Tender For Repair, Replacement Of Security Lights, Poles, Timer Switches, Connection Cables And Allied Works At Ph- Iii (U And L Dahung, Dum Dum Nalla, Mh ,Mes Offices And Messes) Of Age E/M Under Ge Tenga
Tender Overview
Project Description
Tender for Repair, Replacement Of Security Lights, Poles, Timer Switches, Connection Cables And Allied Works At Ph- Iii (U And L Dahung, Dum Dum Nalla, Mh ,Mes Offices And Messes) Of Age E/M Under Ge Tenga
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Sep-2026 | DATE CORRIGENDUM | Date | 05-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 4 core including taking down of old unserviceable UG cable/service wire complete all as specified and directed.Note : Earth work, sand filling & PCC cover laying shall be measured and paid separately |
| 2 | Description all as per item No 1 above but of size 16 Sqmm 2 core |
| 3 | Description all as per item No 1 above but of size 10 Sqmm 2 core |
| 4 | Laying only in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of different sizes including taking down of old unserviceable UG cable/service wires. Note : (i) Earth work, sand filling & PCC cover laying shall be measured and paid separately. (ii) XLPE Cable will be issued under Schedule 'B' as free for fixing. |
| 5 | Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed. |
| 6 | M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed. |
| 7 | Supply and laying HDPE pipe PN10, ISI marked, for cable protection on pole/wall/floor or in trenches and drain/culvert etc complete with necessary clamps, nuts, bolts, washers sockets complete with all fitting of size 50 mm bore all as specified and directed by Engineer-in-charge. |
| 8 | S&F in replacement Junction box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacity with 6 Amp MCB single pole , of minimum size 155x210x92mm, fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps complete all as directed. |
| 9 | S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 32 mm dia, medium grade, 1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed. |
| 10 | M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity as specified and directed. |
| 11 | Description all as per item No 10 above but of capacity 60 Watt |
| 12 | Description all as per item No 10 above but of capacity 90 Watt |
| 13 | M&L for replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 70 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity all as specified and directed. |
| 14 | Description all as per item No 13 above but of capacity 120 Watt |
| 15 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with two coats of aluminium paint over one coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. |
| 16 | M& L for cable 1.5 sqmm 3 core PVC insulated multistranded copper cable with PVC insulated copper conductor with PVC cover for connection between Junction box and street light with all as spd and directed. |
| 17 | Supply , fixing and testing of Street light Panel including 3 phase automatic street light switch using integrated sensor based Nature Switch for automatic switching of street lights .The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB (3 Nos) rating 63 Amps (b).Contactor MCB (3 Nos) rating 63 Amps (c).Out put MCB (3 Nos) rating 63 Amps (d).Three phase circuit wiring with multistranded copper wire. |
| 18 | Supply, fixing and testing of Street light Panel of single phase automatic street light switch using integrated sensor based Nature Switch for automatic switching of street lights . The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress single phase 6KW lightning load capacity including mounting bracket , cable glands, front openable doors fitted with hinges & locking arrangment complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 6 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 40 Amps SPN (b).Contactor MCB rating 40 Amps (c).Out put MCB rating 40 Amps (d).Single phase circuit wiring with multistranded copper wire. |
| 19 | Supply, fixing and testing of Street light timer of single phase multifunctionAstronomical time switches using integrated sensor based for automatic switching of street lights complete all as specified and directed. |
| 20 | M&L PCC in mix 1:4:8 type D2 with 40 mm graded aggregate for poles / filling in mass concrete complete all as specified and directed. |
| 21 | M&L for PCC 1:3:6 Type C2 for erection of pole in base with 40 mm gradede coarse agreegete complete all as specified and as directed. |
| 22 | M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including from work for poles all as specified and directed by Engr-in-charge. |
| 23 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out all as specified and directed. |
| 24 | Excavation in trenches in any type of soil exc 1.5 mtrs wide and not exc 3 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out all as specified and directed. |
| 25 | Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 26 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 27 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 28 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete all as specified and directed |
| 29 | Material and labour for painting steel tubular pole/ angle iron bracket pole (410 SP -31) 9 mtr long, complete with throughout entire length of pole preperation of new or old painted steel surface exceeding 10cm width or girth, including cleaning, washing and applying two coat of aluminium paint anticorossive over a coat of red oxide primer on outer sufaces of poles/pipes complete all as specified and directed. |
| 30 | S&F of 1100 Volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size 6 Sqmm 2 core. |
| 31 | S&F of 1100 Volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size 10 Sqmm 2 core. |
| 32 | S&F for replacement of Sollar battary 12 V 80 Ah maintenance free |
| 33 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender