Housing Urban and Rular Development Government Departments Closing in 3 days TDR #57291268

Tender For Construction Of 09 (Nine) Storied Court Building Within The District Judges Court Compound At Bankura In The District Of Bankura-Sitc Of Dg Set

Issued by Government Departments · Bankura, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Sep 2026
3 days left
EMD
1.34 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 09 (Nine) Storied Court Building Within The District Judges Court Compound At Bankura In The District Of Bankura-Sitc Of Dg Set

BOQ

Name of Work:- Construction of 09 (nine) storied court building within the District Judges court compound at Bankura in the district of Bankura-SITC of DG Set
Sl. No. Item Description
1Supply , delivery at site on foundation , testing& commissioning of 500 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-IV+ Compliant Engine & Acoustic Enclosure having following specifications :-
2Engine Make: Cummins /Volvo/ KOEL / Greaves Cotton)
3Engine Type : 4 Stroke Diesel Engine Genset output (kVA/kWe) : 500/ 400
4RPM : 1500
5Gross engine Power (HP) : 604 HP or Higher
6Duty : PRIME
7Aspiration/Cooling : TCAC
8Cylinder /Arrangement : 6 / inline
9Type of Governor : Electronic / Mechanical
10Fuel Tank Capacity : Minimum capacity 740 Ltrs. Or higher
11Fuel Consumption at 75% rated Load with Radiator or Fan : 79Ltr./ Hr. or Less
12Fuel Consumption at 100% rated Load with Radiator or Fan : 103.50 Ltr./ Hr. or Less
13Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better
14Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
15Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicator
16Exhaust Silencer : Hospital grade
17Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
18Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
19Alternator :
20Make : Stamford/Cromton Greaves/Kirloskar/Leroy Somer/Mecc alte
21Rating : 415 V., 3Ph. 50 Hz., 500 KVA, 1500 rpm
22Type : Brushless, self excited and self regulated
23Insulation : Class H
24P.f : 0.8(lag)
25Protection : Screen-protected drip proof with Min.IP-23 degree of protection
26RPM : 1500
27Voltage Regulation (max) : ±1%
28Winding connection : Star with Neutral
29Total Distortion factor : Less than 3%
30Total Harmonic distortion in output waveform : < 5%
31Acoustic Enclosure : The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-IV+ norms.
32Base Frame : Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
33SITC OF AMF Panel (CPRI Approved)
34Supply, Installation Testing & Commissioning of Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 500 KVA DG set having following specification/features.
35i) 2 No.800 A AC1 duty, 4pole power contactor and U/V release etc. [make: L&T / ABB / Legrand / Schneider] ii) 2 Nos. 800 A, 3pole, 50 KA MCCB with microprosser based LSIG protection. [make: L&T / ABB / Legrand / Schneider] iii) In Built By-Pass switch for rated capacity iv) On -delay timer for load change overv) On-delay timer for engine shut offvi) Engine On-Off switch (Push button type)vii) Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine
36viii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.ix) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'. ix) Mode selector for setting the panel on Auto/ Man/ Test Modex) Microprocessor based relay with composite meter for digital display of following.Generator voltage/AC Mains voltage.Generator Current in all phasesFrequencyPower FactorEnergyIndication for alternator supplyRunning time indications number of hours of operation and service intervals, service due indications
37The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
38Construction of suitable size cement concrete foundation of (PCC/RCC) for Installtion of above panel as per manufacturer standard or as per direction of EIC based on site requirement (Bidder should visit the site)
39TERMS & CONDITIONS : (i) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. (ii) Copy of \\"Type Approval Certificate\\" and Certificate of \\"COP\\" must be produced at the time of delivery issued from competent Authority (As per CPCB-IV+). (iii) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/OEM and should be approved by EIC. (iv) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
40(v) The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. (VI) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
41Supply & delivery and pouring of HSD oil for trial run and commissioning of DG set
42Supplying and fixing exhaust gas piping (300MM Diameter ). welded black MS, B class pipe conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50 mm thick wiremesh and aluminium cladding etc., as per requiremement of pollution control norms and required as per direction of Engineer-in-Charge and manufacturer recomendation.
43Fabrication and fixing of MS angle ladder type structure fabricated out of 50mm x 50mm x 6mm angle iron for support of exhaust gas pipe of existing DG set to the required height including grouting in 1:3:6 (1 cement : 3 graded stonenaggregate: 6 coarse sand) cement concrete in ground and support on building, welding, grinding, painting etc. as required. (The measurement shall be made in running meter of MS angle iron only and converted to weight in Kg)
44Supplying & erection of the foundation of a 500 KVA D.G.Set on outdoors having dimensions given below:- a) 300 mm deep (below ground) PCC of size 6050 mm(L) x 2650 mm (W) having a thickness of 200 mm after single brick flat soling on the ground after excavation of the earth.b) 15-inch thick brick wall from the 100 mm deep (below ground) PCC to 600mm (above G.L.), i.e., around the PCC (total Brick Wall Height 700mm) and keeping the central part as follows. c) Filling the hollow portion with a mixture of sand & shifted soil.d) Construct a 6-inch thick RCC slab (M20 grade, 1:1.5:3 mix) on top of the brick foundation with an 8 mm double mesh rod (Make- TATA/SAIL/Jindal) at the top of the brick foundation of size 6050 mm (L) x 2650 mm (W) incl punning, finishing upto the completion the foundation structure and providing foundation bolts, nuts, etc. [ Foundation Size : 6050mm (L) x 2650mm (W) & 600 mm above GL and 300 mm below GL ][Foundation Size: 3150 mm x 1700mm & 600 mm above GL and 300 mm below GL] [N.B: On-site DG set foundation size may be changed as per site condition and manufacturer standard, bidders are requested to visit the site, and final execution may be done as per manufacturer recommendation and approved drawing of EIC]
45Construction of Shed Structure for DG Set with (Make- TATA/JINDAL) Scope colored sheets(Thickness- 0.50 mm) having suitable size tubular Square bar/pipes for structure, size: Length: 7 m, width: 3.5 m & Height from GL: 4 m. (Approx) for proper protection of the DG sets from weather Condition.
46S & Delivery of 200 Ltr. Capacity Container made of heavy guage M.S. Sheet container.
47S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx)
48Supply & provide of 5 mm thick ms conical shape exhaust hood on top of MS EXHAUST pipe extention.
49Supply & laying 2.5 sq. mm. 10 core multi core multistrand PVC insulated flexible Cu cable in uPVC / GI pipe from DG to separate AMF panel. [Gloster/ Polycab/RR Kabel] [Bidder should visit the site]
50Supply & Delivery of 1.1kv grade Aluminium Armoured XLPE insulated PVC sheathed 4 Core 185 Sqmm Cable
51Laying of one No. cable above 185 sqmm in underground trench460mm wide x 760mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per Mtr. including fillingthe space between the bricks and cable and also the trenchwithshifted soil, leveling up and restoring surface duly rammed
52Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables and Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials [4C 185 SQMM]
53Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) forperiodic treatment, incl. providing masonery enclosure on thetop of the earth electrode of overall size 86.36x86.36x46cmdeep (below Ground level) complete with cemented brick work(1:6) of 25 cm width, duly plastered with cement morter(inside) CI hinged inspection cover of size 36.56x35.56cmwith locking arrangement, GI reducer and treatment of soil byusing salt & charcoal or coke for plate electrode
54Supply & Laying 1.1kvgrade Single core 95 Sqmm armoured Copper LT Cable for neutral earthing [RR Cable / Polycab / Havells]
55Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip(4 Mts. long), 20 mm dia x 125 mm long galvanized bolt,double nuts, double washers including finishing both ends bymaking holes etc. and S & F 80 mm dia GI pipe (ISI-Medium)protection (3 Mts. long) to be filled with bitumen partly underthe ground level and partly above ground level to an averagedepth of 3.65 Mts
56Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
57Extra treatment of soil by using salt & charcoal for pipe electrode as to G.S.
58Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil.
59Supplying & fixing earth busbar of 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with bolts, nuts, washers, spacing insulators etc. as required
60Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm cu bar on wall/floor with saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. [5(d ) /G-2] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57291268
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 19-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of 09 (Nine) Storied Court Building Within The District Judges Court Compound At Bankura In The District Of Bankura-Sitc Of Dg Set
Basic Detail
Tender No WBPWD/SE/SWEC/NIQ36/2026-27
Bidding Type Tender
Location
City Bankura
State West Bengal
Key Dates
Publish Date 01 Sep 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.34 Lakhs
Exemption Not Available
Document List
BOQ_5099112.xls
df71ab40-1ed7-439b-9139-f3da092b381d.html
Tendernotice_1 (33).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5099112.xls

html

df71ab40-1ed7-439b-9139-f3da092b381d.html

pdf

Tendernotice_1 (33).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail