Bids Are invited for Custom Bid For Services - ---- - Safe Carriage Of Following Material From Electricty Store Center Hathras To Pit Site Of Work Through The Kacha And Pakka Road Including Loading And Unloading At The Respective Ends Including The C
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - ---- - Safe Carriage Of Following Material From Electricty Store Center Hathras To Pit Site Of Work Through The Kacha And Pakka Road Including Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Etc. Which Required For Proper Completion Of Work.(Distance 00-50 Kms.) , 8.5/9 Mtr. Long Pcc Poles. , 11 Mtr. Stp Poles , 11 Kv X-Arms, Weasal Conductor, G.I Wire,Disc Insulators, Pin Insulators, Cl S And Other Required Line Material, If Any. , Replacement Of Damaged 8.5 Mtr. Long Pcc Pole By Digging Of Pits In Kharanja/Mettalic Road And Dismantling Of All 11Kv/Lt Accessories From The Existing / Damaged Pole And Errection Of Single New Pole Including Fixing Of All Accessories. , Replacement Of Damaged 11 Mtr. Long Stp Pole By Digging Of Pits In Kharanja/Mettalic Road And Dismantling Of All 11Kv/33 Kv Accessories From The Existing / Damaged Pole And Errection Of Single New Stp Pole Including Fixing Of All Accessories. , Replacement Of Damaged 8.5 Meter Long Of Double Pcc Pole (First Opening Of All Accessories & Then Removing Damaged Poles),Under Errection D/P Including Fixing Of Disc Insulators With Fitting And Other Lt/11 Kv Accessories As Per Respo Manual And As Per Direction Of Supervising Engineer, The Double Pole Shall Be Grouted In Ratio 1:4:8 (Cement, Sand And Brick Ballast/ Stone Ballast) Including Cost Of Cement, Sand, Brick Ballast/ Stone Ballast, Stone Pad As Per Actual Requirement At Site , Straightening Of Tilted Single Pcc Poles In The Existing Lines As Per Direction Of Supervising Engineer. , Straightening Of Tilted Single St Poles In The Existing Lines As Per Direction Of Supervising Engineer. , Straightening Of Tilted Double Poles In The Existing Lines As Per Direction Of Supervising Engineer. , Straightening Of Tilted 11 Kv Cross Arms In The Existing Lines As Per Direction Of Supervising Engineer. , Retitling Of Old Stay With Nojling & Binding. , Providing Nuts & Bolts With Washers , Replacement Of Following Damaged Accessories In 33/11 Kv /Lt Line - , 11 Kv X-Arms, 11 Kv Pin Insulators With Pin & Nut & Bolt , F Cl , 11 Kv Disc Insulator With Fiting , Laying, Sagging And Stringing And Nozzling / Binding Etc. Of New & Old Acsr Weasal Conductor / Gi In 11 Kv / Lt Lines As Per Respo Manual And As Per Direction Of Supervising Engineer. , Acsr Weasel Conductor , Re- Sagging And Stringing Of Existing Following Conductor In Ht /Lt Line As Per Direction Of Supervising Engineer. , Acsr Weasel Conductor , 50/95/120 Sqmm. Areal Bunch Conductor , Acsr Dog Conductor , Cutting, Chopping, Triming Of Tree Branches To Clear The Line Route To Give 2 Mtr. Horizontal And Vertical Clearance To The Line Coming In The Route Of Different Feeders As Per Direction Of Supervising Engineer , Re Gaurding/Gaurding Of 11 Kv Line By Laying, Sagging Stringing And Binding Of 2 Nos Parallel Gi Wire 6 Swg After Providing Fabrication And Fixing Of Gaurding Angle And Fabrication And Fixing Of X Gaurds, (Tillis) Of Gi Wire At Distance Of 3 Meter , Opening Of Service Cable Of Consumer And Re-Connecting The Same After Resagging Of Conductor.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Safe Carriage of following material from Electricty store center Hathras to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.) | Safe Carriage of following material from Electricty store center Hathras to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.) |
| 2 | 8.5/9 Mtr. long PCC Poles. | 8.5/9 Mtr. long PCC Poles. |
| 3 | 11 Mtr. STP Poles | 11 Mtr. STP Poles |
| 4 | 11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps and other required line material, if any. | 11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps and other required line material, if any. |
| 5 | Replacement of damaged 8.5 Mtr. long PCC pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/LT accessories from the existing / damaged pole and errection of single new pole including Fixing of all accessories. | Replacement of damaged 8.5 Mtr. long PCC pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/LT accessories from the existing / damaged pole and errection of single new pole including Fixing of all accessories. |
| 6 | Replacement of damaged 11 Mtr. Long STP pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/33 KV accessories from the existing / damaged pole and errection of single new STP pole including Fixing of all accessories. | Replacement of damaged 11 Mtr. Long STP pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/33 KV accessories from the existing / damaged pole and errection of single new STP pole including Fixing of all accessories. |
| 7 | Replacement of damaged 8.5 meter long of Double PCC Pole (first opening of all accessories & then removing damaged poles),under Errection D/P including fixing of Disc Insulators with fitting and other LT/11 KV accessories as per RESPO manual and as per direction of supervising engineer, The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast) including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site | Replacement of damaged 8.5 meter long of Double PCC Pole (first opening of all accessories & then removing damaged poles),under Errection D/P including fixing of Disc Insulators with fitting and other LT/11 KV accessories as per RESPO manual and as per direction of supervising engineer, The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast) including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site |
| 8 | Straightening of tilted single PCC Poles in the existing lines as per direction of supervising engineer. | Straightening of tilted single PCC Poles in the existing lines as per direction of supervising engineer. |
| 9 | Straightening of tilted single ST Poles in the existing lines as per direction of supervising engineer. | Straightening of tilted single ST Poles in the existing lines as per direction of supervising engineer. |
| 10 | Straightening of tilted Double Poles in the existing lines as per direction of supervising engineer. | Straightening of tilted Double Poles in the existing lines as per direction of supervising engineer. |
| 11 | Straightening of tilted 11 KV Cross Arms in the existing lines as per direction of supervising engineer. | Straightening of tilted 11 KV Cross Arms in the existing lines as per direction of supervising engineer. |
| 12 | Retitling of old stay with nojling & Binding. | Retitling of old stay with nojling & Binding. |
| 13 | Providing Nuts & Bolts with Washers | Providing Nuts & Bolts with Washers |
| 14 | Replacement of following damaged accessories in 33/11 KV /LT line - | Replacement of following damaged accessories in 33/11 KV /LT line - |
| 15 | 11 KV X-Arms, 11 KV Pin Insulators with Pin & Nut & Bolt , 'F' Clamp | 11 KV X-Arms, 11 KV Pin Insulators with Pin & Nut & Bolt , 'F' Clamp |
| 16 | 11 KV Disc Insulator With Fiting | 11 KV Disc Insulator With Fiting |
| 17 | Laying, sagging and stringing and Nozzling / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer. | Laying, sagging and stringing and Nozzling / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer. |
| 18 | ACSR Weasel conductor | ACSR Weasel conductor |
| 19 | Re- sagging and stringing of existing following conductor in HT /LT line as per direction of supervising engineer. | Re- sagging and stringing of existing following conductor in HT /LT line as per direction of supervising engineer. |
| 20 | ACSR Weasel conductor | ACSR Weasel conductor |
| 21 | 50/95/120 sqmm. Areal Bunch Conductor | 50/95/120 sqmm. Areal Bunch Conductor |
| 22 | ACSR Dog conductor | ACSR Dog conductor |
| 23 | Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer | Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer |
| 24 | Re gaurding/gaurding of 11 KV line by laying, sagging stringing and binding of 2 Nos parallel GI wire 6 SWG after providing Fabrication and fixing of gaurding angle and fabrication and fixing of X gaurds, (Tillis) of GI wire at distance of 3 meter | Re gaurding/gaurding of 11 KV line by laying, sagging stringing and binding of 2 Nos parallel GI wire 6 SWG after providing Fabrication and fixing of gaurding angle and fabrication and fixing of X gaurds, (Tillis) of GI wire at distance of 3 meter |
| 25 | Opening of service cable of consumer and re-connecting the same after Resagging of conductor. | Opening of service cable of consumer and re-connecting the same after Resagging of conductor. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender