Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #57294065

Tender For Provn Of 01 X Toilet Block (01 X Ewc & 01 Whb) Near Bldg No Ra 35 Of 127 Light Air Defence Regiment (Comp) Under Age B/R-I And Age E/M-I Of Ge (North) Meerut Cantt

Issued by Statutory Bodies & Commissions/Committees · Meerut, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Sep 2026
21 days left
EMD
9100
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 01 X Toilet Block (01 X Ewc & 01 Whb) Near Bldg No Ra 35 Of 127 Light Air Defence Regiment (Comp) Under Age B/R-I And Age E/M-I Of Ge (North) Meerut Cantt

BOQ

Name of Work:- PROVN OF 01 X TOILET BLOCK (01 X EWC & 01 WHB) NEAR BLDG NO RA 35 OF 127 LIGHT AIR DEFENCE REGIMENT (COMP) UNDER AGE B/R-I AND AGE E/M-I OF GE (NORTH) MEERUT CANTT
Sl. No. Item Description
1Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
2Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation etc and for manholes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
3Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
4Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed.
5M&L for approved soil filling under the floors, spreading and leviling in layers n.exc 25 cm thick, well ramming including watering as required complete all as specified and directed.
6M&L for hardcore of broken bricks gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed
7M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed.
8Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
9Use and waste of Form work of sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal rough surfaces of concrete complete all as specified and directed.
10M&L Form work to sides and soffits of beams lintels etc finished fair complete all as specified and directed.
11Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete. complete all as specified and directed.
12M&L for form work to the edge of concrete flat n. exc 200 mm thick. complete all as specified and directed.
13Supply & fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
14Supply & fix mild steel TMT bars 5 mm dia and over upto and including 10mm dia as in stirrups complete all as specified and directed.
15M&L RCC 1:2:4 Tybe B1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
16M & L RCC 1:2:4 Type B1 using 20 mm graded stone aggregate as in Columns, pillars etc complete all as specified and directed.
17M & L RCC 1:2:4 Type B1 using 20 mm graded stone aggregate as in beams, lintels over 1.5 m span etc complete all as specified and directed.
18M&L for RCC M 25 type A-1 using 20 mm graded stone aggregate for roof slabs supported on walls, beams and the like. complete all as specified and directed.
19M&L brick work with fly ash bricks in CM 1;6 brick straight or curved on plain exeeding 6m mean radius complete all as specified.
20M&L for 10 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
21M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces,in CM(1:4) surface finished even and smooth without using extra cement complete all as specified and directed.
22M&L for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
23M&L 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed.
24M&L Non Skid ceramic ( coloured tiles ) tiles 7 to 8 mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed
25M & L for Screed bed or bedding layer of mortar 15 mm thick in C M 1:6, for laying floor finish. complete all as specified and directed.
26M&L for glazed coloured ceramic tiles of size 450x300x7-8mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/ coloured cement to match, complete all as specified & directed.
27M & L for Screed bed or bedding layer of mortar 10 mm thick in C M 1:4, for laying floor finish. complete all as specified and directed.
28M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cement all as specified and directed.
29M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 3 mm Thick wall care putty on walls over new surfaces using roller for painting complete all as specified and directed.
30M&L for prepration of newely plastered surface and finishing the surfaces of wall with 3 mm thick wall putty and applying two coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed.
31M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
32M& L for PCC padding 1:2:4 type B1(using 20 mm graded stone aggregate) average thickness 25mm,finished fair and even without using extra cement on roof surfaces complete all as specified and directed.
33M&L Rendering 10 mm thick on fair faces of concrete surfaces, finished even and smooth without using extra cement on roof in cement mortar (1:4), complete all as specified.
34Supply only integral water proofing compound all as in specified & directed.
35M&L for cleaning of plastered /concrete surfaces and applying priming coat using bituminous primer @ 0.30 Kg/Sqm. followed by evenly a tack coat @ 1.20 Kg/Sqm. using with 85/25 grade bitumen, over laid with 3mm thick APP modified polymeric water proofing membrane with non woven polyester reinforced of weight not less than 3.6 Kg/Sqm. unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s instructions and finished top of APP water proofing polymeric membrane with a coat of hot blown industrial bitumen 85/25 grade @ 1.20 Kg/Sqm and finally finished with a coat of bituminous aluminium paint @ 0.20 Kg/Sqm complete all as specified and directed.
36S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (Rates inclusive of M.S. hold fast/ lugs or SS dash fasteners shall not be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be madecomplete all as specified & directed.
37S & F for 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid Moulded WPC door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
38S&F stainless steel heavy weight butt hinges 100mm in size complete all as specified and directed.
39S&F Aluminium, anodized barrel tower bolts of extruded section and fixed, 200 mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified.
40S&F aluminium anodized handle of size 150 mm, ISI marked, complete all as specified.
41S&F aluminium alloy, anodised, sliding door bolt 250mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed ISI marked complete all as specified.
42S&F powder coated anodised aluminium Ventilators Side or top or bottom hung type as per site requirement with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) incl stainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, with one or more rebates including S&F 5.50 mm thick Pin headed frosted glass complete all as specified and directed.
43Supply and fixing PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
44Supply and fix grating doom 100 mm dia of PTMT ( minimum weight 25 grms ) complete all as specified and directed.
45M & L for PVC (SWR) gully trap 125/110 mm, setting anf jointing with solvent cement. complete all as specified and directed.
46Supply and fix PVC bends 110mm bore, any radius complete all as specified & directed.
47S&F Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed for 20 mm pipe. complete all as specified and directed.
48S&F Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed for 15 mm pipe. complete all as specified and directed.
49Supply & fix in vitreous china wash hand basin, white, flat back of size 550x400mm (excluding taps, waste chain and plug and porcelain stopper) but including brackets suitable for 15mm dia pipe complete all as specified & directed.
50S & F soap dish MS approximate size 160*160*90 mm fixed to plugs with chromium plated brass screws. complete all as specified and directed.
51Supply & fix angular valve, 15 mm dia, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed.
52Supply & fix rotational moulded polyethylene water storage tanks 1000 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings complete all as specified & directed.
53Supply & fix in PVC low level flushing cistern of 9-10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed.
54Supply, fix 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
55Supply, fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
56Supply & fix in PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
57Supply & fix PVC ball valves, high pressure with polyethylene float and fly nut complete screwed for iron pipe 20mm bore complete all as specified & directed.
58Supply & fix vitrous china wash down water closet pan ( padestal pattern) , white ( excluding fixing bolts, flushing cistern and flush pipe). complete all as specified and directed.
59S & F Flush pipe of polyethylene or low or high density of PVC, 32 mm dia, for low level cistern. complete all as specified and directed.
60S & F white plastic seat cover for WC ( E.T ) white including MS CP or aluminium hinging device complete all as specified and directed.
61S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
62Supply & fix pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore, complete all as specified & directed.
63S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
64PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore complete all as specified and directed.
65S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers Complete all as specified and directed.
66S&F in reipair CP towel rail brass 20mm dia 600mm long with bracket CP finish complete all as specified and directed.
67S&F Glass Corner Shelf fitted in wall with screws complete all as specified and directed
68Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
69Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed.
70Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
71M&L Concrete bed to drain pipes 150mm, including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC(1:4:8) Type D-2. complete all as specified and directed.
72M&L Slat-glazed stoneware drain pipes 150 mm dia laid in trenches and jointed complete all as specified and directed.
73M&L Cement concrete in foundations, filling and mass-concrete in PCC 1:4:8 Type D-2 (using 40 mm graded stone aggregate). complete all as specified and directed.
74M & L for PCC 1:3:6 type C2 ( using 40 mm graded stone aggregate ) in surface channel and drains complete all as specified and directed.
75M & L for provn of Septic tanks, exc in ordinary soil, foundation in PCC !:2:4, brick work in CM 1:4 RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all round / fibre reinforced cover with iron frame Vent shaft and sludgechambers etc, complete for 50 users complete all as specified and directed. ( Refer TD Drg No. TD/217 )
76M &L for provn of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 m x 4.50 m effective depth complete all as specified and directed.( Refer TD Drg no. TD/309 )
77M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FR-LSH, conforming to IS: 694-1990, PVC insulated, unsheathed copper conductor and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal box suitable for fixing moduler switches, sockets, regulator etc including modular inner frame and outer plate cover with continuous green earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated multi stranded, FRLS copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed for One light point wiring controlled by one, one way switch/bell push button.The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point. (a) One light/ fan point control by one 1- way switch
78All as described item ser No 77 here-in-before but on the same board with other switches complete all as specified and directed.
79All as described item ser No 77 here-in-before but using 2.5 sqmm copper conductor with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed.
80S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and as specified.
81S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
82S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
83S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked wirh indicator and as specified.
84M&L of ceiling rose, 2 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
85S&F wall mounted LED tube light fitting 20 watt with polycarbonate housing with all accessories and fixing material complete all as specified and directed.
86S&F decorative LED tube light fitting 10 watt 2' wall mounted with extruded polycarbonate ,integrated lamp & driver with opal diffuser and decorative end plates complete with all accessories and fixing material complete all as specified and directed.
87S&F Exhaust fan with louver PVC and fixing accessories 230 Volt and 250 mm sweep mounted on aluminium frame all as specified and as directed.
88S&F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces incl taking down old u/s DB's complete all as directed by Engineer - in -charge.
89S&F MCB, SP, AC, 240 volts \\"C\\" series capacity of 06 to 32Amps, 10kA and making connections complete all as specified & directed.
90S&F MCB SPN 40 A, AC, 240V, 10KA, ISI Marked 'C' curve incl thimble etc complete all as specified and directed.
91Supply ,laying commissioning ,testing of XLPE under ground LT cable 1100 volts grade of size 6 sqmm 2 core armoured PVC sheathed with aluminium conductor heavy duty laid in trench ,fixing on wall ,under road crossing through proctection pipe etc including taking down old LT UG cable complete all as specified and directed.
92M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
93Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface all as specified and directed.
94Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed.
95Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed
96S & F GI tubing, medium grade, 25 mm bore ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed,.
97M & L 25 mm Gun metal gate valve with iron wheel head screwed both ends for iron pipe including testing complete all as specified and directed.
98M&L for making joint to existing CI/DI line incld making hole of desired size if required along with reducer and other accessories etc complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57294065
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 23-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 01 X Toilet Block (01 X Ewc & 01 Whb) Near Bldg No Ra 35 Of 127 Light Air Defence Regiment (Comp) Under Age B/R-I And Age E/M-I Of Ge (North) Meerut Cantt
Basic Detail
Tender No 8720/E8
Bidding Type Tender
Location
City Meerut
State Uttar Pradesh
Key Dates
Publish Date 01 Sep 2026
Submission Date 23 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 300
EMD 9100
Exemption Available
Document List
7e878bc7-0fcc-4f16-b130-3c81c5c3747e.html
8720TD.pdf
BOQ_882351.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

7e878bc7-0fcc-4f16-b130-3c81c5c3747e.html

pdf

8720TD.pdf

xls

BOQ_882351.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders