Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #57309120

Tender For Repair, Replacement, Maintenance Of Existing Unserviceable Wiring Submain Wiring, Dbs, Light Fittings And Fixtures At Qtrs Of Hc Wing, Vindhya Vihar, anganwadi center C Under Ge (Awc) Mhow

Issued by Statutory Bodies & Commissions/Committees · Indore, Madhya Pradesh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
3 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair, Replacement, Maintenance Of Existing Unserviceable Wiring Submain Wiring, Dbs, Light Fittings And Fixtures At Qtrs Of Hc Wing, Vindhya Vihar, anganwadi center C Under Ge (Awc) Mhow

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-Oct-2026
2 01-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-Oct-2026

BOQ

Name of Work:- REPAIR, REPLACEMENT, MAINTENANCE OF EXISTING UNSERVICEABLE WIRING SUBMAIN WIRING, DBs, LIGHT FITTINGS AND FIXTURES AT QTRS OF HC WING, VINDHYA VIHAR, AWC C UNDER GE (AWC) MHOW
Sl. No. Item Description
1Taking down carefully copper / aluminium point wiring (light, fan, sockets or power) complete including all fittings and fixtures such as switches, sockets, ceiling roses, pendens, regulators, light fittings etc, removing materials to store for taking credit and making good disturbed surfaces complete all as specified and directed.
2M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module and blank plates, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed.
3Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch
4Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch.
5Description all as per ser item No. 2.00 above but for one light point controlled by one, 2 way 5/6 Amps switch.
6M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed.
7M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through PVC casing and caping of suitable sizes (medium grade ISI marked ) in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame of any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed.
8Description all as per ser item No. 7.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch.
9Description all as per ser item No. 7.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch.
10Description all as per ser item No. 7.00 above but for one light point controlled by one, 2 way 5/6 Amps switch.
11M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including rigid,non-metallic PVC casing and caping (medium grade) on wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. complete all as specified and directed.
12S&F in replacement of Ceiling rose 3 terminal AC 230 V, 50 Hz ISI Marked all as specified and directed.
13S&F in replacement of modular switch 1 way 6A, 1 module, ISI Marked complete all as specified and directed.
14S&F in replacement of modular switch 2 way 6A, 1 module, ISI Marked complete all as specified and directed.
15S&F in replacement of modular bell push one way, 5/6 Amp, 240 V ISI Marked complete all as specified and directed.
16S&F in replace modular switch 1 way 16A, 1 module, ISI Marked complete all as specified and directed.
17S&F modular socket outlet, 6A - 2/3 pin combined 2 module, ISI Marked complete all as specified and directed.
18S&F modular socket multipurpose 6/16A, 2 module, ISI Marked complete all as specified and directed.
19S&F stepped type electronic modular fan regulator - 2 module, with 5 step, AC 50 Hz, 230/240 Volts grade, ISI Marked complete for BLDC fan any brand all as specified and directed.
20S&F call bell, ding dong, AC 230 V, 50 Hz complete all as specified and directed.
21S&F TV socket outlet ISI Marked complete all as specified and as directed.
22S&F RJ 11 /RJ 45 LAN jack with shutter ISI Marked complete all as specified and as directed.
23S&F modular type angular lamp holder, PVC / Polycarbonate fancy type with back plate 230 V, 50 Hz including taking down complete all as specified and as directed.
24S&F in replacement of pendent lamp holder, brass body for decorative wall fittings complete with mounting clamp (as per sample) for fixing inside wall mounted luminaire 240 volt complete all as specified and as directed.
25S&F in replacing metal plug and socket DB concealed in wall, double pole 240 volts and including one 20 Amp MCB SPN, C-Curve, ISI Marked complete incl making good of disturbed surface by plastering, painting, applying putty all as specified and directed.
26S&F in replacement of 9 watt LED lamp (5 star rated) with B22 base including taking down complete all as specified and as directed.
27S&F in replacement of 9 watt LED lamp warm white(5 star rated) threaded with B22 base including taking down complete all as specified and as directed.
28S&F in replacement of decorative ultra slim poly carbonate LED tube light fitting 4 feet long 22 watts with THD less than 15% very high efficiency suited for T-8 tube light luminaire with system efficiency 110 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed.
29S&F in replacement of wall mounted 10 watts LED batten 2 feet long comprising extruded aluminium heat shrink provided for efficient heat dissipation & integrated electronic driver with aluminium housing system efficiency of 110 lumen per watt and lumen package ≥1100 lumen, THD < 10% complete all as specified and directed.
30S&F VTPN DB, 04 way, IP- 43, IK 09, double door type with metal door, suitable for fixing up to 3 pole 160 Amp MCCBs as incomer and SP/TP MCB/Isolator as outgoing, including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
31S&F MCB DB, TPN 4 way, IP-43, IK 09, double door type with metal door, 415 V, 50 Hz, suitable for fixing MCB TPN as incomer and SP/TP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
32S&F MCB DB, SPN 8 way, IP-43, IK 09, double door type with metal door, 230 V,50 Hz suitable for fixing MCB SPN as incomer and SP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
33S&F MCCB 4 Pole 160 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link & taking down complete all as specified and directed.
34S&F in replacement of MCCB 4 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link & taking down complete all as specified and directed.
35S&F MCB TPN 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
36S&F MCB TPN 63 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
37S&F MCB SPN 20 to 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
38S&F MCB SPN 40 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
39S&F MCB SP 6 to 32 Amp, 10 kA breaking capacity, 'C' curve complete all as specified and as directed.
40M&L for MCB two way centre off change over switch 40 Amps, for dual electricity supply management complete all as specified and directed.
41M&L for flexible wire twisted 23/0076 of size 1.5 sq. mm for replacement from ceiling rose to light fittings/ceiling fan/exhaust fans complete all as specified and directed.
42S&F in replacement 3 core copper flexible cable 2.5 sqmm complete all as specified and directed.
43M&L for replacement of FRP junction box three terminal and neutral with one MCB SP 20 A for control of security light / garden light / gates / post top lantern incl making good of PCC and finishing with cement rendering complete all as specified and directed.
44M&L for Blank Plate 01 Module complete all as specified and directed.
45Supply and fixing PVC round table of existing size complete all as specified and directted b rengr-in-charge
46M&L for replacing change over MCB 4 pole 63 Amps, 415 volts, 50 Hz complete all as specified and as directed.
47Supply only cross flow fan, 200mm sweep metallic body as per approved sample all as specified and directed.
48M&L for replacing GI tubings 50 mm size light grade for cable protection/stand post of garden lights incl welding bending complete all as specified and directed.
49M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
50M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of , all as shown in electrical plate No. 3 connected to earthing test point and complete all as specified and directed.Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm grade crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
51S & F digital type three phase electric energy meter 415 volt 10 amp to 60 amp complete all as specified and directed
52S & F digital type single phase electric energy meter 230 volt 10 amp to 30 amp complete all as specified and directed
53M&L for decorative wall mounted luminare indoor application made out of stainless steel body with acrylic cover with LED bulb 9W , 230V, 50 Hz complete all as specified and directed . Cat NO LHFOAJE1TN1I060 of Havells or equivalent make in Jaquar/Crompton /Philips / C & S Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57309120
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair, Replacement, Maintenance Of Existing Unserviceable Wiring Submain Wiring, Dbs, Light Fittings And Fixtures At Qtrs Of Hc Wing, Vindhya Vihar, anganwadi center C Under Ge (Awc) Mhow
Basic Detail
Tender No 8984/AWC/MHOW/ OF 2026-27
Bidding Type Tender
Location
City Indore
State Madhya Pradesh
Key Dates
Publish Date 01 Oct 2026
Submission Date 06 Oct 2026
Open Date 08 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
6bf59a65-5b2c-47ad-be0b-133af5addcda.html
BOQ_882526.xls
Makelist8984.pdf
TDocus8984.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 06, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

6bf59a65-5b2c-47ad-be0b-133af5addcda.html

xls

BOQ_882526.xls

pdf

Makelist8984.pdf

pdf

TDocus8984.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders