Tender For Augmentation Of External Electric Supply And Allied Infrastructure At Dinjan Uner Ge Dinjan
Tender Overview
Project Description
Tender for Augmentation Of External Electric Supply And Allied Infrastructure At Dinjan Uner Ge Dinjan
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Sep-2026 | Corrigendum No. 01 | Date | 07-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for Modular power socket Indepentent board complete all specified and directed.Note :- Cutting chases for concealed conduit point wiring and making good in cement mortar and matching with existing wall surface is deemed included in unit rate. |
| 2 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thrmostate, NRV, connection piece etc. complete all as specified and directed. |
| 3 | S&F modular socket 6/16 Amps 6 pin combined modular type 2 Module, shuttered type, ISI marked complete all as specified and directed.. |
| 4 | S&F switch 16 Amp rating Modular type, 1 Module, one way switch complete all as specified and directed. |
| 5 | S&F MCB SPN 6-32 Amps 'C' Series 10 KA 240 volts complete all as specified and directed. |
| 6 | S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed fancy type chromium plated 15 mm dia bore complete all as specified and directed. |
| 7 | Supply, laying, connection and testing 20 mm bore, Steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 laid to walls and ceilings or laid in floors etc complete all as specified and directed. |
| 8 | Supply, laying, connection and testing 15 mm bore, Steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 laid to walls and ceilings or laid in floors etc complete all as specified and directed. |
| 9 | S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated 20 mm bore complete all as specified and directed. |
| 10 | Disconnecting and taking down, carefully the existing energy meter by deploying skilled manpower and depositing the same to store for safe custody after recording the final reading from the each meters and submitting the same to MES officicals complete all as specified and directed. |
| 11 | Supply , installation, testing and comission of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current,single phase, 2 wires Smart Energy Meter of rating 240 Volt, 5/10-60 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I . The selection of communication technology should be as per the site conditions and as per existing AMISP in the stn to meet the performance. The smart meters should be based on Cellular communication technology and carry min 5 yrs warranty from date of activation complete all as specified and directed. |
| 12 | Supply , installation, testing and comission of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The selection of communication technology should be as per the site conditions and as per existing AMISP in the stn to meet the performance. The smart meters should be based on Cellular communication technology and carry min 5 yrs warranty from date of activation complete all as specified and directed. |
| 13 | Recurring Monthly Sim charges (GPRS/Internet and SMS charges) to be paid to existing AMISP in the station, post commisioning and activation of smart energy meter for 6 month period or till time of sucessful integration with existing AMISP complete all as specified and directed. Note : (i) The meter SIM shall be capable to communicate with existing AMISP in the Stn and shall be integrated with existing HES and MDM network in the stn.(ii) Recurring monthly payment may be claimed by tenderer on monthly basis. |
| 14 | M&L for Sub main wiring with 2 x 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 32 mm dia concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith 1 x 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to main switch board / distribution board and testing on completion complete all as specified and directed. Note :- (i) 2 x 6 Sqmm Sqmm wire, 1 x 6 Sqmm wire and one run of conduit shall be measured as one running meter for payment perpose. |
| 15 | M&L for Sub main wiring with 4 x 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 32 mm dia concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith 1 x 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to main switch board / distribution board and testing on completion complete all as specified and directed. Note :- (i) 4 x 6 Sqmm Sqmm wire, 1 x 6 Sqmm wire and one run of conduit shall be measured as one running meter for payment perpose. |
| 16 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 12 KW (15 KVA), 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB-IV guidelines and Comprising of followings:- |
| 17 | Serial item No. 16.00 continued...(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection, 2-3 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 12 KW(15 KVA) at outdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 8 KW(10 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \\"H\\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi) Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification. |
| 18 | Serial item No. 16.00 continued(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d) All standard relays, circuits and protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer's drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level Please Enable Macros to View BoQ information |
| 19 | Serial item No. 16.00 continued(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d) All standard relays, circuits and protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer's drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender