Tender For Up-Gradation Of Zorawar And Shivaji Hall Of Training Centre At Nsg C Manesar.
Tender Value
6.10 Crore
Estimated cost
Bid Submission
16 Sep 2026
1 days left
EMD
12.20 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Up-Gradation Of Zorawar And Shivaji Hall Of Training Centre At Nsg C Manesar.
BOQ
| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 3 | All kinds of soil |
| 4 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 5 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. |
| 6 | CONCRETE WORK |
| 7 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth. |
| 8 | 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources). |
| 12 | REINFORCED CEMENT CONCRETE |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 14 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 17 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 19 | Suspended floors, roofs, landings, balconies and access platform |
| 20 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 22 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 23 | MASONARY WORK |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 25 | Cement mortar 1:6(1 cement :6 coarse sand) |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 27 | Cement mortar 1:6(1 cement : 6 coarse sand) |
| 28 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 29 | Cement mortar 1:4(1 cement :4 coarse sand) |
| 30 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 31 | CLADDING WORK |
| 32 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 33 | Granite stone slab of colour black, Cherry/Ruby red |
| 34 | Area of slab upto 0.50 sqnn |
| 35 | Area of slab over 0.50 sqm |
| 36 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 37 | Granite work |
| 38 | WOOD AND P.V.C. WORK |
| 39 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 40 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 41 | 200x10 mm |
| 42 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 43 | 200 mm |
| 44 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 45 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 46 | Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 47 | Fixed window/ ventilator without mullion /transom. |
| 48 | Using R1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre) |
| 49 | STEEL WORK |
| 50 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 51 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 52 | Hot finished welded type tubes |
| 53 | FLOORING |
| 54 | Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400 mm of all colours and shades. |
| 55 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3kg/sqm |
| 56 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. |
| 57 | ROOFING |
| 58 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 59 | 110 mm diameter |
| 60 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 61 | Coupler |
| 62 | 110 mm |
| 63 | Single tee with door |
| 64 | 110x110x110 mm |
| 65 | Single tee without door |
| 66 | 110x110x110 mm |
| 67 | Bend 87.5° |
| 68 | 110 mm bend |
| 69 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 70 | 110 mm |
| 71 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'S or 'L' hooks, bolts & nuts 8 mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafers, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. |
| 72 | 2 mm thick corrugated (2.5\\" 0r 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\" ) as specified |
| 73 | FINISHING |
| 74 | 12 mm cement plaster of mix: |
| 75 | 1:6 (1 cement: 6 coarse sand) |
| 76 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 77 | 1:6(1 cement: 6 coarse sand) |
| 78 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: |
| 79 | 1:4(1 cement: 4 fine sand) |
| 80 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 81 | New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 82 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 83 | Two or more coats on new work |
| 84 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 85 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 86 | REPAIR TO BUILDINGS |
| 87 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 88 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 89 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 90 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. |
| 91 | DISMANTLING AND DEMOLISHING |
| 92 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 93 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 94 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 95 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 96 | In cement mortar |
| 97 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 98 | Of area beyond 3 sq. metres |
| 99 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 100 | For thickness of tiles 10 mm to 25 mm |
| 101 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 102 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. |
| 103 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50metres lead : Up to 10 mm thick |
| 104 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 105 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 106 | 100 mm dia pipe |
| 107 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 108 | 15 mm to 40 mm nominal bore |
| 109 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: |
| 110 | Up to 150 mm diameter |
| 111 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 112 | ROAD WORK |
| 113 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 114 | 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 115 | SANITARY INSTALLATIONS |
| 116 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 117 | WATER SUPPLY |
| 118 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 119 | 20 mm nominal dia Pipes |
| 120 | 25 mm nominal dia Pipes |
| 121 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall |
| 122 | 20 mm dia nominal bore |
| 123 | 25 mm dia nominal bore |
| 124 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 125 | 45 cm length |
| 126 | 15 mm nominal bore |
| 127 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 128 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 129 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 130 | 20 mm nominal bore |
| 131 | 25 mm nominal bore |
| 132 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 133 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 134 | 15 mm nominal bore |
| 135 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 136 | 15 mm nominal bore |
| 137 | DRAINAGE |
| 138 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 139 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 140 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 141 | ALUMINIUM WORK |
| 142 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 143 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 144 | With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 145 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer- in-charge. |
| 146 | With stainless steel cover plate minimum 1.25 mm thickness |
| 147 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 148 | WATER PROOFING |
| 149 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 150 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 151 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
| 152 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 153 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 154 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 155 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 156 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 157 | 30 mm thick |
| 158 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 159 | Frame size 65 x 125 mm |
| 160 | Add correction factor 0.973 (i.e. 2.70%) on DSR items @ total of DSR rates x 2.70% i.e. 11192729.81X2.70%= -302203.70 |
| 161 | Add Cost index on DSR 2023 @ 4.03%on 10890526.11= 438888.20 |
| 162 | NON-SCHEDULE ITEMS |
| 163 | Providing and fixing Door lock patch fitting on existing Toughened glass shutter complete as per the architectural drawings and the directions of engineer-in-charge . |
| 164 | Providing and fixing Stainless steel H -type handle on existing toughtend glass shutter including holing/drilling etc all complete as per the directions of engineer-in-charge . |
| 165 | Providing and fixing Outdoor golden LED Signage \\"Zorawar Hall\\" and both side Logo (NSG EMBLEM) make of stainless steel 304 grade, 20 guage, Letter Size 15`` logo size 24x24``, depth approx 1.75 to 2``, PVD coated acrylic 010 3mm back side double channel letter with LED lighting of 3 year warranty, warm white colour including power supply fixures etc of one year warranty including drilling , holling in granite/RCC etc all complete as per direction of Engineer In charge. |
| 166 | Providing and fixing Outdoor golden LED Signage \\"Shiwaji Hall\\" and both side Logo (NSG EMBLEM) make of stainless steel 304 grade, 20 guage, Letter Size 15`` logo size 24x24``, depth approx 1.75 to 2``, PVD coated acrylic 010 3mm back side double channel letter with LED lighting of 3 year warranty, warm white colour including power supply fixures etc of one year warranty including drilling , holling in granite/RCC etc all complete as per direction of Engineer In charge. |
| 167 | Providing & fixing of 06mm thick both side High pressure Exterior Grade laminate of approved quality & make . These are EN 438-Part 6 complying panels, which are manufactured by high pressure and temperature in a hot press. The core of the panel consists of desired numbers of imported, long fibre virgin kraft papers, impregnated with specially formulated double hardened Phenolic resin and another top layer of imported virgin Blue wool scale passed, decorative paper layer impregnated with melamine resin. The panels are flame retardant type class 1 as per BS:476 Part 7, ASTM E84 and EN 438-Part 6. Poly-methyle methacrylate UV protecting films are provided at the top of the Deco layer for optimum UV protection (passes 1500Hrs). HPL panels have a tested Flexural Modulus of ≥ 11,000 MPa and Flexural strength of ≥ 100 MPa which makes the product enormously sturdy from inside. This product shows no distortion in extreme climatic changes such as from -20°C to +80°C or from dry climate to a relative humidity in excess of 85% - 90%. HPL panels are equipped with a maximum possible weather resistance at extreme oceanic climates as it has duly passed the salt spray test conducted for 500 Hours. HPL panels pass a 3000 hours artificial weathering and are rated with a 5 for Grey scale rating & 7/8 for Blue wool rating. Density is 1.45gm/cm3 with 10 years warranty the cladding system will be installed on aluminium frame work on wall or other surface for making grid of maximum size of 600x600mm(c/c) as frame work wall lining work using rectangular section of size 38.10x25.40x1.44mm or other equivalent sections of approved make conforming to IS:1285 i/c providing & fixing with SS Anchor/dash/wedge fasterners or required dia nd size, scaffolding etc. Aluminium sections shall be smooth , rust free, straight, mitres or unshared and jointed mechanically wherever required including cleat angle,etc. all complete as per architectural drawing and as per direction of engineer-in-charg.Installation will be done via rivets/adhesive and 3M tape. |
| 168 | Providing and fixing Premium quality GRC cobbles of size not less than 150x150x22 mm of approved design and shape laid in required colour and pattern in footpath & courtyard etc jointed with neat cement slurry mixed with pigment to match the shade of tiles, including cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 169 | Providing and fixing Premium quality Glazed vitrified wall tiles polished finish of size (GVT) size not less than 600x1200 with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 170 | Providing and fixing 'Unistone', make or equivalent Glass Reinforced Concrete (G.R.C) Screens casted with 'Spray Mix' concrete design in approved size, pattern, thickness of 50mm on the outer Border & 25-30mm for Internal member or overall thickness of 40mm and shade. The Screens should be made from ‘43 grade’ Portland Cement manufactured by ‘JK Cement’ or ‘Nuvoco’ or ‘JK Lakshmi’ or Ultratech', White Quartz fine graded sieve Silica Sand, Alkali Resistant Glass Fibre manufactured by 'NEG Japan, Owen Corning ‘Saint Gobain’ or equivalent, Super Plasticizers manufactured by ‘Karochem’ or equivalent, Polymers manufactured by ‘Nova Polychem’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘Phenochem industries or equivalent. The Screens casting shall take place with layering methodology using- Direct Power Spray machines. The GRC Screens flexural strength average L.O.P should be above or equivalent to 6 N/mm² & M.O.R should be above or equivalent to 12 N/mm² for tests done on 28 days cured samples. The fixing of Screens should be done using ‘Dry fixing’ method onto structural support members i.e. R.C.C, Brick work MS Framework. MS Galvanized CLAMPS & PINS also if required fasteners to be used of Wurth, Hilti & Fischer or equivalent. ALL CAST in SOCKET TO BE EPOXY PRIMER COATED. ELECTRODES to be used of ADVANI, MANGALAM, ESAB OR Victor brand or equivalent. Vendor shall submit shop drawings of same, the drawings to be duly approved from Engineer in charge at site. |
| 171 | Providing and fixing of Fabric Acoustical Wall Paneling in all heights with square edges made of Rockwool with Glasswool Tissue substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colors as per the choice of the Architect/ Engineering- in charge of size 600x1200 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC. The GI stud system includes G.I Stud having Size 48 mm X 36 mm X 34 mm X 0.50mm, length 3600mm, and Floor Channel Size 50 mm X 32 mm X 32 mm X 0.50 mm, length 3600 mm is fastened vertically/ horizontally at every 600mm filled with 50mm 1000GSM non-woven thermal bonded polyester wadding. Then 8 mm Gyptech HDMR Board Perforated strips of 100 mm should be Screwed to the GI frame with the help of 25 X 6 mm metal screw 25mm thick fabric acoustical panel should be pasted on the 8 mm HDMR Board strips with the help of rubber base Adhesive including scaffolding etc complete as per drawing and design approved by Engineer-in-Charge. Make: Armstrong / Anutone/Gyptech or equavalent (Manufacturer Company MTC along with NRC certificate would be required at the time of installation). |
| 172 | Providing and fixing uPVC soffit panel of size 288mm width and 1.5mm thick in wall lining on existing aluminium frame work. Panel should have one side decorative other side balacing design, with necessary fixing arrangment and screw etc and as per direction of engineer in charge. |
| 173 | Providing and fixing white vitreous china table top wash basin of catagery JDS-WHM-25907N of Jaquar make or equavalent series of make cera, hindware, Parryware with 32mm CP Brass Waste of standard pattern including making all connections : Italian collection as per direction of engineer in charge Table Top Basin, In White Matt of Size: 530x420x140 mm, Shape - Rectangular as per direction of engineer in charge all complete |
| 174 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of Size: 370x665x750 mm of catagery CNS-WHT-853S220SPPSM of Jaquar make or equavalent series of make cera, hindware, Parryware including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 175 | Providing and fixing single lever Basin mixture of catagery KUP-35005BPM of Jaquar make or equavalent series of make cera, hindware, Parryware including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 176 | Providing & Fixing toilet cubicals of approved make e.g.Greenlam, Action tesa or Duro etc of size 1303x1500x1885 with thickness of panels is 12mm and door size 600x1730 make solid compact laminate consists of layer of cellulose fibrous materal impregnated with thermosetting resin and bonded togther by the high pressure process. the surface of the both side, having decorative colours or design, are impregnated with melamine based resins. including SS 316 round top rail, Noise deafening tape, SS 316 coat Hook with Stopper, SS 316 concealed hinge ,SST 316 door knob, SST 316 door stopper channel SS 316 head rail, tabular holder, SS hollow section wall bracket, SS 316 screw, SS 316 shoe box side cover, SS 316 thumb turn lockset & U channel, complete in all respect as per direction of Engineer-in-Charge. |
| 177 | Excavating, supplying and filling of Malba by mechanical transport upto a lead of 5km also including ramming and watering of the malba in layers not exceeding 20 cm in floor, trenches, plinth, sides of foundation etc. complete. |
| 178 | Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows/ventilators/ wall paneling with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size including sacffolding etc. (Dash fastener to be paid for separately). |
| 179 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800x2400 mm |
| 180 | Less credit for the unserviciable/dismantled Galvanized iron items during execution of the work. |
| 181 | Electrical |
| 182 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 183 | Group C |
| 184 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 185 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 186 | Group A |
| 187 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 188 | Group C |
| 189 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 190 | 2 X 1.5sq.mm-+ 1X 1.5 sq. mm earth wire |
| 191 | 2 X 4sq.mm+ 1X4 sq. mm earth wire |
| 192 | 4 X 4sq.mm +2 X 4 sq. mm earth wire |
| 193 | 2 X 6sq.mm+ 1X6 sq. mm earth wire |
| 194 | 4 X 6sq.mm+ 2X6 sq. mm earth wire |
| 195 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 196 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 197 | 3 x 1.5 sq. mm |
| 198 | 6 x 1.5 sq. mm |
| 199 | 9 x 1.5 sq. mm |
| 200 | 3 x 4 sq. mm |
| 201 | 6 x 4 sq. mm |
| 202 | 9 x 4 sq. mm |
| 203 | 3 x 6 sq. mm |
| 204 | 6 x 6 sq. mm |
| 205 | 9 x 6 sq. mm |
| 206 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 207 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 208 | 20 mm |
| 209 | 25 mm |
| 210 | 32 mm |
| 211 | 50 mm |
| 212 | Supplying and installing following sizes of Hot Dipped Galvanised Iron floor trunking (galvanisation thickness not less than 50 microns) with GI top cover, GI fixing brackets and joined with couplers/connectors on the existing floor trench etc. as required. |
| 213 | 225 mm width X 38 mm depth X 1.6 mm thickness |
| 214 | 300 mm width X 38 mm depth X 1.6 mm thickness |
| 215 | Supplying and fixing of following sizes of height adjustable GI Junction boxes ( 1.6 mm thick GI sheet ) with base & cover plate in existing metal raceway sytem and anchoring it to the flooring etc as required. |
| 216 | 225 x 225 x 65 - 90 mm |
| 217 | 300 x 300 x 65 - 90 mm |
| 218 | Supplying and fixing of following sizes of height adjustable GI Junction boxes ( 1.6 mm thick GI sheet ) having fly over with base & cover plate in existing metal raceway sytem anchoring it to the flooring etc as required. |
| 219 | 225 x 225 x 65 - 90 mm |
| 220 | Supplying and fixing of following sizes of verticlal GI risers ( 1.6 mm thick GI sheet ) in existing metal raceway sytem and anchoring it to the flooring/wall etc as required. |
| 221 | 300 x 300 x 65 - 90 mm |
| 222 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 223 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 224 | 1 run of cable |
| 225 | 2 run of cable |
| 226 | 3 run of cable |
| 227 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 228 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 229 | 4 way (4 + 12), Double door |
| 230 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 231 | 4 way (4 + 12), Double door |
| 232 | 6 way (4 + 18), Double door |
| 233 | Supplying and fixing following rating, four pole, 415 volts, MCCB suitable for mounting in the existing Vertical TPN MCB DB complete with connections, testing and commissioning etc. as required. |
| 234 | 63 Amp 'C' Curve, 10/18kA |
| 235 | 100 Amp 'C' Curve, 18/25 kA |
| 236 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 237 | Single pole |
| 238 | Single pole and neutral |
| 239 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 240 | 32 A, Triple pole |
| 241 | 40 A, Triple pole |
| 242 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 243 | 25 amps |
| 244 | 40 amps |
| 245 | 63 amps |
| 246 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 247 | 1 output per phase and suitable for single phase supply |
| 248 | Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 249 | Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 250 | 3.5 x 50 sqmm |
| 251 | 3.5 x 120 sqmm |
| 252 | 3.5 x 150 sqmm |
| 253 | Supplying, Laying and fixing of one number copper conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size on wall surface/Cable tray as required. |
| 254 | 4c x 25 sq. mm |
| 255 | 4c x 16 sq. mm |
| 256 | 4c x 10 sq. mm |
| 257 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 258 | 1 or 2 Module (75mmX75mm) |
| 259 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 260 | Telephone socket outlet |
| 261 | Supplying, Laying and fixing of one number stranded copper conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing PVC/ METAL pipe as required. |
| 262 | 3 c x 2.5 sq. mm (communication cable for ODU & IDU) |
| 263 | 4 c x 4.0 sq. mm (power cable IDU) |
| 264 | 4 c x 10.0 sq. mm (power cable ODU) |
| 265 | 4 c x 16.0 sq. mm (power cable ODU) |
| 266 | Supplying and fixing of following sizes of flexible steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 267 | 20 mm |
| 268 | 25 mm |
| 269 | Supplying and fixing following sizes DLP U-PVC trunking with cover, separator partition and accessories (Joints, Angles, Bends, End Caps, Brackets, Junctions etc) on surface etc complete as required. |
| 270 | 105 mm x 50 mm (2 compartments) |
| 271 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conformingto IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.,complete as required. |
| 272 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 273 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 274 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 275 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 276 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 277 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 278 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 279 | The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground tilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of xcavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length.i) Upto 200 mm dia DWC HDPE / G.I. /PVC |
| 280 | Supplying installation testing and commissioning of 400mm sweep wall fan with thermal overload motor protection, delivery rate 85 CMM at 1330 rpm (or better) suitable for operation on 220-240V and 50Hz Ac supply etc required. |
| 281 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 282 | 4 X 25 sq. mm (28mm) |
| 283 | 4 X 16 sq. mm (28mm) |
| 284 | 4 X 10 sq. mm (25mm) |
| 285 | 3.5 x 50 sqmm (35mm) |
| 286 | 3.5 x 120 sqmm (45mm) |
| 287 | 3.5 x 150 sqmm (50mm) |
| 288 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty of Atomberg/ Usha/ Orient / Havells /Crompton make) |
| 289 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 290 | Supply, installation, testing and commissioning of COB Recessed LED downligh with DALI enabled driver delivering system lumen >2600 lumens & the luminaire shall be with system efficacy ≥ 110 Im / W. in PD aluminium powder coated white, wide beam angle and operating CCT ≥5000K , input voltage range of 140 to 270V ,THD ≤ 10% & PF ≥ 0.95, Life-50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 6KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer. [Make- LT Model No. INTENSO G5 MAX or equivalent in Havells/Regent/Phillips] |
| 291 | Supply, installation, testing & commissioning of LED (Warm Light) Single Phase Track Mounted DALI enabled Light fixture , housing made up of Die-cast Aluminium with PC/Glass Diffuser delivering a minimum system lumens of 1000 lumens and minimum system luminous efficacy of 100 lm/W, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, suitable for mounting on single phase 3 wire universal track system including connections and earthing etc. as required. |
| 292 | Supply, installation, testing & commissioning of LED (Warm Light) Single Phase Track Mounted Light fixture , housing made up of Die-cast Aluminium with PC/Glass Diffuser delivering a minimum system lumens of 1000 lumens and minimum system luminous efficacy of 100 lm/W, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, suitable for mounting on single phase 3 wire universal track system including connections and earthing etc. as required. |
| 293 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1200 mm (nominal size) with a minimum system lumen output of 2400 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 294 | Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required. |
| 295 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 600 mm (nominal size) with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 296 | Supply, installation, testing and commissioning of surface mounted LED downlighter luminaire in metallic housing, with a minimum system lumen output of 1800 lumen and with a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required. |
| 297 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 298 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 299 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 300 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 301 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 302 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 303 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 304 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 305 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 306 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 307 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 308 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 309 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 310 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 311 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 312 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 313 | Supply, installation, testing and commissioning of DIN-Rail Mount type, 2400mA Power Supply Module for Over Voltage and Short Circuit protection having DC/COM/DATA Connection ports suitable to operate on 110V/220V, 50-60Hz AC supply delivering Output current of 2400mA at 24V DC etc as required. |
| 314 | Supply, installation, testing and commissioning of smart Multi-function touch panel in ABS,PC hosuing alogwith suitable Panel power interface for operation on 12-30V DC supply with following features : Key Mode: Single on/off, Single on, Single off, Combi-nation on, Combination off, Combination on/off, Double click single on/off, Double click combination on/off.Key Control Type: Scene, Sequence, Timer, Universal Switch, Single Channel Control, Broadcast Scene, Broadcast Channel, Curtain Control, GPRS Control, Panel Control, Security Module etc.Button Lock, mutually exclusive function.Customized Button labels and replaceable plate.Supports online upgrading. |
| 315 | Supply, installation, testing and commissioning of DIN-Rail Mount type, 64 Channel DALI controller in PC housing suitable for operation on 15-30 V DC supply.The controller shall be able to support 64 DALI lightning equipments, in 16 separate areas with dimming and scene control.The controller shall have built in DALI power supply and short-circuit protection for DALI wires. |
| 316 | Supply, installation, testing and commissioning of DIN-Rail Mount type, 1-port IP interface panel in PC Housing suitable for 15-30 V DC working voltage, RJ45 Signal interface, RJ-45 to UDP/IP network interface.The IP interface should be able to support local control, p2p control, remote control (local control by default), local network and shall allow atleast 4 devices to connect this module for remote control. |
| 317 | Supply, installation, testing and commissioning of DIN-Rail Mount type, Logic Module in PC Housing suitable for 15-30 V DC working voltage having provision of 240 logic blocks and logic inputs like channel status,year, date, week, time, external input value, sequence status, channel status, panel status, security etc. The controller shall have built-in real-time clock and online upgradation of the module shall be available. |
| 318 | Supply, installation, testing & commissioning of 20 KVA True online UPS (with 30 min back up) having 3 phase 4 wire input & 3 phase 4 wire output including sealed maintenance free batteries & duly painted heavy duty angle iron rack.The system shall be suitable for operation on input voltage range of 340-460 V & output voltages of 415/400/380V (adjustable) with + 1% of regulation, overload capacity of 10% for 1 min and suitable to operate in temperature range of 0-40 C including connection etc.as reqd. The entire UPS system (including batteries) should have a warranty of minimum 2 years. [Make- Nexus Power Sytems/Emerson/ETon/3 EM , battery make Amron / Quanta/Exide |
| 319 | Essential Feeder Panel |
| 320 | Fabrication, supply, installation, testing & commissioning of,Electrical panel of cubical construction with front facia of minimum 1.98 sqm, double door, outdoor floor-mounted type with slanted roof, fabricated out of 2 mm thick CRCA sheet, with enclosure protection class IP 54, suitable for operation on 415-volt, 50 Hz, 3 phase, 4 wire A.C. supply system, dust and vermin proof, powder-coated in an approved siemens grey shade after 7 tank treatment processes, compartmentalized with hinged lockable doors, detachable cable gland plates made of 3 mm thick |
| 321 | CRCA sheet, cable alleys of suitable size for cable routing, openable type rear cover and complete with 4 strips of Aluminium bus bars of 200 Amps capacity with heat-shrinkable coloured sleeves and DMC/SMC bus bar supports at required intervals, control terminals, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection with suitable sized solid aluminium strip/ bus Bar and control wiring with suitable sized insulated copper conductor cable. |
| 322 | The entire panel shall have one common aluminium/ G.I. bar of size 20 mm x 5 mm at the rear with 2 earth studs/terminals. A suitable size M.V. Danger Board shall be fixed on the panel. The panel base should have four 300 mm long legs (made of angle irons 50 x 50 x 6 mm) to raise the panel from the floor. The base frame of the panel should be grouted into the floor with four bolts and nuts. The panel shall have provision to accommodate the following switch gears as mentioned below and as per the drawing approved by the engineer-in-charge with the required front area and minimum depth of 300 mm. (Drawings will be approved by the Engineer-in-Charge before fabrication of the panel). |
| 323 | Providing and fixing following switch gears, meters and accessories in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 324 | Incomer |
| 325 | 125 Amp, 4-pole, MCCB, 25 kA breaking capacity, Ics = 100% Icu with TM release, Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 1 Nos. |
| 326 | Extended Rotary Handle (RHOM) for 125 A MCCB-1 Nos. |
| 327 | MCB SP, 10 KA, 6 AMP for Control circuit. ( L&T/Legrand / Siemens /ABB/ Schneider) - 3 Nos. |
| 328 | Digital Multifunction Meter (L&T/Legrand/Siemens/ABB/Schnieder) - 1 Nos. |
| 329 | R, Y, B LED phase indicating lamps (L & T, Siemens, BCH, Telemecanique, Vaishnav, Kaypee/ESS-BEE) - 3 Nos. |
| 330 | CTs 200/5 A amps, 15 VA with class 1.0 accuracy. (AE /KAPPA/Trinity)- 3 Nos. |
| 331 | Outgoing |
| 332 | 40 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 5 Nos. |
| 333 | Direct Rotary Handle (RHOM) for 63 A MCCB - 5 Nos. |
| 334 | Non-Essential Feeder Panel |
| 335 | Fabrication, supply, installation, testing & commissioning of,Electrical panel of cubical construction with front facia of minimum 2.52 sqm , double door, outdoor floor-mounted type with slanted roof, fabricated out of 2 mm thick CRCA sheet, with enclosure protection class IP 54, suitable for operation on 415-volt, 50 Hz, 3 phase, 4 wire A.C. supply system, dust and vermin proof, powder-coated in an approved siemens grey shade after 7 tank treatment processes, compartmentalized with hinged lockable doors, detachable cable gland plates made of 3 mm thick |
| 336 | CRCA sheet, cable alleys of suitable size for cable routing, openable type rear cover and complete with 4 strips of Aluminium bus bars of 300 Amps capacity with heat-shrinkable coloured sleeves and DMC/SMC bus bar supports at required intervals, control terminals, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection with suitable sized solid aluminium strip/ bus Bar and control wiring with suitable sized insulated copper conductor cable. |
| 337 | The entire panel shall have one common aluminium/ G.I. bar of size 20 mm x 5 mm at the rear with 2 earth studs/terminals. A suitable size M.V. Danger Board shall be fixed on the panel. The panel base should have four 300 mm long legs (made of angle irons 50 x 50 x 6 mm) to raise the panel from the floor. The base frame of the panel should be grouted into the floor with four bolts and nuts. The panel shall have provision to accommodate the following switch gears as mentioned below and as per the drawing approved by the engineer-in-charge with the required front area and minimum depth of 300 mm. (Drawings will be approved by the Engineer-in-Charge before fabrication of the panel). |
| 338 | Providing and fixing following switch gears, meters and accessories in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 339 | Incomer |
| 340 | 200 Amp, 4-pole, with operating handle. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 1 Nos. |
| 341 | 200 Amp, 4-pole, MCCB, 36 kA breaking capacity, Ics = 100% Icu with TM release, Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 1 Nos. |
| 342 | Extended Rotary Handle (RHOM) for 125 A MCCB-1 Nos. |
| 343 | MCB SP, 10 KA, 6 AMP for Control circuit. ( L&T/Legrand / Siemens /ABB/ Schneider) - 3 Nos. |
| 344 | Digital Multifunction Meter (L&T/Legrand/Siemens/ABB/Schnieder) - 1 Nos. |
| 345 | R, Y, B LED phase indicating lamps (L & T, Siemens, BCH, Telemecanique, Vaishnav, Kaypee/ESS-BEE) - 3 Nos. |
| 346 | CTs 200/5 A amps, 15 VA with class 1.0 accuracy. (AE /KAPPA/Trinity)- 3 Nos. |
| 347 | Outgoing |
| 348 | 125 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 2 Nos. |
| 349 | Direct Rotary Handle (RHOM) for 125 A MCCB - 2 Nos. |
| 350 | 80 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 4 Nos. |
| 351 | Direct Rotary Handle (RHOM) for 80 A MCCB - 4 Nos. |
| 352 | Audio Video |
| 353 | Supply Installation Testing & Comissioning of loudspeaker that shall be a compact, high-performance, passive minimum 2-way system employing dual 8\\" drivers in a coaxial-plus-dedicated-LF configuration with 1.4\\" voice coil compression driver, delivering minimum 300W AES continuous / 1200W peak power handling, 8Ω impedance, ≥93 dB sensitivity (1W/1m), ≥119 dB maximum SPL, and frequency response of 80 Hz – 16 kHz (±3 dB). Dispersion shall be symmetrical and min ≥90° × 60° WITH OEM SUPPLIED MOUNTING ACCESSORIES/BRACKETS and it should come with 5 years warranty with CE or FCC or UL certifications. |
| 354 | Supply, Installation, testing and commissioning of ceiling loudspeaker shall be 2-way coaxial design with minimum 6.5-inch low-frequency driver and coaxially mounted high-frequency tweeter, providing minimum 120-degree conical coverage. Speaker shall have continuous power handling of minimum 60 watts RMS with integrated 70V/100V line transformer featuring selectable power taps via rotary switch and low-impedance bypass option. Frequency response shall be minimum 90 Hz to 20 kHz. Unit shall include integrated metal backcan. CE Certification or more. Min Warranty : 5 years |
| 355 | SITC of 4-channel Class-D installation power amplifier, delivering minimum 4 × 300 W RMS at 4 Ω (≥150 W at 8 Ω, ≥2 × 600 W in bridged mode), with 20 Hz–20 kHz (±3 dB) frequency response, >95 dB signal-to-noise ratio, <0.05 % THD+N at 1 kHz, and >100 damping factor. Unit shall provide balanced Euro-block inputs, Euro-block loudspeaker outputs, configurable 100 V/70 V and low-impedance (4–8 Ω) operation, onboard or network-integrated DSP for parametric EQ, limiting, and crossovers, plus USB or Ethernet/IP control interface, in 19″ 1–2 HE rack-mountable steel construction. |
| 356 | Supply,installation,testing and commissioning of wireless microphone system shall comprise one (1) UHF true/switching diversity quad-channel receiver in EIA-standard 19-inch 1U rack-mountable metal chassis with detachable antennas, three (3) rechargeable handheld transmitter microphones with dynamic cardioid capsules, one (1) rechargeable bodypack transmitter compatible with lavalier/headset microphones, and requisite charging station(s). The receiver shall support minimum four simultaneous UHF channels with auto-scan frequency selection and transmitter-receiver synchronization. Frequency response shall be minimum 50Hz–18kHz. Signal-to-noise ratio shall exceed 85dB(A). Audio outputs shall include per-channel balanced XLR with switchable MIC/LINE level. Transmitters shall feature rechargeable lithium-ion batteries. System working range shall be minimum 100 metres line-of-sight. it should come with 5 years warranty with CE or FCC or UL certifications. BIS Mandatory |
| 357 | Supply,installation,testing and commissioning of wireless gooseneck microphone system shall comprise a UHF quad-channel true diversity receiver in EIA standard 19-inch 1U rackmount metal chassis with four independent receiving channels, individual balanced XLR audio outputs, switchable MIC/LINE level, and LCD/OLED display with RF and audio metering. Each gooseneck transmitter shall be uni-directional condenser type operating in UHF 500–960 MHz band with minimum 100 preset frequencies, auto-scan channel selection, infrared/Bluetooth synchronization, and minimum 8 hours battery operation. System working range shall be minimum 100 metres line-of-sight. it should come with 5 years warranty with CE or FCC or UL certifications. BIS Mandatory |
| 358 | Supply,installation,testing and commissioning of audio DSP system shall comprise open-architecture, networked digital signal processor(s) operating at minimum 48kHz sampling rate with 24-bit or higher A/D-D/A conversion and floating-point processing. The system shall provide a combined minimum of 16 electronically-balanced analog mic/line inputs with switchable +48VDC phantom power and 6 electronically-balanced analog line outputs. Minimum 64×64 bi-directional Dante™/AES67 networked audio channels over standard CatX cabling shall be supported. DSP functions shall include parametric/graphic EQ, matrix mixing, automatic mic mixing, compressor/limiter, noise gate, delay, AGC, and source selection. Multiple networked units within the same product family are acceptable. Standard 19\\" rack-mountable. it should come with 5 years warranty with CE or FCC or UL certifications. |
| 359 | Supply,installation,testing and commissioning of indoor LED video wall shall employ SMD (Surface Mounted Device) technology with a pixel pitch of ≤2.0 mm. Display area should be minimum (4.2 m (W) × 2.36 m (H)), approximately 190\\" diagonal in 16:9 aspect ratioThe system shall deliver brightness ≥600 nits, contrast ratio ≥5000:1, viewing angle ≥160°(H)×140°(V), and refresh rate ≥3000 Hz. LED lifetime shall be ≥100,000 hours with 24/7 operational capability. Cabinets/tiles shall support full front-serviceability with 16:9 aspect ratio. Power input shall be AC 100–240V, 50/60 Hz. The system shall be configured to achieve a minimum resolution of 1920×1080 (Full HD). The complete system shall carry a comprehensive onsite warranty of five (5) years from the date of installation and commissioning, covering all LED modules, power supplies, receiving cards, controllers, and accessories. it should come with 5 years warranty with CE or FCC or UL certifications. |
| 360 | SITC of 55\\" Professional Ultra HD Display Panel, 4K UHD (3840x2160) Resolution, Brightness 350 Nits, Contrast Ratio (Typ.): 4000:1, Viewing angle (horizontal & vertical): 178 / 178 degree, Operational Hour: 16x7,Stereo Mini Jack, Connectivity: Video Input:Min 2 HDMI 2.0, 2 USB 2.0, Control: RS232, Ethernet, 2x10W Built-in speakers, CA53 1.3GHz Quad-Core, 8 GB Inbuilt memory, CE, FCC, UL, BIS, ISO 45001 Certified etc all complete. Orientation - Landscape & Portrait with 5 years warranty |
| 361 | Supply and Installation of CUSTOM STAND WUTH TROLLER WITH 3-4 ADJUSTABLE ANGLES including wheels for rotating as per design and details approved by Engineer Incharge. |
| 362 | Supply, Installation, Testing & commissioning of 21.5-inch Full HD (1920×1080) IPS panels offering wide 178-degree viewing angles with 16.7 million color support. it should support both HDMI and VGA connectivity for versatile device compatibility, offers tilt adjustment for comfortable viewing, and features ultra-slim/borderless designs for modern aesthetics. All are Energy Star certified with mercury-free backlighting technology and include cable management solutions. |
| 363 | Supply, Installation, Testing & commissioning of PTZ camera shall be 4K UHD type with minimum 1/2.5-inch CMOS sensor delivering 3840×2160 resolution at minimum 30fps with minimum 30x zoom capability in 4K including clear image zoom and autofocus. Camera shall support AI-powered auto-tracking for autonomous presenter following via built-in processing or licensable software. Simultaneous video outputs shall include HDMI, 3G-SDI, and IP streaming with NDI|HX protocol support. Camera shall provide pan range ±170°, tilt range -30° to +90°, minimum 100 preset positions, PoE+ power, and IP-based web configuration. CE, FCC, RoHS certified (Warranty - 5 Years) |
| 364 | SITC of AV-over-IP encoder shall support 4K60 4:4:4 video encoding over standard 1Gbps Ethernet with low-latency codec. Encoder shall provide one USB-C input with minimum 60W power delivery and one HDMI 2.0 input supporting HDCP 2.2, with automatic or manual input switching and one HDMI loopout. Unit shall support HDR content, video scaling, fast switching, and minimum 8-channel PCM embedded audio with networked audio supporting AES67 or equivalent. Encoder shall include IP-based control, RS-232 serial port, PoE support, and multipoint-to-multipoint video matrix capability.CE, FCC, RoHS certified (5 YEARS WARRANTY) |
| 365 | SITC of 4K@60 Video over 1G Encoder, with HDMI 2.0 4K@60Hz 4:4:4 with HDCP 2.2 compatibility, 1x HDMI with USB2.0 host port, 1x HDMI loopout output, 12-bit color depth processing for better deep color image, HDR10, HDR10+, Dolby Vision, Video Scaling from any resolution to any resolution, Low latency ~1 frame in Ultra Low Latency Mode, support fast switching, built-in Video Wall / Mosaic Video Wall support with rotation and bezel compensation, Video 90/180/270 rotation, horizontal and vertical flip, Multipoint to multipoint video transmission for video over ethernet matrix, optional Dante AV-A Integration (Video Switching with Dante Controller), analog embedding to HDMI, analog de-embedding from HDMI, ARC / eARC support, Up to 8 channels LPCM HDMI or compressed audio up to Dolby Atmos and DTS-X, 8x8 LPCM Dante Audio Embedded with Dante Ready capability, controls over IP including Serial with Serial Generation Capability, and IR over IP with IR Generation Capability. CE, FCC, RoHS certified |
| 366 | SITC of AV-over-IP encoder shall support 4K60 4:4:4 video encoding over standard 1Gbps Ethernet using low-latency visually lossless codec with HDMI 2.0 input supporting HDCP 2.2 compliance and one HDMI loopout output. Encoder shall support embedded multi-channel HDMI audio with networked audio capability supporting AES67 or equivalent protocol. Unit shall provide USB 2.0 signal routing, RS-232 serial control over IP, and PoE power capability with IP-based management via web interface. Encoder shall support multipoint-to-multipoint IP video matrix switching and SRTP/AES encrypted stream transport. CE, FCC, RoHS certified. (5 YEARS WARRANTY) |
| 367 | SITC of professional-grade USB bridge device, designed to interface standard USB-enabled computing devices for conferencing camera and audio applications. The device shall support bidirectional USB transmission with plug-and-play functionality and shall be compliant with USB 2.0 or higher standards. The unit shall integrate seamlessly with encoder and decoder. The device shall include appropriate USB Type-B and USB Type-A port along with network connectivity (Gigabit Ethernet). The device shall be powered via PoE (Power over Ethernet) and shall include status indicators for power, network connectivity. The unit shall be suitable for rack-mount or under-table installation and shall comply with international standards such as CE, FCC, and RoHS and comes with 5 Years warranty |
| 368 | SITC of AV-over-IP system controller shall provide centralized management and configuration of all networked video encoders and decoders with automatic endpoint discovery. Controller shall offer IP-based management via web GUI, Telnet API, and RS-232 serial interface supporting third-party control system integration. System shall enable matrix-style video switching and routing between multiple encoders and decoders over standard 1Gbps managed Ethernet network with real-time endpoint status monitoring. Unit shall feature PoE power capability, dual Gigabit Ethernet ports, and power/status LED indicators. CE, FCC, RoHS certified. (5 YEARS WARRANTY) |
| 369 | SITC of switch with 1U rack-mount, fully managed Layer 2/Layer 3 Multi-Gigabit Ethernet switch with minimum 24× RJ45 ports supporting 1G to 10G speeds with IEEE 802.3bt PoE++ delivering minimum 60W per port and a total PoE budget of not less than 1,440W via dual hot-swappable redundant power supplies. It shall provide minimum 2× 10G SFP+ uplink ports, non-blocking switching capacity of minimum 640 Gbps, IGMP v1/v2/v3 Snooping with Querier, IEEE 1588 PTPv2, IEEE 802.1Q VLANs, MACsec encryption, 802.1X authentication, LACP link aggregation, STP/RSTP/MSTP, and stacking bandwidth of minimum 480 Gbps with hitless failover. Management shall include Web GUI, CLI, SNMP v3, REST API, and cloud management platform. Unit shall operate on 100–240V AC and comply with FCC Part 15A, CE, and UL/IEC safety standards. |
| 370 | SITC of 4K HDMI to USB video capture device shall accept HDMI 2.0 input supporting resolutions up to 4K@60Hz 4:4:4 with HDCP 2.2 compliance, HDR support, and 18Gbps video bandwidth. Device shall provide USB 3.0 capture output with built-in 4K@60Hz downscaling to 1080p@60Hz supporting uncompressed YUV2 via USB 3.0. Unit shall support embedded HDMI audio capture and be compatible with Windows and macOS operating systems. Device shall work with standard UVC video conferencing applications including Zoom, Teams, OBS, and VLC. USB bus-powered, compact plug-and-play design. CE, FCC, RoHS certified. with 5 Years warranty support. |
| 371 | SITC 4K60 multi-window processor shall provide minimum four HDMI 2.0 inputs with HDCP 2.2 compliance, 18Gbps video bandwidth, and 4K@60Hz HDMI output on single UHD display. Processor shall support multiple windowing modes including single full-screen, picture-in-picture, side-by-side, and quad-view with seamless switching and fully customizable window arrangements. Unit shall support multi-channel audio passthrough with analog stereo audio de-embedding for external distribution systems. Controls shall include front panel buttons, RS-232, Ethernet/IP-based management, and configuration software with EDID management. Compact metal enclosure, 5-year warranty. CE, FCC, RoHS certified (Warranty - 5 Years) |
| 372 | Supply, installation, testing and commissioning of Wireless Presentation & Video Conferencing System with dedicated USB-C Wireless Sharing Pod/Button or equivalent native wireless sharing capability. Base unit shall support 4K video output via HDMI with one HDMI input for wired content. System shall support wireless screen sharing from iOS, Android, Windows, macOS and ChromeOS using native AirPlay, Google Cast and Miracast protocols without proprietary software installation. Minimum two simultaneous screen sharing on single display with built-in moderation/presenter control mode shall be supported. System shall support BYOM wireless video conferencing compatible with MS Teams, Zoom, Google Meet and Webex, enabling wireless bridging of room USB peripherals including camera, microphone and speakers to presenter’s laptop. Built-in on-screen annotation and digital whiteboard or equivalent collaboration tools shall be provided. System shall have built-in dual-band Wi-Fi (IEEE 802.11ac or higher) with standalone access point mode, Ethernet RJ-45 LAN with DHCP, enterprise-grade encryption (WPA2 or higher), and centralized cloud-based device management with OTA firmware update capability. USB-C Sharing Pod, where provided, shall enable single-cable plug-and-play BYOD and BYOM operation without driver installation, supporting Windows and macOS. FCC/CE/BIS or equivalent certified. 5-year OEM onsite warranty. |
| 373 | SITC for complete cables as per detail given below and as per available site and solution required as per approval of engineer in charge. # Audio/Speaker/Microphone Cable: SITC of 4 Sqmm Audio cable with PVC or LSZH Insulation, Min. 300V operating voltage, Low resistance copper core. # In Cat 6a its, UTP Cable, Performance: 10GBASE-T, 1000BASE-T, 100BASE-TX, 10BASE-T, 155Mbps ATM, Operating Frequency: Up to 500 MHZ, Conductor: 23 AWG Solid Bare Copper. Shielding: Foil shield around all 4 pairs, Operating Temperature: -40 to 70 degree C'. # Original Nuetrik Connectors. |
| 374 | SITC of 36U standard 19\\" floor‑standing server‑type rack enclosures, constructed from mild steel/CRCA with powder‑coated finish, 600–800 mm width and 600–1000 mm depth, suitable for Audio, Video & networking. Units shall feature 4‑column rack rails, adjustable or fixed depth channels, removable side panels, front glass/ventilated locking doors, cable‑entry provision, and integral grounding, with static load capacity not less than 100–500 kg depending on model |
| 375 | VEV/VRF System |
| 376 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperaturewithout tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . |
| 377 | SITC of following electronic components for communication and control of ODUs and AHU as per OEM of VRF/VRV system : |
| 378 | Corded remote control for ductable indoor unit |
| 379 | AHU kit |
| 380 | Communication kit |
| 381 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 382 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 383 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 384 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 385 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 386 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 387 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 388 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 389 | Thickness 0.63 mm sheet |
| 390 | Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 391 | Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 392 | Supplying, Fixing, installation, testing and commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 393 | 200 mm dia. |
| 394 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [For Fabricating frame ODUs of split AC -.Design/Shape will be decided by Engineer-in-charge] |
| 395 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 396 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 397 | Earthing |
| 398 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 399 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 400 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 401 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 402 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. ( Dismantling of feeder pillar / panel foundation) |
| 403 | Providing and laying in position cement concrete 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for the repair of the road after cutting of road for cable repair and laying. |
| 404 | Fire Fighting System |
| 405 | Providing and fixing CO 2 High Pressure Portable 4.5 kg Fire Extinguisher, filled with CO 2 Gas as per IS 15222, Gross Weight 16.4, empty weight 11.9 Kg, Control discharge mechanism fitted with 1 Meter Wire Braided Hose & Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 55B, Internal coating is not applicable & Externalcoating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED,Extinguishers confirmed to IS 15683:2018 and ISImarked. |
| 406 | Providing and Fixing ABC Type Fire Extinguisher Cap. 4 kg Filled with Mono Ammonium Phosphate Powder 90% confirms to IS 4308, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 6.7 Kg, Empty Weight 2.7 Kg, Can Height 490mm, Diameter 140 ± 10mm, Discharge Time 18 Sec, Controllable discharge mechanism, Jet Range 3 Meters, Average Discharge is 92%, applicable on ClassA,B & C and electrically started Fire, Fire Rating4A:144B, Can Construction : Deep drawn & MIGwelded, EPDM Rubber Hose with both endAluminum crimped, Internal & External - PurePolyester Powder coating (UV Resistant), Brassforged valves with safety Pin is of SS material,Made up from 1.6mm thick sheet, ISI Approved IS15683:2018. |
| 407 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 408 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 409 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs etallic over complete with all connections etc. as required. |
| 410 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 411 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 412 | 4 Zone |
| 413 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. Each 10033.00 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set. |
| 414 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 415 | Emergency light series |
| 416 | PEL LED INFINITE SERIES LIGHT - Automatically Switches-ON mains power failure and ed duration, after which the batteryprovides illumination on battery source for speci gets automatically cut-off, to facilitate quick recharge on resumption of main supply. Once the battery is totally charged it automatically slides into trickle charge to constantly retain the charge and be ready for immediate use. Non Maintained. CONFORMS TO : IS - 10322, ingress protection : IP 20, 600 mm, Housing : Aluminium Extruded Flame Retardant, paint & Colour : Epoxy polyester powder coating, White in colour, Diffuser : Opal, Supply voltage : 230VAC, Supply current : 50mA max, LED Make : Edison. Wattage : 10W, Luminous flux : >190LM, Ambient temperature : 25°C-60°C, 180 Minute Battery Backup, Type : Non-Maintained, Automatic switching : Relay, Ra : > 40, Make PROLITE ACCULITE, ALKLITE AUTOGLO |
| 417 | Supply of BIS Certified Self Contained Rechargeable Surface Mounted Emergency Egress Routes Lighting , Maintained Type , ingress protection IP 20 , Housing CRCA Sheet 22 SWG fabricated, Message printed on 2mm thick milky acrylic, Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Viewing distance 24M, Ambient temperature -25°C to +60°C, , INDICATIONS Mains ON: Red LED ON, CIRCUIT POWER - Overall: 5W - On mains (LED): 3W - On battery (LED): 3W, PROTECTION - Protection class: Class I, Low battery cut-off: 2.4±0.1V ,Over charge cut-off: 4.2±0.1V , BATTERY - Charging method: Constant Voltage - Back-up duration: 120 minutes - Recharging period: 10-18 hours - Battery type: 3.7V lithium ion - Battery capacity: 2200mAH, Conforms to IS 10322, BIS Certified Part 5 / Sec - 8 .Make PROLITE ACCULITE, ALKLITE AUTOGLO |
| 418 | Supply of BIS Certified Self Contained Rechargeable Surface mount Single sided, maintained 3 watt led, fire exit luminaries with left , right, straight directions and exit ,made with multiple LED. Made up of Cold Rolled Close Annealed Sheet 22 SWG fabricated, Message printed on 8mm clear polycarbonate diffuser. With Supply voltage 230VAC, Supply current 50mA max, Ambient temperature - 25°C to +60°C, , INDICATIONS Mains ON: Red LED ON, CIRCUIT POWER. Protection class: Class I, Low battery cut-off, Over charge cut-off short circuit and reverse polarity protection, BATTERY - Charging method: Constant Voltage - Back-up duration: 120 minutes - Recharging period: 10- 18 hours - Battery type: SMF compact rechargeable batteries, (Impact Test) IK 05 protection, with surge protection and high insulation resistance.BIS Certified as per IS 10322 Part 5 Section 8 : 2013 and IP 65 ingress protection. Make PROLITE ACCULITE, ALKLITE AUTOGLO |
| 419 | Supply of Self Maintain Photo luminescent Siganages for hotels, hospitals, buildings in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive ,Weather Proof .Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe , Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part 2 / 60 Minutes / > 700 mcdl with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified for All require QC test to Confirm As per the IS 9457-2005 ,IS 12349 (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White approved by Local Director of Fire and Emergency services..and BIS approved. make PROLITE / ALKLITE / ACCULITE / AUTOGLO Evacuation Plan Size A3 (297X420) |
| 420 | SITC of linear LED step lights suitable for step edge mounting tting which continuously remains ON, on 12V DC power supply through a S. M. P. S.,and provides illumination on step's inner edge made in extruded aluminum housing alloy provided with anti skid narrow ribbedhigh density rubber extrusion with Epoxy polyester powder coating (Black in colour),diffuser made in well grooved acrylic rod to provide eye soothing uniform low glow to not to disturb the audience during the show in the darkness complete with SMPS etc as required |
| 421 | Dismantling |
| 422 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 423 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 424 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 425 | Dismantling of SPN Industrial type socket outlet alongwith MCB, in sheet steel enclosure including credit for same etc. as required. |
| 426 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. |
| 427 | Up to 25 mm conduit. |
| 428 | Above 25 mm conduit. |
| 429 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 430 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 431 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 432 | less credit for the unserviciable items dismantled items during execution of the work. |
| 433 | Assorted PIANO/modular Type Switches |
| 434 | Assorted PIANO/modular Type Sockets |
| 435 | Assorted Bell push/PIANO/modular Type |
| 436 | Assorted Call bell buzzer single phase |
| 437 | Assorted Brass batten/ angle holder/Brass Bracket |
| 438 | Assorted Fan regulator/resistance type |
| 439 | Assorted Telephone Socket outlet |
| 440 | Assorted T.V. Socket outlet |
| 441 | Assorted Capacitor, 3.15/2.50/2.25 mfd |
| 442 | Assorted 1200/1400 mm sweep ceiling Fan with blades |
| 443 | less credit for the dismantled Copper wire wires from light points/ circuit/ submain/power circuit wiring,. |
| 444 | less credit for the dismantled aluminium wire wires from light points/ circuit/ submain/power circuit wiring,. |
| 445 | Assorted metal switch box. |
| 446 | Assorted MCB DB SPN with out MCBs |
| 447 | Assorted MCB DB TPN with out MCBs |
| 448 | Assorted MCB SP |
| 449 | Assorted MCB DP |
| 450 | Assorted MCB TP AND TP&N |
| 451 | Assorted Industrial type sockets |
| 452 | Air-conditioners 1.5 / 2.0 Ton Split / window type any make complete with Outdoor and indoor unit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender