Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #57284826

Tender For Repair/ Renewal To Conventional Type Tube Lights/ Other Light Fittings With Energy Efficient Fixtures, Exaust Fans, Geysers, Energy Meters & Connected Wirings Of Md/Otm Accns At Dagshai Under Ge Kasauli.

Issued by Statutory Bodies & Commissions/Committees · Solan, Himachal Pradesh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
28 Sep 2026
2 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Renewal To Conventional Type Tube Lights/ Other Light Fittings With Energy Efficient Fixtures, Exaust Fans, Geysers, Energy Meters & Connected Wirings Of Md/Otm Accns At Dagshai Under Ge Kasauli.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Sep-2026 CHANGE OF CRITICAL DATES2 Date 28-Sep-2026
2 12-Sep-2026 CHANGE OF CRITICAL DATES Date 23-Sep-2026
3 12-Sep-2026 CHANGE OF CRITICAL DATES Date 23-Sep-2026

BOQ

Name of Work:- REPAIR/ RENEWAL TO CONVENTIONAL TYPE TUBE LIGHTS/ OTHER LIGHT FITTINGS WITH ENERGY EFFICIENT FIXTURES, EXAUST FANS, GEYSERS, ENERGY METERS & CONNECTED WIRINGS OF MD/OTM ACCNS AT DAGSHAI UNDER GE KASAULI.
Sl. No. Item Description
1Schedule 'A' Section - I
2Taking down carefully copper/aluminium point wiring (light, fan, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
3Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH PVC insulated, unsheathed copper conductor cable in and including PVC Casing-n-caping of any size/dia, medium grade fixed on surface of wall complete incl all PVC accessories / fittings, brass screws, washers etc, incl providing 3mm thick plastic laminated sheet top cover for mounting switches/ sockets on boards with suitable size sunk boxes or with PVC gang boxes as per site requirements and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly including taking down old point wiring and making good the disturbed surfaces with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed for the followings :-
4One light /Exhaust fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed.
5One bell point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed.
6One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed.
7One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed.
8One two way point controlled by two, two way switches 06 Amps complete all as specified and directed.
9All as per serial item No 2.03 here - in - before but with 4 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed.
10Taking down carefully copper/aluminium point wiring (light, fan, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
11Material and labour for point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit concealed in walls by making cutting in brick/stone masonry wall of required size with all fittings and accessories, incl sunken boxes and hylem sheet alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly including taking down old point wiring and making good the disturbed surfaces with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed for the following :- Note : (i) The Switch, sockets shall be mounted on newly provided MS sunken boxes with in and incl 3mm thick hylem sheet of suitable size. (ii) The rate for sunken boxes, hylem sheet and all accessories shall deemed to be included in the quotes rates of the item itself. No seperate payment shall be made in this regard.
12One light / Exhaust fan point controlled by one, one way switch 06 Amps complete all as specified and directed.
13One bell point controlled by one, one way switch 06 Amps complete all as specified and directed.
14One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed.
15One 3 pin,06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed.
16One two way point controlled by two, 2 way switches 06 Amps complete all as specified and directed.
17All as per serial item No 4.03 here - in - before but with 4 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed.
18Supply and fix in replacement of switch piano flush type, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
19Supply and fix in replacement of switch piano flush type,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
20Supply and fix in replacement of socket outlet 2 in 1, 3 pin, 6 &16 Amps 240 volts complete all as specified & directed by Engr-in-Charge
21Supply and fix in replacement of socket outlet 3 pin, 06 Amps 240 volts complete all as specified & directed by Engr-in-Charge
22Supply and fix in replacement of bell push flush type , 06 amps , 240 volts all as directed by Engr-in-Charge
23Supply and fix in replacement of door bell ding dong type , 240 volts AC all as directed by Engr-in-Charge
24Supply and fix in replacement of switch piano flush type, 06 Amps single pole, two way 240 volts complete all as specified & directed. by Engr-in-Charge
25Supply and fix in replacement of lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge.
26Supply and fix in replacement of ceiling rose surface, bakelite, three terminal, 240 volts complete all as specified and directed.
27Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed by Engineer - in - Charge.
28Material and labour in Replacement for sub main wiring with (2 Run) of single core PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC concealed conduit of required size with all fittings and accessories alongwith one single core green colour PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, all as specified and directed. Note :Thimble/ lugs of suitable rating of MCB should be used with wire for fixing in the MCB. (ii) Three Runs of cable and one run of PVC conduit shall be measured and paid as one unit length . (iii) All chases will be cut by chase cutter only.
29Material and labour in Replacement for sub main wiring with (2 Run) of single core PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC concealed conduit of required size with all fittings and accessories alongwith one single core green colour PVC insulated sheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, all as specified and directed. Note :Thimble/ lugs of suitable rating of MCB should be used with wire for fixing in the MCB. (ii) Three Runs of cable and one run of PVC conduit shall be measured and paid as one unit length . (iii) All chases will be cut by chase cutter only.
30Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.NOTE:- Make of DBs boxes and MCCBs/MCBs shall be of same make.
31Supply and fix in replacement of DB SPN 4 way double door, IP 54 & IK09 certified with fully shrouded Neutral Bar ,PU gasket, 200 Amp rated bus bar 240V conforming to IEC 61439-3 ,CRCA sheet powder coated factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blanking plate as required and making good disturbed surface to match with existing complete all as specified and as directed.
32-Ditto- all as per item No 18.00, but of size 8 way SPN.
33-Ditto- all as per item No 18.00, but of size 12 way SPN.
34Supply and fix in replacement of MCB SP, 'B' series, 6 Amp to 32 Amp, having rupture capacity of not less than 10 KA including taking down unserviceable complete all as specified and as directed.
35Supply and fix in replacement of MCB SPN, 'C' series, 40-63 Amp, having rupture capacity of not less than 10 KA including taking down unserviceable complete all as specified and as directed.
36Supply and fix in replacement of in replacement of VTPN DB 4 way, vertical loadline type, double door, for MCCB as incomer, metal door, shrouded Neutral Bar, Mechanical Impact Strength IK 09 certified, fully insulated busbar assembly, 2 neutral bar, 2 earth bar, cable ties, blanking plates, PU gasket suitable for 4 pole MCCBs upto 160 Amp as incomer and MCBs (TP/TPN/SP/SPN) as outgoing, IP 54 protection, conforming to IEC 61439-3 complete all as specified and directed.
37Supply and fix in replacement of MCCB 4 Pole, 100 Amps, 16 KA 415 Volt, including taking down unserviceable complete all as specified and as directed.
38Supply and fix in replacement of MCCB 4 Pole, 63 Amps, 16 KA 415 Volt, including taking down unserviceable complete all as specified and as directed.
39Supply and fix in replacement of Isolator 4 Pole 'C' series 100 amps capacity AC 415 V,10kA complete all as specified and directed.
40Supply and fix in replacement of Isolator 4 Pole 'C' series 63 amps capacity AC 415 V,10kA complete all as specified and directed.
41Material and labour for taking down the unsv geyser of 25/35/ 50 ltr capacities from the site after disconnecting the water connection, electric connection, opening the geyser assembly and descalling the deposits in the inner container and outlet water pipe set complete all as directed by Engineer-in-Charge. (Note:- (i) Replacement of unsv bolts, rubber real, ring nuts, washers to be included in the rate quoted by tenderer. (ii) Material & labour for GI fittings and other connected works shall be measured and paid for separately under respective items of schedule ‘A’ here in after) :-
42Supply only geyser syphon assembly steel plate with nuts and bolts, washers, clamps and rubber ring suitable for geysers of 25/35/ 50 Ltr capacity of make and model as per eixsting one complete all as directed by Engineer-in-Charge.
43Supply only Thermostatic switch, ISI marked, suitable for geysers of 25/35/ 50 capacity of make and model as per eixsting one complete all as directed by Engineer-in-Charge.
44Supply only Heating element 1.5/2 KW capacity with rubber ring Round/triangular type complete with clamps, nuts and bolts washers, etc for geysers, ISI marked suitable as per existing make and model
45Supply only Non return valve 15mm dia made of bronze ISI marked heavy duty omplete all as directed by Engineer-in-Charge.
46Supply only 15mm dia PVC connection 450 mm long , suitable for hot water supply, complete with 2 Nos brass nuts complete all as directed by Engineer-in-Charge.
47Supply only 15mm dia PVC connection 450 mm long , suitable for cold water supply, complete with 2 Nos brass nuts complete all as directed by Engineer-in-Charge.
48Supply only Zebra fastner of size 12x100 mm suitable for geysers of any capacity of make and model as per eixsting one complete all as directed by Engineer-in-Charge.
49Supply and fix exhaust fan, PLASTIC body heavy duty AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers including taking down unserviceable complete all as specified and as directed.
50Supply and fix exhaust fan, steel body heavy duty AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers including taking down unserviceable complete all as specified and as directed.
51Supply and fix exhaust fan, steel body heavy duty AC single Phase 230V of size 450mm sweep with, blades, and frame and louvers including taking down unserviceable complete all as specified and as directed.
52Supply and fix in replacement of self ballasted LED Retrofit Bulb 5 Star Bulbs (9-12) Watt with PBT body shell and PC diffuser 210 degree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) complete all as specified and as directed.
53Supply and fix in replacement of LED Mirror light fitting 1 x 10 W, 2 feet ,220V, AC, decorative type with driver holder including LED lamp,extruded aluminium channel in thermally conductive material and luminaire efficacy 110 lm/W, beam angle 120 degree, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
54Supply and fix in replacement of LED Bulk head 1 x 10 W ,220V, AC, decorative type extruded aluminium channel in thermally conductive material and luminaire efficacy 110 lm/W, beam angle 120 degree, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
55Supply and fix in replacement of wall mounted decorative fancy light fitting with single glass and brass base as per sample or as approved by Engr-in-Charge suitable for (10-12) watts LED lamp including one number LED lamp (10-12) watt of coolday/warm white of base E-14/E-27/B-22, fixing on wall with all items required for fixing all as specified and directed by Engr-in-Charge.
56Supply and fix in replacement of LED Tube light fitting 1 x 20 W, 220V, AC, decorative box type with driver holder including LED tube light, aluminium extrusion body with powder coating, suitable for retrofit LED 1x20W LED tube rated luminaire efficacy 110 lm/W, beam angle 120 degree, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
57Supply and fix in replacement of LED tube light fitting Inverter Type Emergency light 1 x 20 W, 220V, AC, decorative box type with driver holder including LED tube light, aluminium extrusion body with powder coating, suitable for retrofit LED 1x20W LED tube rated luminaire efficacy 110 lm/W, beam angle 120 degree, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
58Supply and fix in replacement of 2'x2' LED luminaire 36watts, 6500k, Ultra modern recess mounting luminaire with high performance LEDs, P.f -0.9 , 3600lm lumens suitable for mounting with Armstrong/Grid ceiling including all acessories for fixing in false ceiling/ceiling/in hanging position all as specified and directed by Engr-in-Charge.
59Supply and fix in replacement of LED post top light fitting(20-22)Watt IP65 Rated LED Post Top ideal to lit up parks, garden ways and heritage sites incl LED light and making connections complete all as specified and directed by Engr-in-Charge.
60Supply and fix in replacement of Recess mounting ceiling fitting 1'X4' LED 36/40 Watt light Edgelit slim panel having white powder coated extruded aluminium body with high quality LPG and PMMA diffuser, Separate HPF driver, Suitable for Armstrong and Grid ceiling, PF min 0.95 complete incl dismantling taking out unsv one of any make/ size complete all as specified and as directed.
61Supply and fix in replacement of 1'x1' LED luminaire 15-20 watts, 4000k,1125lm, 240V white color Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling including all acessories for fixing in false ceiling/ceiling/in hanging position all as specified and directed by Engr-in-Charge.
62Supply and fix in replacement of PVC gang box 2 WAY suitable for 6 Amp Socket and 6 Amp switch complete all as per specified and directed
63Supply and fix in replacement of PVC gang box suitable for 16 Amp Socket and 16 Amp switch complete all as per specified and directed
64Supply and fix in replacement of PVC Plug Top 6 amps complete all as specified and as directed.
65Supply and fix in replacement of PVC Plug Top 16 amps complete all as specified and as directed.
66Supply and fix in replacement of Distribution modular box with MCB protection Execution (pole) 4 Module and including 20 Amps rating MCB, single pole, AC, 240 volts with Specification as per IS:13032 & IS:8623, (Dimension approx 46.5 x 42.8 x 26 Centimeters), PVC Plastic Material, White Color mounting on wall surface, complete all as directed by Engineer - in - Charge.
67Supply and fix in replacement of modular switch socket combination 16 A, 6 pin, 3 module which includes white cover plate with frame 3 module and PVC Surface mounted box 3 module complete all as specified & directed by Engr-in-Charge.
68Supply and fix in replacement of modular switch socket combination 03 pin 06 A,3 Module which includes white cover plate with frame 3 Module and PVC surface mounted box 3 Module type complete all as specified & directed by Engr-in-Charge.
69Supply and fix in replacement of 15mm dia 304 grade stainless steel connection pipe 450 mm long , suitable for hot & cold water supply ,complete with 2 Nos brass nuts complete all as specified and directed.
70Supply and fix in replacement of 15mm dia 304 grade stainless steel connection pipe 900 mm long , suitable for hot & cold water supply ,complete with 2 Nos brass nuts complete all as specified and directed.
71Supply and fix in replacement of 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10.0 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed.
72Supply and fix in replacement of 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6.0 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed.
73Dismantling taking out carefully old/unserviceable UG cable of any type/ size from trenches/pole/duct/LT panel after disconnecting from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of credit.
74Supply, laying, commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 10 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc in replacement of old unsv cable complete all as specified and directed.
75Supply, laying, commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 6 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc in replacement of old unsv cable complete all as specified and directed.
76Supply, laying, commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 10 Sqmm 4 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc in replacement of old unsv cable complete all as specified and directed.
77Supply, laying, commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16Sqmm 4 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc in replacement of old unsv cable complete all as specified and directed.
78Fixing only and connecting electric meters above 25 amps marked in existing meter board and making all necessary connections complete all as specified and directed by Engr-in-charge. Note: (i) New Energy meter to be fixed shall be supplied by MES. (ii) Old unservicable meters retrieved shall be deposited to MES store for disposal action.
79Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in hard/dense soil and gating out in hard/dense soil complete all as specified and directed.
80Material and labour for double walled corrugated HDPE duct pipe of 50 mm outer dia confirming to IS-14390(Part-II) of approved colour with fittings for cable protection complete all as specified.
81Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft / loose soil complete all as specified and directed.
82Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed.
83Supply and fix in replacement of MCCB 125 Amps 4 Pole 415 V, 50 Hz adjustable thermal type ( 80% to 100% ) and adjustable magnetic setting, breaking capacity 16 kA , ICS =100 ICU with extended terminals connecting up in the existing panel complete all as specified and as directed by Engineer-in-Charge.
84All as per item No. 63.00 here in before but MCCB 160 Amps 4 Pole, 36 kA, 415 V, 50 Hz complete all as specified and directed.
85Taking down old unserviceable earthing by disconnecting the existing and making good the disturbed surfaces of floor to match the existing complete all as specified and directed by Engineer - in - Charge.
86Material and labour for chemical earthing GI earth electrode with medium grade of size 50mm dia upto 2 meter below ground level Installation, testing and commissioning of chemical earthing complete with buried directly in ground vertically to a depth not less than 2mtr below normal ground level earth electrode GI pipe connected to and incl galvanised earthing lead strip 32 x 6mm as main earthing lead by means of tinned copper/ brass bolts, nuts, check nuts and washer beside brazing at all joints as directed and earthing lead protected with 40mm dia light grade GI pipe from electrode and upto incl the earth test point, including alternate layers of 150mm thickness each of charcoal, common salt, magnisium sulphate/ chemical and as per manufacturer's recommendation including below the copper electrode also and excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate, RCC cover 50mm thick in RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia MS deformed bars @75 mm C/C both ways incl MS angle iron frame of size 40mmx40mmx3mm and incl testing the earthing on completioin, complete all as specified. The result of the earth resistance should be less that 1.0 Ohm and recorded results to be submitted to Engr-in-Charge.Note :- (i) Old earthings are conventional type and sch of credit has been accounted for accordingly. (ii) Chemical to be used for earthing should be Marconite.
87Material and labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
88Taking down old unserviceable Meter Panel by disconnecting the existing and making good the disturbed surfaces of Wall to match the existing complete all as specified and directed by Engineer - in - Charge.
89Supply and fix in replacement of installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make approved in MES list. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
90Contd... Srl Item No. 69.00:- The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 63A FP 16KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Provision Four Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 4 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply.
91Supply and fix in replacement of installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make approved in MES list. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
92Contd... Srl Item No. 70.00:- The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 100A FP 16KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Provision Six Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 6 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply.
93Supply, installation, testing and commissioning of Tri-Colour LED Strip Light ,operating on 230V AC through suitable LED driver, capable of providing Warm White, Neutral White and Cool White illumination with colour-changing control. The strip shall be flexible, high-efficiency SMD LED type mounted on PCB with adhesive backing, complete with connectors, mounting accessories, driver, controller and all associated wiring as required. The LED strip shall have minimum efficacy of 100 lm/W, CRI ≥ 80, rated life ≥ 50,000 hours, and suitable IP rating as per installation location, complete in all respects as directed by Engineer-in-Charge.
94Amount of credit of Rs. 67747.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57284826
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 28-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Renewal To Conventional Type Tube Lights/ Other Light Fittings With Energy Efficient Fixtures, Exaust Fans, Geysers, Energy Meters & Connected Wirings Of Md/Otm Accns At Dagshai Under Ge Kasauli.
Basic Detail
Tender No GEK-34/2026-27
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 17 Sep 2026
Submission Date 28 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
205074bc-4254-43ef-bb8d-691a94dfcc77.html
BOQ_882022.xls
GEK34.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Sep 23, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 23, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

205074bc-4254-43ef-bb8d-691a94dfcc77.html

xls

BOQ_882022.xls

pdf

GEK34.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail