Rural Development Government Departments Closing in 4 days TDR #57303268

Tender For Renovation Of Anganwadi Centre Jaipur Under Govindpur Block In Dhanbad Dist.

Issued by Government Departments · Dhanbad, Jharkhand
Tender Value
8.41 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
4 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
1250
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Anganwadi Centre Jaipur Under Govindpur Block In Dhanbad Dist.

BOQ

Name of Work:- Renovation of Anganwadi Centre Jaipur under Govindpur Block in Dhanbad Dist.
Sl. No. Item Description
1Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
2Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
3Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
4Providing P.C.C,RCC. M-15 with nominal mix of (1:2:4) in foundation -do -do-- all complete job as per specification and & direction of E/I.
5Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
6providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
7Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
8Providing and laying 6mm precast white glazed tiles in walls over 12mm cement motar (1:3)and joined with grey cement slurry with \\"A\\"grade white 15 X15cm tiles.
9Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red
10Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
11Providing designation 75 B Brickwork inC.M(1:6) insuperstructureas per building specification anddirection of E/I
12Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
13Providing 6 mm thick Cement plaster in (1:4) in Ceiling with clean course sand of F.M. 1.5 including the cost of screening, curring with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
14Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
15Providing two coats of synthetic enamel paint of approved shade and make over new wall surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
16Painter Class-I for buildingPainting as per direction of E/I
17New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
18Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
19Providing two coats of synthetic enamel paint of approved shade and make over steel surface including preparing the surface after cleaning removing dust, dirt. scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement of area shall be multiple by the co-efficient as indicated in building specification)
20Providing and laying APP (Atactic Polypropylene Polymer) modifiedprefabricated five layer 3 mm thick water proofing membrane, black finishedreinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemicalparameters of the membrane shall be as under : Joint strength in longitudinaland transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinaland transverse direction as 300/250N. Softening point of membrane not lessthan 150°C. Cold flexibility shall be upto -2°C when tested in accordance withASTM, D - 5147. The laying of membrane shall be got done through the authorisedapplicator of the manufacturer of membrane :
21Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
22Providing 150 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 125 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
23Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
24Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
25Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
26Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
27Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
28Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
29Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. \\"p\\" trap 15 liters C.I. or C. pull and letgo flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathen/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chan and pull inclding supplying and fixing a pair of viterous white lazed earthenware where footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weiht not less than 50 grms. 15mm P.V.C. connection pipe 150mlong and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.
30Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) 15mm dia
3120mm dia
32Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) 25mm dia
33Supplying of brick bat ……..DO……….complete as per direction of E/I. (Approved
34Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, 75 mm diameter
35110 mm diameter
36Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I.
37Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
38Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
39Polythene water storage tank of mark with cover and suitable locking system in double layer confirming to IS :120701-1996 with latest revision
40Providing and fixing Mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. Rectangular shape -450mmx300mm mm
41Providing and fixing c.p. towel rail complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Prayag or equipment)
42Wiring for light/fan point/ exhaust fan point / call bell point with 1.5 Sq mm FRPVC insulated copper conductor single core cable in surface/ recessed PVC conduit with Modular Plate suitable G.I Box and Earthing the point with 1.5 Sq mm FRPVC insulated Copper Conductor single core cable etc asr reqd. Group C
43Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. 2x2.5 Sqmm + 1x2.5 sqmm earth wire
44S/F metal box of 180mm x 100mm x 60 mm deep (nominal size) on surface/recessed with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 Amp socket outlet and 15/16 Amp piano type switch connection etc as required.
45S/F 3 pin, 5 Amp ceiling rose on the existing junction Box /wooden block including connection etc as reqd.
46S/F brass batten/ Angle holder including connection etc as reqd.
47ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
48S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
49ITC exhaust fan upto 450mm sweep:-Installation of exhaust fan upto 450mm, sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc as reqd.
50Supply of 48\\" dia ceiling fan( crompton/havells fan)
51Supply of 12\\" dia Khaitan India exhaust fan
52Supply of 15/16 watt LED bulb
53Earthing with G.I earth pipe 4.5mtr Key & 40mm dia thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as reqd (But without charcoal or coke and salt)
54S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc as required
55P/F of lightning conductor finial made of 25 mm dia 300 mm long copper tube having single prong at top with 85 mm dia 3 mm thick copper base plate incuding holes etc complete as required.
56Reverting sweating and soldering of coper /G.I tape ( with nother copper. G.I tape base of the finial or any toher metalic object) as reqd
57Providing and Fixing G.I tape 20 mm x 3 mm thick on parapet of surface of wall for lightning conductor in horizontal run in complete as reqd
58Providing and Fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor in vertical run complete as reqd
59MV cable laying upto 25sq. Mm in ground -Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of size not exceeding 25sq. Mm . But not exceeding 120sq, mm direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc as required
60Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50 M including all lifts levelling ramming the foundation trenches removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I.
61Filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
62Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per buy lading specification and direction of E/I (Mode of measurement compacted volume).
63Centering and Shutering including strutting propping etc.and remove all Lintels, Beams, Plinth Beam and Girders etc
64Centering and Shutering including strutting propping etc.and remove all Lintels, Beams, Plinth Beam and Girders etc
65Suspended floors roofs landing balconies and access platform
66Providing 50mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved as per building specification and direction of E/I
67Providing designation 75 B Brick work in C.M (1:6) in superstructure as per building specification and direction of E/I
68Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including as per building specification and direction of E/I
69Providing tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved deign and drawing as per building specification and direction of E/I (a) 10mm (TMT coil Fe 500) (only valid for TATA(Tucson), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL)
70Providing two coat snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper. Scaffolding, curing and taxes all complete as pr building specification and direction of E/I
71Providing and laying vetrified floor tiles in different sizes (thickness to be specificed by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622/ISO 13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1;4 *1 cement: 4 Coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete size of Tile 600x600mm
72Supplying fitting and fixing 20 gauge G.C.I. Sheet gate fitted on M.S. Angle frame of size 60x60x6mm. Including cost of fabrication providing necessary locking arrangement with Haskell and downy duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction E/I.
73Providing and laying 6 mm precast white glazed tiles in wall over 12 mm cm(1:3)and joint do-do-E/I(15X15CM)
74(A) 580 mm long (c) with 10 lit. Low level PVC Cistern
75(vi) 15 mm dia brass bib cock(weight not less than 300gms)
76Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL) 15mm dia
77Add Carriage of Material Sand Lead 15 Km
78Brick Lead 10 Km
79Stone Chips Lead 20 Km
80Cement + rod Lead 10 Km
81Providing 12mm thick cement plaster (1:6) as per building specification and direction of E/I
82(a) From 0.00 M to 50.00 M below G.L.
83(b) From 51.0 M to125.00 M
84Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
85Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
86Supplying and commissionig of submersible pump set of reputed KSB/tTexmo make ISI, ISO 9001 marked or having ISO 9001-2000 submersible motor pump for HYDT & head of 100.00m having discharge 4000 l/hour and lowering mm dia PVC submersible schedule 80 pipe & 2.5 sq.mm size finolex copper cable about 80.00 m with main switch 32Amp & panel board sonsisting voltmeter ammeter, on/off switch HRC fuse unit and lighting arrangement, adobter, rope with all complete job as oer specification and direction of E/I2.0 HP
87Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I) including necessary bolts & nuts of requried size complete. 200 mm clamp
88Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Excluding GST) 32 mm nominal outer dia Pipes
89Supply fitting and fixing of standered make starter pannel board with arrangement of all necessary protection including all taxes royality etc. all complete job as per direction of E/I
90FR PVC Insulated 3 Core 4 Sqmm copper wire
91Goods & Service Tax (G.S.T.) -
92Labour Cess - Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57303268
AUTHORITY Government Departments
TENDER VALUE 8.41 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Renovation Of Anganwadi Centre Jaipur Under Govindpur Block In Dhanbad Dist.
Basic Detail
Tender No 26/2026-27/RDSD/EE/Dhanbad/Gr. 19
Bidding Type Tender
Location
City Dhanbad
State Jharkhand
Key Dates
Publish Date 02 Sep 2026
Submission Date 09 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 8.41 Lakhs
Tender Fee 1250
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_159734.xls
d8e3a3e6-4440-4d03-9f17-4e0dd9cf7e37.html
SBD26Gr19.pdf
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_159734.xls

html

d8e3a3e6-4440-4d03-9f17-4e0dd9cf7e37.html

pdf

SBD26Gr19.pdf

pdf

Tendernotice_1 (22).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders