Tender For Work For Conversion Of Existing 11Kv Overhead Line To 11Kv Underground Cable For Menkurem Feeder And Kasarpal Feeder Phase 2 From 33/11Kv Substation Sal Ss Under The Jurisdiction Of S/D I, Bicholim, Goa
Tender Value
16.46 Crore
Estimated cost
Bid Submission
18 Sep 2026
16 days left
EMD
26.46 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work For Conversion Of Existing 11Kv Overhead Line To 11Kv Underground Cable For Menkurem Feeder And Kasarpal Feeder Phase 2 From 33/11Kv Substation Sal Ss Under The Jurisdiction Of S/D I, Bicholim, Goa
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Material |
| 2 | Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autimatic PLC controlled concrete batching plant and cast in a fully automatic \\"vibro-Press\\" machine with a high vibration frequency and hyraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50 mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2/(28 days strength) when tested. (13230/480) & D/C (5600/480*2) |
| 3 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.(0.2*0.45*13230)+(0.2*0.6*5600) |
| 4 | RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)=(13230+5600+5200)/50 |
| 5 | Supply & Erection of Warning tape. =(13230+5600)/1000 |
| 6 | LATERITE MASONARY WORKS: RUBBLE PACKING WITH HARD LATERITE STONE UNDER FLOORS INCLUDING WATERING RAMMING AND CONSOLIDATING ETC. IN PIPELINE TRENCHES AND OTHER FOUNDATION COMPLETE FOR: c)Single Circuit 11kV Cable Trench (0.2*0.7*13230m) & D/C 11KV cable trench (0.2*0.9*5600m) + HDD pits 0.2*0.2*5200/50 |
| 7 | Laying of 11KV UG Cable size 300Sqmm by trenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, boring as well as drawing of cable in Normal soft/hard Soil with minimum 8\\" bore size, including supply and erection of HDPE pipe 110mm, PN6, PE80, wall thickness 6.5mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650-18500 only except at entry and exis pits where minimum depth shall be 1200mm |
| 8 | Supply 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable open Trench |
| 9 | Supply 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable open Trench |
| 10 | 11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm. |
| 11 | Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 185 sqmm XLPE |
| 12 | Supply and erection of straight through joint for 3C 300 sq.mm cable (Considering length of the cable for one cable drum as 500m) |
| 13 | Supply and erection of straight through joint for 3C 185 sq.mm cable (Considering length of the cable for one cable drum as 500m) |
| 14 | Supply and laying 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable |
| 15 | 11KV 3 phase outdoor terminating kit to be used with cables - 95 sq.mm. |
| 16 | 11KV 3 phase indoor terminating kit to be used with cables - 95 sq.mm. |
| 17 | 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker confirming to IS & complete with fault passage indicator ( Without Auxilliary PT) |
| 18 | 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches confirming to IS & complete with fault passage indicator ( Without Auxilliary PT) |
| 19 | 4-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with Four Load Break Switches confirming to IS & complete with fault passage indicator ( Without Auxilliary PT) |
| 20 | Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. |
| 21 | GI pipe 150mm, class B (as raiser) (3m*45DTC+ 3m*4 Bay/Interlink + bridge crossing) |
| 22 | Supply & Erection of HDGI flat of size 25mm x 5mm for earthing. |
| 23 | Supply & Laying of RCC Pipe : 100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910 |
| 24 | Bricks class design 75 kg/cm2 (1st class wire cut) for D/C (5600/0.1) |
| 25 | Supply & Erection of HDGI Structural Material (For cable supports,supports clamps, Nuts&Bolts Etc) |
| 26 | Erection Cost |
| 27 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited : SC Trench: S/C (1.1*0.45*13230) & D/C (1.1*0.6* 5600) |
| 28 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. (0.9*0.45*13230) & D/C (0.9*0.6* 5600) |
| 29 | Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autimatic PLC controlled concrete batching plant and cast in a fully automatic \\"vibro-Press\\" machine with a high vibration frequency and hyraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50 mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2/(28 days strength) when tested. (13230/480) & D/C (5600/480*2) |
| 30 | RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)=(13230+5600+5200)/50 |
| 31 | laying 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable open Trench |
| 32 | laying 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable open Trench |
| 33 | 11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm. |
| 34 | Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 185 sqmm XLPE |
| 35 | Supply and erection of straight through joint for 3C 300 sq.mm cable (Considering length of the cable for one cable drum as 500m) |
| 36 | Supply and erection of straight through joint for 3C 185 sq.mm cable (Considering length of the cable for one cable drum as 500m) |
| 37 | Supply and laying 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable |
| 38 | 11KV 3 phase outdoor terminating kit to be used with cables - 95 sq.mm. |
| 39 | 11KV 3 phase indoor terminating kit to be used with cables - 95 sq.mm. |
| 40 | 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker confirming to IS & complete with fault passage indicator ( Without Auxilliary PT) |
| 41 | 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches confirming to IS & complete with fault passage indicator ( Without Auxilliary PT) |
| 42 | 4-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with Four Load Break Switches confirming to IS & complete with fault passage indicator ( Without Auxilliary PT) |
| 43 | Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. |
| 44 | GI pipe 150mm, class B (as raiser) (3m*45DTC+ 3m*4 Bay/Interlink + bridge crossing) |
| 45 | Supply & Erection of HDGI flat of size 25mm x 5mm for earthing. |
| 46 | Supply & Laying of RCC Pipe : 100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910 |
| 47 | Supply & Erection of HDGI Structural Material (For cable supports,supports clamps, Nuts&Bolts Etc) |
| 48 | Ground Penetrating Radar Survey(G.P.R) a) Scanning the roads using ground penetrating radar at every 20 meters interval, b) Idebtification of metallic and non metallic utilities such as water pipelines, o.f.c, gas lines and any other existing utilities along with deph |
| 49 | Civil |
| 50 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a) All kinds of soil |
| 51 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 52 | Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a) All works upto plinth level |
| 53 | Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a) All works upto plinth level |
| 54 | Centering & shuttering including Strutting, Propping & removal of forms for: a) Foundations, Footings, Bases for columns |
| 55 | Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 56 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 57 | Painting three or more coats of aryllic exterior paints of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etccomplete |
| 58 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 59 | Removing of RCC poles 9.00 mtr |
| 60 | Removing of RCC poles 11.00 mtr |
| 61 | Removing of M.S. Rail Pole 90 lb |
| 62 | Removing of 11 KV V-shape 'X' arm with Clamps,etc for RCC poles 9.00 mtr |
| 63 | Removing of 11 KV V-shape 'X' arm with Clamps,etc for RCC poles 11.00 mtr |
| 64 | Removing of 11 KV V-shape 'X' arm with Clamps, Nut & Bolts etc for M.S. Rail Pole 90 lb |
| 65 | Removing of Cut point Channel 1.3 Mtr long with Clamps for RCC poles 9.00 mtr |
| 66 | Removing of Cut point Channel 1.3 Mtr long with Clamps for RCC poles 11.00 mtr |
| 67 | Removing of Cut point Channel 1.3 Mtr long with Clamps for M.S. Rail Pole 90 lb |
| 68 | Removing of Top fitting cross arm for RCC pole/rail pole |
| 69 | Removing of G.O.A.B. Switch 11 KV 400 Amps |
| 70 | Removing of 11 KV Pin Insulators with G.I. Pin |
| 71 | Removing of 11 KV disc insulators 45 KN with Metal parts |
| 72 | Removing of Stay Set Complete for RCC poles 9.00 mtr |
| 73 | Removing of Stay Set Complete for M.S. Rail Pole 90 lb/11Mtr RCC pole |
| 74 | Removing of Suspension Clamps with Eye Hook |
| 75 | Removing of Dead End Clamps with Eye Hook |
| 76 | Removing of HDGI Structural material |
| 77 | Removing of 11KV ABC cable 3CX95 +150 sqmm |
| 78 | Erection of SECTIONALISER 11KV 3PH POLE MOUNTED (with DP and Accessories) |
| 79 | Removing of ACSR conductor 'WEASEL' for Guarding Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender