Tender For Provision Of Tech And Otm Accn At Ganeshbari Under Ge Dinjan
Tender Value
47.31 Crore
Estimated cost
Bid Submission
06 Oct 2026
34 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Tech And Otm Accn At Ganeshbari Under Ge Dinjan
BOQ
| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Chief Engineer Shillong Zone NAME OF WORK: PROVISION OF TECH AND OTM ACCN AT GANESHBARI UNDER GE DINJAN Contract No: CESZ/DIN/ OF 2025-2026 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.SCHEDULE A PART I(A) |
| 3 | Construction of Office and Administrative Accommodation , framed structure, complete all as specified and shown on drawings. |
| 4 | Construction of Single Officers Accommodation (for 02 Nos of Officers) , framed structure, complete all as specified and shown on drawings. |
| 5 | Construction of Officers Mess , framed structure, complete all as specified and shown on drawings. |
| 6 | Construction of JCOs Single Living Accommodation (Block A) , framed structure, complete all as specified and shown on drawings. |
| 7 | Construction of JCOs Single Living Accommodation (Block B) , framed structure, complete all as specified and shown on drawings. |
| 8 | Construction of JCO Mess and Club (For 23 Nos of JCOs) , framed structure, complete all as specified and shown on drawings. |
| 9 | Construction of Single living Accommodation for HAVs & ORs (UHQ, HQ COY, 01 COY & 02 COY) Block 'A' , framed structure, complete all as specified and shown on drawings. |
| 10 | Construction of Single living Accommodation for HAVs & ORs (UHQ, HQ COY, 01 COY & 02 COY) Block 'B' , framed structure, complete all as specified and shown on drawings. |
| 11 | Construction of Car & Scooter parking Shed including Appron , framed structure, complete all as specified and shown on drawings. |
| 12 | Construction of Servant Qtrs (For 02 Nos of Servants) , framed structure, complete all as specified and shown on drawings. |
| 13 | Construction of Servant Qtrs (For 03 Nos of Servants) , framed structure, complete all as specified and shown on drawings. |
| 14 | Construction of Cook House & Dining (For ORs Mess) , framed structure, complete all as specified and shown on drawings. |
| 15 | Construction of Religious Institute , framed structure, complete all as specified and shown on drawings. |
| 16 | Construction of Unit Run Canteen (URC) , framed structure, complete all as specified and shown on drawings. |
| 17 | Construction of Guard House & Ancillaries , framed structure including hardstanding 40 Sqm complete all as specified and shown on drawings.Note: Flag staff shall be measured and paid separately. |
| 18 | Construction of MT Store Accommodation , framed structure, complete all as specified and shown on drawings. |
| 19 | Construction of Storage Accommodation , framed structure, complete all as specified and shown on drawings. |
| 20 | Construction of Parking Space for Trailors (For 15 Nos of Trailor) including Appron, , framed structure, complete all as specified and shown on drawings. |
| 21 | Construction of Parking Space for Motor Cycle including Appron, , framed structure, complete all as specified and shown on drawings. |
| 22 | Construction of Parking Space for 2.5 Ton (For 07 Nos ) including Appron, , framed structure, complete all as specified and shown on drawings. |
| 23 | Construction of Parking Space for 3/5 Ton / Stallion MK 11 / LPTA (For 07 Nos ) including Appron, , framed structure, complete all as specified and shown on drawings. |
| 24 | Construction of Parking Space for 3/5 Ton / Lorry (For 07 Nos ) including Appron, , framed structure, complete all as specified and shown on drawings. |
| 25 | Construction of Space for 'B' Vehicle, 3.2 M HT including Appron, , framed structure, complete all as specified and shown on drawings. |
| 26 | Construction of Space for Repair Bay including Appron, , framed structure, complete all as specified and shown on drawings. |
| 27 | Construction of RCC Overhead tank of 25000 Gallon capacity with 21 M staging including pile foundation, initial pile load test as per IS 2911 Part-4, Low strain integrity test and of pile, Routine pile load test as per IS 2911 Part-4 complete all as specified and shown on drawings. |
| 28 | Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(B) |
| 29 | Lumpsum price worked out by the bidder/ tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule 'A' Part-II. |
| 30 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule 'A' Part-III. |
| 31 | Lumpsum price worked out by the bidder/ tenderer for AIR CONDITION as listed in Schedule 'A' Part-IV. |
| 32 | Lumpsum price worked out by the bidder/ tenderer for SOLAR WATER HEATER as listed in Schedule 'A' Part-V. |
| 33 | Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule 'A' Part-VI. |
| 34 | Lumpsum price worked out by the bidder/ tenderer for COOLING APPLIANCES as listed in Schedule 'A' Part-VII. |
| 35 | Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH & CULVERT as listed in Schedule 'A' Part-VIII. |
| 36 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-IX. |
| 37 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-X. |
| 38 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-XI. |
| 39 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-XII. |
| 40 | Lumpsum price worked out by the bidder/ tenderer for SECURITY WALL FENCING AND GATE as listed in Schedule 'A' Part-XIII. |
| 41 | Lumpsum price worked out by the bidder/ tenderer for AVIATION LIGHT as listed in Schedule 'A' Part-XIV. |
| 42 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-XV. |
| 43 | Sch 'A' Part-XVI (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. |
| 44 | Rough excavation and bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including cost or royality if any, transportation, taxes etc. Note: . (i) Earth required for the item, shall be supplied by contractor, from out side MOD land at his own arrangment. (ii) All cost of procurement of earth including cost of transportation, roualties, taxes etc. shall be deemed to be included in the unit rate quoted by the contractor. (iii) With referance to clause 3.6 of MES schdule Part-II on serial page No 18 it is clarified that measurement of the above item shall be of finalised embankment/traverse of filled earth after consolidation and 10% deduction shall be made from measured and calculated volume to allow for increase in bulk. |
| 45 | Supply and fix wall mounted type automatic Voltage Stabilizer of capacity 5 KVA suitable for inverter type ACs, single phase naturally air-cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% including inbuilt thermal over load protection, time delay system and low & high voltage cut-off complete all as specified & directed. (for ACs) |
| 46 | Supply and fix wall mounted type automatic Voltage Stabilizer of capacity 4 KVA suitable for inverter type ACs, single phase naturally air-cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% including inbuilt thermal over load protection, time delay system and low & high voltage cut-off complete all as specified & directed. (for ACs) |
| 47 | upply, installation, testing and commissioning of solar water heater (Flat Plate Collector) with heat exchanger type, conforming to IS 12933 & 13129 for cold region of 300 litre/ day capacity and including rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 500 Ltr capacity, triple layer as make up water tank including 20mm dia brass float valve, SS puff insulated hot water collecting tank of suitable capacity, hoisted and fixed in position on suitable steel staging as directed by GE, complete all as specified and directed. Note:- (i) The system shall be tested on completion to ensure that 200 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season. (ii) Normal water pipes and accessories from and including cold water make up tank including M.S frame angle iron staging of appropriate size and dimension using M.S angle iron of size 40mm x 40mm x 6mm and hoisting with MS flat of size 40mm x 6mm made to shape to hoist the cold water stroage tank of capacity 500 ltr upto and including hot water SS tank, all other civil & electrical works, providing electric connection with wire, MCB, conduit etc as per manufacturer's instructions as required shall deemed to be included in unit rate quoted |
| 48 | upply, installation, testing and commissioning of solar water heater (Flat Plate Collector) with heat exchanger type, conforming to IS 12933 & 13129 for cold region of 200 litre/ day capacity and including rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 500 Ltr capacity, triple layer as make up water tank including 20mm dia brass float valve, SS puff insulated hot water collecting tank of suitable capacity, hoisted and fixed in position on suitable steel staging as directed by GE, complete all as specified and directed. Note:- (i) The system shall be tested on completion to ensure that 200 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season. (ii) Normal water pipes and accessories from and including cold water make up tank including M.S frame angle iron staging of appropriate size and dimension using M.S angle iron of size 40mm x 40mm x 6mm and hoisting with MS flat of size 40mm x 6mm made to shape to hoist the cold water stroage tank of capacity 500 ltr upto and including hot water SS tank, all other civil & electrical works, providing electric connection with wire, MCB, conduit etc as per manufacturer's instructions as required shall deemed to be included in unit rate quoted |
| 49 | Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed.Note : - Length of earth strip and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately. |
| 50 | M & L for DMC insulator coated finish minimum height 60 mm, length 50 mm, width 50 mm & thickness 10 mm complete all as specified and directed. |
| 51 | S & F of Hot water storage (Geyser) 25 Ltrs capacity ,BEE 5 star rated, vertical type, digital temperature display with suitable size of fastner and incl provision and connecting up of ss braided pipe with adopter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glassline coating / percelain Enamel Coating / Titanium Enamel Coating / Nano Blue Diamond Glass Coating / Coating with Single Weld line tank and outer body material ABS with high pressure with standing capacity upto 8 bar presuure, Multiple safety systems for protection against dry heating, overheating and over pressure,IPX4 waterproof technology for longer product life having heating element 2 KW and minimum two year warranty on product, minimum 3 years warranty on heating element 5 years on tank complete all as specified and directed. . |
| 52 | Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having storage capacity of 180 litre and nominal cooling capacity of 150 Litres per hour complete all as specified and directed. |
| 53 | Supply, installation, commis-sioning of refrigerator, electric driven (single phase), capacity 236 Litres, BEE not less than 3 star rated, frost free, double door, inverter technology compressor complete all as specified and directed. |
| 54 | Supply, installation, commis-sioning of refrigerator, electric driven (single phase), capacity 256 Litres, BEE not less than 3 star rated, frost free, double door, inverter technology compressor complete all as specified and directed. |
| 55 | Supply, installation, commis-sioning of refrigerator, electric driven (single phase), capacity 301 Litres, BEE not less than 3 star rated, frost free, double door, inverter technology compressor complete all as specified and directed. |
| 56 | Supply, installation, commis-sioning of refrigerator, electric driven (single phase), capacity 415 Litres, BEE not less than 3 star rated, frost free, double door, inverter technology compressor complete all as specified and directed. |
| 57 | Supply and fix wall mounted type automatic Voltage Stabilizer of capacity 3 KVA suitable for inverter type single phase AC, naturally air-cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% including inbuilt thermal over load protection, time delay system and low & high voltage cut-off complete all as specified & directed. |
| 58 | Supply & Fix of Electric run kitchen chimney wall mounted (T-shaped) with metal body (CRCA, powder coated) stain less steel 304 blower blade, stainless steel fited material including aluminium flexible exhuast pipe of suitable size with touch panel LED in built of cap 1200 CMH complete all as specified and directed |
| 59 | Supply, laying and jointing of ductile iron pipes of 200mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-7), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size shall be measured separately. |
| 60 | Supply, laying and jointing of ductile iron pipes of 150mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-9), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size shall be measured separately. |
| 61 | Supply, laying and jointing of ductile iron pipes of 150mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-7), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size shall be measured separately. |
| 62 | Supply, laying and jointing of ductile iron pipes of 100mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-7), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size shall be measured separately. |
| 63 | Material & Labour for Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size complete all as specified and directed. |
| 64 | S & F of Cast iron sluice valves of size 200 mm dia (8\\") class PN 1.6 ISI mark with stainless steel spindle heavy duty conforming to IS 14846 (2000) both end flanged drilled with cast iron wheel at top including nut and bolts washers and rubber gasket complete all as specified and as directed. |
| 65 | S & F of Cast iron sluice valves of size 150 mm dia (6\\") class PN 1.6 ISI mark with stainless steel spindle heavy duty conforming to IS 14846 (2000) both end flanged drilled with cast iron wheel at top including nut and bolts washers and rubber gasket complete all as specified and as directed. |
| 66 | S & F of Cast iron sluice valves of size 100 mm dia (4\\") class PN 1.6 ISI mark with stainless steel spindle heavy duty conforming to IS 14846 (2000) both end flanged drilled with cast iron wheel at top including nut and bolts washers and rubber gasket complete all as specified and as directed. |
| 67 | S & F of Cast iron sluice valves of size 80 mm dia class PN 1.6 ISI mark with stainless steel spindle heavy duty conforming to IS 14846 (2000) both end flanged drilled with cast iron wheel at top including nut and bolts washers and rubber gasket complete all as specified and as directed. |
| 68 | Drilling pilot bore hole of 250 mm dia by Reverse Rotary Drilling Method as described in IS 2800: 2019 in any kind of soil strata including hard stone/boulder upto 60 m depth below ground level, including compound/ powder like valmite, bentonite solution, local silty clay etc. to be required as per the site condition including collecting samples from different strata, preparing and submitting strata chart/ bore log all complete all as specified and directed.Note: Litholog and Electro logging should be done after the trail bore. The selection of strainer pipe slot size shall be selected after proper study of litholog and electro assembly. |
| 69 | Drilling pilot bore hole of 250 mm dia by Reverse Rotary Drilling Method as described in IS 2800: 2019 in any kind of soil strata including hard stone/boulder upto 120 metre depth and beyond 60 m depth below ground level, including compound/ powder like valmite, bentonite solution, local silty clay etc. to be required as per the site condition including collecting samples from different strata, preparing and submitting strata chart/ bore log all complete all as specified and directed. |
| 70 | Drilling pilot bore hole of 250 mm dia by Reverse Rotary Drilling Method as described in IS 2800: 2019 in any kind of soil strata including hard stone/boulder upto 150 metre depth and beyond 120 m depth below ground level, including compound/ powder like valmite, bentonite solution, local silty clay etc. to be required as per the site condition including collecting samples from different strata, preparing and submitting strata chart/ bore log all complete all as specified and directed. |
| 71 | Resistivity variation studies in bore hole drilled by electric logging of pilot bores by expert of Geology division to know the potential and temperature probes of drinking water by approved agency duly collaborated with strata chart/bore log complete all as specified and as directed. |
| 72 | Reaming 250 mm dia pilot bore to 550 mm dia bore upto 60 metre depth below ground level complete all as specified and as directed. |
| 73 | Reaming 250 mm dia pilot bore to 550 mm dia bore upto 120 metre depth and beyond 60 m depth below ground level complete all as specified and as directed. |
| 74 | Reaming 250 mm dia pilot bore to 550 mm dia bore upto 150 metre depth and beyond 120 m depth below ground level complete all as specified and as directed. |
| 75 | Supplying, assembling, jointing and lowering PVC casing pipe (CM) for water wells, plain ended, 250 mm nominal bore of pipe, min 12.5 mm wall thickness, UNPLASTICIZED type, PVC pipe conforming to IS 12818 : 2010 and fixing in position in different depth as directed, with male and female threads allowing to be fitted with other pipe in well complete all as specified and as directed. |
| 76 | Supplying, assembling, jointing and lowering PVC casing pipe (CM) for water wells, plain ended, 150 mm nominal bore of pipe, min 7.5 mm wall thickness, UNPLASTICIZED type, PVC pipe conforming to IS 12818 : 2010 and fixing in position in different depth as directed, with male and female threads allowing to be fitted with other pipe in well complete all as specified and as directed. |
| 77 | Supplying, assembling, jointing and lowering PVC ribbed Filter screen pipe for water wells, 150 mm nominal bore of pipe, min 9.5 mm wall thickness, UNPLASTICIZED type, PVC pipe conforming to IS 12818 : 2010 and fixing in position in different depth as directed, with male and female threads allowing to be fitted with other pipe in well complete all as specified and as directed. |
| 78 | Supply & installing sample box for displaying samples of strata made out of teak wood plants 25mm thick board, duly french polished out side, size of sample box 1000mm x 1000mm, required nos of samples bins 100mm x 100mm x 100mm sizes, provided with front openable glazed shutter, 25mm thick duly fitted with 2 Nos 75mm aluminium hinges and 75mm aluminium anodised hasp and staples for locking arrangement complete all as specified and directed. |
| 79 | Development of tube well in accordance with IS 2800: 2019 and IS:11189 with compressed air method (open well method), to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement complete all as specified and as directed. |
| 80 | Determining approximate yield capacity using the compressor of the drilling rig and carrying out yield test as per IS 2800: 2019 using test pump and determining the yield capacity of bore well, the rate of pumping without lowering the water level below the top boundary of the aquifer, the top of the perforations, the recommended rate of pumping complete all as specified and as directed. |
| 81 | Supply, lowering & jointing minimum 100mm dia UPVC Column pipe Safe allowable hydrostatic pressure 26kg/sq. cm heavy blue screen wire lock-each 3 m length incl housing clamp for 80 mm dia bore pipe made out of flat MS 100x10 mm thick (length 60mm) with 4 Nos 20mm dia of suitable size of bolt, nuts, washers etc including drilling holes of suitable sizes and painting 2 coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed. |
| 82 | Supply and fixing accessories for UPVC casing pipes such as UPVC socket, UPVC end cap, UPVC well cap, centre guide complete all as specified and directed. (Note : The specifications of there items should comply with the requirements for the scope of work and shall be to the complete satisfaction of the Engineer-in-Charge) |
| 83 | Supplying, designing, packing gravel (hard, insoluble and roughly rounded) of particle size ranges (2 mm to 3.35 mm, 3.35 mm to 4.75 mm, 4.75 mm to 6.3 mm, 6.3 mm to 8 mm, 8 mm to 12.5 mm) to the tube well in accordance with IS: 4097 as per the site requirement complete all as specified and as directed. |
| 84 | Carrying out testing of water sample of untreated water for all parameters mentioned in Table 1 to Table 6 of IS 10500: 2012 and specially Fluoride and arsenic from NEIST Jorhat/ DRL Tezpur or any approved Lab as approved by the GE complete all as specified and as directed. |
| 85 | Disinfection of bore well as per IS 2800: 2019 using 200 milligrams of powdered chlorine compound per litre of water present in the well and left in the well for at least 8-12 hours to ensure elimination of any bacteria complete all as specified and as directed. |
| 86 | Supply and fixing mild steel chain made of 6 mm dia rod of size 20 mm X 38 mm for holding submersible pump set/column pipe including pipe including necessary holding mild steel clamp nuts, bolts etc. complete all as specified and as directed. |
| 87 | Supply, Installation, Testing and Commissioning of submersible pump, elect driven 415 V TP suitable for 200/250 mm dia bore well supplied and installed complete (Flow Rate: 45 m3/Hr (min), Head: 80 meter (min) inclusive of 150 mtr long submersible cable PVC insulated and sheathed flat submersible cable with stranded copper conductor of size 3 core 6 Sqmm 1100 Volts grade including lugs and fixed in submsersible pump & starter etc complete all as specified & directed. |
| 88 | Supply& fixing pressure gauge with isolation cock suitable for a working pressure of zero to 14 Kg/SqCm (Liquid based High Intensity) complete all as specified and as directed. |
| 89 | S & F reducer, 150 mm X 250 mm size, made of PVC material complete all as specified and as directed. |
| 90 | Supply and fix Non Return Sluice Valve, reflux, with by-pass arrangement, 150 mm (6”) dia water mains confirming to IS-5312 Part-I class PN 1.6 complete all as specified and as directed. |
| 91 | M & L for construction of new valve chamber of size 1200 mm X 1200 mm X 1200 mm including necessary earth work in any type of soil, PCC foundation M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work (one and half brick thick) in CM 1:6 with 20 mm thick cement plaster internally and externally in two coats of (12 mm and 8 mm) in cement mortar 1:4, 3 mm thick mild steel cover of structural steel of grade E165 as per IS 15911: 2010 riveted with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel of grade E165 as per IS 15911: 2010, frame welded to base plate of size 150 mm X 12 mm and made of structural steel of grade E165 as per IS 15911: 2010, base plate fixed with 200 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate 50 mm X 50 mm X 6 mm mild steel washer, PCC benching 200 mm thick in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash as per drawing No. TD/EM/6 sheet Nos 1/2 & 2/2 of HQ CE Shillong Zone complete all as specified and as directed. |
| 92 | M & L for construction of new valve chamber of size 900 mm X 900 mm X 900 mm including necessary earth work in any type of soil, PCC foundation M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work (one and half brick thick) in CM 1:6 with 20 mm thick cement plaster internally and externally in two coats of (12 mm and 8 mm) in cement mortar 1:4, 3 mm thick mild steel cover of structural steel of grade E165 as per IS 15911: 2010 riveted with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel of grade E165 as per IS 15911: 2010, frame welded to base plate of size 150 mm X 12 mm and made of structural steel of grade E165 as per IS 15911: 2010, base plate fixed with 200 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate 50 mm X 50 mm X 6 mm mild steel washer, PCC benching 200 mm thick in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash as per drawing No. TD/EM/6 sheet Nos 1/2 & 2/2 of HQ CE Shillong Zone complete all as specified and as directed. |
| 93 | Supply, install testing and commissioning of 100 mm dia C.I. flanged type venturimeter of length about 2 mtr in main pipe line with necessery nut bolt gasket etc for fixing of chlorine dosing NRV, measurning of flow etc,completion all as specified and as directed. |
| 94 | Supply, installation, commissioning and testing of LT feeder piller box of size 900x1200x300 mm, outdoor cubical type, floor mounted, vermin proof factory made of CRCA Sheet 3.15 mm thick and MS angle of size 40x40x5mm having suitable legs, double door both side openable with locking and key arrangement with two Nos pad lock 50 mm make Godrej/Harison, powder coated with three phase, 415 volts, 50 Hz, AC supply all as directed by Engr-in-Charge and comprising of the following:-(a) INCOMING(i) MPCB, 3 Pole, 415 Volts, 63 Amps, breaking capacity 25 KA having thermal setting 100% and magnetic setting upto 70% - 01 No(b) OUTGOING(i) Fully automatic submersible star delta pump starter with auto unit, 3 phase 415 volts, suitable relay range with short circuit protection including contactors complete up to 25 Hp Submersible Motor - 01 No (ii) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) INDICATING DEVICES(i) LED indicating lamp with holder for main supply indicating RYB (set of three) - 01 Set(ii) Indication lamp for starter power ON/OFF - 01 Nos(iii) On load Change over switch 3 phase, 415 Volts, 50 Hz of capacity 63 Amps (for Phase sequence corrector)- 01 No |
| 95 | Supply, install, testing and commissioning of Iron Removal Plant outdoor for capacity of 10000 GPH direct in-line type dual media filter system, activated carbon filter system having raw water Fe containt 3.0 PPM and treated water should have less than 0.3 PPM with all necessary civil work for foundation, Pit for valve, hardstanding for operation and maintenance, drainage for backwash water upto suitable location less than 50 mtr as per direction of Engr in Charge. |
| 96 | Sr. Item No. 2.052 Contd/...(a) TYPE OF PRE FILTER AND IRON REMOVALFILTER VESSEL : VERTICAL, SINGLE DECK AND MULTIGRADE (both)(i) Shell MS prefabricated factory made size not less than 2,100 mm dia X 2000 mm Thickness of Body, Dish end & bed plate not less than 06 mm x 8 mm(ii) Nos of pressure guage -02 Nos, No of butterfly valves-05 Nos , Nos of samplening points -02 Nos alongwith suitable size airvent line -01 No Design Pr-5Kg/cm2, Anthracite, Filtering sand, pebbles, gravels and Vessel painting (internal black bituminus, external-Enamel paint) Backwash frequency - When DP more than 0.6 kg/ cm2(b) DUAL MEDIA FILTER WITH FRONTAL PIPEING & VALVES, INLET AND OUTLET, PRESSURE GUAGE-01 No, vessel fabricated factory made size not less than 2,100 mm dia X 2000 mm Thickness of Body, Dish end & bed plate not less than 06 mm x 8 mm and Nos of pressure guage -02 Nos, No of butterfly valves-05 Nos , Nos of samplening points -02 Nos alingwith suitable size airvent line -01 No Design Pr-5Kg/cm2, media MNO2, Anthracite, Filtering sand, pebbles , gravels and vessel paniting (internal black bituminus, external-Enamel paint) Backwash frequency - When DP more than 0.6 kg/ cm2 (c) Iron Specific Resin having following specifications (i) Appearance : Dark black, moist spherical beads (ii) Bulk Density : 600-760 kgs/M³, approximately (iii) Partical Size : 0.3 to 1.2 mm, > 1.2 mm : 5.0 % maximum > 0.3 mm : 1.0% maximum (iv) Effective size : 0.45 to 0.55 mm (v) Uniformity of co-efficient : 2.8 maximun (vi) Moisture holding capacity : 48-58 % (vii) Mesh size : 12 X 52 |
| 97 | Design, supply, Installation, testing and commissioning of Automatic variable chemical dosing system to maintain residual chlorination , Residual Cl -0.5 PPM, as per details given below : Automatic Variable Chlorination dozing shall be consisting of (a) Preparation tank (500 liters), Agitator for preparation tank, gearbox for agitator (15 RPM), motor for agitator incl connected item, level gauges and level sensors ( SS 316- 02 No’s), digital flow meter and solenoid valve (Acrylic CF-8), (b) transfer pump (PP) of required capacity (c) Dosing tank (500 ltr), level sensors (low level), level gauge (01 No) Solenoid valve (F8) , Dosing pump (1W+1 SB) of required capacity (MOC PTF3) incl motor and PRV for dosing pump, (d) Drain pump of reqd capacity (PP)- 1 No (e) Residual Sensor (0-2 PPM) -01 NO and Flow cell (FC-1) of MOC-Acrylic (f) Rota meter (1/2 inch, MOC-Acrylic), Sampling (needle) valve (1/2 inch; MOC-SS 304) Flow switch (1 inch, MOC – Brass) (g) Control panel comprising of PLC, HMI, VFD Drive-02 Nos, DOL starter (03 No’s), Panel box and other connected accessories, wire (1.5 sqmm/3 core) (h) Piping system consisting of pressure relief valve (1/2”, MOC-PP) 02 Nos, Pressure gauge (0-10 Bar), MOC SS 316), Damper (1/2 inch, MOC- PP) Non return valve (1/2 inch, MOC - PP) Strainer (1/2 inch, MOC-PP) Pipe (1/2 inch, MOC UPVC) Ball valve (1/2 inch, UPVC) NOTE :- 1. Quoted rates shall be inclusive of any additional items required to execute the chlorination dozing scheme to maintain requisite drinking water quality parameter in the treated water tank .2. Standby inspection facility not to be provided in Alum dosing system. |
| 98 | Supply, Installation, testing and commissioning of Package type/ unitised 11KV/433V Outdoor Sub-station, 500 KVA made from GI enclosure cpmplete as required confirming to IEC 62271-202 only and relevant IS specifications including K-10 temperature class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 PCC foundation of suitable size extending 500mm all around the outdoor enclosure and 1000mm height (above the ground level ) complete with suitable sizes of GI pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40X40X5 mm MS all along with the corner of the foundation od CSS shall be from OEMs only. Licensed System Integrators of approved OEM are not allowed to supply .Package Substaion will have the following euipment :- |
| 99 | Sr. Item No. 2.054 Contd/..HT Swichgear :-11 KV 630 Amps 21 KA / 3 Sec Non Extensible Ring Main Unit Compact Switchgear consisting of direct cable module & 1 No motorized Circuit Breakers Module in SF6 insulated stainless enclosure with series trips, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall perferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through IC x 95 sq. mm Aluminium XLPE cable - 1 No.Vacuum Interrupter & RMU shall be of same make to ensure life cycle optimization.Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along wtih series trip coil (Modbus RS485 complaint.Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.SF6 Gas pressure indicator.Operating sequence of VCB must be O-0.3sec-CO-3 Mins CO - Protection CT shall be minimum 40/1A, 2.5VA, 5P10 - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 95 Sq.mm AI XLPE Cable, incoming cable termination is included within the scope of work - 1 setTRANSFORMER: -11/0.433KV, 500 KVA, 50Hz, Off load Tap Changer switch, Three Phase, natural ester oil type transformer in corrugated tank i) Standard IS : IS : 2026 and IS 1180 with latest amendments (2021)ii) Losses as per 1180 level 2 and Temperature rise shall be as per IS 1180 with latest amendmentsiii) Outdoor Installationiv) Vector group : Dyn 11v) Rating 500 KVA |
| 100 | Sr. Item No. 2.054 Contd/..vi) Cooling System : KNAN (K for Ester oil)vii) Winding ; Copperviii) Magnetic Core : Prime grade of M4 or betterix) High voltage : 11 KV - 50 Hzx) Low Voltage : 433 V - 50Hzxi) System highest Voltage : 12 KV at the HV sidexii) Percentage Impendance Value : As per IS 1180xiii) Manufacturer shall have NABL accredited testing labotatoryxiv) Insulation Level : HV Power Frequency (KV rms) : 28 KV HV, Impulse withstand voltage (KV peak) : 75 kVpxv) Tapping : +5% to -15% OLTC @ 2.5%xvi) HT Termination - Cable Boxxvii) LT termination - cable box and with all accessories i.e. first filling of filtered dehydrated oil and confirming to ID & standard accessories required (xviii) OEM shall have in house core cutting facility for proper control & monotoring of quality & to avoid mixing of prime core with second grade / defective core materialsLT PANELLVS PANEL 1200 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminium as 1 A./sq.mm; LT panel made up of 1.5/2 mm thick CRCA sheet. |
| 101 | Sr. Item No. 2.054 Contd/..INCOMER FROM TRANSFORMER800 Amps 433 V 50 Hz 50 KA draw out Type Microprocessor Release based MCCB - 01 No.Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S ,415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head existing End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per existing AMR infrastructure available in the station. The smart meter may be based on RF Mesh communication technology or Cellular communication technology as per site requirements with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660 V effectively earthed and CT ratio suitable as (600/5) complete - 01 NoOutgoing :- Microprocessor based MCCB 400 A, 36 KA, 4 Pole - 02 Nos (For FP- IV & Spare) Microprocessor based MCCB 250 A, 36 KA, 4 Pole - 02 Nos (For FP-I & FP-V) Thermal Magnetic type adjustable MCCB 160 A, 36 KA, 4 Pole - 02 Nos (For FP-II & Standby Panel) Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No 150 KVAR APFC panel with minimum 6 steps as per following tentive steps (50 KVAR X 1, 25 KVAR X 2, 20 KVAR X 1, 10 KVAR X 2 & 5 KVAR X 2)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturer's recommendation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type enclosure of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable designed for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment illumination lamp with door operated switch shall be provided for each compartment. |
| 102 | Boring holes under road pavement by bocky manually in any type of soil upto 250mm bore complete all as specified and directed |
| 103 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring, danger notice plate including making PCC block type 0.9 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron (FPB-1) |
| 104 | Sr. Item No. 2.056 Contd/….INCOMING:(a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B- & neutral (b) MCCB 4 Pole 250 Amp,415V, 36 KA with adjustable thermal- magnetic release type - 01 No(c) Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(d) Indicating Lamps (R, Y & B) - 01 Set OUTGOING:(a) MCCB FP 200 Amps, 415V, 36 KA, AC with adjustable thermal- magnetic release type - 02 Nos (Adm Block & Spare)(b) MCCB FP 25 Amps, 415 V, 16 KA, AC with adjustable thermal- magnetic release type - 03 Nos (Guard House, Armoury & Spare)(c) MCB SPN 20 Amps, 230 V, 10 KA - 03 Nos (Garrage 02 Nos & Spare)(d) Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 105 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring, danger notice plate including making PCC block type 0.9 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron (FPB-2) |
| 106 | Sr. Item No. 2.057 Contd/…INCOMING:(a) Aluminium bus bar capacity 250 Amps for Phase-R-Y-B- & neutral (b) MCCB 4 Pole 160 Amp,415V, 36 KA with adjustable thermal- magnetic release type - 01 No(c) Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(d) Indicating Lamps (R, Y & B) - 01 Set OUTGOING:(a) MCCB FP 63 Amps, 415 V, 16 KA, AC with adjustable thermal- magnetic release type - 04 Nos (Offrs Mess, Single Offrs, FP -3 & Spare)(b) MCB SPN 32 Amps, 230 V, 10 KA - 04 Nos (Garrage 02 Nos, Servant Qtrs & Spare)(c)Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 107 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring, danger notice plate including making PCC block type 0.9 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron (FPB-3) Near JCO Mess |
| 108 | Sr. Item No. 2.058 Contd/…INCOMING:(a) Aluminium bus bar capacity 100 Amps for Phase-R-Y-B- & neutral (b) MCCB 4 Pole 63 Amp,415V, 16 KA with adjustable thermal- magnetic release type - 01 No(c) Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(d) Indicating Lamps (R, Y & B) - 01 Set OUTGOING:(a) MCCB FP 32 Amps, 415 V, 16 KA, AC with adjustable thermal- magnetic release type - 04 Nos (JCO Living -02, JCO Mess & Spare)(b) MCB SPN 32 Amps, 230 V, 10 KA - 03 Nos (Garrage 02 Nos & Spare) |
| 109 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring, danger notice plate including making PCC block type 0.9 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron (FPB-4) |
| 110 | Sr. Item No. 2.059 Contd/…INCOMING:(a) Aluminium bus bar capacity 600 Amps for Phase-R-Y-B- & neutral (b) MCCB 4 Pole 400 Amp,415V, 36 KA with adjustable thermal- magnetic release type - 01 No(c) Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(d) Indicating Lamps (R, Y & B) - 01 Set OUTGOING:(a) MCCB FP 200 Amps, 415V, 36 KA, AC with adjustable thermal- magnetic release type - 03 Nos ( Block- I, II & Spare)(b) MCCB FP 32 Amps, 415 V, 16 KA, AC with adjustable thermal- magnetic release type - 02 Nos (OR Institute & Spare)(c) MCB SPN 20 Amps, 230 V, 10 KA - 09 Nos (Garrage 07 Nos, Baggage Room & Spare)(d) Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 111 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring, danger notice plate including making PCC block type 0.9 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron (FPB-5) |
| 112 | Sr. Item No. 2.060 Contd/…INCOMING:(a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B- & neutral (b) MCCB 4 Pole 250 Amp,415V, 36 KA with adjustable thermal- magnetic release type - 01 No(c) Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(d) Indicating Lamps (R, Y & B) - 01 Set OUTGOING:(a) MCCB FP 63 Amps, 415V, 16 KA, AC with adjustable thermal- magnetic release type - 04 Nos (MI Room, Store, Tradesmen & Spare)(b) MCCB FP 25 Amps, 415 V, 16 KA, AC with adjustable thermal- magnetic release type - 08 Nos (URC, Unit Shop,FWC, Religious Inst, MT & Spare)(c) MCB SPN 20 Amps, 230 V, 10 KA - 03 Nos (Garrage 02 Nos & Spare)(d) Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 113 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring, danger notice plate including making PCC block type 0.9 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron (Standby Supply Panel) |
| 114 | Sr. Item No. 2.061 Contd/…INCOMING:(a) Aluminium bus bar capacity 100 Amps for Phase-R-Y-B- & neutral (b) MCCB 4 Pole 63 Amp,415V, 36 KA with adjustable thermal- magnetic release type - 01 No(c) Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(d) Indicating Lamps (R, Y & B) - 01 Set OUTGOING:(a) MCCB FP 40 Amps, 415V, 16 KA, AC with adjustable thermal- magnetic release type - 02 Nos (Pump House)(b) MCCB FP 32 Amps, 415 V, 16 KA, AC with adjustable thermal- magnetic release type - 02 Nos (Dosing Pump, Street Light)(c) MCB SPN 32 Amps, 230 V, 10 KA - 01 Nos (d) Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 115 | S & F of LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 5040 lm and system wattage not less than 36 W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. |
| 116 | Sr. Item No.2.062Contd/...The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \\"FAT\\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including with necessary brackets / pipes clamps & nuts & bolts for holding the street light fitting and three core copper flexible cable of 1.5 Sqmm as required at site. The product complying to above specs in signify, LT or Endo complete all as directed. |
| 117 | Supply and fix Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit , combi climate cable glands of IP 66 / 67 for cable entry and grommets IP 65 for conduit, terminals as PVC connector heavy duty 32 Amps, 4 way for cable necessary fixing arrangements and with cable glands ,etc all as specified and directed. |
| 118 | S&F of cable PVC insulated industrial flexible FR 1100 volt grade with stranded copper conductor of size 1.5 sqmm 3 core including suitable size PVC comduit complete all as specified and directed |
| 119 | Design, Supply, Erection, Testing and commissioning including comprehensive maint for 5 years (from the date of completion of complete work) of Roof Top Solar Power Generation Plant of capacity 5.0 KWp (AC) at output Voltage 415 Volt, 50Hz, ON GRID Hybrid solar roof top with LiFePO4 batteries back up for captive use not less than three times the rated power as per specification & complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, 2. DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications complete all as specified and directedNote: 25% payment of this item shall be retained from RARs / Final bill for comprehensive maintenance and shall be paid in equal installment per month or as required during the execution of comprehensive maintenance for the period of 05 years from the date of completion. |
| 120 | Material & Labour for chemical earthing with copper earth plate electrode of size 90cm x 60 cm x 5mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the copper earth lead by means of bolts, nuts check nuts and washers of steel using copper strip 32x6mm as earthing lead connected to earthing test point including filling 2 nos bags x 25 Kg (total 50 KG) ground earth conductivity enhancing mineral compound all as specified or directed including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed.Note : - Length of earth strip and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately. |
| 121 | Supply & fix DWCPE (SN 8) 150mm inner dia pipe laid in trenches ISI marked with smooth internal and corrugated (profiled) external surface with anti rodent property and shall be conforming to IS-16098 (Part-2) : latest amendment including jointing socket/spigot with elastomeric sealing complete activities to execute and make sewer line functional complete all as specified and directed. |
| 122 | M&L for RCC septic tank conventional type for 50 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and complete all as specified and directed. |
| 123 | M & L for RCC septic tank conventional type for 100 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and complete all as specified and directed. |
| 124 | M & L for RCC septic tank conventional type for 150 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and complete all as specified and directed. |
| 125 | M & L for soakage well of size 4 m dia and 4.5 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2 & 2/2 complete all as specified and directed. |
| 126 | M & L for soakage well of size 3.25 m dia and 4.5 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2 & 2/2 complete all as specified and directed. |
| 127 | M & L for soakage well of size 1.6 m dia and 4.5 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2 & 2/2 complete all as specified and directed. |
| 128 | Material and labour for 25mm thick granite of any type and colour (table rubbed and polished) as in steps, jambs, pillars, window-cills, cooking platform and like set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 129 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 24 KW (30 KVA), 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB-IV guidelines and Comprising of followings:- |
| 130 | Sr. Item No. 2.075(contd/...)(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 24 KW(30 KVA) at outdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 24 KW (30 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \\"H\\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi) Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete. |
| 131 | Sr. Item No. 2.075(contd/...)(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d) All standard relays, circuits and protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer's drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level |
| 132 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy Duty) with sttranded copper conductor of size 1.5 Sqmm, 2 Core, 1100 Volts grade complete all as specified and directed. |
| 133 | Supply & fix solid state electronic type aviation obstruction LED light fitting double dome 10 watt with cast aluminium, poly carbonate red colour with connecting & testing complete all as specified and directed. |
| 134 | Supply and fix time switches astro type having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed. |
| 135 | S&F Modular type 3 pin 20 A Socket with SP MCB 1 No, conforming to IS 1293 : 2005 complete all as specified in IS 732 : 2019 complete all as specified and directed. (for AC & Geyser Point) |
| 136 | S&F Decorative LED type wall mounted light fitting sutable for LED lamp 9-20 W , housing- glass, frosted type, metallic frame and including one LED lamp 12 watt complete all as specified and directed. |
| 137 | Supply, Installation, testing & commissioning of LED Engagement light fitting (Red & Green), 220 V, luminaire made of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed system lumens at a system efficacy of at-least 100 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 2 KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \\"FAT\\" before dispatch as per IS 10322. The Contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. Contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed. |
| 138 | S&F MCB DB 6 Way, VTPN, modular type, double door, metallic dstribution board conforming to IEC 61439:3, suitable for flush / surface mounting with provision for MCCB as incomer and SP / DP / TP MCB as outgoing, reversible metal door, 100 A copper busbar, fully shoruded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection as specified in IS 732 : 2019 complete all as specified and directed |
| 139 | S&F MCB DB 4 Way, VTPN, modular type, double door, metallic dstribution board conforming to IEC 61439:3, suitable for flush / surface mounting with provision for MCCB as incomer and SP / DP / TP MCB as outgoing, reversible metal door, 100 A copper busbar, fully shoruded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection as specified in IS 732 : 2019 complete all as specified and directed |
| 140 | S&F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed |
| 141 | S&F Surge Protection Device (SPD) three phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed |
| 142 | S&F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specified and directed |
| 143 | S&F modular type TV socket. RJ46, 1 module complete all as specified and directed. |
| 144 | Supply, install, test and commission of LT Panel No 1, TPN 415 Volts, 50 Hz, indoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.0 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and |
| 145 | Serial item No. 2.088 continued....fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following (for SM Barack Block A & B) :- (a) MCCB 4 pole, 415 V, Microprocessor based, Adjustable range 0.7 to 1 In, 400 Amp with breaking capacity 25 KA - 1Nos (Incoming).(b) MCCB 160 Amps, 4 Pole, 50 Hz, 415 V with thermal magnectic release having rupturing capacity 25 KA - 4 Nos (01 No Spare).(c) Single Phase timer Switch - 01 Nos(d) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1Nos(e) Indicating lamp 240 volts LED type - set of three. |
| 146 | Supply, install, test and commission of LT Panel No 2, TPN 415 Volts, 50 Hz, indoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.0 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and |
| 147 | Serial item No. 2.089 continued....fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following (for Office & Admin Bldg) :- (a) MCCB 4 pole, 415 V, Microprocessor based, Adjustable range 0.7 to 1 In, 400 Amp with breaking capacity 25 KA - 1Nos (Incoming).(b) MCCB 160 Amps, 4 Pole, 50 Hz, 415 V with thermal magnectic release having rupturing capacity 25 KA - 3 Nos (01 No Spare).(c) Single Phase timer Switch - 01 Nos(d) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1Nos(e) Indicating lamp 240 volts LED type - set of three. |
| 148 | Sch 'A' Part- XVII (Provisional Lumpsum) Lumpsum price workout by the department for provisional sum of Rs ‘39,03,860.00’ for following items including of earth work, concrete work steel section etc, complete all as specified and as directed.(i) Volleyball court : 3 Nos(ii) Basket ball ground : 1 No(iii) Football & hockey ground: 1 No(iv) Badminton court: 1 No (v) Parade Ground (12467 Sqm) Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 34 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 36 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender