Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57305699

Tender For special Repair Of Overhead Line To Under Ground From Sarvatra Chowk To Pump House No -2 And special Repair For Conversion Of O/H Lt Conductor Line Ug Lt Cable (Main Line & Street Light) At 297 Fd Wksp Coy Area And From Post No 7 To Post No

Issued by Statutory Bodies & Commissions/Committees · Kachchh, Gujarat
Tender Value
43 Lakhs
Estimated cost
Bid Submission
23 Sep 2026
20 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair Of Overhead Line To Under Ground From Sarvatra Chowk To Pump House No -2 And special Repair For Conversion Of O/H Lt Conductor Line Ug Lt Cable (Main Line & Street Light) At 297 Fd Wksp Coy Area And From Post No 7 To Post No 8 Alongwith Lt Panels In Gandhidham At Mil Stn Bhuj Under Ge (A) Bhuj.

BOQ

Name of Work:- SPL REPAIR OF OVERHEAD LINE TO UNDER GROUND FROM SARVATRA CHOWK TO PUMP HOUSE NO -2 AND SPL REPAIR FOR CONVERSION OF O/H LT CONDUCTOR LINE UG LT CABLE (MAIN LINE & STREET LIGHT) AT 297 FD WKSP COY AREA AND FROM POST NO 7 TO POST NO 8 ALONGWITH LT PANELS IN GANDHIDHAM AT MIL STN BHUJ UNDER GE (A) BHUJ.
Sl. No. Item Description
1Dismantling of old deteriorated ACSR Conductor , of any size , any type and supply and fix aluminium conductor , steel reinforced (ACSR) , of any size, any type , as per existing one and stringing properly on the insulators and binding with aluminium wire , connectors , jumpers complete all as specified and directed. (Note :- Measurement and payment shall be made by measuring horizontal distance between centres of two adjacent poles and adding 3 % for sag , jointings, jumpers etc.)
2Supplying, Laying, jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 16 Sqmm, 4 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
3Supplying, Laying, jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 35 Sqmm, 3.5 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
4Supplying, Laying, jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 35 Sqmm, 3.5 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
5Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
6Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
7Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
8Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
9Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
10S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor of size 6 sq mm served with inner sheating of pvc tape and overall pvc sheathed in service connections suspended bu insulating hangers not more than 1 mtr apart incl 4mm suspension wire,one twin core cable flat or circular complete all as specified & directed( Note :from junction box to light conncector of street light fittings including heavy duty PVC conduit of size 20mm dia with bracket, lugs /thimbles according to size of cable complete all as specified and directed.
11Supply and fixing in replacement of Street light fitting in new generation energy saving environemental friendly long life LED street light with single die ceramic base high power LED light source,PDC housing with top openable access to driver for ease maintenance , lumen output 12000-21000 , system effiency 100 lm/watt , color temp 5700 K , made up of LM6 high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 , operating voltage 140-270 Volt and impact of capacity 90 Watt, including bracket with clamp and all accessories complete all as specified and directed.
12Supply and fixing pole mounted thermoplastic cable junction box for steet light with IP-66 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of size 200mm x 160mm x 98mm with front door opening system including terminals for one incoming and two outgoing cables of size 16 sqmm 4 core, one MCB SP 10 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed ,
13Supply, erecting and fixing in true vertical position, Prestressed cement concrete pole 9 mtr long confirming to IS-1678 (latest) with minimum cross sectional area 102 mm x 152 mm at top and 102 mm x 289 mm at bottom , class - 10 ,removing of old pole to side and refixing of MS channel , restringing of conductor, providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete (M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents and include remove existing pole .)
14M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
15M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
16S&F Galvanized Iron pipe 15 mm med grade with all fitting fixed to cable junction box to street light fitting for cable protection with suitable size clamp, nut bolt and washers complete all as specified and directed.
17S&F mounting bracket made out of light grade GI tubing 40 mm bore 1.5 M long & bend to shape including 02 Nos MS clamps Nut bolts, washers etc complete all as specified and directed.
18M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on complete all as specified and directed.
19Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II complete all as specified and directed.(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule complete all as specified and directed.(iii) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (iv) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of Engr-in- Charge.
20Supply, install, testing and commissioning of feeder pillar box CPRI Approved outdoor type of suitable size with modular compartment and openable doors made out of MS angle iron frame & MS sheet of 3.15 mm thick with double door incl locking arrangements with bases frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shinkable coloured sleeves comprising of the following with earth terminal incl necessary foundatiion work and suitable cable glands for incoming and outgoing cables (Main panel) complete all as specified and directed.
21Incoming (a) Digital voltmeter 0 to 500V with selector switch - 01 No(b) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No(c) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (d) Change Over 160 A - 01 Nos (e) MCCB 4 Pole thermal magnetic release 415 volts 100 A 36 KA-01(incoming),
22Outgoing(a) MCCB 4 pole thermal magnetic release 63 A, 16 KA -01 ( for Sub panel 1)(b) MCCB 4 pole thermal magnetic release 63 A, 16 KA -01 (for sub panel 2)
23All as per Srl item No 19 here - in - before but with aluminium bus bar 200 Amps comprising the following (Sub Panel 1 ) :-
24Incoming (a) Digital voltmeter 0 to 500V with selector switch - 01 No(b) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No(c) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (d) MCCB 4 pole thermal magnetic release 63 A, 16 KA -01 (Incoming)
25Outgoing(a) MCCB 4 pole thermal magnetic release 25 A, 16 KA -04(b) MCB SPN 230 Volts 10 A (street light) - 01 Nos(c) Timer switch - 01 Nos (for street light)(d) Power Contactor-01 Nos
26Supply, install, testing and commissioning and electric connection of feeder pillar outdoor type double door compartmentlized with locking arrangement canopy at top weather proof, vermin/ dust proof of suitable size cubical type factory made of CRCA sheet 3.15 mm thick machine pressed of size 60x60x40 cm and IP-54/55 angle iron frame 40x40x6mm for legs and incl grouted in PCC 1:2:4 type B1 suitable for 440 volts, AC 3 phase 4 wire Bus Bar (4 Way) 4 pole made out of suitable size copper strip capacity 400 Amps mounted on porcelean insulator enclosed chamber with openable shutter both sides complete all as specified and directed.
27M&L for painting of pole by providing 6 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed.
28M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI strip 25*4 mm and GI protection pipe 25 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on complete all as specified and directed.
29Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 25 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule. (iii) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (iv) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
30Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete all as specified and directed.
31Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
32S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed .
33Dismantaling of any type and size of ACSR conductor complete all as specified and directed.
34Disconnecting, taking out, removing old existing unserviceable LT cable overhead service cable of any size etc complete all as specified and directed.
35Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 10 Sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
36Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 25 Sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
37Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 35 Sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
38Supply, installing ,testing and commissioing factory made and tested LT Outdoor Street/Flood Light Control Panel having platform mounted,suitable for 415 Volts 3 Phase and neutral 4 wire,50 HZ AC supply system shall be dust and vermin proof,protection class(IP-65) and made of CRCA sheet steel enclusure 3.15 mm thick suitable framework/Support made out of 40x40x5 mm MS Iron angle frame ,front opening type with aprons for cable entry,with proper ferrul and cable gland,internal wiring with PVC insulated multistranded copper conductor FRLS Cable of adequate size but not less than 4 sqmm,minimum 0.5 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc complete all as specified and directed. Note : The contractor shall submit detail Schematic Layout of the Panel Board for approval from Engr-in-Charge before procurement.The scope of work also comprising of the following :-(i) RYB Phase indicating LED type -01 set. (ii) MCB TPN 40Amps 4 polez,10 KA,50 HZ,415 Volts-01 No (iii) Power contactor 3 Pole,40 Amps.50 Hz,415 Volts-01 No. (iv) Time switch Digital Type,one dial daily,240/415 Volts,50 Hz-01 No. (v) Auto/Manual selector switch 6A-01 No.(vi) RYB Phase indicating light LED Type -03 No.
39Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type (KIOSK type ) , front and back openable , air vent , totally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :-
40Incoming (a) Aluminium Bus bar, 150 Amps TPN -01 set(b) MCCB 4 Pole thermal magnetic release 415 volts 100A 35 KA-01(c) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No(d) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (e) Digital voltmeter 0 to 500V with selector switch - 01No(f) Digital Multifunctional meter - 01 No
41Outgoing(a) MCCB 4 Pole thermal adjustable magnetic release 415 volts 63A 16 ka -3 nos
42Supply and drawing through the pole for making connections to the light fittings, three core, PVC insulated and sheated, Heavy duty,1100 volts grade,multistranded copper conductor (FRLS) cable 3Cx1.5 sqmm complete all as specified and directed.
43Supply and fixing PVC pipe 25/20 mm through FRP Junction to street light clamp on the pole including all connecting accessories to the pole complete all as specified and directed.
44Supply and fixing PVC coated flexible pipe 40 mm for protection of cable etc complete all as specified and directed.
45Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with system efficacy greater or equal to 120 lumen/watt, beam angle =120 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV and optics designed for Road lightning ,PF>0.95 and IEC safety class 1 protection complete all as directed.Make : Philips Cat Part No BRP334 LED 110
46Supply and fixing cable junction box with new pole mounted polycarbonate cable junction box of size 300x200x105 mm or next higher size for street light with IP-66 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system, cable gland, cable terminal for incoming and outgoing cable according to cable size including terminals for one incoming and one outgoing cables of size 16/25 sqmm 4 core, tapping of 3Core 2.5/1.5sqmm from terminals, with one MCB SP 6 Amp 240V AC with mounting on DIN rail, pole clamp of flat iron, nut, bolt and washers complete all as specified and directed .
47Material and labour for cutting of existing road ,insert the required size pipe for drawn of cable etc and repair the same with PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for filling the disturbed road opening for cable crossing include levelling with road surface and smooth finishing complete all as specified and directed. ( for Road Cutting Repair)
48M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth strip 25X4 mm by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on complete all as specified and directed.
49Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to Galvanised iron earth strip 32x6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
50Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing strip and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.Note (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
51NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57305699
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43 Lakhs
LAST DATE 23-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Of Overhead Line To Under Ground From Sarvatra Chowk To Pump House No -2 And special Repair For Conversion Of O/H Lt Conductor Line Ug Lt Cable (Main Line & Street Light) At 297 Fd Wksp Coy Area And From Post No 7 To Post No 8 Alongwith Lt Panels In Gandhidham At Mil Stn Bhuj Under Ge (A) Bhuj.
Basic Detail
Tender No 8440
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 02 Sep 2026
Submission Date 23 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 43 Lakhs
Tender Fee 500
EMD 86000
Exemption Available
Document List
1b919880-1186-4a36-ab17-5979a74c72d9.html
BOQ_882521.xls
LISTOFMAKE.pdf
PS8440.pdf
TENDER8440.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

1b919880-1186-4a36-ab17-5979a74c72d9.html

xls

BOQ_882521.xls

pdf

LISTOFMAKE.pdf

pdf

PS8440.pdf

pdf

TENDER8440.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders