Tender For Construction Of Shooting Range In Dr. Mahinder Kaur Sembhi Sen. Sec. Girls School At Faridkot
Tender Value
55.66 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
4 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Faridkot → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Shooting Range In Dr. Mahinder Kaur Sembhi Sen. Sec. Girls School At Faridkot
BOQ
| Sl. No. | Item Description |
| 1 | Civil work |
| 2 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres (34+63-97+5.35%=102 19) |
| 3 | Cement concrete 1:4:8 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 4 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 5 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at1.65 Kg per sqm laid hot and sanded |
| 6 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 7 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 8 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 9 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 10 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 11 | First class burnt brick laid in cement sand mortor 1:6 in foundation and plinth. |
| 12 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 13 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in1:4 cement mortar in superstructure |
| 14 | 12.5 mm thick cement plaster 1:5 |
| 15 | 20mm thick cement plaster 1:5 in two coat work |
| 16 | 12.5 mm thick cement plaster 1:4 |
| 17 | 20mm thick cement plaster 1:4 in two coat work |
| 18 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 19 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 20 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 21 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 22 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 23 | Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating (P.T.M.T.) |
| 24 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 25 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 26 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 27 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres |
| 28 | Base course of floor consisting of100mm thick cement concrete1:8:16 with stone aggregate 40mm gauge and100mm Fine sand filling using mechanical mixer for mixing of material |
| 29 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Udaipur Green Marble Tiles of thickness 18mm to 20mmSlabs sizes above 0.50 sqm |
| 30 | Providing and laying vitrified floor tiles Size 600x600 mm of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. |
| 31 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. |
| 32 | Supplying and fixing of Japani sheet frames (Chowkat consistingof18gauge(1.25mm) thick steel sheet of the specified section (standard designlatest), includingironlugs(holdfasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower boltsand finished, fixed in position including the cost of cement concrete1:3:6for fillingintheframeandcement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-inharge . Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter |
| 33 | Supplying and fixing of Japani sheet frames (Chowkat)consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard designlatest), includingironlugs(holdfasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower boltsand finished, fixed in position including the cost of cement concrete1:3:6for fillingintheframeandcement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-inharge .Door and window frame of size113mmx60mmx with 35mm wide single rebate |
| 34 | Wire gauge Hollock wood door shutter without springs housed in chowkhat 35 mm thick |
| 35 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. (a) (ii) panelled, glazed or glazed and panelled.35mm thick |
| 36 | Providing&Fixing glass panes with nails and putty or wooden strip complete in all respect 5.0mm thick Plate glass (INDIAN) |
| 37 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 38 | Providing&fixing16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with handrail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 39 | Cold twisted detormed (Ribbed/Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works,where not including in the complete rate of RCC including bending and binding placing in position complete |
| 40 | Factory manufactured Solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS-2202-1 (1999) (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iii) 30 mm thick |
| 41 | Wire gauge Hollock wood door shutter without springs housed in chowkhat. (a)35mm thick |
| 42 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 43 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : (a)300mm x 16mm |
| 44 | Providing and fixing helical door spring 150mm (superior quality) including necessary screws, complete |
| 45 | Flush Door |
| 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 47 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 48 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 49 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 50 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 51 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 52 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 53 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 54 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 55 | Grouting the joints of flooring tiles having joints of 3mm width,using epoxy grout mix of 0.70kg of organic coated filler of desi red shade(0.10kg ofhardener and 0.20 kg of resinper kg), including filling / groutingand finishing complete as per direction of Engineer-in-charge. 600x600 mm |
| 56 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 57 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorativeProviding and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorativelamination on one side. |
| 58 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material frommarket to workshop & workshop to site of work. |
| 59 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. II (size of door 701mm to 850mm) |
| 60 | Providing & fixing interlocking wall panneling premiuim quailty with gutties drilled screwed along existing walls including shading complete |
| 61 | Providing and fixing commercial plywood 18mm thick |
| 62 | Providing & Fixing decorative high pressure laminated sheet 1mm (1Star) thickwithhighdensityprotectivesurface layer and reverse side of adhesive bondingqualityconforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 63 | Public Health Works |
| 64 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but excluding cost of lead jointing. Type - B |
| 65 | qty as per Table Atached |
| 66 | 110mm o/d SWR UPVC pipe line laid complete |
| 67 | 90mm o/d SWR UPVC pipe line laid complete |
| 68 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 69 | qty as per Table Atached |
| 70 | For 110mm o/d pipes |
| 71 | Elbow 90 degree ( all side socketed) |
| 72 | Coupler |
| 73 | Floor trap 110mm x 110mm Deep |
| 74 | For 90mm i/d pipes |
| 75 | Elbow 90 degree ( all side socketed) |
| 76 | Coupler |
| 77 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) |
| 78 | 110mm o/d |
| 79 | 90mm o/d |
| 80 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 81 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 82 | Construction of brick masonry inspection chambers size as given below upto 0.60 m average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 83 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 84 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in built up area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. |
| 85 | Earth work upto 1.5 m. Depth |
| 86 | All classes of soil except rocky |
| 87 | for 160 mm Sewer Line IC to MH |
| 88 | 16.00 m x 0.62 m x 1.20 m |
| 89 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 90 | Type A |
| 91 | 160mm o/d SWR UPVC pipe line laid complete |
| 92 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. |
| 93 | For covering Sewer Line Type II |
| 94 | For Sewer Line 160 mm i/d (Type-I) as per Detail attached |
| 95 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 75x120 cm and 120 cm deep |
| 96 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda Sewer connections upto 300 mm id |
| 97 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer in charge ) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer in charge. |
| 98 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nut |
| 99 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 100 | Providing and fixing in position vitreous Chinaware white large flat back or angular lipped front urinal 610 mm high of approved make (to the approval of the Engineer-in-charge) (610 mm x 410 mm x 380mm) consisting of C.P. waste 32 mm dia and C.P. brass spreader, complete. |
| 101 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. |
| 102 | Size 550 mm x 400 mm x 815 mm |
| 103 | Size 560mm x 410mm (above counter oval) |
| 104 | Providing and fixing vitreous chinaware pedestal of approved make ( to the approval of Engineer-in-charge) for washhand basin complete in all respect. |
| 105 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 106 | Providing & fixing in position best Indian make PVC flexible tube connection.PVC tube connection of size 15 mm x 300 mm with CP nut |
| 107 | Providing and fixing PVC waste pipe 32mm complete in all respect. |
| 108 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 109 | C.P. brass towel Ring |
| 110 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 111 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 112 | C.P Brass bib cock long body |
| 113 | Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer-in-charge). |
| 114 | C.P.brass 15mm Angle valve |
| 115 | C.P.brass 15mm Concealed stop cock with flange |
| 116 | Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 117 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long |
| 118 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mm x 450mm |
| 119 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs |
| 120 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge) fixed into wall with C.P brass screws complete in all respect. |
| 121 | C.P. brass toilet paper holder |
| 122 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks (1000 lt x 1no) |
| 123 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 124 | G.I. tank nipple 25mm i/d |
| 125 | G.I. tank nipple 32mm i/d |
| 126 | Construction of Platform complete as per Specification & Desired by Engineer in Charge (for 1000 ltr tank) |
| 127 | Internal and External Water Supply System |
| 128 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 129 | Detailed Attachment |
| 130 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 131 | SDR 11 CPVC pipes & fittings 25mm o/d |
| 132 | SDR 11 CPVC pipes & fittings 32mm o/d |
| 133 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 134 | Size 75 mm x 75 mm |
| 135 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 136 | Through wall 11.43 cm thick |
| 137 | Through wall 22.86 cm thick |
| 138 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 139 | 25mm i/d Brass Ball valves |
| 140 | 32mm i/d Brass Ball valves |
| 141 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4kg Capacity |
| 142 | Tiling |
| 143 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 144 | Providing and laying Rectified Porcelin floor tiles 400 x 400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20 mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . |
| 145 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 146 | Coloured Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 147 | 2 no. x 1.5*0.8 |
| 148 | Extra labour for projected nosing of stair case of any shape and design. |
| 149 | Supply, installing and comissioning of BEE 2 star 1.5 ton split type air conditioner ISI marked reputed/equivalent make wall mounted Air Conditioner Non invertor technology including cordless remote fixed speed with 100% copper coil material (evaporator and condensor) for installing ID and OD units on terrace with copper pipe 3 mtr Complete in all respects. |
| 150 | As per detail attached in table |
| 151 | AUTOMATIC VOLTAGE STABLIZER: |
| 152 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with inputvoltage140-260voltssinglephase AC supply and output voltage 220±5% volts single phase AC supply having main silicon core copper wound stepup transformer with suitablenos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relayand single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp .meter and voltmeter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided: |
| 153 | Automatic Voltage Stablizer 4 KVA |
| 154 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 10 Kgf/cm2 - 25mm i/d |
| 155 | For AC- 3 mtr/ each |
| 156 | Cutting holes upto 23 cm square through B.B.in cement walls or stone masonary wall in cement for pipes,and making good the same & finishing according to existing finish where required |
| 157 | Through wall 22.86 cm thick |
| 158 | Providing and Fixing copper pipe and insulation including Indoor to Outdoor Cable |
| 159 | For 2.0 tonne split AC- 3 mtr/ each |
| 160 | Electrical Works |
| 161 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:-Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 162 | Wiring fan point (With fan box) |
| 163 | Wiring light point |
| 164 | Wiring call-bell point |
| 165 | Wiring 6Amp. wall socket point |
| 166 | Wiring 6Amp. Plug control comprising wall socket point |
| 167 | Wiring 16/20Amp. power plug control point |
| 168 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):- Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 169 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. Erected at switchboard height. |
| 170 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):- Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): |
| 171 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 172 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):- Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 173 | Wiring Networking socket point RJ45 (one module) |
| 174 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 175 | Overall size 1.5sq.mm (Un-sheathed) |
| 176 | Overall size 2.5sq.mm (Un-sheathed) |
| 177 | Overall size 4sq.mm (Un-sheathed) |
| 178 | Overall size 6sq.mm (Un-sheathed) |
| 179 | Overall size 10sq.mm (Un-sheathed) |
| 180 | Overall size 16sq.mm (Un-sheathed) |
| 181 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un- armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 182 | Overall size 25sq.mm (3½ Core) Un- armoured (Loose) |
| 183 | COPPER EARTHING: 8 SWG COPPER EARTHING :Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below gsum level in the hole of excavation having bore dia. 125mm and sursumed by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below gsum level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) asum the hole of excavation:- |
| 184 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below gsum level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 185 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below gsum level in the hole of excavation having bore dia. 125mm and sursumed by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A- class), 3metre long should be laid in the hole of excavation 1 feet below gsum level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) asum the hole of excavation:- |
| 186 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 187 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 188 | Additional Length 20mm x 3mm thick Copper Tape |
| 189 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 190 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 191 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 192 | MCB Triple Pole 50, 63amp. (10kA, Curve- C) |
| 193 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 194 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 195 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB 's/ RCBO's / RCCB's: .Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 196 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 197 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 198 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 199 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 200 | On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure) |
| 201 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 202 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 203 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 204 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 205 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 206 | TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp) |
| 207 | Supply and Erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 208 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per ISMEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 209 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 210 | Supply and erection of LED Flood Light 80 watt, AC supply voltage 140-270 volts, 50Hz± 3% (including BIS Certified potted single diver with screenor laser printing logo LED driver with pressure die cast or extruded aluminium housing with control gear (IP66 protection), THD<10%, CRI minimum70, High power LED (with wattage 1 to 5 watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10 KV external SPD, Min IK 07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-chargeat site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter IONNo:AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 211 | Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with aluminium louver shutter double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 212 | Supply and erection of Recessed Mounted 36 Watt LED 2x2 panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 213 | Supply and erection of 30 Watt Suspended Linear LED Luminaire suitable for general lighting applications, having extruded aluminium housing with flush opal diffuser for uniform illumination, complete with inbuilt electronic constant current LED driver, THD <10%, CRI ≥70, efficacy not less than 100 lumens per watt, suitable for 140-270V AC supply. The luminaire shall be suspended through suitable suspension kit/cables and complete with all mounting accessories, connections, testing and commissioning, as approved and desired by the Engineer-in-Charge at site. The LED fitting shall conform to the specifications approved by Technical Advisor, Punjab Government vide Letter No. AT/2021/GL/1410-1422 dated 06.05.2021 and subsequent amendments. |
| 214 | Supply and erection of 40 Watt Suspended Linear LED Luminaire suitable for general lighting applications, having extruded aluminium housing with flush opal diffuser for uniform illumination, complete with inbuilt electronic constant current LED driver, THD <10%, CRI ≥70, efficacy not less than 100 lumens per watt, suitable for 140-270V AC supply. The luminaire shall be suspended through suitable suspension kit/cables and complete with all mounting accessories, connections, testing and commissioning, as approved and desired by the Engineer-in-Charge at site. The LED fitting shall conform to the specifications approved by Technical Advisor, Punjab Government vide Letter No. AT/2021/GL/1410-1422 dated 06.05.2021 and subsequent amendments. |
| 215 | Supply and erection of Wall Fan Plastic Body 400MM, 16\\" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender