Bids Are invited for Custom Bid For Services - ---- - Safe Carriage Of Following Material From Electricty Store Center Hts To Pit Site Of Work Through The Kacha And Pakka Road Including Loading And Unloading At The Respective Ends Including The Cost
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - ---- - Safe Carriage Of Following Material From Electricty Store Center Hts To Pit Site Of Work Through The Kacha And Pakka Road Including Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Etc. Which Required For Proper Completion Of Work.(Distance 00-50 Kms.) , Stone Pad , Holding Cl , Aluminium Paint , M/S Nut & Bolt , Suspension Cl , Dead End Cl , I Hook , Pearcing Connector , Shackel Insulator , Danger Board , Pg Cl , 8.5/9/11 Mtr. Long Pcc Poles. , 9/11 Mtr. S.T. Poles , Acsr Weasel Conductor , Acsr Rabbit Conductor , Earthing Complete , Stay Set Complete , Teoff Channel , 33/11 Kv Pin Insulator With Pin , Disc Insulator With Disc Fitting , F Bracket , 11 Kv X-Arm , 16/25/50/95/120 Sqmm. Ab Cable , Distribution Box With Cl , Guarding Angle With Cl , G.I Wire 6/8/10 Swg , Dropper Channel , Tf Base Angle , Top Channel , Fuse Set , 10 Kva Tf/ 16 Kva Tf, , 25 Kva Tf/ 63 Kva Tf, , Tpmo , Errection Of Following Poles Including Cutting Of Kharanja/Mettalic Road/Concrete Portion While Digging Pit & Complete H.T./L.T. Fittings As Per Respo Manual And As Per Direction Of Engineer Incharge Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. , Pcc Poles 8.5/9/11 Mtr. , Stp 9.0/11 Mtr. , Fixing Of Following Material As Per Respo Manual , Stone Pad , Holding Cl , Aluminium Paint , Suspension Cl , Dead End Cl , I Hook , Pearcing Connector , Shackel Insulator , Danger Board , Pg Cl , Acsr Weasel Conductor , Acsr Rabbit Conductor , 33/11 Kv Pin Insulator With Pin , Disc Insulator With Disc Fitting , F Bracket , 11 Kv X-Arm , Distribution Box With Cl , Guarding Angle With Cl , G.I Wire 6/8/10 Swg , Dropper Channel , Tf Base Angle , Top Channel , Fuse Set , Tpmo , Errection And Grouting Of Stays As Per Respo Norms And As Per Direction Of Supervising Engineer. Grouting Material I.E. Cement, Sand, Brick Ballast/Stone Ballast Etc. Shall Be Arranged By The Contractor At His Own Cost. , Fixing Of Earthing Rod As Per Respo Norms And As Per Direction Of Supervising Engineer. , Safe Installation Of Following New/Repaired Cousted T/F On Newly Constructed Double Pole In Proper Alignment Direction & Making All Ht/Lt Connection. , 10 Kva Tf, 16 Kva Tf, 25 Kva T/F, 63 Kva T/F, 100 Kva T/F , 25 Kva T/F, 63 Kva T/F, , Laying, Sagging And Stringing And Jumpering / Binding Etc. Of New & Old Acsr Weasal Conductor / Gi In 11 Kv / Lt Lines As Per Respo Manual And As Per Direction Of Supervising Engineer. , Acsr Weasal Conductor , Acsr Rabbit Conductor , 16/25/50/95/120 Sqmm. Ab Cable , Providing & Fixing Of Following Material , Nut,Bolt & Washer , Cutting, Chopping, Triming Of Tree Branches To Clear The Line Route To Give 2 Mtr. Horizontal And Vertical Clearance To The Line Coming In The Route Of Different Feeders As Per Direction Of Supervising Engineer , Guarding/Reguarding Of 11 Kv Line By Laying, Stringing, Sagging And Binding Of 2 Nos. Parallel Gi Wire 6 Swg After Providing, Fabrication And Fixing Of Guarding Angle And Fabrication And Fixing Of X-Guards (Tillis) Of Gi Wire At Distance Of 3 Mtr. , Installation Of Extra T On The Erected Poles Wherever Required Alongwith All Fitting As Per Direction Of Supervising Engineer Including The Cost Of Labour, T&P Etc, Required For Proper Completion Of Work. The T Pole Shall Be Grouted With Cement, Sand And Brick Ballast/Stone Ballast In Ratio 1:4:8 Including The Cost Of Material. , Dismentlling , Dismentlling And Removal Of Existing Line From The Various Area , Dismentlling Of Pole Stp/Pcc , Dismentlling Of Tf , Back Cartage , Acsr Weasel Conductor Scrap , Iron Scrap , 25 Kva Tf
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Safe Carriage of following material from Electricty store center Hts to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.) | Safe Carriage of following material from Electricty store center Hts to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.) |
| 2 | Stone Pad | Stone Pad |
| 3 | Holding Clamp | Holding Clamp |
| 4 | Aluminium Paint | Aluminium Paint |
| 5 | M/s Nut & Bolt | M/s Nut & Bolt |
| 6 | Suspension Clamp | Suspension Clamp |
| 7 | Dead End Clamp | Dead End Clamp |
| 8 | I Hook | I Hook |
| 9 | PEARCING CONNECTOR | PEARCING CONNECTOR |
| 10 | Shackel Insulator | Shackel Insulator |
| 11 | Danger Board | Danger Board |
| 12 | PG Clamp | PG Clamp |
| 13 | 8.5/9/11 Mtr. long PCC Poles. | 8.5/9/11 Mtr. long PCC Poles. |
| 14 | 9/11 Mtr. S.T. Poles | 9/11 Mtr. S.T. Poles |
| 15 | ACSR Weasel conductor | ACSR Weasel conductor |
| 16 | ACSR Rabbit conductor | ACSR Rabbit conductor |
| 17 | Earthing Complete | Earthing Complete |
| 18 | Stay Set Complete | Stay Set Complete |
| 19 | Teoff Channel | Teoff Channel |
| 20 | 33/11 KV Pin Insulator with Pin | 33/11 KV Pin Insulator with Pin |
| 21 | Disc Insulator with Disc Fitting | Disc Insulator with Disc Fitting |
| 22 | F Bracket | F Bracket |
| 23 | 11 KV X-Arm | 11 KV X-Arm |
| 24 | 16/25/50/95/120 sqmm. AB Cable | 16/25/50/95/120 sqmm. AB Cable |
| 25 | Distribution Box with clamp | Distribution Box with clamp |
| 26 | Guarding Angle with Clamp | Guarding Angle with Clamp |
| 27 | G.I Wire 6/8/10 SWG | G.I Wire 6/8/10 SWG |
| 28 | Dropper Channel | Dropper Channel |
| 29 | TF Base Angle | TF Base Angle |
| 30 | Top Channel | Top Channel |
| 31 | Fuse Set | Fuse Set |
| 32 | 10 KVA TF/ 16 KVA TF, | 10 KVA TF/ 16 KVA TF, |
| 33 | 25 KVA TF/ 63 KVA TF, | 25 KVA TF/ 63 KVA TF, |
| 34 | TPMO | TPMO |
| 35 | Errection of following Poles including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. | Errection of following Poles including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 36 | PCC poles 8.5/9/11 Mtr. | PCC poles 8.5/9/11 Mtr. |
| 37 | STP 9.0/11 Mtr. | STP 9.0/11 Mtr. |
| 38 | Fixing of following Material as per RESPO manual | Fixing of following Material as per RESPO manual |
| 39 | Stone Pad | Stone Pad |
| 40 | Holding Clamp | Holding Clamp |
| 41 | Aluminium Paint | Aluminium Paint |
| 42 | Suspension Clamp | Suspension Clamp |
| 43 | Dead End Clamp | Dead End Clamp |
| 44 | I Hook | I Hook |
| 45 | PEARCING CONNECTOR | PEARCING CONNECTOR |
| 46 | Shackel Insulator | Shackel Insulator |
| 47 | Danger Board | Danger Board |
| 48 | PG Clamp | PG Clamp |
| 49 | ACSR Weasel conductor | ACSR Weasel conductor |
| 50 | ACSR Rabbit conductor | ACSR Rabbit conductor |
| 51 | 33/11 KV Pin Insulator with Pin | 33/11 KV Pin Insulator with Pin |
| 52 | Disc Insulator with Disc Fitting | Disc Insulator with Disc Fitting |
| 53 | F Bracket | F Bracket |
| 54 | 11 KV X-Arm | 11 KV X-Arm |
| 55 | Distribution Box with clamp | Distribution Box with clamp |
| 56 | Guarding Angle with Clamp | Guarding Angle with Clamp |
| 57 | G.I Wire 6/8/10 SWG | G.I Wire 6/8/10 SWG |
| 58 | Dropper Channel | Dropper Channel |
| 59 | TF Base Angle | TF Base Angle |
| 60 | Top Channel | Top Channel |
| 61 | Fuse Set | Fuse Set |
| 62 | TPMO | TPMO |
| 63 | Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost. | Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost. |
| 64 | Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer. | Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer. |
| 65 | Safe Installation of following New/Repaired cousted T/F on newly constructed double pole in proper alignment direction & making all HT/LT connection. | Safe Installation of following New/Repaired cousted T/F on newly constructed double pole in proper alignment direction & making all HT/LT connection. |
| 66 | 10 KVA TF, 16 KVA TF, 25 KVA T/F, 63 KVA T/F, 100 KVA T/F | 10 KVA TF, 16 KVA TF, 25 KVA T/F, 63 KVA T/F, 100 KVA T/F |
| 67 | 25 KVA T/F, 63 KVA T/F, | 25 KVA T/F, 63 KVA T/F, |
| 68 | Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer. | Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer. |
| 69 | ACSR Weasal conductor | ACSR Weasal conductor |
| 70 | ACSR Rabbit conductor | ACSR Rabbit conductor |
| 71 | 16/25/50/95/120 sqmm. AB Cable | 16/25/50/95/120 sqmm. AB Cable |
| 72 | Providing & Fixing of Following Material | Providing & Fixing of Following Material |
| 73 | Nut,bolt & Washer | Nut,bolt & Washer |
| 74 | Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer | Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer |
| 75 | Guarding/Reguarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr. | Guarding/Reguarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr. |
| 76 | Installation of extra ''T'' on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc, required for proper completion of work. The \\"T\\" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material. | Installation of extra ''T'' on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc, required for proper completion of work. The \\"T\\" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material. |
| 77 | Dismentlling | Dismentlling |
| 78 | Dismentlling and removal of existing Line from the various area | Dismentlling and removal of existing Line from the various area |
| 79 | Dismentlling Of Pole STP/PCC | Dismentlling Of Pole STP/PCC |
| 80 | Dismentlling Of TF | Dismentlling Of TF |
| 81 | Back Cartage | Back Cartage |
| 82 | ACSR Weasel Conductor Scrap | ACSR Weasel Conductor Scrap |
| 83 | Iron Scrap | Iron Scrap |
| 84 | 25 kva TF | 25 kva TF |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender