Coal and Mines Boards / Undertakings / PSU Closing in 12 days TDR #57293863

Tender For Provision Of Foundation And Shed For Ev Charging Station Indira Vihar, Vasant Vihar And Administrative Building Secl, Hq, Bsp (3Rd Call).Nit No : Secl/Bsp/Ta/E Tender/Civil/2026-27/43 Dated 31/08/2026 (Tender Id : 2026_Secl_364589_1)

Issued by Boards / Undertakings / PSU · Bilaspur, Chhattisgarh
Tender Value
31.66 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
12 days left
EMD
39600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bilaspur → Chhattisgarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Foundation And Shed For Ev Charging Station Indira Vihar, Vasant Vihar And Administrative Building Secl, Hq, Bsp (3Rd Call).Nit No : Secl/Bsp/Ta/E Tender/Civil/2026-27/43 Dated 31/08/2026 (Tender Id : 2026_Secl_364589_1)

BOQ

Name of Work:- Provision of foundation and shed for EV charging station Indira Vihar, Vasant Vihar and Administrative Building SECL, HQ, BSP (3rd Call).NIT No : SECL/BSP/TA/e Tender/CIVIL/2026-27/43 dated 31/08/2026 (Tender ID : 2026_SECL_364589_1)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : All kinds of soil.
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement:1½coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
4Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
5Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
6Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. : Size of Tile 600x600 mm
7Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
8Writing work with acrylic sheet and LED light
9Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 125 A, 16 KA,TPMCCB
10Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 250 A, 25 KA,TPMCCB
11Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
12Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
13Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. : Above 35 sq. mm and upto 95 sq. mm
14Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. : Above 95 sq. mm and upto 185 sq. mm
15Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. : 312 X 70 sq. mm (38mm)
16Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. : 312 X 120 sq. mm (45mm)
17Total Impact of GST for the Purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57293863
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 31.66 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name South Eastern Coalfields Limited
Work Description Tender for Provision Of Foundation And Shed For Ev Charging Station Indira Vihar, Vasant Vihar And Administrative Building Secl, Hq, Bsp (3Rd Call).Nit No : Secl/Bsp/Ta/E Tender/Civil/2026-27/43 Dated 31/08/2026 (Tender Id : 2026_Secl_364589_1)
Basic Detail
Tender No SECL/BSP/TA/e Tender/CIVIL/2026-27/43 Date 31/08/2026
Bidding Type Tender
Location
City Bilaspur
State Chhattisgarh
Key Dates
Publish Date 01 Sep 2026
Submission Date 14 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value 31.66 Lakhs
Tender Fee Ref. Documents
EMD 39600
Exemption Not Available
Document List
BOQ_377543.xls
caf1b224-3f44-4142-a33f-44de14485715.html
Tendernotice_1 (22).pdf
Tendernotice_2 (4).pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_377543.xls

html

caf1b224-3f44-4142-a33f-44de14485715.html

pdf

Tendernotice_1 (22).pdf

pdf

Tendernotice_2 (4).pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders