Tender For Provision Of Ups Room With Allied Services For Edp At Camero Complex & Provision Of Flame Proof Lights And Fans At Various Libraries At Afro Camero Complex
Tender Overview
Project Description
Tender for Provision Of Ups Room With Allied Services For Edp At Camero Complex & Provision Of Flame Proof Lights And Fans At Various Libraries At Afro Camero Complex
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster etc on brick wall or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and disposed off unserviceable materials to out side MOD land complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for rendering CM (1:4) 10 mm thick on other than fair faces of brick work /ceiling or concrete surfaces etc including finished even and smooth without using extra cement complete all as specified and directed by Engr In Charge |
| 3 | M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper/ oil emulsion distemper on ceiling/walls over a coat of primer incl 1.5 mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge. |
| 4 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, up to four storey height building complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for preparation of old surface and applying two coat of oil bound distemper white or tinted on Ceiling complete all as specified and directed. |
| 6 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc complete all as specified and as directed by the Engineer-in-Charge. |
| 7 | M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge. |
| 9 | M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor .complete all as specified and as directed by Engr-In-Charge. |
| 10 | M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 but not exceeding 0.72 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor including vertical surface of wall such as skirting incl 10mm thick cement plaster (1:4) as in backing coat of tiles and dismentling complete all as specified and as directed by Engr-In-Charge. |
| 11 | M&L Glazed ceramic coloured tiles in vertical surface 450X 300X 7-8 /300x600x9-10 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 complete all as specified and directed by Engr In Charge. |
| 12 | M&L for cement concrete in foundation,filling and mass concrete, type D-2, 1:3:6, (using 40mm graded stone aggregate) finished even and rough to receive floor topping and Plinth protection complete all as specified and directed by Engr In Charge. |
| 13 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge. |
| 14 | M & L for providing and fixing factory made uPVC white colour casement (openable.)door made of extruded profile with wall thickness of 2.3mm (+/- 0.2mm). Door profile with hollow section with multi chamber, frame(67mmx64mm). sash (65mmx108mm). T profile (One vertical length in between two shutters) (60mmx71mm)Glazing bead corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware EPDM gasket + -0.2 mm thick galvanised steel frame (28mmx21.5mrn) sash (31mmx27mm) 'T' profile (27mmx17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastners. Hardware: [ casement door handle both side made of zinc alloyed (while powder coated) Corner strikers: Cyilnder. Door transmission gear made of mild steel with multi point locking system with strikes, 3D hinges of zinc alloyed (white powder) and (7-8) mm thick glazing with selected quality glass. The unit rate quoated by contractor includes cost of glass and includes all and includes all other connected accessories & making good with which is required in PCC/RCC/plaster. Net opening will be measured for payment purpose (A) Area exc. 2.00 sqm each (b) uPVC frame, sash and mullion extruded profiles, minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made complete all as specificed and directed. |
| 15 | M & L for providing and fixing factory made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm (+/0.2mm). Window profile with hollow section with multi chamber, frame (60mmx58mm), T profile (One vertical length in between two shutters) (60mmx74mm) Glazing bead(35x20mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drianage of water etc. making arrangement for fixing of hardware EPDM gasket 1.2 + -0.2 mm thick galvanised steel frame (28mmx21.5mm) 'T' profile (27mmx17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastners. 5mm thick glazing with selected quality glass. (Note : The unit rate quoated by contractor include cost of glass and includes all other connected accessories like film or tinted glass. Net opening will be meausered for payment purpose) (A) Area n.exc. 1.50 Sqm each complete all as specificed and directed. |
| 16 | Providing and fixing factory made uPVC white colour casement /openable Partition made of extruded profiles with wall thickness of 2.3mm (+/0.2mm). Window/door/partition profile with hollow section with multi chamber, frame (60mmx58mm), sash (60mmx78mm),cut and fusion welded at all corners, including drilling of holes for fixing hardware and drianage of water etc. making arrangement for fixing of hardware EPDM gasket 1.2 + -0.2 mm thick galvanised steel frame (28mmx21.5mm) sash (31mmx27.5mm) 'T' profile (27mmx17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastnerszinc alloyed (while powder coated) 5.5mm thick glazing with selected quality glass. (Note : (a) The unit rate quoated by contractor including cost of (7-8) mm glass direction including cuttings, grooves etc. (b) membrane bonded completely to the substrate & the over laps are them sealed/fused. (c) uPVC frame, sash and mullion extruded profiles, minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made complete all specified and directed by Engr-in-Charge. |
| 17 | S&F as in repair Aluminium(extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as directed and specified. |
| 18 | S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets ,including fixing of hold fast in PCC 1:2:4 type B1 ( using 20 mm graded stone aggregate ) making good of disturbed portion complete all as specified and directed. |
| 19 | M&L for prepartion of new steel surfaces of any description not other described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed |
| 20 | S&F as in repair false ceiling with Semi perforated 12mm thick acoustical false ceiling, (fire retardant and sound absorbent) micro regular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 475 (Part 4) -1970 and light code description unit rate No 429 Sub Head : 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 grams per sqm including both sides) comprising of maint -T runners of size 15x32mm of length 300mm, cross -T of size 15x32 of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @80 grams per sqmm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-Shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall /partition with the help of plastic rawl plugs at 450mm centre to canter and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of Engr- in -charge |
| 21 | Material and labour as in repair for false ceilings using GI snap grid system with rool-formed out of hot drip galvanised steel capings (Powder coated) main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceilimg board, prepainted cement fibre board size 595x595x4mm thick any texture (Lake, Hill, ocean cascade or Electra ) suspended from from RCC roof/ structural members of soofits angle cleat cut out etc to their equal line and shape as per manufactureres recommndations at any height. Complete all as specified and as directed. |
| 22 | Taking Down existing old /unserviceable Split AC 1.5/2.0 Ton Capacity/ Tower AC/Package AC and deposited to MES Store yard of AGE E/M Subroto Park. Complete all as specified and directed. |
| 23 | Supply installation testing and commissioning of split type AC 2.0 TR capacity having indoor and outdoor units inverter type with copper tube evaporator and condensing unit with cordless remote control unit and with minimum 5 star rating and ISEER 5.05 and 3 core copper cable, cooling tube , drain water pipe etc up to 3 mtr all as specified and directed by Engineer -in -Charge. |
| 24 | S & F refrigerant line copper tube 1/2'' bore incl insulation of AC pipe complete all as specified and directed. |
| 25 | S & F refrigerant line copper tube 1/4'' bore incl insulation of AC pipe complete all as specified and directed. |
| 26 | Supply & Fixing of PVC pipe of size medium grade 25mm dia fixing on wall by using clamps and screwing including necessary tee, collar, bend, socket etc complete all as specified and directed. |
| 27 | M & L for Point wiring using approved colour coding as per IS, with stranded copper conductor FRLSH 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade,ISI-694 marked in and including heavy duty, PVC concealed conduit after chasing the wall etc and making good of disturbed surface including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes duly powder coated with earth dolly duly, covered with modular plates suitable for modular switches, sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. |
| 28 | All as per item No-27 above but one fan/exhaust fan and wall mounted fan point controlled by one SP switch. |
| 29 | All as per item No-27 above but for one 3 pin socket out let, 6 Amps on Independent board |
| 30 | All as per item No-27 above but for one 3 pin socket out let, 6 Amps on same board |
| 31 | All as per item No 27 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge. |
| 32 | S & F for Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed. |
| 33 | S & F for modular Socket, 6A - 3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed . |
| 34 | S & F for Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed . |
| 35 | S & F for Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed. |
| 36 | S & F for electronic modular fan regulator rotary flush step type 120 watt, 240 volt complete complete all as specified and directed. . |
| 37 | S & F for Ceiling roses, surface bakelite 65x50mm 3 terminals , PVC/ Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed. |
| 38 | S & F heavy duty exhaust fan 300mm sweep, speed 1400 RPM, corrossion less mild steel body of motor, plastic/fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, 230/240 volts single phase complete including making opening of suitable size of wall, grouting bolts and making good the distrubed surfaces and connection with 1.5 sqmm copper conductor flexible wire from ceiling rose to fan complete all as specified and directed. |
| 39 | Supply & fix energy efficient BLDC ceiling fan 1200mm sweep , 28 Watt with remote , ISI mark with 5 star rating , white colour, single phase including all fixing arrangement hanging in roof like suitable size of fan road clips , bolt , nut , washers and 3 core flexible copper wire of size 1.5 sqmm not less than 0.5mtr long with all accessories complete all as specified and as directed. |
| 40 | Supply and fixing LED luminaire 600 mm x 600 mm, intellegent, modular high efficacy with integrated PIR sensor for autonomous operation ,35/36 watt, 4000K, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size with THD<10% complete all as specifed and directed .(Make Havells Cat No VENUSNEOHE2X2R36WLED830PIRSENSOR in Philips/ Bajaj/ Crompton/ WIPRO |
| 41 | Supply and fixing LED lights fitting 1x 20W, 6500 K, THD<10% 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 42 | M & L for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) or flexible PVC pipe for connection of Battery backup complete with all acessories and fittings cable laid/ fixed on surface of wall and surface conduit/ flexible pipe on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of 10.0 Sqmm single core wire and one run of PVC conduit shall be measured as one unit for payment purpose. |
| 43 | M & L for submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of 6.0 Sqmm single core wire and one run of PVC conduit shall be measured as one unit for payment purpose. |
| 44 | M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of 4.0 Sqmm single core wire and one run of PVC conduit shall be measured as one unit for payment purpose. |
| 45 | S&F MCB DB VTPN 4 ways with provision for FP MCB/isolator/RCCB/MCCB etc as incomer and SP/TP MCBs as out going double door IP 54 complete prewired including Bus bar etc suitable for operation on 415 Volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/Stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed by Engineer-in-Charge including MCCB 4 poles 200 Apms Capacity, rup capacity 10 KA (Ics = 100% Icu) complete all as specified and directed (Note- MCB SP/TP shall be measured and paid seperately) |
| 46 | Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately. |
| 47 | Supply and fixing MCB distribution board with Bus bar 200A neutral link ,earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately. |
| 48 | Supply and fixing MCB TP 63 Amps , 415V, 50 Hz 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by engineer-in-charge. |
| 49 | S&F for MCB SPN 63 Amps 10 KA, 240 volt 50 Hz 'B' Series complete all as specified and directed by engineer-in-charge. |
| 50 | S&F for MCB SP 6 to 32 Amps 10 KA, 240 volt 'B' Series complete all as specified and directed by engineer-in-charge. |
| 51 | Supply and Sheet metal enclosure single pole and neutral with two pin and earth plug and socket 20 Amps compete with one SP MCB 20 Amps fixed flush in wall including cutting chases in wall for fixing DB and making good the disturbed wall surface to match with existing specification. complete all as specified and directed. |
| 52 | Taking out old/defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor cable of size 35 sqmm 3.5 core from trenches/wall under ceiling etc complete all as specified and directed. |
| 53 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed. |
| 54 | M&L for Conductive Concrete Earth Grid of multiple interconnected Earth Electrodes to achieve the earth resistance value of less than < 5 Ω. The excavation is to be carried out in any type of soil including hard rock. The approx specification are as under:-(i) Earth Electrodes: Metal conductor - Copper bonded MS rod dia 17.2 mm (+/-.5mm), Length 3.0 meter with conductive concrete including provision of bore 85mm to 100 mm dia, 3meter Length of earth electrode. (ii) All earth electrodes (min two nos) should be installed to achieved the desired result . (iii) Interconnected Strip: All the multiple Earth Electrodes will be horizontally interconnected with metal conductor - Copper strip flat size : 25mm x 3 mm & conductive concrete embedding size : 60 mm².(iv) Test Link : Test links - Copper strip flat size : 40 mm x 6 mm x 200 mm shall be provided, at any one of the multiple Earth Electrodes of the grid for connection between earth grid pit and application.(v) Pit Cover : RCC pit cover & frame shall be provided at all Earth Electrode (with test links). Note :- (a) Bidder shall produce certificate for resistivity of conductive concrete.(b) Fault Current Tested at 35 KA Peak With 17.2mm copper bonded rod .(c ) On completion of earthing engineer in charge will check the earth resistance in presence of user, Contractor will re-do the earth if earth resistance value is more than 5 Ohm if value not found as per contract the necessary action to be taken by the contactor for achieving the desire result. (d) All connecting strips would be of copper of size 25x3 mm and cost of the same is included in the rate quoted, upto test point.(e) Test certificate of earthing material for ROHS compliance, Resistivity value and fault current test for electrode from certified NABL laboratory shall be submitted. (f) Contractor will annually check the resistance value of earth grids after completion of work.(g) The vendor to provide CPRI test report for current greater than 20 KA with peak at 38 KA, The report shall not be more then 5 year old from the date of tender. (h) The product should be ROHS compliance. l) The earthing to be carried out by OEM only. The MOU in this respect to be submitted by contractor while quoting the contract. |
| 55 | S&F 20 mm x 3 mm size copper strip Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed. |
| 56 | Supply and fix industrial grade power socket compatiable for 3 pole IEC 60309 standards compliant plug, ambient temperature (-20 C to 80 c), Maximum continous voltage 255V AC, Protection rating IP 20 incl 32A MCB SPN and single phase power line surge suppressor double pole and neutral enclosure 240 volt 20 Amps with a two pin and earth plug and socket complete all as specified and directed by Engineer-In- Charge. Please Enable Macros to View BoQ information |
| 57 | Supply and fix industrial grade power socket compatiable for 3 pole IEC 60309 standards compliant plug, ambient temperature (-20 C to 80 c), Maximum continous voltage 255V AC, Protection rating IP 20 incl 32A MCB SPN and single phase power line surge suppressor double pole and neutral enclosure 240 volt 20 Amps with a two pin and earth plug and socket complete all as specified and directed by Engineer-In- Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender