Rural Development Government Departments Closing in 1 days TDR #57283376

Tender For Construction of Goa To Chulla

Issued by Government Departments · Kurung Kumey, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Sep 2026
1 days left
EMD
15.59 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kurung Kumey → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction of Goa To Chulla

BOQ

Name of Work:- C/o Goa to Chulla
Sl. No. Item Description
1SUBGRADE PREPARATION
2Loosening of the ground upto a level of 300mm below the sub grade level watering graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per technical specification Clause 303.5.2
3EARTHEN SHOULDER
4Construction of sub-grade and earthen shoulders with approved material obtained from borrow pith with all lifts and leads, transportating to site, spreading , grading to required slope compacted to meet requirement of Table 300.2 with lead upto 1000 m as per technical specification clouse 303.1.
5GRANULAR SUB-BASE (150 mm thick)
6Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. i) Using naturally occuring gravel
7CEMENT TREATED BASE COURSE (100 mm thick)
8Cement Treated Base (CTB) with 75% local & 25% borrow materials (a) For 5% quantity of cement by weight of soil.
9PRIME COAT
10Providing and applying prime coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using m/means as technical specification Clause 502. Low Porosity
11TACK COAT
12Providing and applying tack coat with bitumen emulsion (RS -1 ) using emulsion distributer at the rate of 0.25 sqm to 0.30 sqm kg per sqm on the prepared granular surface trated with primer & cleaned with hydraulic boom as per tech specification Clause 503.
13Mix Seal Surfacing
14Mix Seal Surfacing : Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509
15Item : Hume Pipe Clvt. 1000 mm dia.TYPE-I (As per IRC SP-20-2002 & SP :48-1998)
16Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
17Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
18Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 [P.C.C. grade M 20 Nominal mix (1:2:4)]
19Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ]
20Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
21Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 [In 1:4 cement mortar]
22Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia]
23Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
24Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]
25Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
26Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
27Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20]
28Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
29Item : Slab Culvert 1.50 mtr. span, 3.13 mtr high (As per IRC SP-20-2002)
30Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. 1.Ordinary Soil (i) Upto 3 Mtr. Depth
31Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. I (PCC grade M10)
32i) Nominal Mix 1:3:6
33Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. CRM 1st Sort (i) 1:3
34Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. CRM 2nd Sort (ii) 1:4
35Back filling behind the abutment, wing wall and retain wall complete as per the drawing & technical specification.[Granular material] Rate as per item No. 12.10 of Chapter 12
36Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawingand technical specification Clauses 614, 709, 1204.3.7
37Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. R.C.C grade M 20
38Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. R.C.C grade M 20
39Providing and laying curtain walls complete as per drawing and technical specification Clause 1304. (III) Cement concrete grade M 10
40Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. a) For nominal mix 1:2:4[hand mixing]
41a) For nominal mix 1:2:4[hand mixing]
42Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/JINDAL/SHYAM STEEL)
43a) MS Deformed Bars
44Item : Slab Culvert 2.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002)
45Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.
46Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)
47a) Foundation & Plinth
48Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
49Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
50Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.
51Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
52Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (R.C.C grade M 20)
53Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (R.C.C grade M 20)
54Providing concrete for plain concrete for curtain walls complete as per drawings and technical specifications Clause 1303.3(PCC grade M10)
55Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
56a) For nominal mix 1:2:4[hand mixing]
57Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary
58a) MS Deformed Bars
59Item : Slab Culvert 4.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002)
60Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.
61Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)
62a) Foundation & Plinth
63Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
64Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
65BackFilling behind abutment, wing wall and return wall complete as per drawing & techanical specification Clause 1204.3.8(Grannular Meterial)
66Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7
67Plain/reinforced cement concreete in substructure as per drawing and techanical specification Clauses 802,804,805,806,807,1202 and 1204 (RCC grade M20)
68Plain/reinforced cement concreete in substructure as per drawing and techanical specification Clauses 802,804,805,806,807,1202 and 1204 (RCC grade M20)
69Providing concrete for plain concrete for curtain walls complete as per drawings and technical specifications Clause 1303.3(PCC grade M10)
70Plain/reinforced cement concreete in superstructure as per drawing and techanical specification Clauses 800,1205.4 and 1205.5 (RCC grade M25)
71a) For nominal mix 1:1.5:3[hand mixing]
72Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary
73a) MS Deformed Bars
74Item : Slab Culvert 6.00 mtr. span, 6.00 mtr high (As per IRC SP-20-2002)
75Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.
76Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)
77a) Foundation & Plinth
78Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
79Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
80BackFilling behind abutment, wing wall and return wall complete as per drawing & techanical specification Clause 1204.3.8(Grannular Meterial)
81Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7
82Plain/reinforced cement concreete in substructure as per drawing and techanical specification Clauses 802,804,805,806,807,1202 and 1204 (RCC grade M20)
83Plain/reinforced cement concreete in substructure as per drawing and techanical specification Clauses 802,804,805,806,807,1202 and 1204 (RCC grade M20)
84Providing concrete for plain concrete for curtain walls complete as per drawings and technical specifications Clause 1303.3(PCC grade M10)
85Plain/reinforced cement concreete in superstructure as per drawing and techanical specification Clauses 800,1205.4 and 1205.5 (RCC grade M25)
86a) For nominal mix 1:1.5:3
87Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary
88a) MS Deformed Bars
89RCC Bridge 10 Mtr. clear span
90Abutment
91Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
92(i)Ordinary soil Upto 3 m depth
93(ii)Below water level Marshy soil
94Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
95P.C.C grade M 10[nominal mix 1:3:6]
96Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
97P.C.C grade M 15 [Nominal mix 1:2.5:5(Hand mixing)]
98Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
99R.C.C grade M 20
100Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
101Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
102(i) Granular material
103Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary
104Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete, including all accessories as per drawings and technical specification Clause 1207.1
105RETURN WALL
106Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.
107(i)Ordinary soil Upto 3 m depth
108(ii)Below water level Marshy soil
109Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
110P.C.C grade M 10[nominal mix 1:3:6]
111Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
112P.C.C grade M 15 [Nominal mix 1:2.5:5(Hand mixing)]
113Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
114Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
115(i) Granular material
116Supplying, fitting, and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
117DECK SLAB
118Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
119R.C.C. grade M 25 [for height upto 5Mtr]
120Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
121Drainages spouts complete as per drawing and technical specification clause 1209.
122Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
123Providing and laying a buried expansion joint, covered with 12 mm thick, 200 mm wide galvanised weldable structrual steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8mm dia, 100mm long galvanised nails spaced 300mm c/c along the centre lne of the plate. as per technical specifications Clauses 1207.2.3
124Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
125Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
126Construction of RCC guide posts of 250 mm dia M20 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2
127SUB-HEAD:- Side Drain[Trapezoidal Drain]
128Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
129Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]
130Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]
131Cement plaster 15 mm thick 1:4 on stone masonry
132Item :-Road Furniture:-
133Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
134a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)
135b) 5th Km. Stone (size 107.50x58x25cm)
136c) 200m stone (precast)
137Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
138Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
139Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
140Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
141Providing and Fixing PMGSY Logo Board at starting point
142Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint.
143Providing and Fixing Title information Board of PMGSY Project(RCC)
144Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
145Providing and Fixing Citizen information Board of PMGSY Project(RCC)\\"A\\"
146Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
147Safety Devices and Signs in Construction Zones
148Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001.
149Men at work
150Diversion
151Road closed
152Speed limit
153(SH : KUTCHA SIDE DRAIN)
154Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
155Ordinary Soil
156Ordinary Rock
157Maintenance
158First Year
159Second Year
160Third Year
161Fourth Year
162Fifth Year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57283376
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 08-09-2026
Authority
Authority Name Rural Works Division
Work Description Tender for Construction of Goa To Chulla
Basic Detail
Tender No C/o road from Goa to Chulla
Bidding Type Tender
Location
City Kurung Kumey
State Arunachal Pradesh
Key Dates
Publish Date 01 Sep 2026
Submission Date 08 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 15000
EMD 15.59 Lakhs
Exemption Available
Document List
BOQ_235147.xls
f8d2a8f4-2b99-483b-826a-eb193e3e7c74.html
GoatoChullaSBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_235147.xls

html

f8d2a8f4-2b99-483b-826a-eb193e3e7c74.html

pdf

GoatoChullaSBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders