Tender For special Repair/Replacement Of Various Lt Panels With Connected Items At Sub-Stns Rupa Of Age E/M Under Ge Tenga
Tender Value
38.60 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
15 days left
EMD
77200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair/Replacement Of Various Lt Panels With Connected Items At Sub-Stns Rupa Of Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out. |
| 2 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 3 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 4 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 5 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed. |
| 6 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following |
| 7 | (a) Aluminium bus bar four Nos 1200 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) ACB, 04 Pole, 800 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with Microprocessor settings - 01 No Outgoing:- (c) MCCB, 4 Pole, 250 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 200-250 Apms conforming to IEC 60947 Part-I/IS-13947 Part-I - 07 No (Ics=Icu=100%) (d) MCCB, 4 Pole, 160 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 125-160 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(e) MCCB, 4 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings 50-63 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(f) Spare for MCCB upto 250A (g) MCB SPN 32 AMP 10 KA - 03 Nos |
| 8 | (h) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, - 1Set. (i) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (k) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel |
| 9 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following |
| 10 | (a) Aluminium bus bar four Nos 800 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 500 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic of range 500-630 Amps settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB, 4 Pole, 250 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 200-250 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) (d) MCCB, 4 Pole, 160 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 125-160 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 06 No (Ics=Icu=100%)(e) MCCB, 4 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 50-63 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(f) Spare for MCCB upto 250A (g) MCB SPN 32 AMP 10 KA - 03 Nos |
| 11 | (h) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA - 1Set. (j) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (k) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (l) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel |
| 12 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following |
| 13 | (a) Aluminium bus bar four Nos 800 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 500 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic of range 500-630 Amps settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB, 4 Pole, 250 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 200-250 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%) (d) MCCB, 4 Pole, 160 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 125-160 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(e) MCCB, 4 Pole, 125 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 100-125 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%)(f) MCCB, 4 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 50-63 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(g) Spare for MCCB upto 250A (h) MCB SPN 32 AMP 10 KA - 03 Nos |
| 14 | (i) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA - 1Set. (j) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (k) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (l) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel |
| 15 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following |
| 16 | (a) Aluminium bus bar four Nos 300 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 125 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 100-125 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 50-63 Amps conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%) (d) MCB SPN 32 AMP - 03 Nos (e) MCB TPN 32 AMP - 02 Nos |
| 17 | (f) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, - 1Set. (g) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel |
| 18 | Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 300 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires.Note : Earth work, sand filling & PCC cover laying shall be measured and paid separately. |
| 19 | Description all as per item No 10 above but of size 150 Sqmm 3.5 core |
| 20 | Description all as per item No 10 above but of size 120 Sqmm 3.5 core |
| 21 | Description all as per item No 10 above but of size 95 Sqmm 3.5 core |
| 22 | Supply and laying galvanised tube light grade ISI marked of size 80 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed. |
| 23 | M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed. |
| 24 | Supply and laying HDPE pipe PN10, ISI marked, for cable protection on pole/wall/floor or in trenches and drain/culvert etc complete with necessary clamps, nuts, bolts, washers sockets complete with all fitting of size 75 mm bore all as specified and directed. |
| 25 | Supply and laying HDPE pipe PN10, ISI marked, for cable protection on pole/wall/floor or in trenches and drain/culvert etc complete with necessary clamps, nuts, bolts, washers sockets complete with all fitting of size 100 mm bore all as specified and directed . |
| 26 | S & F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 300 sqmm all as specified and directed. |
| 27 | S & F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120-185 sqmm all as specified and directed. |
| 28 | S&F of 1100 Volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size 4 Smm 2 core all as specified and directed. |
| 29 | S&F of 1100 Volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size 6 Smm 2 core all as specified and directed. |
| 30 | M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 40 mm dia medium grade GI pipe and 20 mm dia medium grade GI Pipe for watering complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender