Tender For 1.Repairing/Replacement Of Old Water Supply Line, Water Tanks Of Residential Qtrs And Cleaning Of Oht & Sump2.Replacement Of Ug Cables Of Residential & Non-Residential Buildings And Street Lights At 104 Bn Raf Aligarh Up.
Tender Overview
Project Description
Tender for 1.Repairing/Replacement Of Old Water Supply Line, Water Tanks Of Residential Qtrs And Cleaning Of Oht & Sump2.Replacement Of Ug Cables Of Residential & Non-Residential Buildings And Street Lights At 104 Bn Raf Aligarh Up.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore |
| 2 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25 mm dia nominal bore |
| 3 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 20 mm dia nominal bore |
| 4 | Providing and fixing gun metal gate valve with C.l. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 5 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm nominal bore |
| 6 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :15 mm nominal bore |
| 7 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :20 mm nominal bore |
| 8 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :25 mm nominal bore |
| 9 | Providing and fixing circular/rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge, includes all CPVC Pipes, fittings & fixtures upto distribution pipe line making necessary, holes for inlet, outlet, valves (CPVC ball valve in each tank) & over flow pipes and base support including water proofing.The tank having following brand and specifications: - (i) Brand: Sintex, Plasto, Vectus & Supreme (ii) Multi-layered tanks (6 layer) offer benefits like temperature regulation, UV protection, and resistance to bacterial growth. (iii) Minimum 10 years warranty(iv) Anti-Algae(v) ROHS European standard complaint(vi) 100% UV stability(vii) Threaded lid with UV protection(viii) Ultra durable 100% food grade virgin plastic |
| 10 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D.plastic ball.: 15 mm nominal bore, 120 mm long, weighing not less than 138 gms |
| 11 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.: 15 mm nominal bore, weighing not less than 32 gms |
| 12 | Providing, laying, jointing and testing S&S Centrifugally Cast Ductile Iron double chamber Class K-9 pressure pipes conforming to IS : 8329:2000 with restrained joints (bolt less), all complete. : 100 mm nominal dia pipe |
| 13 | Providing and laying Double Flanged (Screwed! Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 : : 100 mm dia Ductile Iron Double Flanged |
| 14 | Supplying pig lead at site of work. |
| 15 | Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints :: 100 mm diameter pipe |
| 16 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :100 mm diameter : Class II |
| 17 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 18 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 19 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :: 100 mm dia. R.C.C. pipe |
| 20 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 21 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter |
| 22 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm |
| 23 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 24 | Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. : 100 mm dia. |
| 25 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required : 4X25 Sqmm |
| 26 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required : 3.5X25 Sqmm |
| 27 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required : 4X35 Sqmm |
| 28 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required : 3.5X50 Sqmm |
| 29 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required : 3.5X70 Sqmm |
| 30 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required: 3.5X120 Sqmm |
| 31 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required: 3.5X150 Sqmm |
| 32 | Supply of following sizes & core XLPE insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip with stranded aluminium conductor cable suitable for 1.1 KV grade ISI marked conforming to IS: 7098(part-1)-1988 with amended upto date of following sizes as required: 3.5X185 Sqmm |
| 33 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficiancy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). : 72 watt |
| 34 | Supplying and fixing weather proof SMC boxes of size 168 mm x 253 mm x115 mm with transparent lid with rubber gasket having 1 no. SP MCB 6amp/10KA, 1no. Epoxy connector 4 pole, 1 no. Din bar/rail i/c fixing on wall/light pole, interconnection etc. as reqd. |
| 35 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. : 2 x 1.5 sq. mm |
| 36 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 37 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 38 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq.mm |
| 39 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. : Above 35 sq. mm and upto 95 sq. mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender