Tender For Repair And Replacement Of Internal Wiring With Connected Accessories Under Ge Nasik Road C .
Tender Value
40 Lakhs
Estimated cost
Bid Submission
23 Sep 2026
4 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Replacement Of Internal Wiring With Connected Accessories Under Ge Nasik Road C .
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Sep-2026 | Revised BOQ | BOQ | 23-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring complete alongwith switch board, casing patti/ PVC conduit removing materials to store and making good to disturb surfaces of wall/floors etc as specified & directed. |
| 2 | M&L Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point/ fan point controlled by one, one way swtich.Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 3 | All as per ser item No. 2.00 herein before but One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. |
| 4 | All as per ser item No. 2.00 herein before but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes. |
| 5 | All as per ser item No. 2.00 herein before but on independent board. |
| 6 | All as per ser item No. 2.00 herein before but one light point controlled by 2 way switches. |
| 7 | All as per ser item No. 2.00 herein before but one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 8 | M&L Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, ISI marked, FRLS type drawn through and including PVC casing and caping (ISI marked) of adequate size and its accessories with PVC boxes, frames for modular fixtures of adequate size, for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point and one fan point controlled by one, one way swtich. |
| 9 | All as per ser item No. 8.00 herein before but One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. |
| 10 | All as per ser item No. 8.00 herein before but on independent board. |
| 11 | All as per ser item No. 8.00 herein before but one light point controlled by 2 way switches. |
| 12 | All as per ser item No. 8.00 herein before but one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 13 | All as per ser item No. 8.00 herein before but with 2.5 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including Fibre insulation boards, treated on one face only of adequate size for mounting purposes. |
| 14 | S&F switch modular type 6 Amps one way, 1 module, AC 230 Volts, shrouded terminal, ISI marked complete all as specified and directed. |
| 15 | S&F modular type socket 6 Amps 3 pin round socket with child safety shutter (ISI marke), AC 230 Volts, shrouded terminals, smooth plug removal and insertion complete all as specified and directed. |
| 16 | S&F switch modular type 16 Amps one way, 1 module, AC 230 Volts, LED based indicator, shrouded terminal, ISI marked complete all as specified and directed. |
| 17 | S&F Modular 20 Amp, Mini MCB SP C Curve, AC 230 Volts, laser marking, ISI marked complete all as specified and directed. . |
| 18 | S&F modular type socket 6 Amps/ 16 Amp 3 pin socket with child safety shutter (ISI marke), AC 230 Volts, shrouded terminals, smooth plug removal and insertion complete all as specified and directed. |
| 19 | S&F modular type bell push 6 Amps, AC 230 Volts, LED based indicator, shrouded terminal, ISI marked complete all as specified and directed. |
| 20 | S&F switch modular type 6 Amps two way, 1 module, AC 230 Volts, LED based indicator, shrouded terminal, ISI marked complete all as specified and directed. |
| 21 | S&F modular type fan 8 step regulator, 100 Watt, AC 230 Volts, 2 module, laser marking complete all as specified and directed. . |
| 22 | S&F modular type telephone socket RJ 11 with Shutter 1 module, laser marking complete all as specified and directed. . |
| 23 | S&F modular type TV socket, 1 module complete all as specified and directed. |
| 24 | S&F in repair switch piano flush button 5 Amp single pole one way 230 Volts white finish all as specified & directed. |
| 25 | S&F in repair socket outlet flush type 3 pin 5 Amp multipurpose 230 Volts single pole one way suitable for 3 pin, 5 Amp plug top white/ivory finish all as specified & directed. |
| 26 | S&F in repair switch socket combination flush type 5 pin 5 Amp multipurpose 230 Volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed. |
| 27 | S&F in repair switch socket combination multipurpose flush type 2 in 1 type (3 and 3 pin) 5/15 Amps, 230V, AC. |
| 28 | S&F in repair bell push, flush type, 5 Amp single pole, 230 Volts white finish all as specified & directed. |
| 29 | S&F in repair switch piano flush button 5 Amp single pole 2 way 230 Volts white finish all as specified & directed. |
| 30 | S&F in repair fan regulator electronic on existing phenolic laminated sheet dimmer type 230 Volts, 450 Watts suitable for ceiling fan 1200/1400mm sweep. |
| 31 | S&F in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with invertor LED bulb 9 Watt complete all as specified and directed |
| 32 | S&F in repair ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish. |
| 33 | S&F in repair buzzer, AC, 230 Volts, single phase complete all as specified and directed. |
| 34 | S&F in repair bell, AC, 230 Volts, single phase complete all as specified and directed. |
| 35 | S&F in repair LED 20 Watt inverter LED batten with rod complete with lithium ion battery with charging time 8-10 hours and backup time upto 4 hours connecting up with three core flexible copper conductor cable of suitable size from ceiling rose. |
| 36 | S&F in repair LED 20 Watt plastic batten with white acrylic cover sleek design complete with connectors and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose. |
| 37 | S&F in repair 30 Watt LED security light fitting luminaire, energy saving and environmental friendly long life LED light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08, including 1.2 RM GI pipe bracket of 40mm dia, connecting up with 2/3 core flexible coppper conductor cable. |
| 38 | S&F in repair LED luminaire 600x600mm, 36 Watt, 220 Volts AC recessed/ surface type fittings, IP 20 with epoxy powder coated CRCA sheet housing with electronic driver, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 39 | S&F in repair LED round shape 15 Watt 220 Volts AC recessed/ surface type with high efficacy PMMA diffuser soft glare free light complete with drivers, clamps and suitable size as per ground requirement complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 40 | S&F in repair invertor LED bulkhead 10 Watt 220 Volts AC with high efficacy PMMA diffuser soft glare free light complete with drivers, clamps with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Make: CP No HLBH-15-10-CW-INV Halonix or equivalent in other models as per CA |
| 41 | S&F in repair LED table lamp 6 Watt 220 Volts AC with high efficacy PMMA diffuser soft glare free light complete with drivers, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 42 | S&F Decorative wall light fitting made up of polycarbonate and aluminium body suitable for and including 10 Watt LED lampcomplete all as specified and directed. |
| 43 | S&F in repair LED square shape 15 Watt 220 Volts AC recessed/ surface type with high efficacy PMMA diffuser soft glare free light complete with drivers, clamps and suitable size as per ground requirement complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 44 | Supply only Decorative LED post top lantern, high PF, 10 Watt, warm white energy saving and environmental friendly long life versatile pressure die cast aluminium housing, 360 degree indirect light, optimum light output, IP 65 protection, glare-free and better uniformty, 240 Volts complete all as specified and directed. |
| 45 | S&F in repair sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified. |
| 46 | S&F in repair submain wiring with four single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 10 Sqmm drawn through in and including PVC heavy duty surface casing caping including 10 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. |
| 47 | S&F in repair submain wiring with four single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 10 Sqmm drawn through in and including PVC heavy duty concealed conduit including 10 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. |
| 48 | S&F in repair submain wiring with four single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including PVC heavy duty surface casing caping including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note for item Srl No 36 to 38 :- (i) Four runs of cables and one run of continuous earting cable drawn in casing and caping will be measured as one length of sub main. (ii) PVC casing caping / PVC conduit and its accessories is deem to be included in this item rates.(iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc. |
| 49 | S&F in repair submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including PVC heavy duty surface casing caping including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. |
| 50 | S&F in repair submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4 Sqmm drawn through in and including PVC heavy duty surface casing caping including 4 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. |
| 51 | S&F in repair submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4 Sqmm drawn through in and including PVC heavy duty concealed conduit including 4 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. |
| 52 | S&F in repair submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 2.5 Sqmm drawn through in and including PVC heavy duty surface casing caping including 2.5 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note for Srl item No 39 to 42 herein before :- (i) Two runs of cables and one run of continuous earting cable drawn in casing and caping will be measured as one length of sub main. (ii) PVC casing caping and its accessories is deem to be included in this item rates.(iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc. |
| 53 | S&F in repair Distribution Board, TPN Vertical (MCCB Incomer) IP43 protection Double Door, 4 way, mechanical impact strength IK 09, suitable for MCCB upto 125 Amps as Incomer (frame 1) complete with 200 Amps rated busbar all as specified and directed. |
| 54 | S&F in repair Distribution Board, TPN Vertical (MCCB Incomer) IP43 protection Double Door, 8 way, mechanical impact strength IK 09, suitable for MCCB upto 125 Amps as Incomer (frame 1) complete with 200 Amps rated busbar all as specified and directed. |
| 55 | S&F in repair distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 415 Volts, 200 Amp rated bus bar with front openable cover suitable for TP & N 4 ways all as specified & directed. |
| 56 | S&F in repair sheet metal enclosures with plug socket triple pole and earth enclosure with three pin and earth plug with socket, 415 Volts complete with one MCB of 63 Amps (TP) complete all as specified. |
| 57 | S&F in repair distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240Volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways all as specified & directed. |
| 58 | S&F in repair distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240Volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways all as specified & directed. |
| 59 | S&F in repair distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240Volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 12 ways all as specified & directed. |
| 60 | S&F in repair 4 Pole MCCB 125 Amp, 50 Hz, 415 V, with adjustable thermal & adjustable magnetic setting, breaking capacity 25 kA. |
| 61 | S&F in repair MCCB 63 Amp TP, 415 Volts 16 kA complete all as specified & directed. |
| 62 | S&F in repair MCB FP 63 Amp, 415 Volts, 50 Hz with 10 kA complete all as specified & directed. |
| 63 | S&F in repair MCB TP 40 Amp, 415 Volts, 50 Hz with 10 kA complete all as specified & directed. |
| 64 | S&F in repair MCB DP/SPN 6-32 Amps, 230 Volts, 50 Hz with 10 kA complete all as specified & directed. |
| 65 | S&F in repair MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 kA complete all as specified & directed. |
| 66 | M&L for in replacement of Earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thickness burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25x25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. |
| 67 | NOTE: AMOUNT OF SCHEDULE OF CREDIT Rs. 97,282.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Sep 23, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysSep 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender