Tender For Repair / Replacement Of Old Unsv Rusted Pipe Line,Pump/Motor.Cleaning Of Over Head Tank And Connected Works Of External Water Supply ; Repairs/Maint Of Internal Electricification ; Repairs & Maintenance Of Security/Perimeter Lights/Garden
Tender Overview
Project Description
Tender for Repair / Replacement Of Old Unsv Rusted Pipe Line,Pump/Motor.Cleaning Of Over Head Tank And Connected Works Of External Water Supply ; Repairs/Maint Of Internal Electricification ; Repairs & Maintenance Of Security/Perimeter Lights/Garden Lights/Gate Lights & Connected Items;Repair /Maint/Servicing To Cooling Appliances ; Repairs/Maint Lt Panels & Earthing At Nlp Mil Stn Under Ge 872 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. |
| 2 | S&F MCCB 4 pole 50 A, 415 V, 16 KA, adjustable thermal (80%-100%) , (Ics=100% of Icu) in replacement of unsv MCCB of any capacity and specification . Make and Model as per site requirement to fix in existing Panel complete all as per specified and as directed. |
| 3 | S&F MCCB 4 pole 63 A, 415 V, 16 KA, adjustable thermal (80%-100%) , (Ics=100% of Icu) in replacement of unsv MCCB of any capacity and specification . Make and Model as per site requirement to fix in existing Panel complete all as per specified and as directed. |
| 4 | S&F MCCB 4 pole 100 A, 415 V, 16 KA, adjustable thermal (80%-100%) , (Ics=100% of Icu) in replacement of unsv MCCB of any capacity and specification . Make and Model as per site requirement to fix in existing Panel. Make- Havells/ Schneider/ABB/ L&T . |
| 5 | S&F on load Change Over Switch (Front Operated) Open Execution, 100 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 6 | S&F on load Change Over Switch (Front Operated) Open Execution, 125 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 7 | S&F on load Change Over Switch (side handle operated) in sheet metal enclouser, 32 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 8 | S&F on load Change Over Switch (side handle operated) in sheet metal enclouser, 63 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. |
| 9 | M&L Repairs/Maint & Servicing of DG Set 30 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works(a) Replacement of all Filters, Lubricating Oil.(b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings.(c) Carry out necessary Tappet Clearance, if required.(d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins.(e) Check functioning of Changing Alternator.(f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required.(g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required.(h) The Governor shall be Checked and Tuned for Proper Functioning.(j) Check for Leaks if any and shall be rectified.(k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues.NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items. |
| 10 | Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 11 | Supply only AVR (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 12 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 13 | Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 14 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 15 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 16 | Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 17 | Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 18 | Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 19 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed. |
| 20 | M&L Repairs/Maint & Servicing of DG Set 62.5 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed comprising with the following Works (a) Replacement of all Filters, Lubricating Oil.(b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings.(c) Carry out necessary Tappet Clearance, if required.(d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins.(e) Check functioning of Changing Alternator.(f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required.(g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required.(h) The Governor shall be Checked and Tuned for Proper Functioning.(j) Check for Leaks if any and shall be rectified.(k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues.NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items. |
| 21 | Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 22 | Supply only AVR (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 23 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 24 | Supply only Controler Model No. KG934/GC 1202 (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 25 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 26 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 27 | Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 28 | Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 29 | Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 30 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed. |
| 31 | Dismantling the alternator of 30 KVA to 62.5 KVA DG Set from its position after disconnection of electric connection with the help of claim pully,-removing the bearing with the help of bearing pullar and shifting the alternator to authorised workshop for repair and servicing complete checking of connections ,terminals, lugs tightning of connections replacement of bushes complete and refixing again its own position and proper alingment complete all as specified and directed |
| 32 | M&L for rewinding of alternator coils on of any capacity using proper size, double paper covering wuth super enammenalled copper guage winding wires conforming to IS 7404 (Part-1): 1991 as per existing size, turns and insulation class including connecting minor insulation materials , gasket suitable for 415 V alternator complete all as specified and as directed. |
| 33 | M&L for synthetic rubber insulation mat IS 15652-2006 suitable for 1100 volts of size 2m x 1m x 2.5 mm ISI marked complete all as per specified and as directed. |
| 34 | Disconnecting and dismounting the self starter 12 Volts from the engine and transporting to workshop for further repair/replacement of unservicable parts/servicing, transporting back the self from workshop and re fixing with DG set, testing complete all as specified and directed by the Engineer-in-Charge. (For DG set capacity of 30 kv and,62.5 KVA |
| 35 | M&L Battery 12 V of Capacity 120 AH ,complete all including taking down/out unserviceable battery all as specified and as directed. |
| 36 | S&F Oil safety control in any type and capacity of DG set as per site requirement including taking down complete all as per specified and as directed. |
| 37 | S&F Solenoid switch assembly in any type and capacity of DG set as per site requirement including taking down. |
| 38 | S&F water safety control in any type and capacity of DG set as per site requirement including taking down complete all as per specified and as directed. |
| 39 | S&F water temperature gauge in any type and capacity of DG set as per site requirement including taking down complete all as per specified and as directed. |
| 40 | S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out unserviceable Toggle Switch, complete all as specified and as directed. |
| 41 | Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. |
| 42 | Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. |
| 43 | M&L Cleaning of Radiator of any capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed. |
| 44 | M&L Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed. |
| 45 | Disconnecting all electrical cable connections from the dynamo assembly and taking down the dynamo assembly for carrying out repairs and complete overhauling the system including replacing the unserviceable parts like Carbon brushes, Bearings, Armature. Burnt out coils etc. reassembling and re-fixing the dynamo assembly to its original position and reconnect all disconnected cable connections including testing complete all as per specified and as directed. |
| 46 | Supply and charging of gas F-12 including welding brazing to stop leakage vaccum test pressure test for 40/80 ltrs water coolers including servicing complete all as specified and directed. |
| 47 | Supply and charging of gas F-22 including welding brazing to stop leakage vaccum test pressure test for deep freezer of capacity 320 ltr including servicing complete all as specified and directed. |
| 48 | S & f Fan blade assembly heavy duty(water cooler) complete as per original specifications suitable for including taking down existing complete all as specified and directed. |
| 49 | S & f Fan motor 1/35 ( or) 1/32 HP capacity suitable for Water Cooler of cap 40/80 & 60/120 ltrs of including taking down existing complete all as specified and directed. |
| 50 | S & f Starting kit comprising of relay and overload protector for water cooler 40/80 ltrs capacity including taking down existing complete all as specified and directed. |
| 51 | S & f Thermostatic switch including taking down existing complete all as specified and directed. |
| 52 | S & fix PVC drain pipe one meter long 32mm dia heavy duty with two nos of galvanized adjustable clamps including taking down existing complete all as specified and directed. |
| 53 | S & fix Starting capacitor 40/60 mfd suitable for water cooler 40/80 ltrs capacity including taking down existing complete all as specified and directed. |
| 54 | S & fix Hermetically sealed compressor unit single phase for 40/80 ltr water cooler including taking down existing complete all as specified and directed. |
| 55 | S & fix Denting / welding and painting with two coats of synthetic enameled paint by spray painting after preparation priming of surfaces of water cooler of capacity 40/80 ltr including writing MES Nos all as specified and directed. |
| 56 | S & fix Capacitor 10 mfd capacity for water cooler 40/80 or 60/120 ltr capacity including taking down existing complete all as specified and directed. |
| 57 | S & fix PVC insulated and sheathed copper conductor 3 core 40/.0076 ( Colour white or black) including taking down existing complete all as specified and directed. |
| 58 | S & fix PVC float valve suitable 15 mm dia assembly and comprising valve assembly alum rod, PVC ball for water cooler/ desert coolers including taking down existing complete all as specified and directed. |
| 59 | S & fix Push cock chromium plated brass of 15mm dia size including taking down existing complete all as specified and directed . |
| 60 | S & fix Overload protector 2613 including taking down existing complete all as specified and directed . |
| 61 | Opening of Refrigerators freeze of capacity 285/310 ltrs refixing the same after flushing out and removal of blockage brazing, replacement of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling ( Temperature) complete including testing all as specified and directed . |
| 62 | S & fix Over load protector 1/6 HP for refrigerators including taking down existing complete all as specified and directed. |
| 63 | S & fix Pigmy lamp 15 watt AC 230 volts including taking down existing complete all as specified and directed . |
| 64 | S & fix Freeze assembly complete as per original make and suitable for 286/310 ltr cap refrigerator all as specified and directed |
| 65 | S & fix Door gasket magnetic type for 286/310 ltr capacity refrigerator including taking down existing complete all as specified and directed |
| 66 | S & fix Relay open type 1/6 HP including taking down existing complete all as specified and directed. |
| 67 | S & fix Chilled freezer tray plastic complete suitable for refrigerator 286 to 310 ltr capacity including taking down existing complete all as specified and directed. |
| 68 | S & fix Vegetable tray plastic complete suitable for refrigerator 286 to 310 ltr capacity including taking down existing complete all as specified and directed . |
| 69 | S & fix Power circuit Breaker for refrigarator of capacity 286/310 ltr complete all as specified and directed . |
| 70 | S & fix PVC ice tray superior quality of large size with PVC separator complete for refrigerator for any capacity & make all as specified and directed. |
| 71 | S & fix Hermetically sealed compressor for 286/310 ltr refrigerators Model 043 including taking down existing complete all as specified and directed . |
| 72 | Supply and charging of gas F-22 to Window/split type Air conditioner 1.5/2 Ton capacity including servicing of any make model including brazing to stop the leakage of required pressure testing complete all as specified and directed |
| 73 | S & fix Heavy duty condensor fan blade assembly for fan motor of appropriate size ( as per sample) suitable for 1.5 Ton/ 2 ton capacity window/split type AC including taking down existing complete all as specified and directed . |
| 74 | S & fix Indoor motor , single phase ,230 volt matching to the same model and capacity for 1.5 Ton / 2 Ton capacity window/split type AC complete all as specified and directed.. |
| 75 | S & fix Outdoor motor , single phase ,230 volt matching to the same model and capacity for 1.5 Ton / 2 Ton capacity window/split type AC complete all as specified and directed.. |
| 76 | S & fix Insulation on and around suction and discharge copper piping with 6mm thick flexible thermocol heat resistant duly scrapped with sticking tape including taking down existing complete all as specified and directed . Note :- Units install at different floor of Command Hospital. |
| 77 | Shifting of split type AC outer unit 2 ton/1.5 ton with accessories including gas charging , welding brazing to stop leakage vacum test pressure, testing , insisting thick flexible thermocol and servicin of indoor and outdoor unit complete all as specified and directed. |
| 78 | Supply and fixing in replacement of Compressor including charging of gas rotary type suitable for Split/Window ACs 1.5 Ton incl gas charging including taking down existing complete all as per specified and as directed. |
| 79 | Dismantling voltage stablizer including transformer copper wound , relays contact point, wiring with replacement of volt meter repair to transformer ,replacement of relays , assembling the complete and testing for capacity 3 KVA and input rating 135-290 Volts complete all as specified and directed . |
| 80 | S & fix Copper tube 5/8\\" and 3/8 \\" including taking down existing complete all as specified and directed . |
| 81 | S & fix Copper tube 1/2\\" including taking down existing complete all as specified and directed . |
| 82 | S & fix Brass flare nut copper pipe 1/2\\" / 3/8\\" including taking down existing complete all as specified and directed . |
| 83 | Repair to power circuit (PC plate) for split/Window AC 1.5 ton capacity complete all as specified and directed . |
| 84 | Repair to power circuit (PC plate) for split AC 2 ton capacity complete all as specified and directed . |
| 85 | S & fix Sensor set dry cool complete allas specified and directed |
| 86 | S & fix Power circuit PVC plate for split/Window AC 1.5 ton capacity complete all as specified and directed . |
| 87 | S & fix Power circuit PVC plate for split AC 2 ton capacity complete all as specified and directed . |
| 88 | M and labour and taking down Sub main wiring FRLS PVC insulated flexible standed copper conductor 1100v, 2 run of 6 Sqmm main cable main cable with one run of 4.00 Sqmm single core FRLS PVC insulated stranded copper conductor as earthing in concealed conduitcomplete all as specified and directed . |
| 89 | S&F in repair of single pole and neutral encloser with two pin earth plug and socket 230Volts AC flush type,with provision of 20 Amps single pole MCB including necessary connection complete all as per specified and as directed. |
| 90 | M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed.NOTE :-(a) Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department.(b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as \\"S&F\\"/\\"M&L\\" under relevant Items. |
| 91 | S&F Ball Bearing (size as per existing One/ as approved) suitable for Ceiling Fan 1200/1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed. |
| 92 | S&F Condenser 2.0/2.5 mfd suitable for Ceiling Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed. |
| 93 | S&F Fan Blade Aluminium suitable for Ceiling Fan 1200mm Sweep of any Make/Model, Aero dynamically balanced and screwed with suitable size Mild Steel Screws including Taking down/out unserviceable Fan Blade, complete all as specified and as directed. |
| 94 | M&L Frame suitable for Exhaust Fan 380/400mm Sweep with Mild Steel Flat and fixing with Bolts, Nuts, Washers, etc. as required/ordered including Taking down/out unserviceable Frame, complete all as specified and as directed. |
| 95 | S&F Gun Metal Bush (size as per existing One/ as approved) suitable for Ceiling/Exhaust/Cabin Fan of any Make/Model and any Size including Taking down/out unserviceable Bush, complete all as specified and as directed. |
| 96 | M&L Louver Shutter suitable for Exhaust Fan 380mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls including Taking down/out unserviceable Louver Shutter, complete all as specified and as directed. |
| 97 | M&L Louver Shutter suitable for Exhaust Fan 400mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls including Taking down/out unserviceable Louver Shutter, complete all as specified and as directed. |
| 98 | M&L Mild Steel Down Rod 15mm nominal dia and 18\\" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed. |
| 99 | M&L Mild Steel Down Rod 15mm nominal dia and 24\\" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed. |
| 100 | M&L Mild Steel Down Rod 15mm nominal dia and 36\\" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed. |
| 101 | M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 102 | M&L Transporting Exhaust Fan 300/ 380mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 103 | M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 104 | M&L Transporting Pedestal Fan of any Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 105 | M&L Taking down Ceiling Fan of any Sweep from any Situation after disconnecting, Preparing old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, Re-hanging the Fan in Original Postion & Re-connecting and Testing, complete all as specified and as directed. |
| 106 | S&F Ceiling Fan Regulator Dimmar Switch type, 230 Volt AC, Rotary Stepped, Electronic type 120/280 Volt and connecting up including Taking down/out unserviceable Fan Regulator, complete all as specified and as directed. |
| 107 | M&L Taking/Lowering down unserviceable Electric Water Heater (Geyser) 25 Litre capacity, Storage type from any Situation after disconnecting all Water Supply & Electric Connections and carry out following Checks :-(a) Inspection of Geyser and Opening, Dismantling, Brushing and Cleaning of Storage Water Tank, Removing all Sludge, Scalling and Bleaching from the Tank and Examining of any leakage of Water, Tightening of Nuts, Bolts and Re-installation the same in Original Position complete.(b) Check and Connecting Earth Continuity to Electric Water Heater.(c) Checking and Adjusting of Pressure Release Valve.(d) Check and Maint of Thermostate Valve.(e) Visual Examination of Fusible Plug. |
| 108 | M&L Taking down Electric Water Heater 25 Litre capcity of any Make/ Model by carefuly Un-bolting, Dismantling the Electric Water Heater, Taking out the Aparatus Assembly, Inner Tank, Glass wool, Thermostats, Checking the Point of any leakages on Inner Tank, Brazing for Removing of Leakage, Re-assembling the Electric Water Heater and Re-fixing of Appratus Assembly including Replacing of Glass wool, Re-installation Electric Water Heater in Original Position, Providing all Electrical & Water Supply Connections and Testing, complete all as specified and as directed. |
| 109 | S&F Base Assembly Gasket of any shape and size, suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly Gasket, complete all as specified and as directed. |
| 110 | S&F Base Assembly (Inner), Brass Chromium plated complete of any shape and size with Inlet, Outlet, Thermostate Slot, drain plug, Clamp or Bolts to fixing Heating Element as existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly (Inner), complete all as specified and as directed. |
| 111 | S&F Brass Chromium plated Connection with Brass Chromium plated Adaptor 350mm long, making connection to in Inlet & Outlet suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/out unserviceable Connection with Adaptor, complete all as specified and as directed. |
| 112 | S&F Fusible Plug in existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model and Testing including Taking down/out unserviceable Fusible Plug, complete all as specified and as directed. |
| 113 | S&F Glass Wool (Insulation Materials) superior quality (as approved) suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking out unserviceable Glass Wool, complete all as specified and as directed. |
| 114 | S&F Heating Element 1.5 KW 230 Volt AC suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed. |
| 115 | S&F Heating Element 2.0 KW 230 Volt AC suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed. |
| 116 | S&F Indication Lamp Assembly consisting Red & Green in Colour of any shape and size, 230 Volt suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed. |
| 117 | S&F Inner Shell (Inner Tank), ISI marked, made out of Copper Sheet 22 Gauge thick suitable for Electric Water Heater 25 Litre capacity of any Make/Model in existing Shape & Size including Taking down/out unserviceable Inner Shell, complete all as specified and as directed. |
| 118 | S&F Inner Shell (Inner Tank), ISI marked, made out of Stainless Steel Sheet 20 Gauge thick suitable for Electric Water Heater 25 Litre capacity of any Make/ Model in existing Shape & Size including Taking down/out unserviceable Inner Shell, complete all as specified and as directed. |
| 119 | S&F Outer Body complete with Top & Bottom Cover, Inspection Plate suitable for Electric Water Heater 25 Litre capacity of any Make/Model and applying Two Coats of Synthetic Enamelled Paint (as approved) ove a coat of Red Oxide Zinc Chrome Primer with Spray Painting Machine including Taking down/out unserviceable Outer Body, complete all as specified and as directed. |
| 120 | S&F PVC Connection in Inlet, 15mm bore (dia) & 450mm in length with PTMT Nuts suitable for Cold/Hot Water including Taking down/out unserviceable PVC Connection, complete all as specified and as directed. |
| 121 | S&F Safety Valve, ISI marked suitable for Electric Water Heater 25 Litre capacity of any Make/ Model including Taking down/out unserviceable Safety Valve, complete all as specified and as directed. |
| 122 | S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 240 Volt AC suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/out unserviceable Thermostate Switch, complete all as specified and as directed. |
| 123 | S&F PVC insulated, Flexible, Copper multi-stranded Cable, Cross-sectional area 4.0 Sqmm, 3 Core and making Electric connection to Electric Water Heater and Plug Top including Taking down/out unserviceable Cable of any description, complete all as specified and as directed. |
| 124 | S&F Metal Clad Top 2 Pole & Earth 20 Amp, ISI marked and connecting up including Taking down/out unserviceable Metal Clad Top, complete all as specified and as directed. |
| 125 | S&F Plug Top 6 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed. |
| 126 | S&F Plug Top 16 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed. |
| 127 | M&L Taking down Street/Perimeter/Flood Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.NOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'. |
| 128 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30/35 Watt, complete all as specified and as directed. |
| 129 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 45 Watt, complete all as specified and as directed. |
| 130 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 60 Watt, complete all as specified and as directed. |
| 131 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 100 Watt, complete all as specified and as directed. |
| 132 | S&F LED Street Light Fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed. |
| 133 | All as per item No 6 here-in-before but 60 watt LED street light, 230V AC outdoor type with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed |
| 134 | &F LED Street Light Fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed |
| 135 | S&F RUBY (CLEAR) 25 Watt LED , New Generation, Post Top Lantern, New Generation, Energy Saving, Environmental Friendly, Long Life, Aesthetically Designed with Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire with High Power LEDs as Light Source, IP-65 protected, suitable for Pole 76mm dia, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed. |
| 136 | S&F MOON (OPAL) 20 Watt LED Lamp Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit LED Bulb with B-22 Base, having Mounting Pole Dia - 60mm (Max) OD, Width: 160mm & Height : 284mm, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed |
| 137 | S&F PVC insulated Aluminium Wire 1.5 Sqmm, 3 Core for Providing Connection from Street Light Fitting to Overhead Line and Junction Box including Taking down Unserviceable Wire of any description, complete all as specified and as directed. |
| 138 | M&L Preparing Surfaces of LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. applying One Coat of Aluminium Paint to Pole, One Coat of Synthetic Enamel Painting to Pole in Strips 250mm high (5 No.) with Two different Colours from Top of PCC Copping, Writing Pole Number with Black Paints, Height of letters not less than 65mm including applying One Coat of Aluminum Paint to Cross Arms, Channel, Flat Iron Clamps, etc. complete all as specified and as directed. |
| 139 | Supply, Installation & Commissioning LT Panel Board, Factory Made (CPRI Tested Manufacturer), made out of 3.15mm thick CRCA Sheet with Angle Iron Frame 50x50x6mm, Outdoor type, Double Doors, Front & Rear Opening with Locking Arrangement, Platform mounted, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz Supply having 4 No. Copper Bus-bars 200 Amp rated, installed on Porcelain/ Epoxy Insulator, Dust Proof and Vermin Proof (IP-54), Feeder Pillar Box Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer and Fixing with Mild Steel Bolts, Nuts, Washers, etc. on Cement Concrete 1:2:4 (20mm graded Stone aggregate) Platform (minimum 150mm Space around the Panel Board and 600mm Height above & 450mm below from Natural Ground Level) and grouting Mild Steel Angle Iron Legs in Floor, Providing all Electric Connections and Testing, Comprising with and including following Accessories including Taking down/ out Unserviceable Panel Board, complete all as specified and as directed :-INCOMING :-(a) MCCB 100 Amp, 4 Pole, 16 kA, 415 Volt - 01 No.(b) Digital Ammeter 0-630 Amp with Selector Switch - 01 No.(c) Digital Volt Meter 0-500 Volt with Selector Switch - 01 No.(d) Indicating Lamp LED type in Incomming Phase - 01 Set(e) CT's Operated including CT's 0-400 Amp, 96x96mm Flush Mounted - 01 Set with Selector SwitchOUTGOING :-(f) MCCB 63 Amp, 4 Pole, Fixed type, 16 kA, 415 - 02 No.(g) MCCB 50 Amp, 4 Pole, Fixed type, 16 kA, 415 - 01 No.NOTE :-(a) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt IS-694 marked of appropriate gauge including Aluminium Lugs.(b) MCCB shall be provided with suitable Spreader of Aluminium Conductor for fixing of Incoming Cable.(c) All MCCB will be fixed on Bakellite Sheet 8.0mm thick and shall be connected with Solid Aluminium Conductor from Bus-bar. |
| 140 | S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 280x170x100mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed.MAKE : SINTEX |
| 141 | S & F in repair Street light bracket fabricated out of 32mm bore GI tubing, light grade, 1.5m long with one side arm type and along with 02 sets of suitable size of flat iron clamps and nuts, bolts & washers to fix the bracket on steel tubular pole and including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 142 | Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 143 | M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 144 | All as per item No.143 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 145 | All as per item No. 143 above but for One 3/5 pin socket outlet 6 amps ons same board complete ditto |
| 146 | All as per item No. 143 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto |
| 147 | S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up, including Taking down/out unserviceable one complete all as specified and as directed.complete all as specified and as directed. |
| 148 | S&F Switch Socket Combination 6 Amp, Flush type, Universal, including PVC box of suitable size, 230 Volt AC and connecting up, including Taking down/out unserviceable one complete all as specified and as directed.complete all as specified and as directed. |
| 149 | S&F Socket Outlet 2-in-1, 3 Pin, 6 Amp, Flush type, 230 Volt AC and connecting up including Taking down/out unserviceable Socket Outlet, complete all as specified and as directed. |
| 150 | S & F Switch Socket Combinatio 16 Amp, Flush type, Universal, including PVC box of suitable size, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 151 | S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminals suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed. |
| 152 | S&F Lamp Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up, complete all as specified and as directed. |
| 153 | S&F 10 W Decorative LED Bulk Head Fitting made out of Polycarbonate and connecting up complete all as specified and as directed. |
| 154 | Supply only LED Batten 20 Watt 4 Feet long, Decorative ultra Slim Square profile fixture with extruded polycarbonate, Cool Day Light fitting ready to use pack complete all as specified and as directed. (Make Havells, Surya Roshni, Syska or Crompton) |
| 155 | Supply only in replacement of LED bulb 9 watts, 230 volt complete all as specified and directed. |
| 156 | Supply only in replacement of LED bulb 15 watts, 230 volt complete all as specified and directed. |
| 157 | Supply only LED luminaire 600 mm x 600 mm (2 x 2 ft), 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete including taking out/down unserviceable one. |
| 158 | S&F round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking out/down unserviceable one. |
| 159 | S&F LED light fitting mirror type with high out put diffuser 2 feet Mirror, 10 watt 220 V AC decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 160 | M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed including taking down unserviceable wiring.NOTE :-(a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be included in the Quoted Unit Rate and the same also be Mesured as ONE UNIT.(b) Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate. |
| 161 | M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed including taking down unserviceable wiring.NOTE :-(a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be included in the Quoted Unit Rate and the same also be Mesured as ONE UNIT.(b) Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate. |
| 162 | S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed. |
| 163 | S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed |
| 164 | S&F PVC Rectangular Block of size 100x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed. |
| 165 | S&F PVC Rectangular Block of size 175x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed. |
| 166 | S&F PVC Rectangular Block of size 200x150x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed. |
| 167 | S&F MCB Single Pole 6 to 32 Amp, 'B' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 168 | S&F MCB Single Pole 40 Amp, 'B' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 169 | S&F MCB Single Pole & Neutral 32 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 170 | S&F MCB Single Pole & Neutral 40 to 63 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed. |
| 171 | S&F Distribution Board Sheet Metal Enclosure, Factory made fixed Flush with Wall inside the Nitches or Outside on Wall surface suitable for mounting Isolators & MCB's 240 Volts suitable rated Bus-bar capacity SPN 2-way, Single Door Front Openable and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed. |
| 172 | S&F Distribution Board Sheet Metal Enclosure, Factory made fixed Flush with Wall inside the Nitches or Outside on Wall surface suitable for mounting Isolators & MCB's 240 Volts suitable rated Bus-bar capacity SPN 4-way, Single Door Front Openable and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed. |
| 173 | S&F Distribution Board Sheet Metal Enclosure, Factory made fixed Flush with Wall inside the Nitches or Outside on Wall surface suitable for mounting Isolators & MCB's 240 Volts suitable rated Bus-bar capacity SPN 8-way, Double Door Front Openable and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed. |
| 174 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 175 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 176 | Taking up Cast Iron Water Mains 100mm bore (dia), Spigot and Socket Ends with all Fittings by burning out Lead Joints and recovering Lead, complete all as specified and as directed. |
| 177 | Taking up Cast Iron Water Mains 80mm bore (dia), Spigot and Socket Ends with all Fittings by burning out Lead Joints and recovering Lead, complete all as specified and as directed. |
| 178 | Taking up Cast Iron Water Mains 50mm bore (dia), Spigot and Socket Ends with all Fittings by burning out Lead Joints and recovering Lead, complete all as specified and as directed. |
| 179 | Supply, laying or lowering Steel Water Tubing 100mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or lowering down or any other situation, complete as all specified and as directed. |
| 180 | Supply, laying or jointing & lowering Steel Water Tubing 80mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or lowering down under borewell or any other situation, complete as all specified and as directed. |
| 181 | Supply & laying Steel Water Tubing 50mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed. |
| 182 | Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 25mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, including taking down/out unserviceable pipe complete all as specified and as directed. |
| 183 | All as per srl No. 182 above but 32mm bore (dia) complete ditto all as per specified and as directed. |
| 184 | All as per srl No. 182 above but 50mm bore (dia) complete ditto all as per specified and as directed. |
| 185 | All as per srl No. 182 above but 63mm bore (dia) complete ditto all as per specified and as directed. |
| 186 | S&F PP-R (Polypropylene Random Copolymer) Gate Valve 25mm bore (dia), Brass insert with Wheel Head, screwed both Ends including Taking down/ out Unserviceable Gate Valve of any description, complete all as specified and as directed. |
| 187 | All as per srl No. 186 above but 32mm bore (dia) complete ditto all as per specified and as directed. |
| 188 | All as per srl No. 186 above but 50mm bore (dia) complete ditto all as per specified and as directed. |
| 189 | All as per srl No. 186 above but 63mm bore (dia) complete ditto all as per specified and as directed. |
| 190 | Supply and fixing Butterfly valve class PN 1.6 of 65 mm dia bore (ISI marked) conformig to IS - 13095 (wafer type) including all jointing materials such as MS nuts, bolts, washer's gasket, etc and testing including taking out old unserviceable sluice valve complete all as specified and as directed. |
| 191 | Supply and fixing sluice valve class PN 1.6 of 80 mm dia bore (ISI marked) conformig to IS - 13095 (wafer type) including all jointing materials such as MS nuts, bolts, washer's gasket, etc and testing including taking out old unserviceable sluice valve complete all as specified and as directed. |
| 192 | All as per srl No. 191above but 100 mm dia bore (ISI marked) complete ditto all as per specified and as directed. |
| 193 | All as per srl No. 191 above but 150 mm dia bore (ISI marked) complete ditto all as per specified and as directed. |
| 194 | M&L for construction of brick masonery valve pit of size 60cmx60cmx60cm (internal dimension) one brick thick wall in built in CM (1:4) on 100mm thick PCC type D2(1:4:8) (using 40mm graded stone aggregate) as in foundation, and rendering 15mm thick plaster in cement mortar (1:4) both externally & internally,external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate,including provision of hinges, handle and locking arrangement with 40x40x5mm angle iron frame fixed on top of valve pit by means of hold fast 40 x 40 x 5 mm angle iron frame fixed on top of valve pit by means of MS old fast 40 x 5 mm and 150 mm long, embedded in PCC (1:2:4) type B1 & (using 20mm graded stone aggregate) block of size 230 X 200 X 100mm, including two coats of synthetic enamel paint over a coat of red oxide zinc and handle and locking arrangement including taking down of existing unservicable valve and necessary earth work in soft/loose soil complete all as specified and as directed |
| 195 | M&L for construction of brick masonery valve pit of size 100cmx100cmx100cm (internal dimension) one brick thick wall in built in CM (1:4) on 100mm thick PCC type D2(1:4:8) (using 40mm graded stone aggregate) as in foundation, and rendering 15mm thick plaster in cement mortar (1:4) both externally & internally,external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate,including provision of hinges, handle and locking arrangement with 40x40x5mm angle iron frame fixed on top of valve pit by means of hold fast 40 x 40 x 5 mm angle iron frame fixed on top of valve pit by means of MS old fast 40 x 5 mm and 150 mm long, embedded in PCC (1:2:4) type B1 & (using 20mm graded stone aggregate) block of size 230 X 200 X 100mm, including two coats of synthetic enamel paint over a coat of red oxide zinc and handle and locking arrangement including taking down of existing U/S valve and necessary earth work in soft/loose soil complete all as specified and as directed |
| 196 | Material and labour for cleaning of existing water sump of 46800 ltr capacity by carrying out the following works all as specified and directed. (a) Dewatering the sump by employing \\" Tulu pump and man power\\"(b) Removing the sludge, Muddy and dissolved iron water from the sump by employing man power and required tool.(c) Scrubbing the algae from walls, corners etc completely by using wire brush and Man power. (d) Scrubbing the algae from walls, corners etc completely by using wire brush and Man power.Note : M&L such as bamboos, munj or other equipment are required for structure of outside tank shall arranged by the contractor from his own sources for which cost of the same shall be included in the unit rate. No extra amount shall be paid separately on this account. |
| 197 | All as per srl No. 196 but for the existing capacity of 60000 ltr capacity all as per specified and as directed. |
| 198 | M&L for Rewinding of monoblock pump of capacity 3 HP including Taking out/ down Unserviceable winding, complete all as specified and as directed. |
| 199 | Supply only Ball Bearing suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed. |
| 200 | Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed. |
| 201 | M&L for Rewinding of monoblock pump of capacity 5 HP including Taking out/ down Unserviceable winding, complete all as specified and as directed. |
| 202 | Supply only Ball Bearing suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed. |
| 203 | Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed. |
| 204 | Repairs to 10 HP Monoblock pump involving the following operations :-(a) Opening of the detective in MES Yard/Workshop cleaning the covers and parts as applicable in presence of a Board of Officers to be nominated by GE to ascertain the quantum of defects and repairs involved.(b) Transporting the defective motor/pump to contractor's workshop for repairs as directed by the Board of Officers and carrying out the needful repairs including replacement of defective unserviceable parts.(c) Assembling the motor after repair(d) Painting the repaired motor externally with two coats of synthetic enamel paint of shade as directed by Engineer-in-Charge.e) Transporting the repaired motor to MES Yard/Workshop and carrying out necessary tests in presence of Engineer-in-Charge to establish functionability of the repaired motor upto the entire satisfaction of Engineer-in-Charge.Note : -(i) Parts required to be replaced shall be measured and paid separately as \\"Supply only\\" against relevant items of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item including arrangement of chain pully to taking out motor from borewell etc.(ii) Any minor repairs involved to make the motor completely functional, even if not notified by the Board of Officers, shall be carried out by the contractor without any extra cost to the department.(iii) Rewinding of stator of motor, where invloved shall be measured and paid separately against relevant item of this schedule.(iv) Greasing/Oiling etc of parts as as required shall be done by the contractor without any extra cost the the Department. |
| 205 | Repairs to 12.5 HP Submercible Motor & Pump involving the following operations :-(a) Opening of the detective in MES Yard/Workshop cleaning the covers and parts as applicable in presence of a Board of Officers to be nominated by GE to ascertain the quantum of defects and repairs involved.(b) Transporting the defective motor/pump to contractor's workshop for repairs as directed by the Board of Officers and carrying out the needful repairs including replacement of defective unserviceable parts.(c) Assembling the motor after repair(d) Painting the repaired motor externally with two coats of synthetic enamel paint of shade as directed by Engineer-in-Charge.e) Transporting the repaired motor to MES Yard/Workshop and carrying out necessary tests in presence of Engineer-in-Charge to establish functionability of the repaired motor upto the entire satisfaction of Engineer-in-Charge.Note : -(i) Parts required to be replaced shall be measured and paid separately as \\"Supply only\\" against relevant items of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item including arrangement of chain pully to taking out motor from borewell etc.(ii) Any minor repairs involved to make the motor completely functional, even if not notified by the Board of Officers, shall be carried out by the contractor without any extra cost to the department.(iii) Rewinding of stator of motor, where invloved shall be measured and paid separately against relevant item of this schedule.(iv) Greasing/Oiling etc of parts as as required shall be done by the contractor without any extra cost the the Department. |
| 206 | Supply only Ball Bearing suitable for Monoblock Pump 10.0 HP capacity, complete all as specified and as directed. |
| 207 | Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed. |
| 208 | M&L for Rewinding of monoblock pump of capacity 10 HP including Taking out/ down Unserviceable winding, complete all as specified and as directed. |
| 209 | M&L for rewinding 12.5 HP sumbersible pump,motor complete all specified and directed and supply to following items suitable for pump,motorNote : -(i) Parts required to be replaced shall be measured and paid separately as \\"Supply only\\" against relevant items of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item.(ii) Any minor repairs involved to make the motor completely functional, even if not notified by the Board of Officers, shall be carried out by the contractor without any extra cost to the department.(iii) Rate includes Rewinding of stator of motor, where invloved.(iv) Greasing/Oiling etc of parts as as required shall be done by the contractor without any extra cost the the Department. |
| 210 | Taking out unserviceable in repair to direct online Starter for 3 HP from panel board and S&F in existing panel board new direct online Starter for 3 HP motor , including making all electric connection and fixing arrangement complete all specified and directed. |
| 211 | Taking out unserviceable in repair to direct online Starter for 5 HP from panel board and S&F in existing panel board new direct online Starter for 5 HP motor , including making all electric connection and fixing arrangement complete all specified and directed. |
| 212 | Taking out unserviceable in repair to direct online Starter for 10 HP from panel board and S&F in existing panel board new direct online Starter for 10 HP motr\or , including making all electric connection and fixing arrangement complete all specified and directed. |
| 213 | Taking out unserviceable in repair to Star Delta Starter for 12.5 HP from panel board and S&F in existing panel board new Deluxe Automatic Star Delta Starter for 12.5 HP motor , including making all electric connection and fixing arrangement complete all specified and directed. |
| 214 | Supply only Calcium Hypo Chlorite (altock GP/aquafit) 65%-70% Chlorine content (Calcium based Granuar Disinfectant for water treatment (as approved by GE) for chlorination of water i.e. 2PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed.NOTE : Original Purchase Voucher shall be furnished by the Contractor for payment. |
| 215 | Supply only Bleaching Powder for Water Treatment (as approved by GE) for Chlorination of water i.e. 2PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed.NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for payment. |
| 216 | Supply only Alum for Water Treatment (as approved by GE) for Chlorination of water i.e. 2PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed.NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for payment. |
| 217 | Taking out (unloading) the old catalyst from Iron Removal Plant oxidation chamber with proper care complete and cleaning of pipes, Butterfly valve etc, of any capacity,flow, height by opening the manhole cover disconnection and including removing the waste material up to 50 mtr away from site spreading and leveling complete all as specified and directed by Engr-in-charge. |
| 218 | Taking out (unloading) the old filter media (Sand & Gravels) from Rapid Sand Filteration plant of any capacity and including removing the waste material up to 50 mtr away from site spreading and leveling complete all as specified and directed by Engr-in-charge. |
| 219 | Supply & Filling in layers New Life Manganese Dioxide (MnO₂) Compound (as approved) to Remove Iron and Manganese from Drinking Water by Process of Oxida-tion and suitable for Use in Filteration Plant and Oxidation Chamber (as per require-ments), complete all as specified and as complete all as specified and as directed.NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher will be furnished by the Contractor for Payment. |
| 220 | Supply & Filling in layers New Washed, Cleaned, Dust Free Filter Media (Sand & Gravels) of sizes 3/4\\"x1/2\\", 1/2\\"x1/4\\", 1/4\\"x1/8\\", 1/8\\" x1/6\\" (as approved) suitable for Use in Filteration Plant (Rapid Sand Filter and IRON Removal Plant as per requirements), complete all as specified and as directed. |
| 221 | Supply and fixing new PVC double nut type strainers as per site requirement ,complete in all respect, all as specified and directed by Eng-in-charge including taking down/up unserviceable strainer. |
| 222 | Supply and fix new Pressure gauge with fittings as per site requirement with isolating valve and siphon including Taking down unsv pressure gauge with fittings of any size and type andall as specified and directed by Engr-in-charge. |
| 223 | S&F Injection Check Valve (3/8\\")for Chemical Dozing Pump make : RMCO; model : CHEMIJJECT RC 11 Complete all as specified and as directed including taking out unserviceable spares. |
| 224 | Supply only Chlorine Test Kit with coloured ample complete with all testing fitments and OT solution in rexene finish box |
| 225 | Supply only OT Solution for chlorine test (500 ML) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender