Tender For Construction Of Steel Structure Roof For Practice Swimming Pool At Voc Birds Park, Central Zone. Roc No.3182/2026/Md5
Tender Value
1.80 Crore
Estimated cost
Bid Submission
15 Sep 2026
11 days left
EMD
1.80 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Steel Structure Roof For Practice Swimming Pool At Voc Birds Park, Central Zone. Roc No.3182/2026/Md5
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 2 | First Depth |
| 3 | Second Depth |
| 4 | Plinth Beam |
| 5 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 6 | Plain Cement Concrete 1:5:10 (one part of cement, five part of Crushed Stone Sand (M- Sand) and Ten part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 7 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 |
| 8 | Footings Centering |
| 9 | Plinth Beam Centering |
| 10 | Column Centering |
| 11 | Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. |
| 12 | Foundation and Basement |
| 13 | Ground Floor |
| 14 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. |
| 15 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 16 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 17 | Fabricating supplying and fixing of pre painted galvanium colour sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 18 | Fabricating supplying and fixing of roof with Poly carbonate sheet of 6mm thcik with any colour or any other approved design and to be fixed with shelf tapping screws, plastic washer. The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets. The sheet to be fixed with making suitable corrugated, cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 19 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 4 3/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 20 | Ground Floor Brick Work |
| 21 | Plastering with cement mortar 1:3 (One part of Cement and three part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 22 | Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification. (Sl.No.395) |
| 23 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. (Sl.No.404) |
| 24 | Pre-Painted Galvanized Iron Fixed Louvered Ventilators with Glass and Grill: Providing and fixing louvered ventilator fabricated from roll formed sections made of galvanized steel colour coated / powder coated (Base steel as per IS 513 'D' quality, galvanized as per IS 277 with zinc of 120 grams / sqm.) with total coated thickness of 0.58mm.Paint specification: Coated sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns.Dimensions of sections: The section for external frame should be of 57mm x 33mm.Fixing details: The section should be cut to length, joined with profile to profile component. Accessories: Glass holding flanges made of glass filled nylon.Glass: Louvers should be provided with 4mm pinhead glass.Grill: Ventilator should be provided with grill made of 10mm Square MS bars to 12mm x 5mm flat at 4 intervals. Total grill unit should be powder coated and fixed to ventilator frame with screws.The above frames should be fixed to brick / concrete masonry walls and floor by means of self-expanding screws. |
| 25 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 26 | Supply and Installation of Fire Rated HMPS - Door with Frame of GI 1.2mm Thick Shutter and 1.6mm Thick Opening with Size of Vision Panel 200x300mm. The Door Having 2hrs Fire Rated with all fittings including Hinges, Fasteners complete as per standard specification. including cost and conveyance of all materials to site etc. |
| 27 | Supply, Installation of high-performance Rain gutters have corrugated designs to increase strength and durability. A higher outer lip can prevent overflow during heavy rains. Provide extra strength and durability for the gutter. : Galvanized steel, rust-proof brackets, with a recommended spacing. • Elbows For corner and slope adjustments. Stainless steel, corrosion-proof fasteners to secure the brackets. Specify Galvanized Iron polished sheet of 3.0 mm thickness.200mm width x height(200 to 225mm) With Suitable Downtake Pipe. color should be match with roof sheet. |
| 28 | Supply, Installation, Testing and Commissioning of Wind operated Turbo Air Ventilator with base for prefabricated Ground based / Roof Top BTS cabin/shelter consisting of following specification including making necessary opening on side wall of the BTS shelter including cutting, drilling, making water leak proof sealing arrangement, etc. complete as required. Turbo Ventilator having throttle Dia: 600 mm, No. of Vanes/Blades: 42, Vane/Blade Thickness minimum 0.5mm thick, Material: Aluminium. The Connecting assembly shall have high quality permanently lubricated and sealed ZZ- steel ball bearings. The bearings shall not be exposed to dust etc. It shall be ensured that the ventilator head is perpendicular to the ground. |
| 29 | Supply and fixing of 120 Watts Mid Bay Light with Terminal Box including all accessories copper leads from terminals to the fitting. |
| 30 | Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End |
| 31 | Supply and fixing of 20W 4 Feet LED Fitting with (Higher End) complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube |
| 32 | Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one No 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 18 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with Earth connection only. |
| 33 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (like standard make) |
| 34 | Supply and Laying of 3.5C x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 35 | Supply and fixing of brass cable gland for 3.5C x 25 sq.mm. LTUG armoured cable with earth connection |
| 36 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Lower End |
| 37 | Wiring with 2 x4 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A/6A 3 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 4 sq.mm copper wire for Open MS conduit 15A Plug point ( 8 points / Coil) Higher End |
| 38 | Supply and Run of 3 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 39 | Supply and installation of 15 AMPS -6 way Neutral Link |
| 40 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40 mm with copper earth plate of size 125 mm x 50 mm x 6 mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 41 | Supply and run of 25 mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 42 | Supply and fixing of First Aid Box complete with all First Aid Medicines |
| 43 | Supply and fixing of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms |
| 44 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender