43100 watt
44Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
451200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
46Supplying, installation, testing and commissioning of wall mounted cabin fan 400 mm sweep suitable for operating on 230 volt single phase AC supply i/c connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc complete as reqd.
47Supplying, installation, testing and commissioning of Heavy Duty 300mm sweep 900 RPM exhaust fan metal body complete with louvers/ shutters in the existing opening i/c making the hole to suit the size of the above fan making good the damage & connections with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and earth etc complete as reqd.
48Supplying, installation, testing and commissioning of Heavy Duty 450mm sweep 1400 RPM exhaust fan metal body complete with louvers/ shutters in the existing opening i/c cutting GI/MS Profile sheet, making the hole to suit the size of the above fan making good the damage & connections with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and earth etc complete as reqd.
49Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
50Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 kV grade of following size on wall surface as required.a) 3 x 10 sq.mm
51b) 4 x 25 sq.mm
52b) 4 x 16 sq.mm
53Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
54Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
55Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
56Lifting & Lowering Submersible Pump Set along with G.I. pipe upto 3 HP damage and defective pump set from existing UG sump or Borewell with the help of chain and pulley block i/c cartage from site to workshop as reqd.
57Supplying and fixing 3 x 4 sq.mm sizes flat copper conductor submersible PVC insulated PVC sheathed 1.1 KV grade cable i/c connection & testing etc. complete as reqd. (ISI marked).
58Providing and fixing of DOL motor starter suitable for upto 3 HP, Single phase pump set, SPP feature, voltmeter, ammeter, push button auto-manual on-off contractor with relay i/c less credit back old dismentled material etc complete as reqd
59Suppyling, Installation, Testing and commissioning S.M.C junction box 185x165x60 complete with terminal block suitable for 25 sq. mm conductor, DIN bar, SP MCB with suitable. M.S. clamp on the existing pole for light fixture etc as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57312922
AUTHORITY Government Departments
TENDER VALUE 5.88 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for maintenance of electrical installation & Fan And Other Electrical Services In Pwd Offices Under Pwd Electrical Division South During 2026-27. (Sh- Miscellaneous Electrical Work At Chirag Delhi Civil Office Under South Electrical Maintenance Division)
Basic Detail
Tender No 62/EE(E)/South /Elect. Divn.,/PWD/ 2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 02 Sep 2026
Submission Date 09 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value 5.88 Lakhs
Tender Fee Ref. Documents
EMD 11769
Exemption Available
Document List
61920bea-b6f3-4eee-bdac-3e56769897be.html
BOQ_396979.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

61920bea-b6f3-4eee-bdac-3e56769897be.html

xls

BOQ_396979.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender