Tender For Electrical Renovation In 03 Flats At Officers Quarters, Old - Tmc, Parel, Mumbai
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
6 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Electrical Renovation In 03 Flats At Officers Quarters, Old - Tmc, Parel, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point / ceiling fan point / exhaust point / Bell point (with Anchor make ding dong bell) using approved make 3 Nos. 1.5 Sq mm (Red/ Yellow/Blue colour wire for Phase, Black colour wire for neutral and Green colour wire for earth) 1100 Volt copper conductor FRLSH wire in approved make suitable size PVC casing capping and approved make minimum 6 Amp switches mounted on respective make switch plate and PVC surface box, modular angle holder/ceiling rose with required hardware etc. Rate shall include for providing circuit wiring from MCBDB using approved make 3 Nos. 2.5 Sq mm (Red/ Yellow/Blue colour wire for Phase, Black colour wire for neutral and Green colour wire for earth) 1100 Volt copper conductor FRLSH wire in approved make suitable size PVC casing capping with required hardware etc. To terminate wires in switch, socket, angle holder, ceiling rose, mechanical connector. There should not be any joint in the wiring. |
| 2 | Supply and fixing of 2 module step electronic regulators of minimum 100 watts for ceiling fans on the switch boards using three plate ceiling rose mounted on PVC square surface box with required hardwares etc. |
| 3 | Wiring Same as above but for on board minimum 6 Amp plug point controlled by minimum 6 Amp switch. |
| 4 | Wiring for electric point for air-conditioner ( A C ) unit using approved make 3 Nos. 2.5 Sq mm (Red/ Yellow/Blue colour wire for Phase, Black colour wire for neutral and Green colour wire for earth) 1100 Volt copper conductor FRLSH wire in approved make suitable size PVC casing capping from MCBDB and minimum 16 Amp indicator switch mounted on respective make switch plate and PVC surface box at a height of 5’ from floor level and 6/16 Amp socket on respective make switch plate and PVC surface box at a height of 8’ from floor level (beside Split AC indoor Unit, if available) with required hardware etc |
| 5 | Wiring for electric point for Geyser using approved make 3 Nos. 2.5 Sq mm (Red/ Yellow/Blue colour wire for Phase, Black colour wire for neutral and Green colour wire for earth) 1100 Volt copper conductor FRLSH wire in approved make suitable size PVC casing capping from MCBDB and minimum 16 Amp indicator switch mounted on respective make switch plate and PVC surface box inside/outside bathroom and 6/16 Amp socket on respective make switch plate and PVC surface box beside the geyser. |
| 6 | Wiring for 6 Amp Independent power plug point (primary) using approved make 3 Nos. 2.5 Sq mm (Red/ Yellow/Blue colour wire for Phase, Black colour wire for neutral and Green colour wire for earth) 1100 Volt copper conductor FRLSH wire in approved make suitable size PVC casing capping from MCBDB and one no. of 6 Amp switch and 6 Amp socket with interconnection mounted on respective make modular switch plate and PVC surface box. |
| 7 | Same as above but for Secondary 6 Amp switch and 6 Amp socket with mounted on respective make modular switch plate and PVC surface box and same is looped from primary point (item no. 6) complete all accessories as per site requirement on wall as directed By Bank's Engineer. |
| 8 | Same as above but for Secondary 2 x 6 Amp plug point and same is looped from primary point (item no. 6) complete all accessories as per site requirement on wall as directed By Bank's Engineer. T V |
| 9 | Wiring for 16 Amp Independent power plug point (primary) using approved make 3 Nos. 2.5 Sq mm (Red/ Yellow/Blue colour wire for Phase, Black colour wire for neutral and Green colour wire for earth) 1100 Volt copper conductor FRLSH wire in approved make suitable size PVC casing capping from MCBDB and one no. of 16 Amp switch and 16 Amp socket with interconnection mounted on respective make modular switch plate and PVC surface box. |
| 10 | Same as above but for Secondary 16 Amp switch & socket plug point and same is looped from primary point (item no. 9) complete all accessories as per site requirement on wall as directed By Bank's Engineer. |
| 11 | Wiring for TV point using approved make RG 6 copper conductor coaxial cable in approved make suitable size PVC casing capping and required hardwares from common TV splitter in lift lobby area to set top box near TV in Hall cum drawing room (one no.) and making parallel connection in the bed rooms (two nos.). Provide 2 module PVC surface box with t v modular socket, cover & blank plates with required size of metal male / female connectors etc.at three locations in each flat. |
| 12 | Wiring for TV point using approved make RG 6 copper conductor coaxial cable in approved make suitable size PVC casing capping and required hardwares from common TV splitter in lift lobby area to set top box near TV in Hall cum drawing room (two rooms) and making parallel connection in the bed rooms (three nos.). Provide 2 module PVC surface box with t v modular socket, cover & blank plates with required size of metal male / female connectors etc.at three locations in each flat. |
| 13 | Wiring for Telephone point using approved make two pair 0.5 mm copper conductor telephone cable in approved make suitable size PVC casing capping and required hardwares, connection from MDF in lift lobby to telephone point in hall cum living room (one nos.) and making parallel connection in bedrooms (two nos.). Provide two shuttered sockets in each two module surface box with plate of approved make at three / four locations in each flat. |
| 14 | Wiring for Telephone point using approved make two pair 0.5 mm copper conductor telephone cable in approved make suitable size PVC casing capping and required hardwares, connection from MDF in lift lobby to telephone point in hall cum living room (two nos.) and making parallel connection in bedrooms (three nos.). Provide two shuttered sockets in each two module surface box with plate of approved make at three / four locations in each flat. |
| 15 | Supply,installtion,testing and commissioningof high speed ceiling fan,exhaust fans etc |
| 16 | 1400 mm sweep ceiling fan |
| 17 | 1200 mm sweep ceailing fan |
| 18 | 600 mm sweep ceiling fan |
| 19 | 200 mm exhaust fan |
| 20 | Supply,installation,testing and commissioningof following Iight fittings |
| 21 | 4 feet 36 watt LED batten |
| 22 | 1 feet 5 watt LED batten |
| 23 | 15 watt surface mounted round LED fitting |
| 24 | 1 Arm Pure Brass wall bracket fitting with9 watt warm white LED bulb |
| 25 | 3 arm pure brass chandelier fitting with 9 wwarm white LED bulb |
| 26 | Supply, installation, testing and commissioning of approved make 8 way double door metallic TPN MCBDB on wall using required hardware, blank plates etc. and following incomer TPN FP,DP RCCB per phase, MCBs phase wise and termination of all wires and incoming wires( using connectors) / cables (using suitable size single compression gland & copper lugs)etc. The rates shall include carefully removal of existing MCBDB in each flat.32 Amp TPN FP MCB, Qty. 01 No.25 Amp 30 mA DP RCCB, Qty.03 Nos.10 Amp SP MCB ‘C’ Curve, Qty.09 Nos.20 Amp SP MCB ‘C’ Curve , Qty.09 Nos. |
| 27 | Supply, installation, testing and commissioning of approved make FP single door enclosure on wall / meter board in electric meter room using required hardware, blank plates etc. and 40 Amp TPN FP ‘C’ curve MCB etc. and including termination of incoming & outgoing wires ( using connectors, pipes ) / cables ( using suitable size single compression gland ).The rate shall include carefully removal of existing MCBDB box in meter room of each flat. |
| 28 | Supply, installation, testing and commissioning of approved make 4C x 16 sq.mm copper conductor XLPE FRLS insulated 1100-volt armoured cable and 2 runs of 14 SWG copper earth wire on wall using heavy duty GI saddles (minimum three nos. in a length of 1 Mtr) or required support from true ceiling with required hardwares, screws, etc, from meter room TPN enclosure of main supply to TPN MCBDB inside respective flat, using suitable size single compression gland at meter room side & copper lugs. |
| 29 | Carefully removing of existing switchboards, wires, casing capping, MCBDB and handing over of these removed materials flat wise to Caretaker and receipt of the same shall be enclosed along-with bill. Rate shall include for providing temporary electric plug points with RCCB control during the execution civil and electric work at site. |
| 30 | Rebate offered for old wirings, casing capping, pvc pipes, switch boards, old incoming power cable and tube light fittings, single phase DBs etc (except ceiling fans, exhaust fans, cabin fans, Legrand Myrius make switch boards etc.) from flats to be renovated. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender