Educational and Research Institute Government Departments Closing in 8 days TDR #57290285

Tender For Vertical Extension Of Top Four Floors Of Academic Tower-01 ( From G+6 To G+9 Level) At Iit Guwahati C Us

Issued by Government Departments · Kamrup, Assam
Tender Value
45.73 Crore
Estimated cost
Bid Submission
22 Sep 2026
8 days left
EMD
55.73 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Vertical Extension Of Top Four Floors Of Academic Tower-01 ( From G+6 To G+9 Level) At Iit Guwahati C Us

BOQ

Name of Work:- Vertical extension of top four floors of Academic Tower-01 ( from G+6 to G+9 level) at IIT Guwahati C us
Sl. No. Item Description
1Part-A: Building works
2Part-B: Water Supply
3Part-C: Site Development
4Part-D: Fite Fighting
5Part-E: Electrical
6Part-F: VRF AC
7PART A : Building Work
8STEEL REINFOCEMENT
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete 6th Floor level.
10(a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
11Centering and shuttering including strutting,propping etc.&removal of form at all upto above G+5 level.
12(a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
13(b) Columns, Pillars, Piers, Abutments, Posts and Struts
14(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers
15(d) Suspended floors, roofs, landings, balconies and access platform
16(e) Stairs, (excluding landings) except spiral-staircases
17Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering ,finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction o engineer-in-charge.
18(a) All work upto above G+5 level.
19Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
21(a) 1:5:10 (1 cement : 5 coarse sand (zone-ill) derived from natural sources : 10 graded AAC brick bat 40 mm nominal size derived from natural sources)
22(b) 1:2:4 (1 cement : 2 coarse sand (zone-ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
23Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Cement mortar 1:6 (1 cement : 6 coarse sand)
24Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
25Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level
26(a) Cement mortar 1:4 ( 1 cement :4 coarse sand)
27(b) Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
28(c) Extra for Providing and placing in position two numbers 6mm dia. M.S. bars or equivalent hoop iron at every third coarse of all half brick masonry works at all floors, heights, levels.
29(d) Making circular opening for exhaust fan upto 600 mm dia in AAC masonry work by providing proper precast RCC ring of required diameter on edgeat all floors, heights and levels.
30Flooring
31Providing and laying (double charged) vitrified floor tiles of minimum 600mmx600mm sizes (thickness as per manufacturer's specifications) conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with EPOXY tile jointing compounds of matching colours etc., complete at all floors, levels and heights.(rooms,balcony,kitchen)
32(a) in floors including use of specified sizes of spacers
33(b) in Skirting and Risers of steps
34Providing and fixing 18mm thick mirror polish granite slab of approved colour etc. over 20mm cement mortar 1:3 (1 cement : 3 coarse sand) all complete at all floors, heights, levels.
35(a) In Floors, landings,lift lobby,podium, kitchen slabs etc of all sizes etc in approved patterns.(Area of slab above 0.50sqm)
36(b) In kitchen platform, wash basin counter,steps, risers,skirting etc.(Area of slab up to 0.50sqm).
37Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
3825 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand):
39Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
40Internal Plaster
4115 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)
426 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
43Providing and fixing 150mm wide 12 guage 25mmx25mm wire mesh over joints between RCC columns, beams, lintels facias and brick wall with U type MS nails and spread cement mortar 1:3 (1 cement : 3 coarse sand) to fix in position.
44Making of 12mmx25mm groove in exterior plastered surface or RCC projection at all heights, floors and levels. Grooves shall be made by fixing of alluminum channels of required sizes in the required paterns to the walls before plastering and shall be removed after plastering.
45Internal Paint
46Providing and applying white cement based water proof putty of approved brand and manufacturer, over the interior plastered wall surface to prepare the surface even and smooth complete.
47Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with Two or more coats on new work
48Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
49External Plaster
5020 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) Including extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 4.05 m or part thereof.
51(a) 6th. FLOOR
52(b) 7th. FLOOR
53(c) 8th. FLOOR
54(d) 9th. FLOOR
55(e) Above 9th Floor
5618 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
57External Paint
58Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
59(a) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
60Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
61Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
62Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.
63(a) 2 mm thick corrugated (2.5\\" or 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\" ) as specified
64Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge: [Profile E] Fixing with adjustable lugs with split end tail to each jamb
65Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
66(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
67Providing and fixing of Metal fire rated doors as per BS:476 Part- 20 & 22 & IS 3614 part-1 & part-2 for stability, integrity and 20Min thermal insulation. Metal confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI for maximum rating of 2hrs tested with vision panel of 0.15sqm . Individual Test certificates should be available for glass used in vision lites confirming the required fire ratings.Any deviation in specification other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory
68a) Door leaf shall be minimum 47mm thick fully flush GI Metal thickness 1.2MM door with or without vision lite. 47mm thick shutter, comprising of 125mm x 58mm GI 1.6MM frame work, with infill of 48 kg/m3, Rockwool , Powder coated coated with Smoke seal on both sides for insulation. The door frame will be made out of GI Metal with 1.6 Double Rebate section 125 x 58mm and coated with VIPER Fire retardant Primer. The rebate shall be of 19mm x 47 mm in the Door shutter
69b) Both frame and shutter shall be fitted with intumescent Fire seal strips , The shutter fitted with 20x4mm Fire seal and Frame with 2 no. Fire seal of size 10x4mm on all the three sides of the except bottom. The pasting of the ply/veneer/laminate should be done using automatic machine and should be free from any nails or perforations. The following fixtures of Becker FS or apporved make such as 4 Nos SS Ball Bearing Hinges of size 100 x 75 x 3mm per shutter complete with SS Screws ,Mortise Dead Lock ,SS D Type 22mm dia Pull Handle of size 300mm mm Long , door closers,Stainless Steel 304 grade 300mm Long Concealed Flush Bolt with necessary screws as required shall be provided. Anchor fastners shall be of HILTI/ FISHER/ Equvalent of maximum 80mm length.
70c) The rate includes the cost of all the materials, labor & T& P required for proper completion of the item described above. (For payment purpose the area of opening including door frame shall only be measured). The agency shall provide one number additional door alongwith all frame and fittings for getting it tested from the approved agency and in case sample fails, additional sets after improvement shall be provided for testing till the item passes in tests, which shall not be included in measurements for payment.
71Providing and fixing Stainless steel (Grade 304) tower bolts superior quality with necessary SS screws etc. complete:Heavy Duty (Hafele or equivalent)
72(a) 300x10 mm long as per make list.
73Providing and fixing stainless steel sliding bolt with nuts and screws etc. in entrance door shutters including necessary arrangement for fixing in door shutters with additional hook for providing lock in open position of the door complete 250x16mm.
74(a) 300x16mm as per make.
75Providing and fixing Stainless Steel handles of approved quality & make with necessary screws etc all complete with 200 mm. (Godrej Make)
76Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
77Providing and fixing PVC 32mm dia Door buffer in doors including necessary screws etc complete.(Make : Model code 8618 of Godrej)
78Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :
79(a) 100x60x2.50 mm
80Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo embossed on the body, door weight upto 80 kg to 120 kg with double speed adjustment with necessary accessories and screws etc. complete.
81Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.
82(a) Frame size 50 x 100 mm
83Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
84(a) 35 mm thick
85UPVC WINDOW
86Providing, supplying & fixing of 3 Track - 3 Panel Sliding Window with Top Fixed made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron of 120 GSM profiles through out the window. The fixed window having a overall size of 60 x 55 mm with reinforcement of 1 mm thickness and sliding frame with outer frame of 108 x 45mm with sash of size 39 x 58mm with reinforcement of 1.5mm .Glazing bead for fixing of glass shall be of size 20 x 18mm and coextruded with gasket. Composition of profile shall consists a minimum of 6 PHR of TiO₂ for every 100 parts of PVC resin. Windows shall be provided with 20mm DG glass, standard hardware & Flush locking system. Wall thickness of frame & sash shall be 2.2 - 2.4 mm.Cost is inclusive of all taxes, materials, labour, hire charges of manchineries all lead and lifts etc.,complete as per the directions of the Engineer-in charge of work.
87Filling the gap in between UPVC frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod ofapproved quality as per architectural drawings and direction of Engineer-in-charge complete
88Painting with synthetic enamel paint of approved brand and manufacture to give an even shade with Two or more coats on new work
89Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
90(a) In gratings, frames, guard bar, ladder, railings, brackets, gates, grill and similar works
91Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
92(a) With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60)
9325x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.l. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.l. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.l. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
94(a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
95Providing and fixing at all height false ceiling of 6 mm thick (white) finlight PVC foamed sheet of Finolex (or equivalent) with necessary screw of approved quality in 200 mm interval both direction to specified frame work, including providing and fixing of frame work made of special sections power accordance with zinc coating 600 as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 22 mm and 37 mm dia x 40 mm long with 6 mm dia bolts to the angle hanger being fixed with nut and bolts to G.I channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450, including providing fitting and fixing of 19 mm wide melamine polished teakwood liping to each longitudinal directions joints all complete as per drawing and specification and direction of the Engineering in charge
96Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,
97Extra for providing edge moulding to 18mm thick marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite work
98Providing and fixing 18mm thick mirror polish granite slab of approved colour etc. over 20mm cement mortar 1:3 (1 cement : 3 coarse sand) all complete at all floors, heights, levels.
99(a) In Floors, landings,lift lobby,podium, kitchen slabs etc of all sizes etc in approved patterns.(Area of slab above 0.50sqm)
100(b) In lift facade (Area of slab over 0.50sqm).
101Water proofing Treatment at Roof surface.
102(a) Surface Preparation 1. Concrete surface must cleaned with wire brush/grinder to remove loose mortar and must be smooth, uniform, clean and dust free to receive the treatment. Concrete profile should be in the range of CSP 3-4. Preliminary Treatment 2. Any crack, construction joints shall be treated with Polymer modified repair mortar/ SC General purpose grout by proper grooving arrangement [10 x 5 mm] as per manufactures recommendation. 3.Testing by ponding water for 24-72 hours to identify surface defects min. 25 mm-100 mm, (a) First Ponding Test to be on Structural Slab, (b) Second Ponding Test after waterproofing Treatment, (c) Third Ponding Test after Screed laying
103(b) PU Magnum US Application : -
104Supply and installation of roller / brush applied waterproofing built up of Smartcare PU MAGNUM US post application of solvent-based epoxy primer coat Apcoflor Epoxy Primer [250 g/sqm] or equivalent. Waterproof coat of roller applied Smartcare PU MAGNUM US is based on pure elastomeric , polyurethane resin system resist upto 5 bar water head and Medium duty traffic movements etc. with bonding strength > 1.5 Mpa (ASTM D 4541), Elongation >600% (ASTM D412), Tensile Strength – 3-4 MPa(ASTM D412), density 1.25-1.25 kg, Hardness >50 shore A, 35 shore D , Crack bridging capacity > 3 mm [ASTM C 1305] . Overcoating time between each layer should be min. 8-10 Hours and not more than 24 Hours.
105(c) Supplying and laying 150 GSM geotextile over the Horizontal waterproofing layer to receive the protection and slope making screed.
106Coving:
107(d) Making of angle fillets all around the periphery of the wall with polymer modified mortar using SmartCare Repair Mortar.
108Grading roof for water proofing treatment with; Cement concrete 1:2:4 ( 1cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size)
109Providing and mixing water proofing material in cement concrete/cement mortar in proportion as recommended by the manufacturer.
110Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
111(a) For vertical surface two coats @ 0.70 kg per sqm.
112Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 ?45 MPa and adhesive bond strength Class R3 ?1.5 MPa. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
113(a) For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @0.070kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline [email protected] per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040kg to fill the hole)
114Neat cement punning.
115Part-B: Sanitary & Water supply
116Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:(a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
117Providing and fixing white vitreous china pedestal type water closet (European type Single Piece W.C.) with Soft Close Seat Cover, Hinges, Dual Flush Cistern Fitting and Fixing Accessories complete including cutting and making good the walls and floors wherever required :(Make : Model SLS-WHT-6851P180PP of Jaquar or equivalent)
118Providing and fixing white vitreous china wash basin ( oval shape counter top) of size: 605x430x200 mm, including making all connections but excluding the cost of fittings: (Make: Model CNS-WHT-705 of Jaquar or equivalent )
119Providing and fixing glazed vitreous china flat back urinals approx. size 385X325X635 mm with fixing accessories all complete including cutting and making good the walls and floors complete wherever required. (Make: Model URS-WHT-132530 of Jaquar or equivalent )
120Providing and fixing CP brass urinal valve auto closing system-pressmatic wall flange of approved quality with wall flanges complete.-15mmNB,98mm long weighing not less than 75gm.
121Providing and fixing urinal partition with frosted safety glass of 8mm thick of size 900mm(height) x 450 mm(width) corner chamfered fixed in brick wall with stainless steel clips of grade 304 all complete.(Model 1810-US or 1810-UC of Jaquar or equivalant)
122Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
123Providing & fixing C.P. brass push type pillar tap complete including cutting and making good the walls where required. (Make:Model : FLR-5015 of Jaquar or equivalent)
124Providing and fixing towel ring square shape 210 mm long, 159 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of all complete (Make: Model AKP-35721P of Jaquar or Equivalent).
125Providing and fixing C.P. Braas Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange with Seal (Make:FLP-CHR-5083KPM of Jaquar or equivalent)
126C.P. BRASS FITTINGS
127Providing and fixing C.P. Brass Bottle trap including fisher union for wash basin and sink (Make: Model- ALD-CHR-769L300X190 of Jaquar or Equivalent)(a) 32mm dia
128Providing and fixing C.P. brass short body bib cock 2-way with flange ((Make:Model :FLR-5041N of Jaquar or equivalent)) 15mm nominal bore
129Providing and fixing C.P. brass angle valve 15mm dia. for basin mixer and geyser points (Make:Model : FLR-5053N of Jaquar or equivalent)
130Providing & fixing stainless steel soap tray / Shower basket of approved make and design with necessary screws for toilets (Make : Model AKP 35731P of Jaquar Continental)
131Poviding &fixing CP brass Health faucet with 8mm dia 1.2 metre long Flexible Tube with wall hook.Allied range of Jaquar or Equivalent
132Providing and fixing UPVC floor trap with 100mm inlet and 100mm outlet with PVC grating with frame. Providing and fixing UPVC floor trap with 100mm inlet and 100mm outlet with PVC grating with frame.
133Providing, fitting and fixing of Grab Bar Vertical Swing of Stainless steel (Make: WAC-SAP-BG0800CSN of Jaquar or equivalent) for person with disabilities.
134Providing, fitting and fixing of Grab Bar long satin 680 mm (Make: WAC-SAP-BR0600CSNof Jaquar or Equivalent) for person with disabilities.
135WATER SUPPLY
136Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(a) 15 mm nominal outer dia Pipes
137(b) 20 mm nominal outer dia Pipes
138Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
139(a) 32 mm nominal outer dia Pipes
140Providing and fixing brass full way spherical valve with lever wheel IS marked (Zoloto make) 25 mm nominal bore
141Providing and fixing on wall face un-plasticised - Rigid PVC sewer pipes conforming to IS:13592 Type-B including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion single socketed pipes with all accessories as bend, door bend, horn bend etc., complete as directed.
142(a) 110 mm nominal bore
143(b) 150 mm nominal bore
144Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal work – Exposed on wall.
145(a) 40 mm OD
146(b) 50 mm OD
147Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
148External work
149(a) 80 mm
150Providing and fixing rectangular high density GRP Panel water storage tank with cover, conforming to ISI: 14399: 1996 and material conforming to IS: 4249: 1967 for fire retardant of required capacity of suitable size as per manufacture's specifications including fixing and assembling/erecting the tank complete and colour as approved by Engineer-in-Charge all complete as per directions of Engineer in-Charge. The tanks shall be leak proof after installation and having following specifications:-(i) Roof Panels, Side Panels, Bottom Panels, Drain Panels of required size as per manufacture's specifications.(ii)Manhole Panel having dia. 700mm or as per manufacure's specificatoions including lockable lid.
151(iii) Non-Toxic PVC foam sealant gasket sealant tape with high level of resistance to ageing and superior recovery from compression from SAINT GOBAIN or equivalent. (iv) Fasteners for the panel joints shall be of M.S bolts nuts of grade M12 X 40mm & M12 X 45mm.(v) External reinforcement shall be of C Channel at every 1-meter of steel with anticorrosive paint and shall be tied with top external tie rods all complete as per manufacture's specifications. (vi) Internal roof supports should be of FRP 5mm thick hollow square section or as per manufacture's specifications.vii) The tank shall be provided with Air-vent of dia 100mm with mosquito proof mesh. (viii) Water level indicator with clear tube type and brass nozzle etc shall also be provided.
152(ix) The tank shall also be fitted with Internal FRP ladder with wall mounting arrangement inside.(x) External G.I. or other suiitable material ladder with complete fixing arrangement shall be provided for access from outside. (xi) The tank shall be provided with Complete fixing of Inlet/ Outlet/ overflow/drain with G.I Flange type with 9 inch long nipple.The rate shall include making necessary holes for inlet, outlet & over flow pipes etc all complete and nothing extra shall be paid on such account. (The base support i/c fittings & fixures for tank shall be paid separately).
153Part-C: Site development work
154Earth work in filling for site preparation with approved quality of earth including filling the portion within plinth area upto the formation level, peripheral apron & drains etc. complete upto formation level. in layers not exceeding 20 cm in depth including watering, ramming, consolidating to the acceptable density and dressing complete as directed including obtaining earth and removal of top vegetation, dressing the surface upto proper grade and slope. (The rate shall be inclusive of providing earth including all leads and lifts, payment of land compensation for obtaining earth, payment of royalty and taxes etc.(The payment will be made in profile measurement)
155(a) With the earth from outside the campus
156Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
157(a) All kinds of soil.
158Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
159(a) 1:4:8 (1 Cement : 4 coarse sand (zone-ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
160Centering and shuttering including strutting, propping etc. and removal of form for
161(a) Foundations, footings, bases of columns, etc. for mass concrete
162(b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
163(c) Suspended floors, roofs, landings, balconies and access platform
164Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
165Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
166(a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
167Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
168(a) Cement mortar 1:6 (1 cement: 6 coarse sand))
16915 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :
170(a) 1:4 (1 cement: 4 fine sand)
171Providing and laying factory made FRP Gratings as per direction of Engineer in Charge (Grating size 1220 mmx600 mmx38 mm, mess size 38 mmx38 mm)
172ROAD WORK
173Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal ofsurplus earth lead upto 50 metres.
174Supplying and stacking of graded stone aggregate at site of size range.
175(a) 90 mm to 45 mm
176(b) 63 mm to 45 mm
177(c) 53 mm to 22.4 mm
178Supplying and stacking of stone screenings/ chippings at site.
179(a) Stone screening 13.2 mm nominal size (Type A)
180(b) Stone screening 11.2 mm nominal size (Type B)
181Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
182Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
183(a) 80mm thick
184(b) 60mm thick
185Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)
186Part-D: Fire Fighting works
187Sub-head -I Hydrants & Spinklers
188Supplying and Fixing Single Headed Internal Hydrant Valve oblique pattern with intantanneous S S coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS: 5290 (Type A), with 80 mm dia flanged inlet,with ABS cap and chain complete with all accessroies etc. as required. Make : GETECH/NEWAGE/SAFEX
189Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Gun Metal 3 mm dia ISI Marked male & female couplings (IS:903) bound & riveted to hose pipes with copper rivets and copper wire complete as reqd.( MAKE: NIRMAL RUBBER/NEWAGE/BRG)
190Supplying and fixing 63mm dia, S S Branch Pipe with 16/20mm dia copper nozzle confirming to IS : 903 suitable for instantaneous connection, interconnect hose pipe, coupling as required. (Type A) as required. MAKE:GETECH/NEWAGE/SAFEX
191Supplying and Fixing First Aid Hose Reel, wall mounting swinging type complete with drum & bracket of MS construction, spray painted in Post office Red, confirming to IS 884/1995 with upto date amendments, complete with the following as required. 36 Meter long 20 mm dia water hose Thermoplastic (Textile reinforced) Type - 2 as per IS : 12585 20 mm dia gun metal globe valve & nozzle. Drum and brackets for fixing the quimpments on wall. Connection from riser with stop valve (gun metal) & M.S. PipeMAKE : GETECH/NEWAGE/SAFEX
192Providing, Fixing, Testing and Commissioning of Sprinkler Installation Control Valve of Cast iron body and brass / bronze working parts comprising of water motor, alarm, bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 150 mm dia, as required.MAKE:GETECH/NEWAGE/SAFEX
193Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature. MAKE:GETECH/NEWAGE/SAFEX
194Pendent / Upright type, 68 C, Chrome plated
195Side wall 68 C, Chrome plated
196Sub Head - II Piping, Valves and Accessories
197Providing, Laying, Testing and Commissioning of 'B' class ( Medium ) MS pipe on surface confirming to IS 3589 and 1239 including cutting and welding with fittings like elbows, reducer, hanger, tees, flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall / ceiling with suitable clamps and painting with two coats of synthetic enamel paint after primer coat of required shade, cutting hole and chase in brick wall / RCC slab and making good the same etc. complete as required.MAKE: TATA,JINDAL,NEZONE
198200 mm dia
199150 mm dia
200100 mm dia
20180 mm dia
20265 mm dia
20350 mm dia
20440 mm dia
20532 mm dia
20625mm dia
207Supplying, Installation, Testing and Commissioning of cast iron sluice valves of PN 1.6 rating flanged at both ends of following sizes complete with rubber insertion, nuts, bolts and washers etc. as required.MAKE: KARTAR,AUDCO,SANT
208200 mm dia
209150 mm dia
210100 mm dia
21180 mm dia
212Supplying, Installation, Testing and Commissioning of butterfly valves of PN 1.6 rating of following sizes with nitrile seat and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects as required. MAKE: KARTAR,AUDCO,SANT
213150 mm dia
214100 mm dia
21580mm dia
21665 mm dia
21750 mm dia
218Providing, Installation, Testing and Commissioning of double flanged cast iron Non-Return Valve, PN 1.6 of following sizes confirming to IS : 5312 complete with rubber gasket, Gl bolts, nuts, washers etc. as required.MAKE: KARTAR,AUDCO,SANT
219200 mm dia
220150 mm dia
22180 mm dia
222Providing, Installation, Testing and Commissioning of forged brass / Gun Metal Ball Valves with brass body chrome plated of following sizes as required.MAKE: KARTAR,AUDCO,SANT
22350mm dia
224Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having caliberation of 0 -16 Kg / cm2 MAKE:H.GURU/FEBEC
225Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926MAKE:GETECH/NEWAGE/SAFEX
226Constructing masonary chamber for external sluice valve of 90 x 90 x 100 cm, inside finish with II class designation brick work in cement mortar 1:5 (1 cement : 5 fine sand) for sluice valve, with C.I. main hole cover & frame of 600 mm dia. and RCC top slab ( 1:2:4 mix, 1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cementcomplete as required.
227TERRACE PUMPS:
228Supply, Erection, Testing & commissioning of Terrace Pump Horizontal end section single stage centrifugal type pump complete with bronze impeller, mechanical seal capable of delivering 27 (M3/Hr) against a total head of 30 metres, induction motor suitable for 415V, Min 5.5KW with 2900 RPM, TEFC type conforming to IP: 55, flexible coupling, coupling guard. Common bedplate fabricated from mild steel channel, vibration pads, isolation arrangement & RCC foundation. MAKE:KIRLORKAR OR EQUIV.
229Supply, Erection, Testing & commissioning of Air Vessel made of 10 mm M.S. Sheet size 450 x 2000 mm including supply & fixing of Gun metal 32 mm dia Air release Valve, 32 mm dia Gun Metal gate valve, 40 mm dia gun metal gate valve including 2Mts of M.S 40 mm dia G. I (Heavy pipe for drainage and 1 no. 65 mm dia Butterfly valve with all necessary accessories as per IS 2825MAKE:GETECH / SELF FEBRICATED.
230PIPING ABOVE GROUND FOR EASY MAINTENANCE
231Supply, Erection, Testing & commissioning of M.S pipe (Medium) ISI marked 1239-part-1 and ISI : 3589 including cutting, welding/threading with accessories like tees, elbows, flanged joints, reducers, rubber gaskets, nuts & bolts including fixing the pipe with suitable clamps/bracket, complete as required including painting of one coat of red oxide & 2 coats of P.O. red paintMAKE: TATA,JINDAL,NEZONE.
23280 mm dia
233150 mm dia
234Supply, Erection, Testing & commissioning of Single headed hydrant S S valves conforming to ISI: 5290 with flanged inlet with 63 mm female instantaneous of gun metal coupling with blank cap & chain, nuts, bolts, washers & 5mm thick rubber gasket etc. MAKE:GETECH/NEWAGE/SAFEX
235Supply, Erection, Testing & commissioning of 63 mm dia, 15 M long RRLhose pipe conforming to ISI-636 type A Mark fire hose pipe conforming to IS 901 mark with S S male & female coupling wire wound with the pipe MAKE:GETECH/NEWAGE/SAFEX
236Supply, Erection, Testing & commissioning of S Sshort branch pipes conforming to ISI spec 903 with 16 mm dia nozzle.MAKE:GETECH/NEWAGE/SAFEX
237Supply & Erection of M.S.Fire Hose Box of size 900 x 600x 450 mm approx.) fabricated from 16 SWG. M.S. Sheet of fully welded construction with hinge front door with locking arrangement & partially glazed with 5 mm thick glass powder coated fire red finish paint with Fire Hose Box written on the front side of the glass for internal hydrants to house 2 nos. hose pipes, 1 no. Branch pipe, 1 no. Hose reel & Landing valve 1 No. MAKE:GETECH/NEWAGE/SAFEX
238TERRACE PUMP PANEL to start the Terrace Pump Automaic
239Supply of fire buckets Set of four nos. with MS stand with sand etc. as required.
240Supply, Installation, Fixing of ABC stored Pressure Fire Extinguisher with built – In Pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle as per IS:15683 with ISI mark.(6 kg capacity)BRAND : GETECH / MINIMAX/ SAFEX
241Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 15683 with ISI Mark.(4.5 LITERS) BRAND: GETECH /MINIMAX / SAFEX
242Manual Call Point & Hooter each floor area. Make:Agni Suraksha
24312 Zone Panel for Manual Call Box & Hooter to identify the
244Exit Board Auto Glow type for easy evcuation floor wise.
245Providing & fixing angle iron (40mm x 40mm x 5mm) door frame and M.S sheet (2mm thick) sum glass shutter of size 2.1 mtr. X 1.2 mtr. (N.S) with 25 mm x 3 mm angleframe all around & stiffenced in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamle paint i/c sign writing on glass at internal hydrant including providing & fixing M.S. Sheet 2 mm thick on remaing portion above door to close opening i/c painting etc. as required.
246PART-A
247Point Wiring and Submain wiring
248Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
249Group B
250Group C
251Wiring for circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2522 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
2532 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
2542 x 4 sq.mm + 1 x 4 sq.mm earth wire
2552 x 6 sq.mm + 1 x 6 sq.mm earth wire
2562x10 Sq mm +1x 10 Sq mm earth wire
2574X10 Sq mm + 2X6 sq mm earth wire
2584X16 Sq mm + 2X6 sq mm earth wire
259Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
260Supplying and fixing following modular switch/ socket on the existing modular plate & switch box inclding connections but excluding modular plate etc. as required.
2615/6 A Switch
26215/16 A Switch
263Supplying and fixing following modular switch/ socket on the existing modular plate & switch box inclding connections but excluding modular plate etc. as required.
2643 pin 5/6 A socket outlet
2656 pin 15/16 A socket outlet
266supplying and fixing following size / modules, GI box alongwith modular base and cover plate for modular switches in recess etc. as required.
2671 or 2 Module
2683 Module
2694 Module
2706 Module
2718 Module
27212 Module
273Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
274Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
275Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
276100A 30KA FP
277125A 36KA FP
278200A 36KA FP
279Installation ,testing and commissioing of pre wired fluorescent fittings/compact fluorescent fitting of all complete with all the accessories and tube /lamp etc etc directly on ceiling /wall including connection with 1.5sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required.
280Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
281Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2828 way , double door
28312 way , double door
28416 way , double door
285Supplying and fixing following way, horizontal type three pole and neutral sheet steel MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2866 way (4 + 18), Double door
2878 way (4 + 24), Double door
288Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2898 way (4 + 24), Double door
290Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.
291Single pole
292Single pole and neutral
293Double pole
294Triple pole
295Triple pole and neutral
296Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
297100 A
298Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
299Upto 35 sq. mm (clamped with 1mm thick saddle)
300Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
301Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3023½ C X 35 sq. mm
3033½ C X 95 sq. mm
3044C X 10 sq. mm
305Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required
306100 mm width X 50 mm depth X 1.6 mm Thickness.
307300 mm width X 62.5 mm depth X 2.0 mm Thickness.
308450 mm width X 62.5 mm depth X 2.0 mm Thickness.
309600 mm width X 75 mm depth X 2.0 mm Thickness.
310Bus Trucking and Rising Main
311Supplying, installation on wall or suspension on ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq.cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
312315 A, Isc = 25kA for 1 second
313Supplying, installation, testing & commissioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required
314125 A, Isc= 15kA for 1 sec
315200 A, Isc= 25kA for 1 sec
31663 A, TPN, 2 way, distribution tap off box with ISI marked HRC fuses for rising mains
317Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required
318125 A, 16 KA,TPMCCB
319200 A, 16 KA,TPMCCB
320Design fabrication, Supply installation testing and commissioingoutdoor type free standing, dust and vermin proof, fabrication 2mm CRC sheet with powder coating and providing TPN 125A aluminilum busbar @ wiring etc as per following-
321As Incomer i) 125A 4P 25KA MCCB=1 no ii) Spresder Link for 125A 4P MCCB( Set of 8 Pcs)=1No iv) Digital Multifunction meter ( V,A,PF,KW,KWH) =1 No v) LED Indicator Switch= 3 Nos vi) CT 250/5A CI-1 Tape Wounded=3 Nos vii) 6A SP MCB =3 Nos As Outgoing i) 40 A DP 10KA MCB=5 No
322Design fabrication, Supply installation testing and commissioingoutdoor type free standing, dust and vermin proof, fabrication 2mm CRC sheet with powder coating and providing TPN 63A aluminilum busbar @ wiring etc as per following-
323As Incomer i) 63A 4P 25KA MCCB=1 no ii) Spresder Link for 63A 4P MCCB( Set of 8 Pcs)=1No iv) Digital Multifunction meter ( V,A,PF,KW,KWH) =1 No v) LED Indicator Switch= 3 Nos vi) CT 250/5A CI-1 Tape Wounded=3 Nos vii) 6A SP MCB =3 Nos As Outgoing i) 40 A DP 10KA MCB=1 No ii) 25A DP 10KA MCB C =4
324Design fabrication, Supply installation testing and commissioingoutdoor type free standing, dust and vermin proof, fabrication 2mm CRC sheet with powder coating and providing TPN 200A aluminilum busbar @ wiring etc as per following-
325As Incomer i) 200A 4P 25KA MCCB=1 no ii) Spresder Link for 200A 4P MCCB( Set of 8 Pcs)=1No iv) Digital Multifunction meter ( V,A,PF,KW,KWH) =1 No v) LED Indicator Switch= 3 Nos vi) CT 250/5A CI-1 Tape Wounded=3 Nos vii) 6A SP MCB =3 Nos As Outgoing i) 63 A4P 10KA MCB=1 No ii) 63A DP 10KA MCB C =4
326Eathing and Lightning Conductor
327Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
328Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
329Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required
330Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
331Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
332Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
333Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kv grade of following size direct in ground including excavation, and cushioning, protective covering and refilling the trench etc. as required.
334Laying of cable ( above 185 sq. mm and upto400 sq. mm )
335Supply of 1.1KV grade PVC/XLPE insulated Unarmored Aluminium underground Cable ( Approved Make-Havell,KEI,Polycab,RPG,NICCO,Finolex,CCI,Incab)
33610 sqmm 4 Core
33725 sqmm 4 Core
33835 sqmm 3.5 C
33995 sqmm 3.5 C
340300 sqmm 3.5C
341Supply, installation testing and commissioning of lifts of maximum rated load 13 passenger, speed 1.5mps of triplex system travelleing for G +9 floors of travel height. Hair line stainlesssteel venyle floor finish, centre opening automatic door of fire retardent capacity not less than 2hours without machine room, gear less system inclusive of all accessories, gadgets, emergency light car operating panel indicator door close and open button alarms, colour LCD display, emergency phone, handicapped COP, braille push buttons, star light ceiling finish inside the car, PVC floor finish, and all other devices complying to fire escape, emergency evacuation control, NBC etc. complete in all respect inclusive of taxes duties etc.
342Net Work and telephone Connectivity
343Inter Building Racks Connectivity - Fibre
344Supply, Installation, Testing and Commissioning of SM OS2 6 Core Fiber Cable as per technical specification.
345Supply, Installation, Testing and Commissioning of SM OS2 Fiber Patch Cord LC -LC 3M as per technical specification.
346Patch Cable & IO Box - CAT-6
347Supply, Installation, Testing and Commissioning 1 mtr CAT 6 Patch Cord as per technical specification.
348Supply, Installation, Testing and Commissioning 2 mtr CAT 6 Patch Cord as per technical specification.
349Category 6 - I/O Jacks with Face Plate - Multi Color - inc. Compatible Metal Back Box
350Intra Building End Points - CAT-6
351Supply, Installation, Testing and Commissioning of CAT 6 Cable as per technical specification. Drum of 305 Meter
352Passive Rack Mounted Accessories
353Supply, Installation, Testing and Commissioning Patch Panel as per technical specification.
354Supply, Installation, Testing and Commissioning of 12 Port Fully Loaded Fiber LIU (LC) as per technical specification.
355Supply, Installation, Testing and Commissioning of 24 Port Fully Loaded Fiber LIU (LC) as per technical specification.
356Rack and Rack Accessories
357Supply, Installation, Testing & Commissioning of 15U RACK IT INDUSTRY STANDARD RACK with all Standard Accessories as per technical specification.
358Supply, Installation, Testing & Commissioning of 42U RACK IT INDUSTRY STANDARD RACK with all Standard Accessories as per technical specification.
359Phones
360Basic Caller ID Phone
361Back-End
362EPABX Server - Academic Block - 30 SIP Trunk - 500 SIP Lines
363Cables and Accessories
364Backend Accessories - Couplers - MDF Box - Others
365RJ 11/ 45 Gang Box
3662 Pair PVC Cable 90mtr per roll
36720 Pair PVC Cable 90mtr per roll
368Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
369Light & Fixtures
370Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 36Watt
371LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR(Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim
37212-15 watts
373Supply of 20W LED light TMC set ( Philips/Havells/CG/Bajaj)
374Supply of five star rated 450 mm Sweep wall bracket fan ( make havells/CG/Orient/Berilia)
375Supply of five star rated Exhaust fan,300 mm Heavy duty Make -havells/Crompton/
376Supply of wall decortative bracketlight with all accessories as per site requirement make decon or equivalent
377Fire Alarm System
378Supply installation testing and commissoing of micro processor based intelligent addressable main fire alarm panel central procssing unit with the following loop modules and capable of supporting not less than 240 device ( including detector) and minimum 120 detector per loop and loop earth up to 2 km network commusnication card minimum 320character graphics/LCD display with louch screen or other keypad and minimum 4000 events history log in the non volatile memopory ( EPROM) power supply unit ( 230 ± 5% V 50 Hz) 48 hours back up with 24 volt sealed mintenance free battery with automatics charger. The panel shall have facilities to integration with analog / didgital voice evacuation system ( Which is part of the schedule of the work under SH:PA system) and shall be complete with all accesories. The Panel shall be compitable for IBMS system with open proticol BACne/ nodbus over IP complete as per Speccification
37910 loop panel
380Supply , Installation testing & Commissioing of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc as required
381Supplying installation testing and commissioing of smoke detector with builtin LED and mounting base complete with all connection as required
382Supplying installation testing & commissioing fire alarm sounder with facilities to make annoucement mounted in ABS box with hinged cover plate & suitable operation with amplifer i/c line matching transformer etc as required
3832c x 1.5 sqmm Fire survival armoured cable
384Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
385Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
386OUTDOOR UNIT
387Supply, installation, testing & commissioning of fully factory assembled Variable Refrigerant Volume type multi unit air-conditioning system inverter type complete with indoor and outdoor units with individual controller for cooling only operations.SITC of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units, having all hermetically sealed inverter type Scroll Compressor(s) as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A or R407C , iii) Protective coated fins iv) Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquid, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point .All Inverter Scroll Compressor(s) with variable refrigeration evaporating temperature enabled feature in outdoor unit capable of inverter control with 6 pole compressor motor.The inverter compressor should be capable of changing the speed in accordance to the variation in cooling or heating load requirement, back pressure control mechanism for efficient operation in low-load condition.The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss. The unit shall be suitable to work on 400V+/-10%, 3 Phase, 50Hz AC power supply.The outdoor units shall be suitable to operate within an ambient temperature range of 5 Deg C to 43 Deg C in cooling mode; & -20 Deg C to 15 Deg C in heating mode.The outdoor unit should be capable of automatic refrigerant charge function. The heat exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The cost should be inclusive of Lifting, Shifting & Positioning of Outdoor Units to the installation platform
388Outdoor condensing Unit ( 68 HP) Nominal capacity
389Outdoor condensing Unit ( 60 HP) Nominal capacity
390Outdoor condensing Unit ( 54 HP) Nominal capacity
391Outdoor condensing Unit ( 34 HP) Nominal capacity
392Indoor Units- All with cordless remote
393Supply, installation, testing & commissioning of variable refrigerant volume modular type indoor units comprising of all accessories as per the specifications. The indoor units shall be suitable to work on cooling as well as heating mode.The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Indoor units shall be complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable filter with Cordred /cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. SITC of Indoor VRV Ceilling Mounted High Static Flow Type Duct Unit with Independent Vane Control & varibale air flow as per following nominal capacities complete withi) Expansion and mixing arrangementsii) Power Supply interconnectionsiii) Controlling interconectionsiv) Piping interconnectionsv) Supending accessoriesvi) Insulated Drain pipe linevii) Receiver Kit(Sensor) of Duct AC
3944-Way Cassette Type Units with cordless remote
3954 way Cassette Type Units (4.6 TR)(nominal capacity)
3964 way Cassette Type Units (4.0 TR)(nominal capacity)
3974 way Cassette Type Units (3.2 TR)(nominal capacity)
3984 way Cassette Type Units (2.5 TR)(nominal capacity)
3994 way Cassette Type Units (2.0 TR)(nominal capacity)
400Supply and fixing of Interconnecting 'Y' Joints i.e. Refnet Joints/ Header with Y-joints and headers
401Refrigerant Piping (VRV System)
402Supply, Installation ,testing and commissioning of soft/hard drawn copper refrigerant piping for VRV/VRFsystem with thickness of wall shall be 20G/ 22G(0.7 to 1 mm) complete with fittings ,with suitable adjustable ring type hangers upports,jointing /brazing including accessories, insulated with Closed Cell Elastomeric Nitrile Rubber foam with factory laminated GC cloth coating for mechanical and UV protection, Fire retardant class ‘O‘ with proper uV protection layer on the surface of the insulation. Nitrile rubber insulation exposed to outdoor conditions shall be provided with cladding of \\"Armachek Silver 350 by Armacell\\" or equivalent 3-layer composite film with shining aluminium like metallic appearance, with UV protection and polymer backing for mechanical protection.
40341.23 mm dia(OD) -1.43 mm thick with 19mm thick insulation
40434.9 mm dia(OD) -1.21 mm thick with 19mm thick insulation
40528.58mm dia(OD) - 1.0 mm thick with 19mm thick insulation
40622.2 mm dia(OD) - 0.8 mm thick with 19mm thick insulation
40719.1 mm dia(OD) - 0.8 mm thick with 19mm thick insulation
40815.86 mm dia(OD) - 0.8 mm thick with 13mm thick insulation
40912.7 mm dia(OD) -0.8 mm thick with 13mm thick insulation
4109.5 mm dia(OD) - 0.8 mm thick with 13mm thick insulation
4116.4 mm dia(OD) - 0.8 mm thick with 13mm thick insulation
412Drain Piping
413Supply,installation,testing and commissioning of drain piping shall be made out of rigid PVC pipes of 10 Kg/cm2 class. . The piping shall be insulated with 9mm thick closed cell nitrile rubber sleeves.
41465 mm dia
41550 mm dia
41640 mm dia
41732 mm dia.
418Communication and Transmission Cable
419Supply,installation,testing and commissioning of 2C x 1 sqmm copper conducter flexible cable for communication beetween VRV/VRF IDU and ODU in PVC conduit as per specifications ( for transmission and remotes)
420Supply,installation,testing and commissioning of Inline fan complete with motor, blower, mounting arrangement louvers, power and control wiring etc. of below capacity. The Inline fan shall be suitable for 230V, 1Ph., 50Hz AC power supply. The static pressure will be calcualted by HVAC contrctor on basis of final duct layout.
421800 CFM, 15 mm wc SP for Toilet exhaust
422450 CFM, 25 mm wc SP for fresh air
423400 CFM, 25 mm wc SP for fresh air
424350 CFM, 25 mm wc SP for fresh air
425Supply,installation,testing and commissioning of fire retardant non porous double layer flexible connection as per drawings and specifications.
426Auminium Powder Coated Rain Protection Louver
427Supply Installation, testing and commissioning of rain protection louver with Bird screen for fresh/exhaust air or exhaust air complete with extruded aluminium constuction with powder coated finish complete in all respect as per drawings.
428Collar Damper
429Supply Installation, testing and commissioning of Volume Control Damper of 22G GI constuction and complete in all respect as per drawings.
430Supply Installation, testing and commissioning of Toilet exhaust grill - 100 mm dia
431Supply Installation, testing and commissioning of flexible duct.
432100 mm dia
433Underdeck Insulation
434Supply and Fixing of thermal insulation with following thickness Class-O Nitrile sheet (density 40-60kg/cum) for underdeck insulation using low VOC adhesive and screwing with GI washer.
43532 mm thick for Nitrile Insulation for underdeck insulation .
436Duct/Grilles/Diffusers
437G.I Rectangular Ducts as per “SMACNA” standards & specifictions
438Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support etc. as per approved drawing and specifications of following sheet thickness complete as required. The steel sheets shall be hot dip galvanized with coating of minimum 120 grams per square meter (GSM) of Zinc.
439thickness 0.63 mm sheet
440Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
441Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with collar control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required
442Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Return Air Grills without collar control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required All these grilles shall be single louvered similar to supply air registers.
443Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. Cost shall include plenum box of diffuser with 9 mm insulation.
444Supplying, Fixing, installation, testing and commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. Cost shall include plenum box of diffuser with 9 mm insulation.
445Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick nitrile insulation having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57290285
AUTHORITY Government Departments
TENDER VALUE 45.73 Crore
LAST DATE 22-09-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Vertical Extension Of Top Four Floors Of Academic Tower-01 ( From G+6 To G+9 Level) At Iit Guwahati C Us
Basic Detail
Tender No IITG/IPM/NIT/C/2026-27/57
Bidding Type Tender
Location
City Kamrup
State Assam
Key Dates
Publish Date 01 Sep 2026
Submission Date 22 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 45.73 Crore
Tender Fee 5000
EMD 55.73 Lakhs
Exemption Not Available
Document List
BOQ_971355.xls
d210e0ff-3e68-4ce9-81ae-ed82985c64c9.html
Drawings.pdf
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_971355.xls

html

d210e0ff-3e68-4ce9-81ae-ed82985c64c9.html

pdf

Drawings.pdf

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders