Tender For State Plan-2025-26-Cwss To Chavara-Panmana--Supply And Fixing Of 250 Kva Outdoor Transformer To Raw Water Pump House, Sasthamcotta (Jalanidhi Plant) Under Ph Section, Chavara-General Civil Work
Tender Overview
Project Description
Tender for State Plan-2025-26-Cwss To Chavara-Panmana--Supply And Fixing Of 250 Kva Outdoor Transformer To Raw Water Pump House, Sasthamcotta (Jalanidhi Plant) Under Ph Section, Chavara-General Civil Work
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Sep-2026 | Extension ofdue datedue tono participation | Date | 22-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing of 250 kVA outdoor transformer to Raw water pump house |
| 2 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | OD27827/2026-2027:Supply and installation of Transformer 250 KVA ,11KV/433V ,50c/s, oil cooled type, vector group DYN11,copper wound outdoor type with cable box at the 11KV side and LT side OFF load tap atthe 11KV side |
| 4 | OD285836/2025-2026:Constructing the RCC foundation for the 250 KVA transformer including RCC centering shuttering etc complete. |
| 5 | OD107388/2025-2026:Charges for cutting existing fencing system and extension of fencing using 40 x40 x 6 mm m.s, Angle and 20 x 3 mm m.s, Flat as supports. Wire mesh of net size 50 x 50 mm and is used for yard perimeter 15mtr x 4mtr and frame of fenching is 2 mtr and also making door of size 2mtr x 2mtr size with suitable finches (250 kVA transformer). |
| 6 | OD107397/2025-2026:Supply and installation of neutral CT's appropriate ratio 70/5 A 10VA Burden on neutral connection of transformer including all accessories required control cabling with 2.5 sq.mm Cu armoured cable from neutral CT to E/F relay to respective in corner side of MV panel and from E/F relay to respective LBS trip circuit is also included in scope of work |
| 7 | OD107396/2025-2026:Supply and providing efficient plate earthing using 1200 X 1200 X 12 mm CI plate earth electrode, water pipe, earthing strip clamps, funnel, terminal electrode etc and pit filled with alternate layers of charcoal and salt etc. The earthing station should confirm to IS 3043/87 including civil cost |
| 8 | OD107402/2025-2026:Supply and laying following copper - 25x3 mm Cu, for a length of 150 meter and 10 SWG Cu for a length of 60 m |
| 9 | OD107403/2025-2026:Charges for extension of existing MSB after re positioning it in new position and Fabrication, Installation, Testing and Commissioning of extension Cubicle type, dust and vermin proof, floor mounted, front operated switch board made out of 16SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. The switch board should have a set of suitably rated TPN Aluminium Busbars with the specified current and fault level insulated with heat shrinkable, color coded PVC sleeves and supported using DMC/SMC piller or finger type Busbar supports. the design should be as per the standards of the electrical inspectorate. All LED indication type lamps, CT's, Multifunction meter, Earth Fault Relay, Castle Key InterLock and 2A Backlite fuses are included in this panel. - INCOMER: 800A 4P 50kA MDO ACB - 1 No, 800A 4P BUS COUPLER - 1 No. OUTGOING: 320A 36kA 3P MCCB - 2 No |
| 10 | OD107451/2025-2026:Supply and laying of the following aluminum armoured LT cable using all suitable accessories through existing cable trench or cable trays 3.5 core 185 sq. mm Armade aluminium Cable and 4core 1.5 mm Cu control. Cable ( 100 meter each) |
| 11 | OD107497/2025-2026:Fire protectionSupply and providing 11KV Rubber mat size of 1800 x1900 x12mm-3 NosSupply and providing LT Rubber mat 2000mm x 1000mm x 6 mm-3 NosSupply and providing 5 kg dry chemical powder type (DCP) fire Estinguisher as per regulations-2 NosSupply and providing 2 Fire buckets with single stand.-2 setsSupply and providing First Aid/ Shock tratment Chart-1 NoSupply of 111KV Hand Gloves-4 pair |
| 12 | OD107521/2025-2026:Removal, testing, and reinstallation of Neutral CT and obtaining certificate from Meter Testing and Standards Laboratory |
| 13 | OD107523/2025-2026:Removal,Testing and ReInstallation of measuring CTs and EFRs obtaining certificate from Meter Testing and Standards Laboratory |
| 14 | OD107533/2025-2026:Fabrication and erection of cable trays /cable supports fabricated out of MS angles and M S flats of adequate size with sufficient width and spacing between successive cross members and supports at adequate spacing. The cable trays and supports shall be painted with 2 coats of zinc chromate primer and 2 coats of enamel paint. |
| 15 | OD107537/2025-2026:\\"Statutory Approval - Obtaining statutory approval from Eletrical Inspectorate including preparation ofdrawings, obtaining approval for the drawings arranging inspection of the installations and obtainingsafety certificate etc.after completion of the work and avail supply from KSEB. The necessary statutory fees if any payable to theElectrical Inspectorate/ KSEB will be paid by KWA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender