Tender For Construction Of Toilet Building And Drilling Of Bore Well At Water Treatment Plant
Tender Value
17.80 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
0 days left
EMD
17800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Toilet Building And Drilling Of Bore Well At Water Treatment Plant
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. |
| 2 | Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the departmental officers. |
| 3 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means |
| 5 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. |
| 6 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means |
| 7 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 8 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be rovided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 9 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 10 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 11 | Upto Basement |
| 12 | Ground Floor |
| 13 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 14 | Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 15 | Upto Basement |
| 16 | GROUND FLOOR |
| 17 | Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 18 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 19 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 20 | Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification. |
| 21 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 22 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) |
| 23 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 24 | Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 25 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 26 | White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. |
| 27 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 28 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 29 | 110mm dia pipe |
| 30 | 75mm dia pipe |
| 31 | Supplying and fixing of 1000 litters capacity PVC tank of approved quality including cost of all materials like tank fittings, lead .lift, errection etc complete. PWD SOR PGNO:50 |
| 32 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 33 | 25mm Gun Metal Valve |
| 34 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 35 | SD Tap |
| 36 | Pillar Tap |
| 37 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply Above ground level. |
| 38 | 25mm dia Pipe |
| 39 | Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements |
| 40 | Coupler |
| 41 | 25mm Pipe |
| 42 | Elbow |
| 43 | 25mm Pipe |
| 44 | 25mm Pipe |
| 45 | 25mm Pipe |
| 46 | End Cap |
| 47 | 25mm Pipe |
| 48 | Reducer |
| 49 | 25 mm x 20 mm |
| 50 | Reducer Tee |
| 51 | 25 mm x 20 mm |
| 52 | 32 mm x 25 mm |
| 53 | Reducer Elbow |
| 54 | 25 mm x 20 mm |
| 55 | Jet Nipple |
| 56 | 25mm Pipe |
| 57 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 58 | PVC Elbow |
| 59 | 110mm dia |
| 60 | 75mm dia |
| 61 | PVC Elbow with Door |
| 62 | 110mm dia |
| 63 | 75mm dia |
| 64 | PVC Tee |
| 65 | 110mm dia |
| 66 | 75mm dia |
| 67 | PVC Tee with Single Door |
| 68 | 110mm dia |
| 69 | 75mm dia |
| 70 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 71 | Supplying and fixing in position of Indian Make White/Colour glazed earthen ware lipped mouth Flat Back Urinal of best approved quality with G.I.Pipe connection to suitable length,32mm bell mouthed P.V.C connection ,15mm dia G.M.Wheel valve,fixing the urinal to the wall in position with necessary T.W.plugs ,clamps,screws, shellac etc.,including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I.pipe connection and wheel valve ,painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage complete, complying with standard specifications. - White Colour |
| 72 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 73 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 74 | Supplying and fixing in position Manhole Cover SFRC of 60 X 60cm in size in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), of best approved quality and as per standard specifications etc.,complete. |
| 75 | Conducting Geophysical survey, quality and quantity test and transportation charges etc, (This includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist) |
| 76 | Drilling of 150mm dia vertical bores in hard rock formation to any required depth as directed by the departmental officers including labour charges for inserting casing pipe, assembling in the drilled hole, including welding the joints if necessary grouting the casing pipe etc, and including transportation charges for the rig and supporting vehicles from one place to another place. |
| 77 | Supply and delivery of unplasticised ribbed screen PVC casing pipe of the 200mm dia in 3m length with screwed and socket end and centering guide for every 15m length of pipes as per IS / 12818 / 1992 and as amended from time to time to suit the borewell upto 80m depth (C.S) with ISI marking including, loading, unloading , freight, stacking and transit insurance charges etc, complete. |
| 78 | Supply and delivery of unplasticised ribbed screen PVC casing pipe of the 150mm dia in 3m length with screwed and socket end and centering guide for every 15m length of pipes as per IS / 12818 / 1992 and as amended from time to time to suit the borewell upto 80m depth (C.S) with ISI marking including, loading, unloading , freight, stacking and transit insurance charges etc, complete. |
| 79 | Supply and delivery of clear water vertical wet type submersible pump ( 20x100) conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % TWAD SOR Pg.No.100 |
| 80 | Supply and delivery of Single Phase Panel Board - Star Delta with two level Guard and auto start suitable for Submersible pumpsets and accessories including all fittings suitable for Submersible pump sets.Panel Board should be provided as per specification. Rates inclusive of Packing, Loading, Freight, Unloading, Stacking, Transit and Insurance charges etc, complete. |
| 81 | Supply and delivery finishing of HDPE Pipe 32 mm including loading, unloading transportation and labour charges for finishing of pipe and specials for pile connection works including charges as directed by department., TWAD SOR Pg. No. 30 |
| 82 | Labour charges for the erection of submersible pump set in bore well/open well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventer, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. |
| 83 | supply and fixing of following water supply speicals including cost and conveyance of materials and labour charges etc.,complete |
| 84 | 32mm GI Gate valves |
| 85 | 32 mm HOSE pipe |
| 86 | 32mm GI pipe |
| 87 | M.S Clamp Set |
| 88 | 32mm flange |
| 89 | 150mm Bore Cover |
| 90 | 3.5core 25 sqmm Cable |
| 91 | 3 core 4 sqmm Cable |
| 92 | 20mm PVC Pipe |
| 93 | Construction of brick work pedestal for Kiosk box using country bricks in cm 1:5 mix,size of 0.75mx0.45x1.40m height ,including necessary earth work filling sand, PCC 1:4:8 using 40mm HBG metal,plastering with cement mortar 1;5 mix to 12mm thick and painting two coats over one coat of white washing fixing Kiosk boxover the pedestal etc completed as per standard specification |
| 94 | Supply and fixng of TNEB Meter Board suitable for 3 Phases 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1 1/2\\" x 1 1/2\\" x 1/4\\" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 200A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1\\" x 1/4\\" with inter connection of EB meter to fuseunits by 19/16 PVC insulated copper wire with earth connection complete SD 131 |
| 95 | Earthing as per P.W.D standard with an earth electrode of 2mtr class \\"B\\" GI pipe of dia not less than 32mm complete with necessary masonry work as SD 234 |
| 96 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) 14 (SD 23) |
| 97 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point (SD 38) |
| 98 | Supply anf fixing of 18W 4 Feet LED Fitting with LED Fitting including all Cost and Charges etc., complete complying with standard specification. PWD SOR Pg. No. 121 Sl. No.15 M-1272 |
| 99 | supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with 1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .. SD 447 |
| 100 | Supplying and Delivery fixing of 1.20 x 0.30 meter Dia AC Cement Rings of approved quality including cost of all materials lead .lift, errection etc complete. |
| 101 | Supply and Fixing of CCTV Camera with Specification of Dahua- HAC-HFW 1100DP-B-0600 720P 1 Mega Pixel Analog High Definition camera, outdoor-25/30 fps@720P,1/2.9\\" 1 Megapixel CMOS, 50m IR,ICR, 6mm Lens optional, IR Bullet Dahua - Channel - AHD, High Video Quality on HD 1080N, Transmit Video Signal, audio signal & Dual way data communication signal over one coaxial cable, HD Video transmission without Video quality loss & delay, extremely, long transmission distance (300), as directed by Departmental Executive Engineer. |
| 102 | Supply and Installing 4MP IP Bullet / Dome Camera. (M-2806) |
| 103 | 29\\" Led TV for display |
| 104 | Network video recorder for CCTV 4 channel (M-2195) |
| 105 | Armoured LAN & CCTV Cable CAT-6 (M-2184) |
| 106 | POE Switches for CCTV IP camera 4 Port (M-2192) |
| 107 | Hard disk for NVR (2TB) (M-2220) |
| 108 | Rack With Accesssories -4U (M-2225) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender