Tender For Renovation Of Anganwadi Centre Jaipur Under Govindpur Block In Dhanbad Dist.
Tender Value
8.41 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
4 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
1250
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Anganwadi Centre Jaipur Under Govindpur Block In Dhanbad Dist.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Providing P.C.C,RCC. M-15 with nominal mix of (1:2:4) in foundation -do -do-- all complete job as per specification and & direction of E/I. |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 6 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 7 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 8 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement motar (1:3)and joined with grey cement slurry with \\"A\\"grade white 15 X15cm tiles. |
| 9 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red |
| 10 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 11 | Providing designation 75 B Brickwork inC.M(1:6) insuperstructureas per building specification anddirection of E/I |
| 12 | Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I. |
| 13 | Providing 6 mm thick Cement plaster in (1:4) in Ceiling with clean course sand of F.M. 1.5 including the cost of screening, curring with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 14 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 15 | Providing two coats of synthetic enamel paint of approved shade and make over new wall surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 16 | Painter Class-I for buildingPainting as per direction of E/I |
| 17 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 18 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 19 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including preparing the surface after cleaning removing dust, dirt. scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement of area shall be multiple by the co-efficient as indicated in building specification) |
| 20 | Providing and laying APP (Atactic Polypropylene Polymer) modifiedprefabricated five layer 3 mm thick water proofing membrane, black finishedreinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemicalparameters of the membrane shall be as under : Joint strength in longitudinaland transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinaland transverse direction as 300/250N. Softening point of membrane not lessthan 150°C. Cold flexibility shall be upto -2°C when tested in accordance withASTM, D - 5147. The laying of membrane shall be got done through the authorisedapplicator of the manufacturer of membrane : |
| 21 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 22 | Providing 150 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 125 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I. |
| 23 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.) |
| 24 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 25 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 26 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 27 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 28 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 29 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. \\"p\\" trap 15 liters C.I. or C. pull and letgo flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathen/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chan and pull inclding supplying and fixing a pair of viterous white lazed earthenware where footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weiht not less than 50 grms. 15mm P.V.C. connection pipe 150mlong and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) 15mm dia |
| 31 | 20mm dia |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) 25mm dia |
| 33 | Supplying of brick bat ……..DO……….complete as per direction of E/I. (Approved |
| 34 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, 75 mm diameter |
| 35 | 110 mm diameter |
| 36 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I. |
| 37 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 38 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 39 | Polythene water storage tank of mark with cover and suitable locking system in double layer confirming to IS :120701-1996 with latest revision |
| 40 | Providing and fixing Mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. Rectangular shape -450mmx300mm mm |
| 41 | Providing and fixing c.p. towel rail complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Prayag or equipment) |
| 42 | Wiring for light/fan point/ exhaust fan point / call bell point with 1.5 Sq mm FRPVC insulated copper conductor single core cable in surface/ recessed PVC conduit with Modular Plate suitable G.I Box and Earthing the point with 1.5 Sq mm FRPVC insulated Copper Conductor single core cable etc asr reqd. Group C |
| 43 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. 2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 44 | S/F metal box of 180mm x 100mm x 60 mm deep (nominal size) on surface/recessed with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 Amp socket outlet and 15/16 Amp piano type switch connection etc as required. |
| 45 | S/F 3 pin, 5 Amp ceiling rose on the existing junction Box /wooden block including connection etc as reqd. |
| 46 | S/F brass batten/ Angle holder including connection etc as reqd. |
| 47 | ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required. |
| 48 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 49 | ITC exhaust fan upto 450mm sweep:-Installation of exhaust fan upto 450mm, sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc as reqd. |
| 50 | Supply of 48\\" dia ceiling fan( crompton/havells fan) |
| 51 | Supply of 12\\" dia Khaitan India exhaust fan |
| 52 | Supply of 15/16 watt LED bulb |
| 53 | Earthing with G.I earth pipe 4.5mtr Key & 40mm dia thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as reqd (But without charcoal or coke and salt) |
| 54 | S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc as required |
| 55 | P/F of lightning conductor finial made of 25 mm dia 300 mm long copper tube having single prong at top with 85 mm dia 3 mm thick copper base plate incuding holes etc complete as required. |
| 56 | Reverting sweating and soldering of coper /G.I tape ( with nother copper. G.I tape base of the finial or any toher metalic object) as reqd |
| 57 | Providing and Fixing G.I tape 20 mm x 3 mm thick on parapet of surface of wall for lightning conductor in horizontal run in complete as reqd |
| 58 | Providing and Fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor in vertical run complete as reqd |
| 59 | MV cable laying upto 25sq. Mm in ground -Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of size not exceeding 25sq. Mm . But not exceeding 120sq, mm direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc as required |
| 60 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50 M including all lifts levelling ramming the foundation trenches removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I. |
| 61 | Filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 62 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per buy lading specification and direction of E/I (Mode of measurement compacted volume). |
| 63 | Centering and Shutering including strutting propping etc.and remove all Lintels, Beams, Plinth Beam and Girders etc |
| 64 | Centering and Shutering including strutting propping etc.and remove all Lintels, Beams, Plinth Beam and Girders etc |
| 65 | Suspended floors roofs landing balconies and access platform |
| 66 | Providing 50mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved as per building specification and direction of E/I |
| 67 | Providing designation 75 B Brick work in C.M (1:6) in superstructure as per building specification and direction of E/I |
| 68 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including as per building specification and direction of E/I |
| 69 | Providing tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved deign and drawing as per building specification and direction of E/I (a) 10mm (TMT coil Fe 500) (only valid for TATA(Tucson), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) |
| 70 | Providing two coat snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper. Scaffolding, curing and taxes all complete as pr building specification and direction of E/I |
| 71 | Providing and laying vetrified floor tiles in different sizes (thickness to be specificed by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622/ISO 13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1;4 *1 cement: 4 Coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete size of Tile 600x600mm |
| 72 | Supplying fitting and fixing 20 gauge G.C.I. Sheet gate fitted on M.S. Angle frame of size 60x60x6mm. Including cost of fabrication providing necessary locking arrangement with Haskell and downy duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction E/I. |
| 73 | Providing and laying 6 mm precast white glazed tiles in wall over 12 mm cm(1:3)and joint do-do-E/I(15X15CM) |
| 74 | (A) 580 mm long (c) with 10 lit. Low level PVC Cistern |
| 75 | (vi) 15 mm dia brass bib cock(weight not less than 300gms) |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL) 15mm dia |
| 77 | Add Carriage of Material Sand Lead 15 Km |
| 78 | Brick Lead 10 Km |
| 79 | Stone Chips Lead 20 Km |
| 80 | Cement + rod Lead 10 Km |
| 81 | Providing 12mm thick cement plaster (1:6) as per building specification and direction of E/I |
| 82 | (a) From 0.00 M to 50.00 M below G.L. |
| 83 | (b) From 51.0 M to125.00 M |
| 84 | Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia. |
| 85 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 86 | Supplying and commissionig of submersible pump set of reputed KSB/tTexmo make ISI, ISO 9001 marked or having ISO 9001-2000 submersible motor pump for HYDT & head of 100.00m having discharge 4000 l/hour and lowering mm dia PVC submersible schedule 80 pipe & 2.5 sq.mm size finolex copper cable about 80.00 m with main switch 32Amp & panel board sonsisting voltmeter ammeter, on/off switch HRC fuse unit and lighting arrangement, adobter, rope with all complete job as oer specification and direction of E/I2.0 HP |
| 87 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I) including necessary bolts & nuts of requried size complete. 200 mm clamp |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Excluding GST) 32 mm nominal outer dia Pipes |
| 89 | Supply fitting and fixing of standered make starter pannel board with arrangement of all necessary protection including all taxes royality etc. all complete job as per direction of E/I |
| 90 | FR PVC Insulated 3 Core 4 Sqmm copper wire |
| 91 | Goods & Service Tax (G.S.T.) - |
| 92 | Labour Cess - Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer