Tender For Construction Work Of Chief Minister Model Composite Vidhyalaya (Pre-Primary To Class 12Th) At Vikas Khand-R Ur Sangramgarh, Villege-R Ur Bawli, Tehsil-Lalganj, Distt- Pratapgarh.

Issued by Boards / Undertakings / PSU · Pratapgarh, Uttar Pradesh
Tender Value
19.86 Crore
Estimated cost
Bid Submission
29 Sep 2026
22 days left
EMD
39.73 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pratapgarh → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Work Of Chief Minister Model Composite Vidhyalaya (Pre-Primary To Class 12Th) At Vikas Khand-R Ur Sangramgarh, Villege-R Ur Bawli, Tehsil-Lalganj, Distt- Pratapgarh.

BOQ

Name of Work:- CONSTRUCTION WORK OF CHIEF MINISTER MODEL COMPOSITE VIDHYALAYA (PRE-PRIMARY TO CLASS 12TH) AT VIKAS KHAND-R UR SANGRAMGARH, VILLEGE-R UR BAWLI, TEHSIL-LALGANJ, DISTT- PRATAPGARH.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
3Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
6Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints,surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 ( Part II 1981 ) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used. The rate of application of chemical emulsion shallbe as follows : (1 Treatment for masonary & foundation 5 liters pe r/ 100 Sqm.(2) Back fill in immediate contact with foundation 7.5 liters / 100 Sqm. (3) Treatment of top surface of plinth filling 5 liters / 100 Sqm. (4)Treatment junction of wall and the floor 7.5 liters / 100 Sqm. (5)Treatment of soil along external perimeter of building 7.5liters / 10 Sqm.(6) Treatment of soil under apron along external perimter 5 liters / 100 Sqm.
7Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] M-20.
8Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR SUNSHADE] M-20.
9Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). beam
10Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab
11Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (foundation)
12Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) columns,
13Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand)
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
18Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
19Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
20Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). Double leaf
21Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Single leaf
22Providing and fixing mild steel round holding down bolts with nuts and washer plates complete
23Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
24Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
25Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
26Providing and fixing anodised aluminium doors,having 2 mm thick Aluminium section excluding coating & an average coating of 20 micron fully glazed made of Aluminium door tube size 83.5x44.65 mm as Vertical member and 11.40x44.45mm size tube in bottom & horizontal members Door chaukhat ahould be ofAluminium tubler vertical with two openable shutter. The rate will include cost of material fixture 5mm glass handles,locks,screw necessary beeding & excluding cost of floor spring if requred for proper complection of work as per direction of Engineer-in-charge. With 5 mm thick glass
27Providing and fixing anodised aluminium grill (anodised transparentor dyed to required shade according to IS: 1868 with minimum anodiccoating of grade AC 15) of approved design/pattern, with approvedstandard section and fixed to the existing window frame with C.P.brass/ stainless steel screws @ 200 mm centre to centre, includingcutting the grill to proper opening size for fixing and operation ofhandles and fixing approved anodised aluminium standard sectionaround the opening, all complete as per requirement and directionof Engineer-in-charge. (Only weight of grill to be measured forpayment).
28Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
29Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 1.0 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
30Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
31Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. (a) Door chaukhats
32Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. (b) Window chaukhats
33Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. (c) Ventilator chaukhats
3415 mm cement plaster on rough side of single or half brick wall of mix: 1 :4 (1 cement: 4 coarse sand)
3512mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand
3615mm thick plasteron rough side of single or half brick wall of mix: 1 :6 (1 cement: 6 coarse sand)
37Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster
38Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
39Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
40Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
41Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING]
42Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING]
43Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete [IN FLOORING]
44Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete [IN SKIRTING]
45Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
46Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING]
47Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING]
48Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent
49Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edgesto give high gloss finish etc. complete at all levels.
50Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
51Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete On steel work
52Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm :
53Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
54Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm)
55Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre .
56Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
57Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
58Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm
59P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm
60P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 150x10mm
61Providing & fixing stainless steel door handles with screws and 150mm long.SI marked
62Providing & fixing stainless steel sliding door bolts ISI marked required colour or shade with nuts and screws etc complete.300X12 MM
63P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc complete.300X10 MM
64P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc complete.250X10 MM
65Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.
66Making drain along with apron.
67S/F of glass strips for flooring.35mm wide & 4 mm thick
68S/F of glass strips for flooring.40mm wide & 4 mm thick
69Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick b ts with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
70Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work.
71P/F of Aluminium sheet 26 gauge including supply of all material, labour T&P required for proper completion of the work.
72Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
73Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
74Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
75Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
76Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
77Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gaugewith 0.5 mm dia wire and 1.4 mm wide aperture with matching & wood beading
78Providing and fixing fly proof galvanized M.S. wire gauge to windows and lerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading
79Providing and fixing wire gauge shutters using With ISI marked stainless steel butt hinges required size of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35mm thick shutters With ISI marked stainless steel butt hinges of required size. Second class teak wood
80Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood
81Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.
82Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia
83Expension joint teatment with 1.02 mm thick aluminium sheet and 4 cm thick bitumastic sheet with hot bitumen of approved aulity. (As per Rate analysis & specification attached) HORIZONTAL EXPANSION JOINT
84Providing & fixing aluminium sheet ,1.02 mm thick for Vertical expansion joint work including labour and all materials etc . Powder coated aluminium (minimum thickness of powder coating 50 micron) VERTICAL EXPANSION JOINT
85Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
86Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
87Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
88Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete.
89Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
90Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform.
91Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick
92Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts.
93Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
94Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
95Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
96Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
97Supplying, stacking and Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling. With road roller/ hand roller
98Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge 40/50 mm compacted thickness with bitumen of grade CRMB-60 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPHcapacity
99S/F of Distribbuting of Rubber & Sand in Artificial Turf proper completion of the work . as per specification,as per directions of Engineer-in-Charge
100Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. For new work (two orr more more coat )
101Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
102Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
103Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). DSR-16.75
104Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade ‘A’ sealing compound conforming to IS: 1834 DSR- 16.46.1
105Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately
106Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
107Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, arryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
108Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked White solid plastic seat and lid
109Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
110Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.
111Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm
112Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Semi rigid pipe . 32 mm dia
113Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Semi rigid pipe . 40 mm dia
114Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
115Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 450x300x150 mm
116Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
117Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
118Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Range of Three half stall urinals with 10 litre P.V.C. automatic flushing cistern
119Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required c) Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern
120Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement:2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
121Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore
122Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.
123Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore
124Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. ( for sink) a) 15 mm nominal bore
125Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
126Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
127Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer- in-charge.
128Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.
129Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
130Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
131Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. (a) 160mm diameter
132Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 110 mm O.D.
133Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 75 mm O.D.
134Haunching of SWR pipe 90mm or 110mm or 160mm with pcc 1:5:10 cement concrete ( 1 cement:2 coarse sand:4 stone grit) AR
135Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : hubless centrifugally cast (spun) iron epoxy coated inside & outsides as per IS:15905(a) 100mm inlet & 100mm outlet.
136Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : hubless centrifugally cast (spun) iron epoxy coated inside & outsides as per IS:15905 (b) 100mm inlet & 75mm outlet.
137Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia
138Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. Single soakted pipes 110 mm
139Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
140Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend
141Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
142Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.
143Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 75 mm
144Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 110 mm
145Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 75/90 mm
146Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm
147Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 75x75x75 mm
148Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 110x110x110 mm
149Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 75 mm
150Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 110 mm
151Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
152Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
153Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
154Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal pipes
155Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal pipes
156Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25mm dia nominal pipes
157Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 20mm dia nominal bore
158Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 25mm dia nominal bore
159Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 32mm dia nominal bore
160Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 40mm dia nominal bore
161Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 50mm dia nominal bore
162Providing and fixing gun metal gate valve with wheel of approved quality.(screwend) 20mm dia nominal bore
163Providing and fixing gun metal gate valve with wheel of approved quality.(screwend) 25mm dia nominal bore
164Providing and fixing gun metal gate valve with wheel of approved quality.(screwend) 32mm dia nominal bore
165Providing and fixing gun metal gate valve with wheel of approved quality.(screwend) 40mm dia nominal bore
166Providing and fixing gun metal gate valve with wheel of approved quality.(screwend) 50mm dia nominal bore
167Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
168Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc.
169Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m depth , Pipes 80 mm to 300 mm diameter
170Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered). Depth not exceeding 1.5 meter
171Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes
172Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete 250 mm. dia. RCC Pipes
173Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of SW pipe pipes including bed concrete as per standard design150 mm. dia.
174Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of sw pipes pipes including bed concrete as per standard design 250 mm. dia.
175Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:1.5:3 mix (1 cement :1.50 coarse sand :3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 15 (i) For Sewer Line
176Extra for depth for manholes:Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 15
177Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coar se sand) RCC top slab with 1:1.5:3 mix (1 cement :1.50 coarse sand :3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 15(i) For Sewer Line
178Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 15
179Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): With common burnt clay F.P.S. (non modular) bricks of class designation 15
180Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m With common burnt clay F.P.S. (non modular) bricks of class designation 15
181Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design. With 20 x20 mm square bar .:
182Providing and fixing C.I. tee at the inlet and outlet of septic tank.
183Providing & fixing 75mm dia vent pipes.
184Providing & fixing of 75mm dia cast iron terminal guard.
185Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D- 2.5, Rectangular shape 600x450 mm internal dimensions
186Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter .
187Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -2.5- Circular shape 450mm internal diameter .
188Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 15
189Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 80 mm nominal dia Pipes
190Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 50 mm nominal dia Pipes
191Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 32 mm nominal dia Pipes
192Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40mm nominal bore.
193Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50mm nominal bore.
194Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80mm nominal bore.
195Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix ( 1 cement : 1.50 coarse sand : 3 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 15
196Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 15
197Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Dumb bell with central bulb (180 mm wide, 8 mm thick)
198Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
199Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm For horizontal surface one coat @1.10 kg per sqm.
200Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually.
201Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire& labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
202Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
203Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge.
204Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
205Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge.
206Supply of 110mm dia plain PVC.(6kg/sqcm) pressure.
207Supply of 110mm dia sloted PVC (6kg/sqcm) pressure.
208Supply of P.V.C. soket 125mm dia.
209Supply of end cap 110 mm dia.
210Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of streta complete item. 30 metre B.G.L.
211Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of streta complete item. Beyond 30 metre.
212Supply & fixing of nylon jalli around the slotted pipe complete as required.
213Lowering of 110mm dia Rogid P.v.c. pipe in bore hole including cutting jointing etc. complete.
214Providing & packing of coarse sand around the P.v.c.pipe.
215Supply of 32mm dia G.i.pipe B class with required fitting. ( SOR Aligarh - 2018 SI No 12 Ch- 23 )
216Supply of India marka - II hand pump ISI marked with cylinder & connecting rods
217Installation of India marka - II hand pump over the bore hole as per direction of E/I
218Development of bore by manual labour till discharge of free from turbity complete item.
219Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm ht., in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge DSR LANDSCAPING & HORTICULTURE-2020 (5.40)
220Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge. DSR LANDSCAPING & HORTICULTURE-2020 (8.31)
221Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-incharge. DSR LANDSCAPING & HORTICULTURE-2020 (6.12)
222Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. DSR LANDSCAPING & HORTICULTURE-2020 (7.69)
223Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. DSR LANDSCAPING & HORTICULTURE-2020 (6.31)
224Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
225Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
226Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
227Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required.
228Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
229Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
230Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
231Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
232Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
233Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
234Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
235Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
236Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
237Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
238Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 MM
239Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch
240Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 2 Way 5/6 amps switch
241Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. DATA outlet
242Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
243Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV socket outlet
244Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ45 socket cat 6 with shutter
245Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
246Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
247Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
248Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
249Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
250Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
251Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
252Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
253Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
254Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
255Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
256Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
257Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
258Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
259Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
260Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
261Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
262Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
263Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
264Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
265Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 12), Double door
266Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
267Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB
268Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole
269Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
270Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
271Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6-32Amp C Curve
272Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 Amp 4PMCB
273Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amp
274Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Three poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent.
275Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent.
276Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
277Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
278Supply and laying of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode including connection / terminating with nut ,bolt spring washer etc. jointing shall be done by overlaping and with 2 sets of brass nut bolt&spring washer spaced at 50mm)
279Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. without charcoal/ coke and salt as required.
280Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
281Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
282Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent.
283Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent.
284Supply of 26W Smart Bright Linear provides an extremely durable and high efficacy yet cost effective linear solution surface mounted and suspended applications like offices, retail stores, metro stations, etc. similar to Philips SP095V LED26S 865 W7L120 PSU WH or equivalent.
285Supply of 40W Smart Bright Linear provides an extremely durable and high efficacy yet cost effective linear solution surface mounted and suspended applications like offices, retail stores, metro stations, etc. similar to Philips SP095V LED40S 865 W7L120 PSU WH or equivalent.
286Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
287Supply and fixing of Exhaust -Fan 200mm Complète in all respect including supply of all material, labour T&P required for proper completion of the work.
288Supply of Pressure die cast housing LED bulkhead with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications. Similar to Philips Cat Ref. WT202W LED6S NW PSU S2 PC or equivalent.
289Supply & fixing of water tight-oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity/ transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24
290Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect
291Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 4CX6Sq.mm Cable
292Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 19884CX16Sq.mm Cable
293Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX35Sq.mm Cable
294Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX50Sq.mm Cable
295Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX95Sq.mm Cable
296Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 19883.5CX150Sq.mm Cable
297Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX240Sq.mm Cable
298Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
299Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
300Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)
301Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62mm)
302Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
303Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
304Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
305Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
306Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
307Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia
308Supply, installation, testing, and commissioning of UPS system with following features 3 Phase Input & 3 Phase Output 10KVA UPS 1. High freq. PWM inverter using IGBT 2. Manual/Auto bypass switch3. SMF batteries to provide approx. 30 min backup time on IT load alongwith battery rack complete in all respect as per directed by E/I.
309MAIN L.T PANEL Design, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. INCOMMER :500Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-1 no., 160Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-2 no. 160Amp. 16KA FP Auto Changeover For Emmergency Condition , BUSBARS : 1 Nos. 400 Amp FP busbars of aluminium alloy as per SLD., OUTGOING :32Amp. 10KA FP MCB 4 No. 63Amp. 10KA FP MCB 4 No. 63Amp. 10KA FP MCCB 4 No. 100Amp. 10KA FP MCCB 4 No. 160Amp. 10KA FP MCCB 4 No.,INSTRUMENTS : 2 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers with RS 485 port. 2 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 2 Sets auto trip indicating lamp .
310Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for alltesting required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C) 12 -15 watt
311Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for alltesting required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C) 18 watt
312LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 12 -15 watt
313Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 18 -22 Watt
314Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 36 Watt
315Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 40 Watt
316Supplying installation testing and commissioning of 450mm sweep 1500 RPM heavy Duty Exhaust Fan
317Supply and fixing of LED Tube Light with heavy duty Metal Box type Mirror Light fitting 10 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect
318Supply and fixing of wall bricket 10 watt LED bulb Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect
319Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 4 way, Double door TPN MCBDB
320Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
321Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
322Supplying and fixing 40 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole
323Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
324Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects.
325Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
326Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 150 sq. mm 3-1/2 core
327Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kv grade as required.150 sq. mm 3-1/2 core
328Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Cubical Panel Board ( MCCB Type) Main L.T. Panel (Meter Panel Board) Incoming : One (1) No.200Amp. MCCB-1No., Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.200 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 100 Amp. MCCB- 1 No. 63 Amp. MCCB- 3 No. Or outgoing as per site requirment(AS/SLD)
329Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 350 mm dia
330Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 350 mm dia Rocky strata including Boulders , 350 mm dia
331Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in- charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm.
332Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
333Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
334Supplying & Installation of suitable Hp submersible pump B.S or K.S.B or equivalent make with finolex cable 1x3x2.5 squmm(upto 75mtr) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as MCB of 0-25Amp (Havell or Indocopp or MDS make), Volt & Ampere meter (AE make), single phase preventer (Minilac or VSP -1 make) starter (L&T or BCH make) etc of approved make, 40mm HDPE Pipe (25 mtr) and all accessories complete as per requirement of site.NOTES , a) Contractor shall include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual. b) Contractor to select suitable HP of pumps . c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in overhead domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps.
335(A) Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520.(C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, confirming to IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 450 lpm at 35 m head
336Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required:25 mm dia
337Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 100 mm dia
338Supplying & fixing single headed internal yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal
339Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia
340Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required:
341Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia
342Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal
343Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
344Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal
345Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
346Providing & fixing of pressure switch in M.S. pipe line including connection etc as required.
347Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
348Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required.
349Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone cenclosed in a M.S. box(16 SWG)/ABS box with break glass in front etc. complete as required.
350Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
351Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
352Supply and fixing of following sizes of medium class PVC conduit alongwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25 mm
353Supplying, installation, testing & commissioning of main control and indicating panel made out SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, inte 6 Zone panel for fire alarm systemrconnections etc complete as required. 100 Watt amplifier racks suitable for operation on 230V AC/24VDC supply confirming to IEC-268-3 complete with all accessories as required-2 Nos.(one to act as standby) Talk back master station with LED PTT(press to talk) push button for operation on 230V AC/24 V DC supply confirming to IEC-268 for simplex mode of operation/communicat Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required-1set. ion suitable for 20 Nos. talk back unit-1 set.Amplifier change over switch for inter changing amplified-1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch,fuse,visual indications etc. complete as required-1 No. Gooseneck microphone with stand and ON/OFF switch-1 No.Main ON/OFF switch,fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required-1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free bateries-1 set.
354Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
355Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
356Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
357Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 80 mm dia
358Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 100 mm dia
359Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal
360Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 80 mm dia
361Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia
362Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia
363Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal
364Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal
365Supplying & fixing of Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe
366Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
367Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
368Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. Make : Standard/Lifeguard or EQ.
369Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering).(Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor).
370Supplying and fixing of Self Glow Exit signage for stairs and exits made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site..(MAKE : Agni Suraksha (ASES) / Securiton-aka /System Sensor)
371Supplying and fixing of Fire man axe. Make :- Agni Suraksha (ASES) or EQ
372Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make :- Agni Suraksha (ASES) or EQ.
373Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of : Incomer:-a) 63 amp 4 Pole MCCB, 50Hz with breaking capacity 10KW. b)One Volt meter (0-500 V) with selector switch.c) Ammeter (0-63 Amps.) with selector switch & CTs. - 1 Setd) Set of 3 phase indication lamps - 1 Set ,e) Set of Al bus bar 200 Amp 4 strip - 1 Set f) Selector switch for local/remote, auto/manual/off operation ON/OFF indication lamp etc. - 1 Set Outgoing:-2 x 63 Amps FP MCCB (25 KA) 1 x 40 Amps FP MCCB (25 KA)with Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.
374Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
375The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification.interlocking, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification.Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention as mention in BOQ. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA.INCOMING 1 Nos. 400 Amp FP MCCB , 1 Nos. 125 Amp ACB , BUSBARS 1 Nos. 500 Amp TPN busbars of aluminium alloy as per SLD. AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's. Load Management through PLC Contactor for Load Management System . Buscoupler switching. Interlocking. OUTGOING , 4 Nos. 125 Amp TP MCCB 4 Nos. 63 Amp TP MCB , 3 Nos. 40Amp TP MCB , INSTRUMENTS: 3 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers. 3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 3 Sets auto trip indicating lamp . Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams.
376EXTERNAL LIGHT FEEDER PILLAR :Supply installing testing & commissioning of out door type street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below.Incoming: 63 Amp. 10 KA FP MCCB - 1 No. ,Suitable contractor and timer for down & dusk , 100 Amp. TPN Alu. Bus bar . Outgoing, 25 Amp. 10KA DP MCB - 6 No.
377Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.
378Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.(Ed e Plus LED Streetli ht)
379Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
380Supply installing testing & commissioning of LED Bollard offers a high level of durability with high impact resistance. It is easy to install, comes with ingress protection and provides comfortable soft lighting BGBOL 605 9W LED LED BOLLARDS
381Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 2 X 6 sq. mm
382Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 10 sq. mm
383Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 50 sq. mm
384Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 120 sq. mm
385Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 150 sq. mm
386Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Upto 35 sq. mm
387Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Above 95 sq. mm and upto 185 sq. mm
388Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
389Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
390Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
391Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
392Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
393Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
394Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 Core 6 sq.mm
395Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 50 sq. mm
396Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 120 sq. mm
397Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 150 sq. mm
398g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays , supports, lugs, thimble and other accessories etc. as required. h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connectioninterconnection, etc. as required.COPPER WOUND 27 KVA elec dsr 17.1
399S/F Aluminum Frame Green Chalk Board - Sizes 2.4x1.2 Available | Modern Rectangular Design For Classroom & Education Surface Finish Matte FinishSize Standard Color Green Features Strong quality, Work Copletion as Per Direction Of E/I. (MR.)
400Supplying fixing and commissioning of SILENT (Canopy design) water cooled DG Set with electronic governer with one Diesel Engine with rated capacity (mentioned below) at 0.8 P.F. 1500 RPM, 4 stroke multi-cylinder coupled to brush less type 415 volts 50 cycle/ second self exited alternator completed with cushy pads. Domestic silencer exhaust pipe complete with Alternator auxiliaries, Radiator, 24 volts chargeable battery including initial charging of batteries. suitable for synchronizing complete as per specification.125 KVA
401Providing, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type outdoor copper wound 11 kV/ 433 Volts Step Down Transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed and Off Load Tap Changer continuously rated for a full temperature rise in oil not exceeding 40 deg. C at maximum ambient temp. Of 50 deg. C complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 1180 LEVEL 2 standards OFF load tap changing range steps -10% to 5% on H.V in steps of 2.50% .and L.V. for variation should be provided The H.V. shall be connected delta & secondary with star connection. The transformer should have cable-end boxes on H.T. side & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers. Losses As per IS 1180 LEVEL-2. Cose rvator with plain oil level gauge and oil drain plug 1nos., Top filter valve 1 Nos.,Bottom filter-Cum-drain valave 1Nos.. Rating and diagram plate 1nos.,Earthing Terminals 2Nos.,Thermometer pockets 1Nos. Lifting Lugs 2/4 Nos.Air release plug 2/4 Nos. ,Bi-directional rollers 4Nos.,Jacking pads 1Nos. Presure relese valve 1Nos. ,Separate Bare LV neutral 433V , Detachable/Fixed type radiators 1Nos. Oil temperature indicator 1Nos. ,Winding temperature indicator 1Nos. Marshlig Box single window 1No., Double flot buchholz's relaywith alarm and trip contact. COPPER WOUND 200KVA 11/.433V
4023 Phase Input & 3 Phase Output 10KVA UPS Supply, installation, testing, and commissioning of UPS system with following features 1. High freq. PWM inverter using IGBT 2. Manual/Auto bypass switch3. SMF batteries to provide approx. 30 min backup time on IT load alongwith battery rack
403Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 Run of Cable
404Supplying, installing, testing and commissioning of 24 port CAT6 jack panel loaded as per the connections required in jack panel.
405Supplying, installing, testing and commissioning of I/O(Information outlet ) for CAT6 Cable termination
406Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts.
407Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus
408Supply, Installation, Testing & Commissioning of 4MP IP Network TDN Low-Light IR Rugged Dome Camera, 1/3\\" CMOS, 4 MP @ 25fps or better, triple stream, Min. Illumination required 0.01 lux @ F1.6 (color), 120dB True WDR with Scene Adaptive Control, Min. Pixels 2688 × 1520, Shutter Speed 1/3 - 1,00,000; Adavance Video Compression technology such as H.265 & H.264 High Profile , Triple stream, 2.7–13.5 mm 5X motorized focus & zoom lens, BLC, HLC, 3DNR, Minimum Edge Intelligence Video Analytics : Motion Detection, Video Tampering, Face Detection, SD Card Error, SD Card Capacity Warning, Audio Detection, Object Abandoned, Object Missing, Tripwire/Intrusion; Loitering; Privacy Mask, 4 IR LEDs Smart IR with upto 50m IR distance, AES-256, SSH/Telnet closed, PCI Data Security Standard compliance; Dual channel Audio G.711a/ G.711Mu/ AAC/G.726, 128GB SD card support, Alarm: 2 In/ 1out, PoE Class 4 (802.3 at) and 12V DC, support aux. power supply of 2W , 12VDC for powering low power devices such as strobe light/hooter, IP 67, IK 10 vandal proof, Die-Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G and Q compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55032) , FCC Part 15 & RoHS compliant. Make: Mobotix/ Avgilion/Flir/Axis/Honeywell/Bosch
409Supply, Installation, Testing & Commissioning of 4MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/3\\" CMOS, 4 MP @ 25fps or better, triple stream, Min. Illumination required 0.01 lux @ F1.6 (color), 120dB True WDR with Scene Adaptive Control, Min. Pixels 2688 × 1520, Shutter Speed 1/3 - 1,00,000; Adavance Video Compression technology such as H.265 & H.264 High Profile , Triple stream, 2.7–13.5 mm 5X motorized focus & zoom lens, BLC, HLC, 3DNR, Minimum Edge Intelligence Video Analytics : Motion Detection, Video Tampering, Face Detection, SD Card Error, SD Card Capacity Warning, Audio Detection, Object Abandoned, Object Missing, Tripwire/Intrusion; Privacy Mask, 4 IR LEDs Smart IR with upto 60m IR distance, AES-256, SSH/Telnet closed, PCI Data Security Standard compliance, Hardware chipset for private key; Dual channel Audio G.711a/ G.711Mu/ AAC/G.726, 128GB SD card support, Alarm: 2 In/ 1out, Long Distance 3X PoE support upto 300m (300m @100Mbps) , PoE Class 4 (802.3 at) and 12V DC,support aux. power supply of 2W ,12VDC for powering low power devices such as strobe light/hooter, IP 67, IK 10 vandal proof, Die-Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G and Q compliant, UL, CSA 60950-22, CE (EN50130-4 & EN 55032) , FCC Part 15 & RoHS compliant. Make: Mobotix/ Avgilion/Flir/Axis/Honeywell/Bosch
410SITC of 32 channel Network Video StoragE NVR suitabe to access data from any remote location including backup drive for 30days.
411Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1 No.of 55” LED Display - Complete as per specifications & preferred make. Make: SONY/Samsung/LG
412Supply, Installation, Testing & Commissioning of LCD CCTV Joystick Keyboard, LAN POE Connection, 3-Axis Propotional Control, 20 Functional Keys, UL, CE, FCC Listed, Make: Mobotix/ Avgilion/Flir/Axis/Honeywell/Bosch
413Supplying, installing, testing and commissioning of HDMI to HDMI Cable.
414Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
415Supply installing testing & commissioning of out door type junction box, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required suitable for mounting of 2 nos. 5/6Amp Switch & Sockets. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57281774
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 19.86 Crore
LAST DATE 29-09-2026
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Tender for Construction Work Of Chief Minister Model Composite Vidhyalaya (Pre-Primary To Class 12Th) At Vikas Khand-R Ur Sangramgarh, Villege-R Ur Bawli, Tehsil-Lalganj, Distt- Pratapgarh.
Basic Detail
Tender No 1633/L-11/176 Dated 21.08.2026
Bidding Type Tender
Location
City Pratapgarh
State Uttar Pradesh
Key Dates
Publish Date 01 Sep 2026
Submission Date 29 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 19.86 Crore
Tender Fee 8850
EMD 39.73 Lakhs
Exemption Available
Document List
82e9cd4e-5c6d-4835-b297-8e11bbacc973.html
BOQ_2220921.xls
F.pdf
T.pdf
Tendernotice_1 (68).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

82e9cd4e-5c6d-4835-b297-8e11bbacc973.html

xls

BOQ_2220921.xls

pdf

F.pdf

pdf

T.pdf

pdf

Tendernotice_1 (68).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders