Tender For Comprehensive Maintenance Of Internal Fitting/ Fixtures And Allied Works To Otm And Md Accn Under Zone A And Zone C At Mil Station Dagshai Under Ge Kasauli.
Tender Overview
Project Description
Tender for Comprehensive Maintenance Of Internal Fitting/ Fixtures And Allied Works To Otm And Md Accn Under Zone A And Zone C At Mil Station Dagshai Under Ge Kasauli.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Sep-2026 | CHANGE OF CRITICAL DATE | Date | 29-Sep-2026 |
| 2 | 12-Sep-2026 | CHANGE OF CRITICAL DATES | Date | 24-Sep-2026 |
| 3 | 12-Sep-2026 | CHANGE OF CRITICAL DATES | Date | 24-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Section - I |
| 2 | Taking down carefully copper/aluminium point wiring (light, fan, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed. |
| 3 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH PVC insulated, unsheathed copper conductor cable in and including PVC Casing-n-caping of any size/dia, medium grade fixed on surface of wall complete incl all PVC accessories / fittings, brass screws, washers etc, incl providing 3mm thick plastic laminated sheet top cover for mounting switches/ sockets on boards with suitable size sunk boxes or with PVC gang boxes as per site requirements and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly including taking down old point wiring and making good the disturbed surfaces with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed for the followings :- |
| 4 | One light /Exhaust fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed. |
| 5 | One bell point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed. |
| 6 | One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed. |
| 7 | One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed. |
| 8 | One two way point controlled by two, two way switches 06 Amps complete all as specified and directed. |
| 9 | All as per serial item No 2.03 here - in - before but with 4 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed. |
| 10 | Taking down carefully copper/aluminium point wiring (light, fan, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed. |
| 11 | Material and labour for point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit concealed in walls by making cutting in brick/stone masonry wall of required size with all fittings and accessories, incl sunken boxes and hylem sheet alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly including taking down old point wiring and making good the disturbed surfaces with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed for the following :- Note :- (i) The Switch, sockets shall be mounted on newly provided MS sunken boxes with in and incl 3mm thick hylem sheet of suitable size. (ii) The rate for sunken boxes, hylem sheet and all accessories shall deemed to be included in the quotes rates of the item itself. No seperate payment shall be made in this regard. |
| 12 | One light / Exhaust fan point controlled by one, one way switch 06 Amps complete all as specified and directed. |
| 13 | One bell point controlled by one, one way switch 06 Amps complete all as specified and directed. |
| 14 | One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed. |
| 15 | One 3 pin,06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed. |
| 16 | One two way point controlled by two, 2 way switches 06 Amps complete all as specified and directed. |
| 17 | All as per serial item No 4.03 here - in - before but with 4 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed. |
| 18 | Supply and fixing in replacement of switch piano flush type, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge |
| 19 | Supply and fixing in replacement of switch piano flush type,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge |
| 20 | Supply and fixing in replacement of socket outlet 2 in 1, 3 pin, 6 &16 Amps 240 volts complete all as specified & directed by Engr-in-Charge |
| 21 | Supply and fixing in replacement of socket outlet 3 pin, 06 Amps 240 volts complete all as specified & directed by Engr-in-Charge |
| 22 | Supply and fixing in replacement of bell push flush type , 06 amps , 240 volts all as directed by Engr-in-Charge |
| 23 | Supply and fixing in replacement of door bell ding dong type , 240 volts AC all as directed by Engr-in-Charge |
| 24 | Supply and fixing in replacement of switch piano flush type, 06 Amps single pole, two way 240 volts complete all as specified & directed. by Engr-in-Charge |
| 25 | Supply and fixing in replacement of lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge. |
| 26 | Supply and fixing in replacement of ceiling rose surface, bakelite, three terminal, 240 volts complete all as specified and directed. |
| 27 | Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed by Engineer - in - Charge. |
| 28 | Material and labour in Replacement for sub main wiring with (2 Run) of single core PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC concealed conduit of required size with all fittings and accessories alongwith one single core green colour PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, all as specified and directed. Note :- (i)Thimble/ lugs of suitable rating of MCB should be used with wire for fixing in the MCB. (ii) Three Runs of cable and one run of PVC conduit shall be measured and paid as one unit length . (iii) All chases will be cut by chase cutter only. |
| 29 | Material and labour in replacement for sub main wiring with (2 Run) of single core PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC concealed conduit of required size with all fittings and accessories alongwith one single core green colour PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, all as specified and directed. Note :- (i)Thimble/ lugs of suitable rating of MCB should be used with wire for fixing in the MCB. (ii) Three Runs of cable and one run of PVC conduit shall be measured and paid as one unit length. (iii) All chases will be cut by chase cutter only. |
| 30 | Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.NOTE:- Make of DBs boxes and MCCBs/MCBs shall be of same make. |
| 31 | Supply and fixing in replacement of DB SPN 4 way double door, IP 54 & IK09 certified with fully shrouded Neutral Bar ,PU gasket, 200 Amp rated bus bar 240V conforming to IEC 61439-3 ,CRCA sheet powder coated factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blanking plate as required and making good disturbed surface to match with existing complete all as specified and as directed. |
| 32 | -Ditto- all as per item No 14, but of size 8 way SPN. |
| 33 | -Ditto- all as per item No 14, but of size 12 way SPN. |
| 34 | Supply and fixing in replacement of MCB SP, 'B' series, 6 Amp to 32 Amp, having rupture capacity of not less than 10 KA including taking down unserviceable complete all as specified and as directed. |
| 35 | Supply and fixing in replacement of MCB SPN, 'C' series, 40-63 Amp, having rupture capacity of not less than 10 KA including taking down unserviceable complete all as specified and as directed. |
| 36 | Supply and fixing in replacement of in replacement of VTPN DB 4 way, vertical loadline type, double door, for MCCB as incomer, metal door, shrouded Neutral Bar, Mechanical Impact Strength IK 09 certified, fully insulated busbar assembly, 2 neutral bar, 2 earth bar, cable ties, blanking plates, PU gasket suitable for 4 pole MCCBs upto 160 Amp as incomer and MCBs (TP/TPN/SP/SPN) as outgoing, IP 54 protection, conforming to IEC 61439-3 complete all as specified and directed. |
| 37 | Supply and fixing in replacement of MCCB 4 Pole, 100 Amps, 16 KA 415 Volt, including taking down unserviceable complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of MCCB 4 Pole, 63 Amps, 16 KA 415 Volt, including taking down unserviceable complete all as specified and as directed. |
| 39 | Supply and fixing in replacement of Isolator 4 Pole 'C' series 100 amps capacity AC 415 V,10kA complete all as specified and directed. |
| 40 | Supply and fixing in replacement of Isolator 4 Pole 'C' series 63 amps capacity AC 415 V,10kA complete all as specified and directed. |
| 41 | Material and labour for taking down the unsv geyser of 25/35/ 50 ltr capacities from the site after disconnecting the water connection, electric connection, opening the geyser assembly and descalling the deposits in the inner container and outlet water pipe set complete all as directed by Engineer-in-Charge. (Note:- (i) Replacement of unsv bolts, rubber real, ring nuts, washers to be included in the rate quoted by tenderer. (ii) Material & labour for GI fittings and other connected works shall be measured and paid for separately under respective items of schedule ‘A’ here in after) :- |
| 42 | Supply only geyser syphon assembly steel plate with nuts and bolts, washers, clamps and rubber ring suitable for geysers of 25/35/ 50 Ltr capacity of make and model as per eixsting one complete all as directed by Engineer-in-Charge. |
| 43 | Supply only Thermostatic switch, ISI marked, suitable for geysers of 25/35/ 50 capacity of make and model as per eixsting one complete all as directed by Engineer-in-Charge. |
| 44 | Supply only Heating element 1.5/2 KW capacity with rubber ring Round/triangular type complete with clamps, nuts and bolts washers, etc for geysers, ISI marked suitable as per existing make and model complete all as directed by Engineer-in-Charge. |
| 45 | Supply only Non return valve 15mm dia made of bronze ISI marked heavy duty complete all as directed by Engineer-in-Charge. |
| 46 | Supply only 15mm dia PVC connection 450 mm long , suitable for hot water supply, complete with 2 Nos brass nuts complete all as directed by Engineer-in-Charge. |
| 47 | Supply only 15mm dia PVC connection 450 mm long , suitable for cold water supply, complete with 2 Nos brass nuts complete all as directed by Engineer-in-Charge. |
| 48 | Supply only Zebra fastner of size 12x100 mm suitable for geysers of any capacity of make and model as per eixsting one complete all as directed by Engineer-in-Charge. |
| 49 | Supply and fix exhaust fan, PLASTIC body heavy duty AC single Phase 230V of size 250mm sweep with, blades, and frame and louvers including taking down unserviceable complete all as specified and as directed. |
| 50 | Supply and fix exhaust fan, steel body heavy duty AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers including taking down unserviceable complete all as specified and as directed. |
| 51 | Supply and fix exhaust fan, steel body heavy duty AC single Phase 230V of size 380mm sweep with, blades, and frame and louvers including taking down unserviceable complete all as specified and as directed. |
| 52 | Supply and fixing in replacement of self ballasted LED Retrofit Bulb 5 Star Bulbs (9-12) Watt with PBT body shell and PC diffuser 210 degree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) complete all as specified and as directed. |
| 53 | Supply and Fixing in Replacement of LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete incl testing after fixing all as specified and directed by Engr-in-charge.The specification of the light fitting should meet the following:-(a) Housing of Light fitting : Aluminium Extruded(b) Operating voltage : 150 v to 240v(c) operating temprature : -10 to 45 degrees(d) Lumen efficacy : 105 lumen per watt(e) system lumen : Not less than 1050 lumens(f) Colour temprature : Not less tha 5700k(g) Surge voltage protection : Up to 2 KV(h) Ingress protection : IP20(j) Total harmonic distortion : not less than 20%(k) Power factor : not less than 0.90(l) Input Frequency : 50 Hz (m) Line protection : Under/ Over voltage protection. Note:-contractor need to submit NABL approved LM-79, LM-80 along with sample before installation.(Sample approval) |
| 54 | Supply and fixing in replacement of LED Bulk head 1 x 10 W ,220V, AC, decorative type extruded aluminium channel in thermally conductive material and luminaire efficacy 110 lm/W, beam angle 120 degree, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 55 | Supply and Fixing in Replacement Non-Integrated CRCA Housing(BOX TYPE ONLY) LED fitting fixture( 4 feet length), 18/20 watt aluminium Extruded LED Tube Retrofit type complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size cable incl testing after fixing all as specified and directed by Engr - in-charge . The specification of the light fitting should meet the following:- (a) Housing of Light fitting : Aluminium Batten with polycarbonate LED Rod.(b) Operating voltage : 180V to 270V. (c) Operating temprature : -0 to 45 degrees. |
| 56 | Contd.. Srl Item No. 35.00:-(d) Lumen efficacy : 110 lumen per watt. (e) system lumen : Not less than 1980 lumens. (f) Colour temperature : Not less than 5700-6500k.(g) Surge voltage protection : Up to 2 KV. (j) Ingress protection : IP20.(k) Total Harmonic distortion : not less than 20%. (l) Power factor : not less than 0.90. (m) Input Frequency : 50 HZ. (n) Line protection : Under/ Over voltage protection. |
| 57 | Supply and Fixing of Inverter based LED tube light fitting 20watt, indoor decorative high lumen batten and connecting up with twin core twisted flexible copper wire complete and testing after fixing all as specified and directed by Engr-in-charge . The specification of the fitting should meet the following:-(a) Housing of Light fitting : Aluminium Extruded(b) Operating voltage : 150 v to 270v(c) Operating temprature : -10 to 45 degrees(d) Lumen efficacy : Not less than 100 lumen per watt(e) system lumen : Not less than 2000 lumens max(f) Colour temprature : Not less tha 5700k-6500k(g) Surge voltage protection : Up to 2 KV(h) Ingress protection : IP20(j) Total harmonic distortion : not less than 20%(k) Power factor : not less than 0.90 (l) Input Frequency : 50 HZ (m) Reachargeble battery : 2600 mAH (n) Battery Backup up to 3 HRS (o) Line protection : Under/ Over voltage protection.Note:- Contractor need to submit NABL approved LM-79, LM-80 along with sample before installation (Sample approval). |
| 58 | Supply and Fixing in Replacement of 36 watt 2x2 panel Ultra modern recess mounting luminaire with high performance LEDs, CRCA Housing suitable for mounting with Armstrong/ Grid ceiling Delivers excellent illumination & comfort in high ceiling areas Long life, High transmittance PMMA opal diffuser for glare free symmetric light distribution.Powered by an Built-In electronic driver (SMPS based constant current supply) complete, making connection and testing after fixing all as specified and directed by Engr-in-charge .The specification of the panel light fitting should meet the following:- |
| 59 | (a) Housing of Light fitting : CRCA Powder Coated white after phosphochromate treatment.(b) Operating voltage : 150 V to 240V(c) operating temprature : -10 to 45 degrees(d) Lumen efficacy : Not less than120 lumen per watt(e) system lumen : Not less than 4320 lumens(f) Colour temprature : Not less tha 5700K(g) Surge voltage protection : Up to 2 KV(h) Ingress protection : IP20(j) Total harmonic distortion : not less than 10%(k) Power factor : not less than 0.90 Line protection : Under/ Over voltage protection(l)nput Frequency : 50 HZ Note:- Contractor need to submit NABL approved LM-79, LM-80 along with sample before installation (Sample approval). |
| 60 | Supply and fixing in replacement of 1'x1' LED luminaire 15-20 watts, 4000k,1125lm, 240V white color Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling including all acessories for fixing in false ceiling/ceiling/in hanging position all as specified and directed by Engr-in-Charge. Make:- Havells or equivalent in Crompton/Bajaj Model no- RC360B LED25S-4000 L30W30 PSU OD OR equivalent make as mentioned in Appx 'B' of CA. |
| 61 | Supply and fixing in replacement of PVC gang box 2 WAY suitable for 6 Amp Socket and 6 Amp switch complete all as per specified and directed |
| 62 | Supply and fixing in replacement of PVC gang box suitable for 16 Amp Socket and 16 Amp switch complete all as per specified and directed |
| 63 | Supply and fixing in replacement of PVC Plug Top 6 amps complete all as specified and as directed. |
| 64 | Supply and fixing in replacement of PVC Plug Top 16 amps complete all as specified and as directed. |
| 65 | Supply and fixing in replacement of Distribution modular box with MCB protection Execution (pole) 4 Module and including 20 Amps rating MCB, single pole, AC, 240 volts with Specification as per IS:13032 & IS:8623, (Dimension approx 46.5 x 42.8 x 26 Centimeters), PVC Plastic Material, White Color mounting on wall surface, complete all as directed by Engineer - in - Charge. |
| 66 | Supply and fixing in replacement of modular switch socket combination 16 A, 6 pin, 3 module which includes white cover plate with frame 3 module and PVC Surface mounted box 3 module complete all as specified & directed by Engr-in-Charge. |
| 67 | Supply and fixing in replacement of modular switch socket combination 03 pin 06 A,3 Module which includes white cover plate with frame 3 Module and PVC surface mounted box 3 Module type complete all as specified & directed by Engr-in-Charge. |
| 68 | Supply and fixing in replacement of 15mm dia 304 grade stainless steel connection pipe 450 mm long , suitable for hot & cold water supply ,complete with 2 Nos brass nuts complete all as specified and directed. |
| 69 | Supply and fixing in replacement of 15mm dia 304 grade stainless steel connection pipe 900 mm long , suitable for hot & cold water supply ,complete with 2 Nos brass nuts complete all as specified and directed. |
| 70 | Supply and fixing in replacement of 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10.0 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed. |
| 71 | Supply and fixing in replacement of 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6.0 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed. |
| 72 | Taking down old unserviceable earthing by disconnecting the existing and making good the disturbed surfaces of floor to match the existing complete all as specified and directed by Engineer - in - Charge. |
| 73 | Material and labour for chemical earthing GI earth electrode with medium grade of size 50mm dia upto 2 meter below ground level Installation, testing and commissioning of chemical earthing complete with buried directly in ground vertically to a depth not less than 2mtr below normal ground level earth electrode GI pipe connected to and incl galvanised earthing lead strip 32 x 6mm as main earthing lead by means of tinned copper/ brass bolts, nuts, check nuts and washer beside brazing at all joints as directed and earthing lead protected with 40mm dia light grade GI pipe from electrode and upto incl the earth test point, including alternate layers of 150mm thickness each of charcoal, common salt, magnisium sulphate/ chemical and as per manufacturer's recommendation including below the copper electrode also and excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate, RCC cover 50mm thick in RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia MS deformed bars @75 mm C/C both ways incl MS angle iron frame of size 40mmx40mmx3mm and incl testing the earthing on completioin, complete all as specified. The result of the earth resistance should be less that 1.0 Ohm and recorded results to be submitted to Engr-in-Charge.Note :- (i) Old earthings are conventional type and sch of credit has been accounted for accordingly. (ii) Chemical to be used for earthing should be Marconite. |
| 74 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed. |
| 75 | Taking down old unserviceable Meter Panel by disconnecting the existing and making good the disturbed surfaces of Wall to match the existing complete all as specified and directed by Engineer - in - Charge. |
| 76 | Supply and fixing in replacement of installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make approved in MES list. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. |
| 77 | Contd.. Srl Item No. 54.00:- The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 63A FP 16KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Provision Four Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 4 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel/Rittal/Emitter/Schneider/ABB OR equivalent make as mentioned in Appx 'B' of CA. |
| 78 | Supply and fixing in replacement of installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make approved in MES list. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. |
| 79 | Contd.. Srl Item No. 55.00:- The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 100A FP 16KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Provision Six Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 6 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel/Rittal/Emitter/Schneider/ABB OR equivalent make as mentioned in Appx 'B' of CA. |
| 80 | Supply, installation, testing and commissioning of Tri-Colour LED Strip Light ,operating on 230V AC through suitable LED driver, capable of providing Warm White, Neutral White and Cool White illumination with colour-changing control. The strip shall be flexible, high-efficiency SMD LED type mounted on PCB with adhesive backing, complete with connectors, mounting accessories, driver, controller and all associated wiring as required. The LED strip shall have minimum efficacy of 100 lm/W, CRI ≥ 80, rated life ≥ 50,000 hours, and suitable IP rating as per installation location, complete in all respects as directed by Engineer-in-Charge. Make SURYA OR equivalent make as mentioned in Appx 'B' of CA. |
| 81 | Amount of credit of Rs. 60034.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender