Tender For Valve Operation And Leakage Removal In Internal Distribution Pipelines Of Rwss Originating From P.S.-5 (Loharwada) Head Works Under Sub Division Nasirabad Ajmer
Tender Value
8.76 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
4 days left
EMD
17520
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ajmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Valve Operation And Leakage Removal In Internal Distribution Pipelines Of Rwss Originating From P.S.-5 (Loharwada) Head Works Under Sub Division Nasirabad Ajmer
BOQ
| Sl. No. | Item Description |
| 1 | Daily/ periodical operation of valves at supply times for specified by department per sluice valve per month. (Valve rod and cap to be arranged by contractor) |
| 2 | 80-300mm |
| 3 | Cleaning of Over Head Service Reservoir ( OHSR ) of below mentioned capacity including removal of all silt from reservoir, scrapping of walls, disinfection of reservoir after cleaning and disposal of silt up to 1.00 Km lead and painting the date of cleaning on the reservoir. |
| 4 | 50 to 100 KL |
| 5 | 101 to 200 KL |
| 6 | Cleaning of Ground water reservoir ( GLR's) of below mentioned capacity including removal of all silt from reservoir, scrapping of wall, disinfection of reservoir after cleaning and disposal of silt up to 1.00 Km lead and painting the date of cleaning on the reservoir. |
| 7 | 31 to 50 Kl |
| 8 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) |
| 9 | In all type Soil AC/PVC/HDPE pipe |
| 10 | 50/63/75mm |
| 11 | 80/90mm |
| 12 | 100/110mm |
| 13 | 125/140mm |
| 14 | 150/160/180mm |
| 15 | For B.T. Road |
| 16 | 50/63/75mm |
| 17 | 80/90mm |
| 18 | 100/110mm |
| 19 | 125/140mm |
| 20 | 150/160/180mm |
| 21 | For C.C. Road |
| 22 | 50/63/75mm |
| 23 | 80/90mm |
| 24 | 100/110mm |
| 25 | 125/140mm |
| 26 | 150/160/180mm |
| 27 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) |
| 28 | In all type Soil |
| 29 | 100mm |
| 30 | 125mm |
| 31 | 150mm |
| 32 | For B.T. Road |
| 33 | 100mm |
| 34 | 125mm |
| 35 | 150mm |
| 36 | For C.C. Road |
| 37 | 100mm |
| 38 | 125mm |
| 39 | 150mm |
| 40 | Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost) |
| 41 | In all type Soil |
| 42 | 50/63/75mm |
| 43 | 80/90mm |
| 44 | 100/110mm |
| 45 | 125/140mm |
| 46 | 150/160/180mm |
| 47 | For B.T. Road |
| 48 | 50/63/75mm |
| 49 | 80/90mm |
| 50 | 100/110mm |
| 51 | 125/140mm |
| 52 | 150/160/180mm |
| 53 | For C.C. Road |
| 54 | 50/63/75mm |
| 55 | 80/90mm |
| 56 | 100/110mm |
| 57 | 125/140mm |
| 58 | 150/160/180mm |
| 59 | Restoration of bitumen road by patch work of WBM using crushed / broken aggregate as per the standard specification and consolidation with hand rammer spreading and consolidation of binding material , cleaning of surface of WBM and providing of seal & tack coat as per site condition by using ready cold mix up to the satisfaction of engineer in charge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job. |
| 60 | Restoration of cement concrete road including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compacting cement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction of engineer incharge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job. |
| 61 | Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit. |
| 62 | In all type Soil |
| 63 | 90/80 mm |
| 64 | 110/100 mm |
| 65 | For C.C. Road |
| 66 | 90/80 mm |
| 67 | 110/100 mm |
| 68 | Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit. |
| 69 | In all type Soil |
| 70 | 100 mm |
| 71 | 150 mm |
| 72 | For C.C. Road |
| 73 | 100 mm |
| 74 | 150 mm |
| 75 | Disconnection of water connection or Illigal connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree refill the pit from excavated sand by ramming it & upto ground level for entire job contractor will use his own T&P & labour. |
| 76 | For B.T. Road |
| 77 | For C.C. Road |
| 78 | Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost). |
| 79 | In all type Soil |
| 80 | 80 mm to 110 mm |
| 81 | 125 mm to 165 mm |
| 82 | For C.C. Road |
| 83 | 80 mm to 110 mm |
| 84 | Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost). |
| 85 | In all type Soil |
| 86 | 80 mm to 100 mm |
| 87 | For C.C. Road |
| 88 | 80 mm to 100 mm |
| 89 | Labour charges for removal of complaint of polluted water supply to the consumers |
| 90 | Survey of the locality of polluted water supply for preliminary assessment of source of pollution during supply hours |
| 91 | Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size |
| 92 | In all type Soil |
| 93 | 80-110 mm |
| 94 | For C.C. Road |
| 95 | 80-110 mm |
| 96 | Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution CI/DI/MS pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size |
| 97 | In all type Soil |
| 98 | 80-100 mm |
| 99 | For C.C. Road |
| 100 | 80-100 mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender