Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57294054

Tender For Periodical Services And Misc Repairs In Zone-I,Ii And Zone-Vi Of Various Units At Lekhapani Mil Stn Under Ge Dinjan No.2

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
35 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
13 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Periodical Services And Misc Repairs In Zone-I,Ii And Zone-Vi Of Various Units At Lekhapani Mil Stn Under Ge Dinjan No.2

BOQ

Name of Work:- PERIODICAL SERVICES AND MISC REPAIRS IN ZONE-I,II AND ZONE-VI OF VARIOUS UNITS AT LEKHAPANI MIL STN UNDER GE DINJAN NO.2
Sl. No. Item Description
1Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water & removal of debris off the premises etc. complete all as specified & directed by Engineer in Charge.
2M&L for rendering 15mm thick in CM 1:4 in brick/concrete surfaces up to 8 Mtr height of building, finished even and smooth without using extra cement with and including using liquid WPC @ 200ml per 50 kg of cement complete all as specified & directed by Engineer in Charge (WPC shall be measured and paid separately)
3Supply only Liquid water proofing compound, complete all as specified & directed by Engineer in Charge
4Complete removal of existing treatment on wall/ roof projections incl facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust loose paint etc by skilled labour complete all as specified & directed by Engineer in Charge
5M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included.
6M & L for one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted/10 sqmtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.Note : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) 05 years guarantee of painting work will be admissible after date of completion
7M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coats of paint complete all as specified and directed.Note : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.
8M&L for rendering 15mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement complete all as specified & directed by Engineer in Charge
9M&L for rendering 15mm thick in CM 1:4 and finished fair and even without using extra cement complete all as specified & directed by Engineer in Charge
10M & L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed by Engineer in Charge
11M&L Prepration of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified & directed by Engineer in Charge
12M&L for preparation of old plastered surfaces of walls,by washing,rubbing down and stopping of distempered and painted surfaces etc.and applying one coat of distemper oil emulsion complete all as specified & directed by Engineer in Charge
13M&L for complete removal of existing treatment on wall etc and applying two coats of distemper oil emulsion including 1 mm thick wall care putty complete all as specified & directed by Engineer in Charge
14M&L for preparation of old plastered surfaces of wall and applying one coat of white wash complete all as specified & directed by Engineer in Charge
15M&L for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified & directed by Engineer in Charge
16M&L for preparation of old painted or plastered surfaces of walls etc by washing, rubbing down and applying one coat of cement base paint complete all as specified & directed by Engineer in Charge.
17M&L preparing old wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer in Charge.
18M&L for preparation of old steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying one coat of synthetic enamel paint complete all as specified & directed by Engineer in Charge
19Dismantling boarding, any description fixed in any position with nails complete all as specified & directed by Engineer in Charge
20M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified & directed by Engineer in Charge
21Hacking out old broken glass (any thickness, size, quality or description), from wooden frames, glazed with putty or fixed with beads complete all as specified & directed by Engineer in Charge
22S&F 2.5mm to 3mm thick PVC frosted window panes ordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5sq. m in each pane complete all as specified & directed by Engineer in Charge
23Material and labour(Roof treatment) for providing plain cement concrete with filler 1: cement 1; sand 2: agregate 4 type B1 using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified & directed by Engineer in Charge.Note : (i) Minimum thickness of PCC shall be 30mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after(ii) PCC shall be laid to acheive true slope towards the drain/weep holes.
24Material and labour (Roof treatment) for applying a coat of water proofing compound (1 part powder : 1 part liquid), of desired consistency with nylon brush @ 5 sqm/kg coverage over vertical/horizantal surface of RCC roof and parapet complete all as specified & directed by Engineer in Charge
25M&L for Water Proofing: (Roof treatment)a) Surface Preparation - Mild Chipping of the surface, Clean the Surface with Bio wash.b) If on linr leackage found ,seal it apply Bond coat.Open the cracks by making ‘V’ groove, filling cracks with Crack Filler.c) Apply carbon baesed shorter chain Bond Coat d) Providing and applying Water Base Water Proof compound one coats after surface preparation using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free particles with inhibiting characteristics having bacteria killing rate above 98% and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 75degree , permeable type with elongation (stretch ability) of more than 300%, in a structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT.e) If any crack found open and fill the crack with carbon base filler and bond coat.and use wall filler to reduce the undulation.f) Apply high penetration Bond coat two coat.g) Providing and applying Barrier Coat Paint/ Water Base Water Proof Paints 2 coats over screed concrete using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free particles with inhibiting characteristics having bacteria killing and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT per coat.
26M&L for Surface Preparation 1. Concrete surface must cleaned with wire brush/grinder to remove loose mortar and must be smooth, uniform, clean and dust free to receive the treatment. Concrete profile should be in the range of CSP 3-4. Preliminary Treatment 2. Any crack, construction joints shall be treated with Polymer modified repair mortar/ SC General purpose grout by proper grooving arrangement [10 x 5 mm] as per manufactures recommendation. 3. Block work joints, Block wall -slab interface to be packed with Polymer modified repair mortar/ SC General purpose grout. Treatment to continue up to full High of the planter wall. 4. Angle fillet - Making covering (50X50mm) using M20 Grade Concrete integral waterproofing Vitalia NEO admixed with additive 200 ml per bag of cement as per manufacturer’s specification 5. Testing by ponding water for 24-72 hours to identify surface defects min. 25 mm-100 mm, a. First Ponding Test to be on Structural Slab, b.. Second Ponding Test after waterproofing Treatment, c. Third Ponding Test after Screed laying Bore packing (Treatment steps given separately) 6. If any leak/dampness observed post water ponding Test, it needs to be pressure grouted with SmartCare General Purpose Grout. 7. Skim tape to be provided wherever dissimilar material ( Steel, PVC ) encountered, to overlap the coating.
27M&l for Damp Roof Ultra Application: - Supplying and applying High build elastomeric waterproofing coating Asian Paints SmartCare DP Ultra is a fiber reinforced elastomeric liquid applied waterproofing membrane which id formulated with PU hybrid polymers and reinforcing acrylic polymers, Resists positive hydrostatic pressure of up to 10 bars, Effectively bridges cracks up to 2.5 mm, Reduction Provides surface temperature reduction up to 12 °C, Excellent resistance to water, UV rays and ageing, The consumption to be maintained is 10sqft/L
28Material and labour for exposing cracks more than 1mm wide with tile cutter and forming V-grooves nexc 10mm wide and 10mm deep in RCC roof and filling with Anti-corrosive with high strength carbon Fiber based shorter chain Epoxy coating (Bond Coat) of finest quality, high strength, high penetration, durable, UV resistant, high scratch/ impact resistant, bacteria resistant and thermally stable, Semi transparent, mixed in proportion (4 Base : 1 Hardner) with Wall filler @ 1 Bond coat : 1.5 Wall filler in reqd consistency complete all as specified & directed by Engineer in ChargeNote : 1. Rate shall include for making surface clean,dustfree, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided.
29Material and labour for preparation of old/new plastered surfaces and applying Putty is white cement based product with dispersible polymer and functional additives for application on interior rough plasters to give a smooth surface and will form base for paint finish for interiors of the building, applied in 02 coats of total thickness 1.5mm @ 1.2 kgs/sqm complete all as specified & directed by Engineer in Charge.
30Material and Labour for 02 coats of Acrylic Regular Distemper, water based gives walls a smooth and matt finish and applied on prepared surface of wall & ceiling over a coat of approved primer @ 6.50 sqm/ltr using AUTO-ROLLER and AIR-LESS PAINT SPRAYER complete all as specified & directed by Engineer in Charge
31Providing and applying Water Base Elastomeric Finish two coats over and above one coat of Water Base Elastomeric Primer not containing toxic materials like Pb, Cr, Zn, biocides/organocides; having defect-free -particles with inhibiting characteristics having bacteria killing rate above 40% and high anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a structured self assembled dispersion system with VOC level of less than 1% , 40 micron DFT of top coat, including scaffolding, surface preparation, cleaning etc.complete all as specified & directed by Engineer in Charge
32Complete removal of existing treatment & levelling of wall/ceiling surface using MECHANICAL / ELECTRICAL OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface complete all as specified & directed by Engineer in Charge
33M&L for applying nerolac perma No Damp Primer on damaged/sepages/wet surfaces on brick/concrete and on all surfaces of roofs/balconies/chajjas etc with 10 years warranty all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57294054
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Periodical Services And Misc Repairs In Zone-I,Ii And Zone-Vi Of Various Units At Lekhapani Mil Stn Under Ge Dinjan No.2
Basic Detail
Tender No 8962/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 01 Sep 2026
Submission Date 15 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
952771f4-fc8f-458f-9e54-c09a08f1d412.html
BOQ_882296.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

952771f4-fc8f-458f-9e54-c09a08f1d412.html

xls

BOQ_882296.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders