Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57293564

Tender For Renovation Of Superintendent Office Chamber At Howrah District Hospital, Howrah.

Issued by Government Departments · Howrah, West Bengal
Tender Value
2.44 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
0 days left
EMD
5000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Superintendent Office Chamber At Howrah District Hospital, Howrah.

BOQ

Name of Work:- Renovation of Superintendent Office Chamber at Howrah District Hospital, Howrah.
Sl. No. Item Description
1Dismantaling of old and new electrical accessories( Light, Fan, etc.) in existing place to section store as per instruction of E.I.C.
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
3Distn. wiring in 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6 A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. On Board
4Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
62 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire ( 2x6A Plug and circuit )
72 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For 1 X 16A and 1X16A+ 3X6A computer Board )
82 X 4 sq. mm + 1 X 4 sq. mm earth wire [for AC ]
92 X 6 sq. mm + 1 X 6 sq. mm earth wire [ PDB to SPN DB]
10Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (FOR- Lift well 16/20 A switch, power points, SPNDB, TPNDB) 180 x 100 x 60 mm deep
11Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
121.5 sq.mm
132.5 sq.mm
144 sq.mm
156 sq.mm
16Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
17Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A DP
18Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. 6-32 SP
19Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
202 Module (75mmX75mm) ( Split AC Socket)
214 Module (125mmX75mm) ( Split AC Starter & MCB)
2212 Module (200mmX150mm) ( Computer Board )
23Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
245/6 A switch
2515/16 A switch
263 pin 5/6 A socket outlet
276 pin 15/16 A socket outlet
283 pin 25 A socket outlet (Split AC Socket)
29Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
30Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. Double Pole 25 A
31Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
32Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required
33Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body a) 40 Watt
34Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5year OEM warranty. All test report except L80 should be from 3rdparty NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt) Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification
35Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm
36Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
37Supply 450 mm (18 inch) cabin fan on wall by S & F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length. (Compulsorily with Metal Blade & Metal Body) (Make: Orient/ EPC/USHA/ Crompton/ Cinni)
38Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length.
39Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 9\\" (300 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers,temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
40Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
41Add 18% GST (on Item No. 01.00 to 24.00)
42Add 1% CESS (on Item No. 01.00 to 25.00)
43N.B. : 1) Sl. No. 25.00 is variable depending on the total cost of the actual work on which 18 % GST to be calculated during measurement of the work (item No. 1.00 to 24.00) 2) Sl. No. 26 is variable depending on the total cost of the actual work on which 1 % CESS to be calculated during measurement of the work (item No. 1.00 to 25.00) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57293564
AUTHORITY Government Departments
TENDER VALUE 2.44 Lakhs
LAST DATE 16-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Of Superintendent Office Chamber At Howrah District Hospital, Howrah.
Basic Detail
Tender No WBPWD/AE/HESD/e-NIT-27/2026-27
Bidding Type Tender
Location
City Howrah
State West Bengal
Key Dates
Publish Date 01 Sep 2026
Submission Date 16 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 2.44 Lakhs
Tender Fee Ref. Documents
EMD 5000
Exemption Not Available
Document List
bcc41725-5e45-4a8d-85a1-0e9af0e7752a.html
BOQ_5099198.xls
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

bcc41725-5e45-4a8d-85a1-0e9af0e7752a.html

xls

BOQ_5099198.xls

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender