Civil Aviation Boards / Undertakings / PSU Closing in 19 days TDR #57297559

Bids Are invited for Testing Service For On-Board /Commissioned Equipment/ Instrument Related To Plant - Electrical; Insulation Resistance, Rating, High Voltage, Short-Circuit, Performance/Durability/ Safety Test, Leak Testing Facility, Service Calib

Issued by Boards / Undertakings / PSU · Chandigarh, Chandigarh
Tender Value
10.51 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
19 days left
EMD
21031
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Testing Service For On-Board /Commissioned Equipment/ Instrument Related To Plant - Electrical; Insulation Resistance, Rating, High Voltage, Short-Circuit, Performance/Durability/ Safety Test, Leak Testing Facility, Service Calibration, Bdv, Voltage .. - Servicing And Testing Of 11 Kv Ht Panel Including 03 No. Kirloskar Make 11 Kv 630Avacuum Circuit Breaker (Vcb Type-C500) , Cts, Pts, Calibration Of All Protection Relays At Each Breaker Etc. Through Manufacturer Or Authorized Service Dealer Or Specialized Agency And Submission Of Test Report Etc. Complete As Required:-1) Trip Circuit Supervision Relay (Model:- Xr351) :- 03 Set.2) High Speed Tripping Relay (Model :- B24) :- 03 Set3) Restricted Earth Fault Relay (Model :- 5B3):- 02 Set4) Auxiliary Relay :- 04 Set , For First Year , For Second Year , Servicing And Testing Of Ge Make Lt Air Circuit Breakers Of Following Ratings, Calibration Of All Protection Relays At Each Breaker Etc. Through Manufacturer Or Authorized Service Dealer Or Specialized Agency And Submission Of Test Report Etc., Complete As Required.For 1St Year , Upto 1250 A , 2500 A , Servicing And Testing Of Ge Make Lt Air Circuit Breakers (Model :- Spectronic) Of Following Ratings, Calibration Of All Protection Relays At Each Breaker Etc. Through Manufacturer Or Authorized Service Dealer Or Specialized Agency And Submission Of Test Report Etc., Complete As Required.For 2Nd Year , Upto 1250 A , 2500 A , Repairing & Rectification Of 1500 Kva, 11/0.433 Kv 3 Phase Oil-Filled Transformers By Identification Of Leakage Points & Fixing Them. The Work Shall Include Dismantling Of Required Components, Supply And Replacement Of All Gaskets By Rc-70 C Tr-9 Grade Rubberized/Nitrile Bonded Rubberized Cork Sheet Or Equivalent, O-Rings, Seals, And Hardware (Nuts, Bolts, Washers), Tightening Of Joints, Attending Bushing Leakages, Sealing Of Micro-Leakages Using Suitable Compounds, Welding/Brazing Wherever Required, And Reassembly And Restoring It Back To Normal Working Condition Etc. Complete As Required.Note:- Hydra, If Required, For Dismantling And Assembling Of Heavy Parts Is Included In Scope Of Work. , Dehydration & Filtration Of Transformer Oil By Deploying Filtration Machine At Site, Testing The Bdv And Acidity Before And After Filtration, Achieving Desired Bdv As Per Relevant Is I/C Submission Of Test Reports For 1500Kva, 11Kv/433V Transformer Of Volt Make With Oil Capacity Of Approx. Upto 885 Ltrs, Complete As Required. , For First Year , For Second Year , Supply & Topping Up The Transformer Oil Upto Required Level With New Treated Transformer Oil I/C Submission Of Oil Test Reports Etc. Complete, As And When Required. , Supply And Replacing The Silica Gel Of 1500 Kva Transformer Breathers Installed In Power Transformer At Chandigarh Airport Complete As Required. , Inspection, Servicing And Testing Of 1500 Kva , 11/0.433 Kv Transformer I/C Carrying Out Insulation Test Ht / Lt Side With 5 Kv / 1 Kv Meggar, Voltage Ratio Test, Magnetic Balance Test , Buchholz Relay Test, Flash Point Test, O.T.I. / W.T.I. / Tap Changer Operation Checking Etc. And Submission Of Reports Complete As Required At Site. , For 1St Year , For 2Ndyear , Spray Painting Of Existing 1500 Kva Transformers At Installed Position With Two Or More Coats Of Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade, Including Cleaning Of Surface, Rewriting Of Identification Marks Wherever Required, Protecting And Covering The Electrical Accessories During Painting And Removing After Work Etc. As Required. , Supply, Fixing And Testing Of Spring Charge Motor Compatible With Existing 11Kv 630A Kirloskar Make Vacuum Circuit Breaker (Type:- C500) Etc. Complete As Required. , Supply And Fixing Of Resin Cast, Indoor, Single Phase Single Pole Insulated Earthed Type Voltage Transformers, Complete With Built In H. V. Fuse & Confirming To Is:16227-1&3/2015 Or Upto Date Amendments Etc Complete As Require. Potential Transformer Details Are As Follows:- Ratio:11000/√3/110/√3/110/√3Hsv: 12 Kv Il: 12/28/75 Kv Kvp Vf: 1.2 Cont & 1.9 For 8 Hrs. Freq: 50 Hz Insulation Class: Bsec.1 :100 Va Class:1.0Sec.2 :100 Va Class:3P

BOQ

Sl. No. Item TitleItem Description
1Servicing and Testing of 11 KV HT Panel including 03 No. Kirloskar make 11 KV 630AVacuum circuit breaker (VCB Type-C500) , CT's, PT's, calibration of all Protection relays at each breaker etc. through Manufacturer or Authorized Service Dealer or Specialized Agency and submission of Test Report etc. complete as required:-1) Trip Circuit Supervision Relay (Model:- XR351) :- 03 Set.2) High speed Tripping Relay (Model :- B24) :- 03 Set3) Restricted Earth Fault relay (Model :- 5B3):- 02 Set4) Auxiliary Relay :- 04 SetServicing and Testing of 11 KV HT Panel including 03 No. Kirloskar make 11 KV 630AVacuum circuit breaker (VCB Type-C500) , CT's, PT's, calibration of all Protection relays at each breaker etc. through Manufacturer or Authorized Service Dealer or Specialized Agency and submission of Test Report etc. complete as required:-1) Trip Circuit Supervision Relay (Model:- XR351) :- 03 Set.2) High speed Tripping Relay (Model :- B24) :- 03 Set3) Restricted Earth Fault relay (Model :- 5B3):- 02 Set4) Auxiliary Relay :- 04 Set
2For First YearFor First Year
3For Second YearFor Second Year
4Servicing and testing of GE make LT Air Circuit Breakers of following ratings, Calibration of all Protection relays at each breaker etc. through Manufacturer or Authorized Service Dealer or Specialized Agency and submission of Test Report etc., complete as required.For 1st yearServicing and testing of GE make LT Air Circuit Breakers of following ratings, Calibration of all Protection relays at each breaker etc. through Manufacturer or Authorized Service Dealer or Specialized Agency and submission of Test Report etc., complete as required.For 1st year
5Upto 1250 AUpto 1250 A
62500 A2500 A
7Servicing and Testing of GE make LT Air Circuit Breakers (Model :- Spectronic) of following ratings, Calibration of all Protection relays at each breaker etc. through Manufacturer or Authorized Service Dealer or Specialized Agency and submission of Test Report etc., complete as required.For 2nd yearServicing and Testing of GE make LT Air Circuit Breakers (Model :- Spectronic) of following ratings, Calibration of all Protection relays at each breaker etc. through Manufacturer or Authorized Service Dealer or Specialized Agency and submission of Test Report etc., complete as required.For 2nd year
8Upto 1250 AUpto 1250 A
92500 A2500 A
10Repairing & rectification of 1500 kVA, 11/0.433 KV 3 phase Oil-Filled Transformers by identification of leakage points & fixing them. The work shall include dismantling of required components, supply and replacement of all gaskets by RC-70 C TR-9 Grade rubberized/nitrile bonded rubberized cork sheet or equivalent, O-rings, seals, and hardware (nuts, bolts, washers), tightening of joints, attending bushing leakages, sealing of micro-leakages using suitable compounds, welding/brazing wherever required, and reassembly and restoring it back to normal working condition etc. complete as required.Note:- Hydra, if required, for dismantling and assembling of heavy parts is included in scope of work.Repairing & rectification of 1500 kVA, 11/0.433 KV 3 phase Oil-Filled Transformers by identification of leakage points & fixing them. The work shall include dismantling of required components, supply and replacement of all gaskets by RC-70 C TR-9 Grade rubberized/nitrile bonded rubberized cork sheet or equivalent, O-rings, seals, and hardware (nuts, bolts, washers), tightening of joints, attending bushing leakages, sealing of micro-leakages using suitable compounds, welding/brazing wherever required, and reassembly and restoring it back to normal working condition etc. complete as required.Note:- Hydra, if required, for dismantling and assembling of heavy parts is included in scope of work.
11Dehydration & Filtration of Transformer oil by deploying Filtration Machine at site, testing the BDV and acidity before and after filtration, achieving desired BDV as per relevant IS i/c submission of test reports for 1500KVA, 11KV/433V Transformer of VOLTAMP make with Oil capacity of approx. upto 885 Ltrs, complete as required.Dehydration & Filtration of Transformer oil by deploying Filtration Machine at site, testing the BDV and acidity before and after filtration, achieving desired BDV as per relevant IS i/c submission of test reports for 1500KVA, 11KV/433V Transformer of VOLTAMP make with Oil capacity of approx. upto 885 Ltrs, complete as required.
12For First YearFor First Year
13For Second YearFor Second Year
14Supply & Topping up the transformer oil upto required level with new treated transformer oil i/c submission of oil test reports etc. complete, as and when required.Supply & Topping up the transformer oil upto required level with new treated transformer oil i/c submission of oil test reports etc. complete, as and when required.
15Supply and replacing the Silica gel of 1500 KVA Transformer Breathers installed in power transformer at Chandigarh airport complete as required.Supply and replacing the Silica gel of 1500 KVA Transformer Breathers installed in power transformer at Chandigarh airport complete as required.
16Inspection, Servicing and Testing of 1500 KVA , 11/0.433 KV Transformer i/c carrying out Insulation Test HT / LT side with 5 KV / 1 KV Meggar, Voltage Ratio Test, Magnetic Balance Test , Buchholz Relay Test, Flash point test, O.T.I. / W.T.I. / Tap Changer Operation checking etc. and submission of reports complete as required at site.Inspection, Servicing and Testing of 1500 KVA , 11/0.433 KV Transformer i/c carrying out Insulation Test HT / LT side with 5 KV / 1 KV Meggar, Voltage Ratio Test, Magnetic Balance Test , Buchholz Relay Test, Flash point test, O.T.I. / W.T.I. / Tap Changer Operation checking etc. and submission of reports complete as required at site.
17For 1st YearFor 1st Year
18For 2ndYearFor 2ndYear
19Spray Painting of existing 1500 KVA Transformers at installed position with two or more coats of synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface, rewriting of identification marks wherever required, protecting and covering the electrical accessories during painting and removing after work etc. as required.Spray Painting of existing 1500 KVA Transformers at installed position with two or more coats of synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface, rewriting of identification marks wherever required, protecting and covering the electrical accessories during painting and removing after work etc. as required.
20Supply, Fixing and testing of Spring charge motor compatible with existing 11KV 630A Kirloskar make Vacuum Circuit breaker (Type:- C500) etc. complete as required.Supply, Fixing and testing of Spring charge motor compatible with existing 11KV 630A Kirloskar make Vacuum Circuit breaker (Type:- C500) etc. complete as required.
21Supply and fixing of Resin Cast, Indoor, single phase single pole insulated 'Earthed Type' Voltage Transformers, complete with built in H. V. Fuse & Confirming to IS:16227-1&3/2015 or upto date amendments etc complete as require. Potential transformer details are as follows:- Ratio:11000/√3/110/√3/110/√3HSV: 12 kV IL: 12/28/75 kV kVp VF: 1.2 Cont & 1.9 for 8 hrs. Freq: 50 Hz Insulation Class: BSec.1 :100 VA Class:1.0Sec.2 :100 VA Class:3PSupply and fixing of Resin Cast, Indoor, single phase single pole insulated 'Earthed Type' Voltage Transformers, complete with built in H. V. Fuse & Confirming to IS:16227-1&3/2015 or upto date amendments etc complete as require. Potential transformer details are as follows:- Ratio:11000/√3/110/√3/110/√3HSV: 12 kV IL: 12/28/75 kV kVp VF: 1.2 Cont & 1.9 for 8 hrs. Freq: 50 Hz Insulation Class: BSec.1 :100 VA Class:1.0Sec.2 :100 VA Class:3P

AI Tender Summary

OUR REF NO 57297559
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 10.51 Lakhs
LAST DATE 22-09-2026
Authority
Authority Name Airports Authority Of India
Work Description Bids Are invited for Testing Service For On-Board /Commissioned Equipment/ Instrument Related To Plant - Electrical; Insulation Resistance, Rating, High Voltage, Short-Circuit, Performance/Durability/ Safety Test, Leak Testing Facility, Service Calibration, Bdv, Voltage .. - Servicing And Testing Of 11 Kv Ht Panel Including 03 No. Kirloskar Make 11 Kv 630Avacuum Circuit Breaker (Vcb Type-C500) , Cts, Pts, Calibration Of All Protection Relays At Each Breaker Etc. Through Manufacturer Or Authorized Service Dealer Or Specialized Agency And Submission Of Test Report Etc. Complete As Required:-1) Trip Circuit Supervision Relay (Model:- Xr351) :- 03 Set.2) High Speed Tripping Relay (Model :- B24) :- 03 Set3) Restricted Earth Fault Relay (Model :- 5B3):- 02 Set4) Auxiliary Relay :- 04 Set , For First Year , For Second Year , Servicing And Testing Of Ge Make Lt Air Circuit Breakers Of Following Ratings, Calibration Of All Protection Relays At Each Breaker Etc. Through Manufacturer Or Authorized Service Dealer Or Specialized Agency And Submission Of Test Report Etc., Complete As Required.For 1St Year , Upto 1250 A , 2500 A , Servicing And Testing Of Ge Make Lt Air Circuit Breakers (Model :- Spectronic) Of Following Ratings, Calibration Of All Protection Relays At Each Breaker Etc. Through Manufacturer Or Authorized Service Dealer Or Specialized Agency And Submission Of Test Report Etc., Complete As Required.For 2Nd Year , Upto 1250 A , 2500 A , Repairing & Rectification Of 1500 Kva, 11/0.433 Kv 3 Phase Oil-Filled Transformers By Identification Of Leakage Points & Fixing Them. The Work Shall Include Dismantling Of Required Components, Supply And Replacement Of All Gaskets By Rc-70 C Tr-9 Grade Rubberized/Nitrile Bonded Rubberized Cork Sheet Or Equivalent, O-Rings, Seals, And Hardware (Nuts, Bolts, Washers), Tightening Of Joints, Attending Bushing Leakages, Sealing Of Micro-Leakages Using Suitable Compounds, Welding/Brazing Wherever Required, And Reassembly And Restoring It Back To Normal Working Condition Etc. Complete As Required.Note:- Hydra, If Required, For Dismantling And Assembling Of Heavy Parts Is Included In Scope Of Work. , Dehydration & Filtration Of Transformer Oil By Deploying Filtration Machine At Site, Testing The Bdv And Acidity Before And After Filtration, Achieving Desired Bdv As Per Relevant Is I/C Submission Of Test Reports For 1500Kva, 11Kv/433V Transformer Of Volt Make With Oil Capacity Of Approx. Upto 885 Ltrs, Complete As Required. , For First Year , For Second Year , Supply & Topping Up The Transformer Oil Upto Required Level With New Treated Transformer Oil I/C Submission Of Oil Test Reports Etc. Complete, As And When Required. , Supply And Replacing The Silica Gel Of 1500 Kva Transformer Breathers Installed In Power Transformer At Chandigarh Airport Complete As Required. , Inspection, Servicing And Testing Of 1500 Kva , 11/0.433 Kv Transformer I/C Carrying Out Insulation Test Ht / Lt Side With 5 Kv / 1 Kv Meggar, Voltage Ratio Test, Magnetic Balance Test , Buchholz Relay Test, Flash Point Test, O.T.I. / W.T.I. / Tap Changer Operation Checking Etc. And Submission Of Reports Complete As Required At Site. , For 1St Year , For 2Ndyear , Spray Painting Of Existing 1500 Kva Transformers At Installed Position With Two Or More Coats Of Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade, Including Cleaning Of Surface, Rewriting Of Identification Marks Wherever Required, Protecting And Covering The Electrical Accessories During Painting And Removing After Work Etc. As Required. , Supply, Fixing And Testing Of Spring Charge Motor Compatible With Existing 11Kv 630A Kirloskar Make Vacuum Circuit Breaker (Type:- C500) Etc. Complete As Required. , Supply And Fixing Of Resin Cast, Indoor, Single Phase Single Pole Insulated Earthed Type Voltage Transformers, Complete With Built In H. V. Fuse & Confirming To Is:16227-1&3/2015 Or Upto Date Amendments Etc Complete As Require. Potential Transformer Details Are As Follows:- Ratio:11000/√3/110/√3/110/√3Hsv: 12 Kv Il: 12/28/75 Kv Kvp Vf: 1.2 Cont & 1.9 For 8 Hrs. Freq: 50 Hz Insulation Class: Bsec.1 :100 Va Class:1.0Sec.2 :100 Va Class:3P
Basic Detail
Tender No GEM/2026/B/7983839
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 01 Sep 2026
Submission Date 22 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 10.51 Lakhs
Tender Fee Ref. Documents
EMD 21031
Exemption Not Available
Document List
a8111399-8118-4d3c-a63d-e0184141a20b.pdf
1788261108.xlsx
1788261217.pdf
1788261244.pdf
1788261286.pdf
DNITTRANS_dfdec111-6b0b-4170-b2c81788261883963_MGREECHD.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

a8111399-8118-4d3c-a63d-e0184141a20b.pdf

xlsx

1788261108.xlsx

pdf

1788261217.pdf

pdf

1788261244.pdf

pdf

1788261286.pdf

pdf

DNITTRANS_dfdec111-6b0b-4170-b2c81788261883963_MGREECHD.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders