Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57290382

Tender For Repair / Replacement / Maintenance Of Street Light Poles / Timers, Lt Cables, Lt Panels, Street Lights And Connected Items In R Line Area And Other Small Units Under Ge K Tee.

Issued by Statutory Bodies & Commissions/Committees · Nagpur, Maharashtra
Tender Value
48.95 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
19 days left
EMD
97900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement / Maintenance Of Street Light Poles / Timers, Lt Cables, Lt Panels, Street Lights And Connected Items In R Line Area And Other Small Units Under Ge K Tee.

BOQ

Name of Work:- REPAIR / REPLACEMENT / MAINT OF STREET LIGHT POLES / TIMERS, LT CABLES, LT PANELS, STREET LIGHTS AND CONNECTED ITEMS IN R LINE AREA AND OTHER SMALL UNITS UNDER GE K TEE.
Sl. No. Item Description
1Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed. Note :- laying of cable route is same as old cable route .
2Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
3Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 185 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
4Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 150 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
5Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
6Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 95 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
7Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 70 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
8Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
9Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
10Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
11Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 Sqmm, 4 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
12Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 Sqmm, 4 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
13Excavation in trenches in soft/loose of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed.
14Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
15Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed .
16Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 120 mm outer diameter and 103 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
17Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 90 mm outer diameter and 75 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
18Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 63 mm outer diameter and 51 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
19Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50 mm outer diameter and 38 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
20Material and labour for testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volt LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.Notes : (i) All T&P and other accessories required for checking and finding of fault in cable shall be provided by the Contractor (ii) Charges/rent of the fault locating mobile machine, operator, engineer, electricians etc shall be deemed to included rate quoted by Contractor. (iii) Checking and finding fault upto 05 places of same route of the cable will be considered as one Job.
21Supply and fix in repair Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 240 Sqmm complete all as specified and directed.Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
22Supply and fix in repair Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified and directed.Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
23Supply and fix in repair Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 21 Sqmm complete all as specified and directed.Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
24S&F in renewal MCCB 63 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 16 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
25S&F in renewal MCCB 100 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 25 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
26S&F in renewal MCCB 125 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 25 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
27S&F in renewal MCCB 160 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
28S&F in renewal MCCB 200 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
29S&F in renewal MCCB 250 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
30S&F in renewal MCCB 320 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
31S&F in renewal MCCB 400 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
32S&F in renewal MCCB 63 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 16 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
33S&F in renewal MCCB 100 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 25 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
34S&F in renewal MCCB 125 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 25 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
35S&F in renewal MCCB 160 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
36S&F in renewal MCCB 200 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
37S&F in renewal MCCB 250 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
38S&F in renewal MCCB 320 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
39S&F in renewal MCCB 400 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 36 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed.
40Supply and fix in repair LED street light luminaires of capacity 60 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection and efficacy minimum 120 Lumen per watt, complete with driver, including three core copper flexible wire of size 0.75 Sqmm for connection from street light fitting to OH line or junction box, fixing accessories and complete all as specified and directed.
41S&F in repair LED driver for 45W to 60W LED street light fittings complete all as specified and as directed.
42Supply and fix in repairs thermoplastic cable entry junction boxes of size 250 x 200 x 105 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 6-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed.
43Supply and fix in repair bracket for street light fittings made out of 32 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size all as specified and as directed.
44M&L for preparing surfaces of electric poles of any type of following sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of aluminium paint completely, alternate layer of yellow and black paint of 150 mm strip at the bottom of pole 1.5 mtr above coping with synthetic enamel paint all as specified and as directed.(a) Height of rail /tubular poles exceeding 7.5 Mtrs upto 11 Mtrs above ground level.
45All as per item No. 44 but height of steel tubular poles 7.5 Mtrs above ground level .
46M&L for preparing surfaces of electric poles of RCC type of any sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of weather proof paint completely and alternate layer of yellow and black synthetic enamelled paint of 150 mm strips at the bottom of pole 1.5 mtr above coping complete all as specified and as directed.
47M&L for preparing surfaces of electric TWO pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly, MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified and as directed.
48All as per item No. 47 but electric Four Pole Structures complete all as specified and as directed.
49M&L for writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and directed.
50M&L for Spray painting to existing LT Panel of any capacity / size / type including mounting angle with two coats of approved colour synthetic enamel paint complete including dusting, cleaning of existing dust before applying synthetic enamel paint and writing feeder name with approved colour synthetic enamel paint complete all as specified and directed.
51Supply, erecting & fixing in replacement of steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etc type 410 SP-31 (9.00 meters long) swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and Numbering of poles as directed including excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of size 600x600x1500mm height upto ground level and using PCC 1:2:4 B-1 for coping with size 450x450x300mm including necessary formwork complete with including taking down old unserviceable pole all as specified and as directed.
52Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including GI wire 4.0 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 32 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (a) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
53Materials and labour as in replacement for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40 mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore ,medium grade & copper lug etc. (f) 40 mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
54Supply and fixing in repair retro reflective boards in shape of rectangle of size 1.0 m x1.4 m made out of 2 mm thick stainless steel both side bounded/pasted with high prismatic (iv) sheet mannufactured by avery dennison or 3 M with desired letters/logos designed as directed the board shall be supplied with and including stainless steel frame made out of 25 mm dia pipe in frame around duly welded with and including stainless steel sheet and stainless steel posts of 38 mm dia and full length of 2.20 m one side and 2.8 m other side complete all as specified and directed. Note :(i) Rate for fixing of boards with PCC 1:2:4 type B2 filling of size 45x45x60 cm to be incl in unit rate. (ii) The board should be written description as direction given by Engineer-in-Charge)
55M&L for Loose filling with aggregates of gauge 20 mm crushed stone back colour suitable for spreading in electrical sub stn after preparation site by removing all type of debris, removing unwanted soil, and spreading lime powder beneath the aggregate all as directed..
56Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 2.5 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and as directed.
57Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 4 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and as directed.
58Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 6 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wirecomplete all as specified and as directed.
59Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 10 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and as directed.
60S&F in replacement 1100 Volts grade Copper conductor, PVC insulated, round sheathed (flexible), industrial cable, 1.5 sqmm 3 core complete all as specified and as directed.
61Supply and fixing in replacement LED flood light 200 watt (Warm white / Cool white) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with taking down old unserviceable flood light complete all as specified and directed.
62Supply and fixing in replacement LED flood light 100 watt (Warm white / Cool white) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with taking down old unserviceable flood light complete all as specified and directed.
63S&F in replacement ONLOAD Changeover switch 400 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed.
64S&F in replacement ONLOAD Changeover switch 320 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed.
65S&F in replacement ONLOAD Changeover switch 200 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed.
66S&F in replacement ONLOAD Changeover switch 100 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed.
67S&F in replacement ONLOAD Changeover switch 63 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed.
68Supply, fixing and testing in replacement of Automatic Street light Timer Switch using combination of NATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable SMC enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 54 protection of capacity 12 KW 3 phase, current range 40 Amps, 4 wire (3 separate power contactor) including all accessories and fixing arrangement all as specified and directed.
69Supply and installation, testing & commissioning self-supporting totally enclosed factory fabricated LT bus Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neoprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, accommodate and consisting of the following items :-(i) Aluminium bus-bar 600 Amps, supported with suitable size Porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB with Adjustable type release, 4 pole, 400Amps, 36 KA, 415 Volts, 50 Hz Adjustable - 01 No.
70Supply and installation, testing & commissioning self-supporting totally enclosed factory fabricated LT bus Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neoprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, accommodate and consisting of the following items :-(i) Aluminium bus-bar 400 Amps, supported with suitable size Porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB with Adjustable type release, 4 pole, 200Amps, 36 KA, 415 Volts, 50 Hz Adjustable - 01 No.
71M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe/GI pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. (NOTE : (i) Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc). (ii) Equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor without any extra cost to the Govt.
72Supplying and fixing in replacement of HDPE Pipe, 90 mm bore (PN 10), suitable for insertion in horizontal boring for protection of cable / croossing of cable, complete all as specified and directed.
73Supply and fixing in replacement of Contactor of type MU-2P series (rating 16 A / 25A / 40A) suitable for existing Automatic Street light Timer Switch complete with taking down old unserviceable Contactor all as specified and as directed.
74Supply and fixing in replacement of Contactor of Freedom series, 3 pole (rating 18 A / 25A / 40A) suitable for existing Automatic Street light Timer Switch complete with taking down old unserviceable Contactor all as specified and as directed.
75Cleaning of sub station area by uprooting all types vegitation, shrubs, weeds, saplings and creepers of unwanted trees complete with the help of spade, axes, crowbars, by chemical spraying and other mechanical means after taking necessary electrical shutdown from concerned incharge of various sub stns of Military Stn Kamptee complete all as specified and as directed.
76Trimming of tree branches touching of Over head Elecctrical Lines upto 2.5 mtr distance from conductors after taking necessary shutdown from concerned incharge all as directed . (Note : Space between two poles will be measured as distance in RM irrespective of nos of conductors).
77Supply and fixing in repair of smart integrated 36 Watt Smart Bright, All in one Solar Street Light including suitable bracket for hanging on existing pole / wall, with Infra Red Remote, with built in mono crystalline panel, Lithium ferro phospate (Lite PO 4) Battery , MPPT charge controller and PIR sensor with colour teperature 6000-6500 K, including nuts, bolts and washers etc, complete all as specified and as directed.
78Supply and fixing of smart integrated 36/40 Watt Smart Bright, All in one Solar Street Light including galvanized steel pole (6 Mtr pole height) with suitable bracket for hanging, with Infra Red Remote, with built in mono crystalline panel, Lithium ferro phospate (Lite PO 4) Battery , MPPT charge controller and PIR sensor with colour teperature 6000-6500 K, including nuts, bolts, washers, excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of suitable size recommended by the manufacturer and using PCC 1:2:4 B-1 for coping with suitable of size including necessary formwork etc, complete all as specified and directed.
79Supply and fixing of smart integrated 30 Watt Smart Bright, All in one Solar Street Light, including suitable hanging bracket, Overcharged & deep discharge protection for battery, MPPT solar charge controller, LiFeP04 lithium Ferro Phosphate battery, maintenance free system, inbuilt BMS system, IP-65, lumen output ≥ 1500 Lm, Colour temp 5700K, Surge protection 5 KV, 50000 burning hrs (min), including nuts, bolts, washers, complete all as specified and directed.
80Supply and fix of Tiranga Led Rope Light Indian Tricolor Strip Light (Orange + White + Green) Colour in Single Strip | Independence Day/Republic Day Rope Light for complete 9 meter pole (SP-31), Plug and Play Waterproof IP65 Strip Light, Complete with driver and all fixing arrangements, complete all as specified and directed.
81Supply and fixing of 3M Scotchlite Reflective Tape of width 50 mm, water proof, for alternate layer of yellow and black / red tape 300 mm from bottom of pole upto 1.5 mtr above, compete all as specified and directed.
82M&L for replacement of PCC coping of poles any type size not less than (0.45x0.45x0.45m) with plain cement concrete (1:3:6) type C1 using 20mm graded coarse stone aggregate, concrete base work, complete all as specified and directed.
83Material and labour for cable route indicator made out of PCC (1:2:4) type B1 of size 60cm x 15cm x 5cm thick grouted in PCC (1:2:4) type B1 pillar fo size 30 cm x 30 x 30 cm in ground with and including necessary foam work and making on board MES LT Cable (1100 Volt) with arrow indicating cable path (marking shall be engraved and colour painted), complete all as specified and directed.
84NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 50,430.00] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57290382
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.95 Lakhs
LAST DATE 22-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement / Maintenance Of Street Light Poles / Timers, Lt Cables, Lt Panels, Street Lights And Connected Items In R Line Area And Other Small Units Under Ge K Tee.
Basic Detail
Tender No 8954/E8
Bidding Type Tender
Location
City Nagpur
State Maharashtra
Key Dates
Publish Date 01 Sep 2026
Submission Date 22 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 48.95 Lakhs
Tender Fee 500
EMD 97900
Exemption Available
Document List
BOQ_882238.xls
e324dbff-104e-4231-8af0-9e49b2779289.html
Tenderdocument8954.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_882238.xls

html

e324dbff-104e-4231-8af0-9e49b2779289.html

pdf

Tenderdocument8954.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail