Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #57300270

Tender For special Repair To Bldg No P-30 (Rp Dump Store) Of Certain Mil Unit And special Repair Of Bathroom Near Trg Node (Np-01), Bathroom Near Trg Cell (P-50) And Bathroom Near Mt Store (P-47) Of Certain Mil Unit Under Ge (S) Binnaguri

Issued by Statutory Bodies & Commissions/Committees · Jalpaiguri, West Bengal
Tender Value
29.76 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
0 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Bldg No P-30 (Rp Dump Store) Of Certain Mil Unit And special Repair Of Bathroom Near Trg Node (Np-01), Bathroom Near Trg Cell (P-50) And Bathroom Near Mt Store (P-47) Of Certain Mil Unit Under Ge (S) Binnaguri

BOQ

Name of Work:- SPL REPAIR TO BLDG NO P-30 (RP DUMP STORE) OF CERTAIN MIL UNIT AND SPL REPAIR OF BATHROOM NEAR TRG NODE (NP-01), BATHROOM NEAR TRG CELL (P-50) AND BATHROOM NEAR MT STORE (P-47) OF CERTAIN MIL UNIT UNDER GE (S) BINNAGURI
Sl. No. Item Description
1Material and labour for providing and laying first-quality, fine machine-cut, mirror-polishable Kota stone slab flooring of nominal thickness 20 mm to 25 mm, of approved shade, size, texture, and colour (selected greenish-blue, grey, or brown), conforming to IS 1130 and IS 1443, in floors, landings, corridors, passages, and treads of steps at all heights, elevations, and floor levels, executed in a comprehensive flooring and finishing sequence comprising: thoroughly cleaning, chipping, hacking, washing, and pre-wetting the base concrete / RCC substrate, applying a neat cement slurry bonding coat; laying a 15 mm thick (average thickness) bedding screed bed in cement mortar 1:6 (1 part ordinary Portland cement : 6 parts graded coarse sand / fine aggregate); setting, tapping with wooden mallets, and bedding the pre-wetted Kota stone slabs true to line, level, and specified drainage slope using neat grey cement slurry applied over the screed bed at the rate of not less than 4.40 kg of cement per square metre of floor area, admixed with approved light-fast mineral colour pigment to match the stone shade; jointing with uniform fine hairline/paper joints, filling and pointing joints flush with matching pigment-admixed cement slurry or polymer-modified grout; precision machine edge cutting, straight cutting, and notch cutting around columns, pipes, and corners; continuous water curing for a minimum period of not less than 7 days; followed by systematic multi-stage mechanical machine grinding, rubbing, and polishing using water and carborundum abrasive stones of progressive grit sizes (rough cut with Grit No. 60, intermediate with Grit Nos. 120 and 240, and fine finish with Grit No. 320), washing clean, grouting fine pinholes with matching cement slurry, light grinding, and final mirror-buffing with oxalic acid and tin oxide / approved floor wax to obtain an ultra-smooth, high-gloss, even, non-slippery, scratch-free, and stain-free surface; including washing down, cleaning all slurry splashes and stains from adjacent walls, skirtings, doors, and frames, complete all as specified.(Note:Rates include the 15 mm average thick CM 1:6 screed bed, cement slurry bedding @ 4.40 kg/sq.m with matching pigment, machine cutting, joint pointing, multi-stage machine grinding, rubbing, oxalic acid mirror polishing, and curing. Base RCC floor slabs, sub-grade PCC foundation beds, and vertical Kota stone skirtings, dados, and step risers shall be measured and paid for separately under relevant items of Schedule 'A' unless specified otherwise.
2---Ditto-- all as above item No 1.00 in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick (average thickness) in cement motar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified
3M&L for coloured Non skid joint free ceramic tiles (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified
4M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18Sqm but n. exc. 0.38 Sqm, vertical surfaces, in skirting etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor complete including 15mm rendering on fair faces of brickwork or concrete with CM 1:4 all as specified
5M&L for cutting out cracks to 'V' section (shape) in existing roof slab terracing cleaning out and filling solidely with cement and sand mortar (1:1) complete all as specified
6M & L for Cutting out concrete blocks, slabs, brickwork or stone masonry (in alter nate course), forming tooth-ings for and bonding new work in mortar into old work, including new materials entering old wall in CM 1:4 complete all as specified
7Supply only 100% virgin polyester triangular micro-fibres of approved make and brand, engineered specifically as secondary reinforcement for all types of plain and reinforced cement concrete (PCC/RCC), precast elements, floor toppings, guniting/shotcrete, and cement mortars/plaster systems, conforming to ASTM C1116 (Type III: Synthetic Fibre-Reinforced Concrete) and IRC:SP:46, having a unique triangular cross-section for superior mechanical anchoring, cut length of 6 mm (for plaster/mortar) or 12 mm / 18 mm (for concrete), filament diameter/effective thickness of 20 to 40 microns, specific gravity not less than 1.34 to 1.39, melting point not less than 240°C to 260°C, and tensile strength not less than 400 to 600 MPa, supplied in factory-sealed moisture-proof pre-measured pouches / poly-bags (such as 125 g pouches or bulk packs), delivered to departmental store / site of work, ready for direct dispersion during dry or wet mechanical batch mixing to arrest plastic shrinkage/micro-cracking and improve flexural toughness, impact resistance, and water impermeability, complete all as specified.(Note: Makes of Triangular Polyester Fibres: Reliance Industries Ltd. [Recron 3s - 6 mm / 12 mm] / Sika [SikaFiber / Crackstop] / Fosroc [Cebex / Structuro] / STP Ltd. [ShaliFiber 3s] / Master Builders Solutions / Saint-Gobain Weber or approved equivalent as in the list of Makes).
8M&L for 5mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified
9Material and labour for preparing internal or external surfaces of cement plaster, concrete, brickwork, or ceiling soffits and applying 2 mm nominal thickness of white cement-based polymer-modified wall care putty in two uniform layers (each coat approximately 1 mm thick), at all heights, elevations, and floor levels, executed in a systematic finishing sequence comprising: thoroughly preparing the substrate by scraping off loose mortar droppings, efflorescence, dirt, dust, and grease using wire brushes, steel scrapers, and sandpaper; washing down and pre-wetting the plastered/concrete substrate with clean potable water to achieve a saturated surface dry (SSD) condition; mixing factory-packed white cement-based polymer putty with clean water using a mechanical stirrer to obtain a lump-free, homogenous, workable paste; applying the first layer (nominal 1 mm thickness) evenly over the surface using a steel trowel / putty blade from bottom to top, filling all surface undulations, pinholes, and hair cracks, allowing it to set and dry for a minimum of 4 to 6 hours; gently rubbing down the dried first coat with fine waterproof emery paper (grit size 180/220) to eliminate blade marks; applying the second finishing layer (nominal 1 mm thickness) in a perpendicular / cross direction to achieve a cumulative minimum thickness of 2 mm; allowing full drying for 24 hours, followed by final rubbing and buffing with extra-fine waterproof emery paper (grit size 320/400) to obtain an ultra-smooth, uniform, even, plumb, non-powdery, and crack-free white surface ready to receive primer and paint; including providing and erecting necessary staging, scaffolding, ladders, drop sheets, masking, and thoroughly cleaning all putty droppings and dust from adjacent floors, joinery, glass panes, and electrical fittings, complete all as specified.(Note: White cement-based wall care putty shall conform to IS 17435 / IS 15477 and manufacturer technical specifications, and white cement base to IS 8042. Rates include all substrate scraping, washing, pre-wetting, mixing, two coats of putty application [each 1 mm thick], double emery sanding, scaffolding at all heights, and cleanup. Base cement plaster rendering, structural crack repair mortar, and subsequent primer / distemper / emulsion paint finishes shall be measured and paid for separately under relevant items of Schedule 'A' unless specified otherwise. Makes of White Cement Based Wall Putty: Birla White [Wall Care Putty] / JK Cement [JK WallMaxX] / Asian Paints [TruCare Wall Putty] / Berger Paints [Bison Wall Putty] / Nerolac [Wall Putty] / Sika / Fosroc or approved equivalent as in the list of Makes).
10Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Area not exceeding 2.00 sqm)
11Supply and fix 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50sqm in each pane complete all as specified.
12Supply and fixed galvanized mild steel wire cloth 0.56mm fixed nominal dia of wire and avrg widh of aperature 1.18mm and fixed with tinned tacks or galvanised wire staple complete all as spd.
13Supply and fixing as in repair for steel rolling shutters comprising of 1.25 mm thick mild steel laths, gear operated type with bevel gear box and cranked handle , as specified including top cover, anchoring rod, hasp and staple including applying one shop coat of red oxide zinc chrome primer, hoisted and fixed in proper position complete all as specified.
14S&F angle iron, MS flat iron in wind ties and similar work confirming to Fe 410-0 or Fe 310-0.complete all as specified
15Material and labour 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified
16Demolition of Concrete in ground floors and pavings n exc 15 cm thickness any description complete all as specified
17M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified
18Material and labour for providing and laying 60 mm nominal thickness factory-made, hydraulic-press / high-frequency vibratory compacted, rubber-moulded precast cement concrete interlocking paver blocks of Grade M-30 (minimum 28-day characteristic compressive strength of 30 N/mm²), of approved shape, pattern, and size (regular / zig-zag / uni-decor / rectangular / I-shape / hexagonal / dumbbell), conforming to IS 15658:2006 and IRC:SP:63, with grey Portland cement and approved UV-resistant synthetic mineral pigment for uniform colour/shade throughout the top wear layer (or through the full body), over footpaths, walkways, driveways, light-traffic roads, parking bays, and open courtyards at all heights, elevations, and floor levels, executed in a comprehensive paving sequence comprising: preparing, dressing, grading, and compacting the existing sub-base / water-bound macadam (WBM) / wet mix macadam (WMM) / concrete base to the required line, camber, and longitudinal drainage slope; providing, spreading, and leveling a 50 mm thick (uniform consolidated thickness) bedding cushion of clean, well-graded, non-plastic sharp sand (Zone II / Zone III coarse sand conforming to IS 383) screened through a 4.75 mm IS sieve; laying interlocking paver blocks dry by hand tight-jointed in specified herringbone, stretcher, or interlocking bond patterns true to alignment and grade; precision mechanical cutting/splitting of blocks at borders, manholes, curves, and edge restraints to fit neatly; compacting the laid paver block surface with a heavy-duty mechanical vibratory plate compactor (having a neoprene/rubber protective pad attached to the base plate) to bed the blocks uniformly into the sand cushion; sweeping and brushing dry, clean, fine jointing sand (passing through 2.36 mm sieve and conforming to IS 15658 / IS 383) over the entire paved area; running subsequent passes of the vibratory plate compactor to fill and pack all vertical interlocking joints completely; repeating joint sanding and brushing until all joints are solidly filled flush; removing surplus sand, and leaving the finished pavement surface even, level, stable, and ready for traffic, complete all as specified.(Note: Rates include the 50 mm thick compacted sand cushion, machine block cutting at edges, fine jointing sand, vibrating plate compaction, and cleaning up. Makes of Interlocking Paver Blocks: UltraTech [UltraTech Xtralite] / Godrej Construction / Basant Betons / Vyara Tiles / B&B Precast / Nitco / Jindal Precast or approved equivalent as in the list of Makes).
19M & L for PCC 1:2:4 type B-1 ,(using 20 mm graded stone aggregate) as. in coping /benching to sides of foot path fininished fair and even including necessary formwork etc complete all as specified
20Dismantling floor hearth or wall tiling including cement mortar bedding (incl backing) removing serviceable tiles to store and rubbish off the premises complete all as specified
21M&L for non-skid ceramic (400x400x7 to 8 mm thick) tiles set and jointed in neat cement slurry pointed in white or coloured cement to match in floor over 15mm thick screed bed in CM(1:6) all as specified
22M&L for glazed coloured ceramic tiles (350x450x7mm thick) on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match over 15mm thick rendering in CM(1:4) all as specified
23Taking down cement plaster any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc all as specified
24M&L for 5mm thick in CM 1:3 in ceiling finishing the surfaces even and smooth without using extra cement complete all as specified
25M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair complete all as specified
26M&L for rendering 20mm thick in cement mortar 1:4 in two layers of 10mm each using WPC on top 10mm layer on brick or concrete surfaces finished even & fair complete all as specified Note'(WPC for finishing layer will be paid seperately as supply only)
27Supply only Liquid water proofing compound.
28M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete etc all as specified
29M&L for complete removal of existing treatment of old plastered surfaces of ceiling and applying three coats of white wash all as specified
30M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified
31Material and labour for complete removal of existing unserviceable treatment / coatings on old plastered wall surfaces and applying two coats of oil-bound washable distemper (OBD) of approved brand, shade, and manufacture over one coat of water-thinnable interior wall primer, on internal walls, columns, and vertical surfaces at all heights, elevations, and floor levels, executed in a systematic surface preparation and finishing sequence comprising: thoroughly removing and scraping off all existing old coats of oil-bound distemper, white wash, colour wash, peeling/blistered paint, loose plaster scales, efflorescence, moss, dirt, dust, and grease using wire brushes, steel scrapers, sandpaper, and washing down with clean potable water to expose the sound base plaster substrate without gouging or damaging the plaster face; allowing the wall surfaces to dry completely; raking out, opening, and filling all minor surface depressions, pinholes, hairline shrinkage cracks, and indentations using approved plaster of Paris / interior polymer-modified wall putty to a true, even plane and rubbing down smooth with fine-grade sandpaper (grit size 180/220); applying one priming coat of approved alkali-resistant, water-thinnable white interior cement/wall primer conforming to IS 109, allowing sufficient drying time; light sandpapering after primer; and applying two finishing coats of washable oil-bound distemper conforming to IS 428, thinned with clean potable water in strict accordance with manufacturer instructions, applied evenly by brushing or rolling to achieve a smooth, uniform, streak-free, opaque, non-chalking, and washable matt finish, maintaining specified drying intervals between coats; including providing and erecting necessary scaffolding, staging, ladders, protective drop sheets, masking tapes, and thoroughly cleaning all distemper splashes, drips, and primer stains from door/window joinery, glazing, floors, skirtings, and electrical fixtures, complete all as specified.(Note: Oil-bound washable distemper shall conform to IS 428 [Specification for Distemper, Oil-Bound, Washable], interior wall primer to IS 109, and surface preparation/painting application to IS 2395 [Parts 1 and 2: Code of Practice for Painting Concrete, Masonry and Plaster Surfaces]. Rates include complete scraping/removal of old wall coatings, washing down, minor surface crack/indentation filling, primer, two coats of distemper, staging/scaffolding at all heights, and cleaning up. Base structural plaster repairs/replastering, full skim-coat wall putty [if ordered], and specialized POP punning shall be measured and paid for separately under relevant items of Schedule 'A' unless specified otherwise. Makes of Oil-Bound Distemper & Interior Primers: Asian Paints [Tractor Acrylic Distemper / Decoprime] / Berger Paints [Bison Distemper / BP White Primer] / Nerolac [Beauty Acrylic Distemper / Nerolac Wall Primer] / Dulux [Promise Acrylic Distemper] / Shalimar Paints [Utsav / Superlac] or approved equivalent as in the list of Makes).
32M & L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior emolsion paint of required shade for new work two coats and including priming coat of exterior primer etc all as specified
33Material and labour for complete removal of existing unserviceable treatment / coatings on old plastered external surfaces and finishing with 100% acrylic smooth weather-proof exterior emulsion paint of approved brand, shade, and manufacture, applying two finishing coats over one priming coat of exterior water-thinnable wall primer, on external walls, columns, parapets, chajjas, and cantilevers at all heights, elevations, and floor levels, executed in a systematic surface preparation and finishing sequence comprising: thoroughly removing and scraping off all existing old coats of unserviceable exterior paint, peeling emulsion, snowcem/cement paint, colour wash, loose plaster flakes, moss, algae, fungal growth, dirt, dust, and efflorescence using wire brushes, steel scrapers, sandpaper, and high-pressure water washing to expose the sound base plaster substrate without damaging the surface; treating bio-affected zones with approved anti-fungal / fungicidal wash solution where required and washing down with clean potable water; allowing the surfaces to dry completely; raking out, opening, and filling all minor surface defects, pinholes, hairline shrinkage cracks, and indentations using approved exterior acrylic polymer crack-filler / exterior wall putty to an even plane and rubbing down smooth; applying one priming coat of approved alkali-resistant, water-thinnable white exterior wall primer conforming to IS 109 / IS 5410, allowing sufficient drying time; and applying two finishing coats of smooth 100% acrylic exterior emulsion paint conforming to IS 15489, thinned with clean potable water in strict accordance with manufacturer instructions, applied evenly by brushing, rolling, or spraying to achieve an even, uniform, streak-free, anti-algal, anti-fungal, UV-resistant, and weather-proof smooth finish, maintaining specified drying intervals between coats; including providing and erecting necessary double/cantilever scaffolding, staging, cradles, ladders, protective drop sheets, masking tapes, and thoroughly cleaning all paint splashes and primer stains from door/window joinery, glazing, floors, downpipes, and electrical fittings, complete all as specified.
34(Note: Exterior acrylic emulsion paint shall conform to IS 15489 [Specification for Plastic Emulsion Paint for Exterior Use], exterior wall primer to IS 109 / IS 5410, and surface preparation and application to IS 2395 [Parts 1 and 2: Code of Practice for Painting Concrete, Masonry and Plaster Surfaces]. Rates include complete scraping/removal of old exterior coatings, wire brushing, water washing down, minor crack filling, primer, two coats of acrylic exterior emulsion, staging/scaffolding at all heights, and cleaning up. Major structural cement plaster repairs, polymer-modified structural crack grouting, and elastomeric waterproof coatings shall be measured and paid for separately under relevant items of Schedule 'A' unless specified otherwise. Makes of Acrylic Smooth Exterior Emulsion & Primers: Asian Paints [Apex / Apex Ultima] / Berger Paints [WeatherCoat Long Life / WeatherCoat Glow] / Nerolac [Excel Total / Excel Mica Marble] / Dulux [Weathershield Max] / Shalimar Paints [Weather Pro] or approved equivalent as in the list of Makes).
35Taking down tarfelt incl cement mortar bedding from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified
36Material and labour for providing, batching, machine mixing, laying, compacting, and finishing a 25 mm nominal thickness Plain Cement Concrete (PCC) screed bed of nominal mix 1:2:4 (Type B-0: 1 part ordinary Portland cement : 2 parts clean coarse sand / fine aggregate : 4 parts 12.5 mm nominal size graded crushed stone aggregate by volume), admixed with approved integral water proofing compound (liquid or powder conforming to IS 2645) @200ml/bag of cement, laid directly over existing/new RCC roof slabs, terraces, balconies, and chajjas at all heights, elevations, and floor levels, to serve as a sound leveling and protective base layer for subsequent roof waterproofing / thermal treatment, executed in a comprehensive concrete laying sequence comprising: thoroughly cleaning, hacking, chipping, sweeping, and washing the RCC roof slab surface to remove all dust, dirt, loose mortar droppings, and laitance; wetting the substrate to a saturated surface dry (SSD) condition; applying a neat cement slurry bonding coat (at the rate of not less than 2.75 kg of cement per square metre of slab area); machine mixing the 1:2:4 concrete with required proportion of water proofing compound (as directed by the Engineer-in-Charge and per manufacturer guidelines); laying and screeding the concrete true to specified lines, levels, thickness, and required drainage slopes/gradients (not flatter than 1 in 100 or as shown on drawings); tamping and thoroughly compacting mechanically or with heavy wooden tampers to eliminate voids; scoring and roughening the top surface of the freshly laid concrete transversely and longitudinally using stiff wire/coir/broom sticks while the concrete is still green to provide an effective mechanical key/grip for the subsequent waterproofing treatment layer; forming 75 mm × 75 mm coving / rounded fillets at all roof junctions with parapet walls and vertical upstands; providing necessary staging, hoisting, and scaffolding; continuous water curing by ponding or covering with wet gunny bags for a minimum period of not less than 10 days, and leaving the surface clean, structurally sound, and ready to receive roof treatment, complete all as specified.Note: Supplying and adding of integral water proofing compound [liquid/powder] shall be measured and paid for separately under relevant items of Schedule 'A' as specified
37Material and labour for providing and applying a comprehensive multi-layer waterproofing treatment system to RCC roof slabs, terraces, balconies, and chajjas at all heights, elevations, and floor levels, executed in a systematic and monolithic sequence strictly comprising the following stages:(a) Base Plaster & Bedding Screed: Providing and laying a 10 mm nominal thickness cement plaster / screed bed in cement mortar 1:4 (1 part ordinary Portland cement : 4 parts graded coarse sand / fine aggregate) admixed with approved integral water proofing compound (WPC conforming to IS 2645 at manufacturer recommended dosage), laid directly over the RCC roof slab while the slab concrete is green (or over a pre-wetted and neat cement slurry hacked surface) to true line, level, and specified drainage slopes/camber (not flatter than 1 in 100), finished smooth with a wooden float and steel trowel, including forming 75 mm × 75 mm rounded fillets / covings at all parapet wall junctions and vertical upstands, and wet curing for not less than 7 days;(b) Bituminous Priming Coat: Preparing and drying the plastered surface completely, cleaning off all dust, dirt, and loose particles, and applying a uniform coat of approved solvent-based bitumen primer conforming to IS 3384 at the rate of not less than 0.40 kg per square metre (0.40 litre/sq.m, having density at 25°C between 0.87 to 0.89 kg/litre and dynamic viscosity between 70 to 160 cps) evenly over the entire horizontal floor surface and vertically up parapet walls/upstands to a minimum height of 300 mm above finished roof level, allowing it to dry to a touch-dry condition;(c) Prefabricated APP Polymer-Modified Membrane:
38Providing and laying 3.0 mm nominal thickness (weighing not less than 3.50 kg per square metre) Atactic Polypropylene (APP) polymer-modified bitumen-based prefabricated 5-layer waterproofing membrane, reinforced with non-woven spun-bonded polyester reinforcement core/matt (minimum 160 g/m²), black finished with thin thermofusible polyethylene film on both sides, laid over the primed surface by torch-on application using liquefied petroleum gas (LPG) blow torches (or approved cold sticker application conforming to manufacturer technical specifications) to soften the bottom bitumen layer and bond it 100% homogeneously to the substrate, dressing the membrane vertically up the parapet walls to a minimum height of 300 mm and tucking/anchoring into a 65 mm × 65 mm groove cut in the parapet masonry sealed with cement mortar 1:3 admixed with WPC/elastomeric sealant, maintaining strict seam overlaps of not less than 150 mm on longitudinal (length) joints and not less than 100 mm on transverse (width / end) joints, with all overlaps sealed and smoothed using heated trowels/blades to achieve a seamless, blister-free, and watertight bond;(d) Protective Solar Reflective Coating: Applying two uniform coats of approved bitumastic aluminium paint / solar-reflective bituminous aluminium protective paint (conforming to IS 2339 / IS 158) over the exposed surface of the laid APP membrane (after conducting 48-hour continuous water ponding leakage tests to verify complete watertightness), maintaining required drying intervals between coats to provide UV radiation and thermal protection;including providing necessary double/cantilever scaffolding, staging, ladders, edge protection, LPG burner torches, gas cylinders, tools, and cleaning up all splashes, drips, and debris from adjoining walls, joinery, and glass panes, complete all as specified.
39(Note: Measurement shall be taken on the net exposed surface area treated [including vertical tucks/upstands up parapet walls] in square metres [Sq.m]. Cement plaster and screed materials shall conform to IS 269 / IS 1489, sand to IS 1542 / IS 383, integral waterproofing compound to IS 2645, bitumen primer to IS 3384, prefabricated APP modified bitumen membrane to IS 16405 / IS 16532 / ASTM D5147, bitumastic aluminium paint to IS 2339 / IS 158, and waterproofing code of practice to IS 3067 / IS 1609. Rates include the 10 mm CM 1:4 plaster with WPC, bitumen primer @ 0.40 kg/sq.m, 3 mm APP membrane [$\ge 3.5\text{ kg/m}^2$] with 150 mm/100 mm torch-welded overlaps, tucking into parapet grooves, two coats of bitumastic aluminium paint, 48-hour water ponding test, staging, and scaffolding at all heights. Base structural RCC roof slabs, parapet wall masonry, rain water pipes/khurras, and subsequent protective PCC/tile wear courses [if ordered] shall be measured and paid for separately under relevant items of Schedule 'A' unless specified otherwise. Makes of APP Modified Bitumen Membrane & Primers: STP Ltd. [Shaliplus / Super Shaliplus] / Sika [SikaBit PRO] / Fosroc [Proofex Torchseal / Conbextra] / Pidilite [Dr. Fixit Torchshield] / Tikidan [Danosa / Plastan] / IWL India / Asian Paints [SmartCare APP Membrane]; Makes of Bitumastic Aluminium Paint: STP Ltd. [ShaliAlu] / Asian Paints / Berger Paints / Shalimar Paints / Nerolac or approved equivalent as in the list of Makes).
40Taking down chowkats or frames exc 1.5 Sqm n exc 4 sqm (without taking off shutter from the frames) and removal from site complete all as specified
41Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar and removal of rubbish off the site of work as all as specified.
42M&L brickwork with fly ash birck straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks etc all as specified Note: Pulverized fuel ash-lime / cement fly ash building bricks shall conform to IS 12894 [Specification for Pulverized Fuel Ash-Lime Bricks / Fly Ash Bricks - Class Designation 7.5 / 10], fly ash raw material to IS 3812, brick masonry execution and workmanship to IS 2212
43M&L brickwork with fly ash birck straight or curved to plan any radius built in cement mortar 1:6 by bricks conforming to IS 12894 (machine-moulded and cured) and modular dimensions (90x90x90 mm or 230x110x70 mm size bricks etc all as specified
44S&F in repair Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing on SI page No 156 of SSR Part-II completed.
45S&F in repair Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing on SI page No.160 of SSR Part-II complete all as specified
46S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x60 mm complete all as specified
47S&F 30mm flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified
48Supply and fixed in repair steel window with side hung shutters with projecting type hinges, 3mm thick 100mm long copper oxidised finish mild steel handle and 3mm thick 300mm long mild steel copper oxidised finish peg stays and with glazing bars, dovetailed or welded with applying one shop coat of red oxide zinc chromate primer before fixing including taking down old unserviceable steel windows form existing position and making good disturbed surfaces of walls etc in all respect as per existing specification all complete as specified
49Ditto as per item No 45 but with out glazing bars all as specified
50S&F Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming toconforming to IS 2062 / IS 1977 Grade E-165 (Fe 290)
51S&F in repair factory made steel ventilator with top hung shutter including friction/ box type hinges ,steel peg stay complete including taking out old/unserviceable steel ventilator and making good to match as per existing surfaces etc complete all as specified
52M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or girth complete all as specified
53S&F 250mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section complete all as specified
54M&L for 150 mm size aluminium anodised cast type handles.
55S&F of 150mm long aluminium anodised,barrel tower bolt of extruded section.
56S&F 100mm size stainless steel butt hinges medium weight.
57S&F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty/ wooden beading in square exc 0.5 Sqm in each pane complete all as specified
58S & F of 4mm thick figured glass pin headed type n exc 0.5sqm each fixed to steel frame complete all as specified
59S&F in repair Water Closet (squatt pattern) of vitruous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cirstern and flush pipe) including connection to trap and flushing pipe anti syphon pipe etc complete including trap set in and incl concrete complete all as specified
60S&F in repair of PVC low level flushing cistern, 10 ltr capacity, syphonic action type white body with inlet ball valve, float , handle, bracket, long flush pipe of PVC to suit flushing cistern ( long bend) etc complete & connecting to WC complete all as specified
61S&F in repair of PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified
62S&F in repair Vitreous China wash basin Pedestal pattern, white, flat back size 580x450 mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipeincluding brackets, complete all as specified
63S&F in repair of pillars taps,fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, scewed for iron pipe 15 mm bore complete all as specified
64S & F in repair vitreous china half stall type urinal with grating and uninon for discharge pipe incl connecting pipe & waste pipe with coupling ,PVC connection 15 mm size with PTMT nuts of length required size complete all as specified
65S & F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified
66Dismantling of cement concrete of any size, position and any description complete all as specified
67Supply and fixing for TMT bars Grade Fe 500D conforming to IS 1786 , 10 mm dia, cut to length, bent to shape as required including cranking, bending and binding with mild steel wire (annealed)not less than 0.90 mm dia complete all as specified
68Supply & fix in repair angular stop cock made of brass chromium plated screwed both ends for iron pipe for 15mm bore complete all as specified.
69Supply & fix in reapir Bib tap cast copper alloy, chromium plated with crutch or butterfly handle, screwed down for 15mm bore GI Pipe or for brass ferrule including taking down old unserviceable one.
70S&F in repair tubular towel rail 20mm dia D type, Brass Chromium Plated 60 cm long between flanges.
71S & F stainless steel soap dish best quality fixed to plugs with chromium plated brass complete all as specified
72M&L in repairs for PVC floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(diameter of outlet 110mm) complete all as specified
73S&F in repair 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plug with chromium plated brass screws & cup washers complete all as specified
74M&L Gun-metal, globe or gate valves,15mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified
75S&F in repair for PVC (SWR) (Bore of pipe 110mm) pipes single socketed type A, in any length with rubber ring joints fixed to walls with necessary clamps, bolts etc complete all as specified.
76S&F in repair for PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters etc complete all as specified. (Bore of pipe 110mm)
77S&F in repair for PVC (SWR) vent cowl fixed to PVC Pipes etc complete all as specified. (Bore of pipe 110mm)
78S & F 500 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified
79S&F in repair 20 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut.
80M&L for 75mm thick PCC type C-2 (1:3:6) using 40 mm graded agg in plinth protection path/hardstanding finished cement concrete surfaces fair and even all as specified
81Taking up or down steel water tubings and fittings etc complete and making good disturbed surfaces of walls/ceilings etc complete all as specified of following bore:-
82(a) Bore tubing 15mm
83(b) Bore tubing 20mm
84M & L for steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete for this following.
85(a) Bore tubing 15mm
86(b) Bore tubing 20mm
87Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified
88M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws (or provision of modular sunken box, modular back plate and top cover for housing of modular switch,socket, regulators etc as per site requirement) for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified for the following :-
89(a) One light point controlled by one way switch 5/6 amps.
90(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
91(c) One socket out let 5/6 amps point on the same board
92(d) One socket out let 5/6 amps point on the independent board
93All as per item No 81 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified
94S&F switch piano flush type 5/6 amps single pole one way complete all as specified
95S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified
96S&F of socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified
97S&F switch piano flush type 15/16 amps single pole one way complete all as specified
98S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified
99S & F deluxe fan electronic regulator 230 volts AC 50 Hzs rotary step white/ivory finish complete all as specified
100S&F LED lights fitting 1x 20W, 220V AC decorative box type with driver,IP 20, class I, wall/ surface mounted, integrated type with extruded aluminium housing integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed connecting up with 2/3 core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories internally prewired and including necessary taking down the old unserviceable fitting complete all as specified.
101Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection luminaire efficiency not less than 100 lumens/watts integrated high efficiency electronic driver and surge suppressor of 7.5KV or more power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz and necessary mounting arrangements, provision of new 2/3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified.
102S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with din rail, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including provision of blanking plates as required and taking down the old one complete all as specified
103S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified
104S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘B’ curve, 10 KA all complete including taking down the old one complete all as specified
105M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified
106M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete including necessary taking down.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. .
107M&L for street light bracket made out of GI pipe light grade 32 MM dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling hole, fixing with runts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer.
108Taking down ceiling fan sealing cable end, dismantling blades and removing fan and blades to store complete all as specified
109M & L for painting of ceiling fans of any make/model and size complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.complete all as specified
110Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified
111S&F LED lights fitting 1x 10W, 220V AC decorative box type with driver,IP 20, class I, wall/ surface mounted, integrated type with extruded aluminium housing integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 100 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed connecting up with 2/3 core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories internally prewired and including necessary taking down the old unserviceable fitting complete all as specified.
112S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including provision of blanking plates as required and taking down the old one complete all as specified Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57300270
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.76 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Bldg No P-30 (Rp Dump Store) Of Certain Mil Unit And special Repair Of Bathroom Near Trg Node (Np-01), Bathroom Near Trg Cell (P-50) And Bathroom Near Mt Store (P-47) Of Certain Mil Unit Under Ge (S) Binnaguri
Basic Detail
Tender No 8830/E8
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 01 Sep 2026
Submission Date 15 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 29.76 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
394e67b1-a3e1-42e3-a363-06029524cca7.html
BOQ_875919.xls
TENDERDOCUS8830.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

394e67b1-a3e1-42e3-a363-06029524cca7.html

xls

BOQ_875919.xls

rar

TENDERDOCUS8830.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender