Tender For Rev Ing Of Class-4 Power Distribution System In Coral, Rpg, Igcar, Kalpakkam
Tender Value
99.02 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
16 days left
EMD
1.98 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rev Ing Of Class-4 Power Distribution System In Coral, Rpg, Igcar, Kalpakkam
BOQ
| Sl. No. | Item Description |
| 1 | Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5) |
| 2 | 3/3.5/4 Core upto 25 Sqmm |
| 3 | 3/3.5/4 Core Above 25 & Upto 120 Sqmm |
| 4 | 3/3.5/4 Core Above 120 & Upto 240 Sqmm |
| 5 | 3/3.5/4 Core Above 240 & Upto 400 Sqmm |
| 6 | Removal of termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination |
| 7 | Sizes above 4C X 25 sq.mm and upto 4C X 70 sq.mm |
| 8 | Sizes above 3.5/4C X 120 Sq.mm and up to 3.5/4C X 185 Sq.mm |
| 9 | Sizes above 3.5/4C X 240 Sq.mm and up to 3.5/4C X 400 Sq.mm |
| 10 | End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 11 | 3.5 x 185 sq.mm |
| 12 | 3.5 x 240 sq.mm |
| 13 | 3.5 x 300 sq.mm |
| 14 | 3.5 x 400 sq.mm |
| 15 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). |
| 16 | MS fabrication 1 coat primer & 2 coats synthetic enamel paint |
| 17 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 18 | 3/3.5/4core X Upto 25 sqmm |
| 19 | 3/3.5/4Core X above 25 & up to 120 sqmm |
| 20 | 3/3.5/4Core X above 120 & up to 240 sqmm |
| 21 | 3/3.5/4Core X above 240 & up to 400 sqmm |
| 22 | Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 23 | 3/3.5/4CX Above 120 Sq.mm but not exceeding 3.5/4CX 240 sq.mm |
| 24 | Supply, fabrication and installation of the following size of Copper Flats including excavation and refilling as per the detailed specification. (Refer Sec VI, Clause No.12.7). |
| 25 | 25X3 mm Copper flat |
| 26 | Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2) |
| 27 | Temporary connection / disconnection of 415 Volt equipment like welding machine etc as per scope of work. |
| 28 | Supply, fabrication and installation of the following size of Copper Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. (Refer Sec VI, Clause No.12.7). |
| 29 | 25X3 mm Copper flat |
| 30 | Supply and installation of Hume Pipe Laying across the road. (Refer Sec VI, Clause No.8.2). |
| 31 | Supply and installation of 230 mm Dia. 2 Mtrs Long, NP 2 Class Hume Pipes at a depth of 1200 mm including supply of Collars and fixing them with1:1 cement mortar and curing, including cutting for crossing of existing road and excavation of all types of soil, backfilling, normalisation of road etc complete as directed by Engineer-in-Charge. |
| 32 | Plain Cement Concrete.(Refer Sec VI, Clause No.26) |
| 33 | 1:2:4 Plain Cement Concrete |
| 34 | Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Crimping type) for 3.5 Core Aluminium Conductor, 1.1 kV (E), PVC/XLPE insulated cables of following sizes as specified. Excavation will be measured separately (Refer Sec VI, Clause No.10.6). |
| 35 | Straight Through Joint (Crimping type) for 3.5 Core, 25- 50 Sq. mm |
| 36 | Straight Through Joint (Crimping type) for 3.5 Core 120- 185 Sq. mm |
| 37 | Straight Through Joint (Crimping type) for 3.5 Core x 400 Sq. mm |
| 38 | Dismantling and cutting of MS cable drums into pieces shall be carried out as part of scrap disposal, as per the scope of work and as directed by the EIC.Shifting of scrap shall be treated as a separate item.(Refer Sec VI (MNC),Clause No.35) |
| 39 | Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28). |
| 40 | Supply and installation of GI cable tray as per the technical specification (Refer Section V) |
| 41 | 300 mmx100 mmx2.0 mm thick ladder type tray |
| 42 | Supply and installation of GI cable tray cover as per the technical specification (Refer Section V) |
| 43 | 300 mmx100 mmx2.0 mm thick cover |
| 44 | Design, fabrication, supply, removal of existing PCC, installation , (Excluding MS supporting structure at the trench) testing and commissioning of the 415V Class-4 PCC panel at CORAL Substation. |
| 45 | Supply, installation, testing and commissioning of DC 110V, 25A, Float Cum Boost Charger with DCDB, Suitable for 110V, 100AH VRLA Battery. |
| 46 | Supply, installation, testing and commissioning of 110V, 100Ah @1.75ECV VRLA Battery With a Rack (55Cells) and inter connecters. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender