Tender For Repair To Leakage, Seepage, Overhead Tanks, Roofing, False Ceiling, Compound Wall, Footpath, Hardstanding, Interlocking, Kerbstone And Other Misc Works At Af Stn 3 Wing Under Aor Of Ge (Af) Faridabad
Tender Value
40 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
11 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Leakage, Seepage, Overhead Tanks, Roofing, False Ceiling, Compound Wall, Footpath, Hardstanding, Interlocking, Kerbstone And Other Misc Works At Af Stn 3 Wing Under Aor Of Ge (Af) Faridabad
BOQ
| Sl. No. | Item Description |
| 1 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc complete all as specified and directed. |
| 2 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 3 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 4 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 White cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed.Note :- Payment for providing grooves shall be made separately. |
| 5 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 7 | M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. |
| 8 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and as directed. |
| 9 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 10 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base all as specified and directed. |
| 11 | M&L for 60 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment,(M-35) grade any clours as approved by EIC /GE complete all as specified and directed |
| 12 | M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed |
| 13 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 14 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 15 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed. |
| 16 | M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified and directed. |
| 17 | Dismantling floor, stone, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 18 | M&L for Glazed ceramic coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles, complete all as specified and as directed. |
| 19 | M&L for 15mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry for under floor tiles etc complete all as specified and directed. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 21 | S&F of framed work such as grills gratings, iron plates, etc with ends of bars shouldeed and or roveted or forged into spikes; framed guard bars barred iron doors ladders framed balusters walk way railing framework of Fe-410-0 or Fe-310-0, complete all as specified and directed. |
| 22 | S&F Welded steel wire fabric supplied and fixed, complete to wood or steel menbers not exc 4.00 kg per sqm, complete all as specified and directed. |
| 23 | S&F in repairs for 4 mm thick polycarbonate sheet of any colour as in fencing/roof covering/cladding to wall fixed with coach screws and washers over Aluminium cover Strip 40x3mm and rubber washer in each joint including dismantling existing sheet complete all as specified and directed. |
| 24 | Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed. |
| 25 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed. |
| 26 | Demolition of cement concrete of any description and in any position complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick in CM 1:3 mixed with water proofing compound @ 2% by weight of cement, finished even and smooth without using extra cement in sunken portion of toilet complete all as specified and directed. |
| 28 | M&L PCC 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in sunken's portion of WC and foundation filling and mass concrete and sub base etc complete all as specified and directed. |
| 29 | M&L applying evenly two coat of bituminous paint on new plastered surface for waterproofing coating in sunken portion including cleaning surface complete all as specified and directed. |
| 30 | M&L for non skid ceramic colour tile 7- 8 mm thick (Square/ rectangular) area of each tiles exe 0.08 sqm but not exe 0.11 sqm as in floor set and jointed in neat cement slurry and pointed in colour cement to match the shade of tiles over as and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and directed. |
| 31 | M&l for glazed ceramic colour jointless tiles in vertical surfaces of size 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing plaster in CM 1:4 complete all as specified and directed. |
| 32 | M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra complete all as specified and directed. |
| 33 | M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. . |
| 34 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 35 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 36 | M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care putty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed.Note : Colour and make as approved by GE. |
| 37 | M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 38 | M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 39 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws incl dismantling of old sheets at an position complete all as specified and directed. |
| 40 | Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed. |
| 41 | S & F for 600x600mm plain board panel for ceiling 4.0 to 8.0 mm thk and incl necessary Gl/Alu frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl dismantling of walls and ceiling board any type complete all as specified and directed. |
| 42 | M&L for PVC hollow panelling 5 to 8 mm thick on ceilling with necessary frame work in Design POPUP pattern and any colour approved by engr-in-charge, inclusive of fixing on to ceiling incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed |
| 43 | M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed |
| 44 | Taking down existing roof treatment of any description and any type complete all as specified and directed. |
| 45 | M & L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, incl Brushing neat cement slurry with 3.0kg of cement per Sqm etc complete all as specified and directed. |
| 46 | M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed. |
| 47 | M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified and directed. |
| 48 | M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate in roof padding and surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 49 | M&L for Making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified and directed. |
| 50 | Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, complete all as specified and directed. |
| 51 | S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting ,dismantling existing water tank complete all as specified and directed. |
| 52 | S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting , tank cover dismantling existing water tank complete all as specified and directed. |
| 53 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \\" Tank cleaning on dt _______ \\" complete all as specified and directed.(a) Tank Capacit exc 250 Ltr but n exc 500 Ltr. |
| 54 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \\" Tank cleaning on dt _______ \\" complete all as specified and directed.(a) Tank Capacit exc 500 Ltr but n exc 1000 Ltr. |
| 55 | S&F for Gun-metal globe or gate valves of 20mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. . |
| 56 | S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 15mm-38gms/20mm 45gms /25mm- 65gms) complete all as specified and directed. |
| 57 | S&F 20 mm dia Unions. brass to connect iron to polyethylene and fixed complete all as specified and directed. |
| 58 | S&F stainless steel pegset of six suitable size of length complete all as specified and directed. |
| 59 | Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed. |
| 60 | S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed. |
| 61 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed. |
| 62 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender