Bids Are Invited For Custom Bid For Services - Repair Rate Contract For Routine/ Repair Of Stp System Onboard In Ships For A Period Of One Year And Extendable For Two More Years At Nd (Kar) - Overhaul Of Macerator Pump Iaw Oem Manual , Renewal Of Macerato
Tender Overview
Project Description
Bids Are Invited For Custom Bid For Services - Repair Rate Contract For Routine/ Repair Of Stp System Onboard In Ships For A Period Of One Year And Extendable For Two More Years At Nd (Kar) - Overhaul Of Macerator Pump Iaw Oem Manual , Renewal Of Macerator Pump , Overhaul Of Macerator Pump Motor Iaw Oem Manual , Renewal Of Macerator Pump Motor , Overhaul Filling Pump As Per Oem Manual , Renewal Of Filling Pump , Overhaul Of Filling Pump Motor As Per Oem Manual , Renewal Of Filling Pump Motor , Overhaul Of Obd Pump As Per Oem Manual , Renewal Of Obd Pump , Overhaul Of Obd Pump Motor As Per Oem Manual , Renewal Of Obd Pump Motor , Repair Of Obd Pump Starter , Renewal Of Obd Pump Starter , Overhaul Of Imo Pump As Per Oem Manual , Renewal Of Imo Pump , Overhaul Of Imo Pump Motor As Per Oem Manual , Renewal Of Imo Pump Motor , Repair Of Imo Pump Starter , Renewal Of Imo Pump Starter , Overhaul/ Repair Of Three Way Valve As Per Oem Manual , Renewal Of Three Way Valve , Overhaul/ Repair Of Dosing Pump , Renewal Of Dosing Pump , Renewal Of Dosing Line , Filling Up Of Disinfectant Fluid (H202 Solution) , Renewal Of Rubber Compensator Fitted Between Lines Per Plant , Serviceability Checks Of Solenoid Valve For Sea Water Supply , Renewal Of Solenoid Valve For Sea Water Supply , Serviceability Checks For Sensors For Filling Water Pump , Renewal Of Sensor For Filling Water Pump , Serviceability Checks / Repair Of Float Switches Fitted In Collection Tank , Renewal Of Float Switches Fitted In Collection Tank , Serviceability Checks/ Repair Of Float Switches Fitted In Treatment Tank , Renewal Of Float Switches Fitted In Treatment Tank , Inspection, Pressure Testing/ Leak Testing Per System Pipelines Including Overload Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter. , Repair/ Renewal Of Pipeline Including Overboard Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter , Repair/ Reconditioning Of Blower With Motor , Serviceability Checks/ Repair Of Pressure Sensor Fitted In Collection Tank For Remote Indication Of Level In Dchq , Serviceability Checks Of Electrical Equipment / Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Electrical Equipment/ Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Pressure Sensor For Remote Indication Of Tank Level In Dciq , Overhauling / Functionality Checks Of Of Electrical Control Panel (Plc Based) And Repair Any Defect On Electrical Control Panel , Renewal Of Electric Component Of Electric Control Panel , Repair/ Renewal Of Electrical Cable And Accessories Including Earthing , Inspection And Calibration Of Instrumentation Per Plant , Renewal Of Pressure Gauges For Obs Pumps , Endurance Test And Effluent Test Of S Les Of Stp For Bod And Tss On Completion Of Major Repairs As Proposed By Ss/ Every Six , Renewal Of Various Tallies Per Plant , Impeller For Macerating / Transfer Pump S8 1 , Mechanical Seal For Macerating / Transfer Pump S8 1 , Wear Plate For S81 , Maintenance Kit For Dosing Pump , 2-Way Valve 1 24V Ac Gas F Solen , Pressure Regulator , Actuator For 3-Way Valve 2 , Floating Level Sensor Mobrey , Level Probe Inox 316L, Side Mounting , Ecomar Cover Board Pro14 R3 For Ecomar , Actuator For Rotary Valve Ea0130 , Flanged Rubber Joint Dn25 , Flanged Rubber Joint Dn50 , Flanged Rubber Joint Dn65 , Flanged Rubber Joint Dn80 , Pcb Board Pro14/02 , Exp14/0A Rev. 1 Board For Ecomar , Transformer 100Va Prim: 230/400/415-Sec: 12/24V , Transf. 400Va Prim: 380-400-415-440V Sec.230V , Fuse 2A (5X20) , Fuse 2A (10X38) , Fuse 1A (10X38) , Motor Circuit Breaker 2.5-4A , Motor Circuit Breaker 9-14A , Led 24V Ac/Dc , Contactor Lc1D18B7 18A 24Vac 50/6 , Contattore Lc1D09B7 9A 24Vac 50/6 , Contactor For Ecomar 4P 24V 50/60Hz , Relay 24Vac 40.52.8.024 , Flat Cable 20 Poles , Auxiliary Contactor Ladn20 , Measure And Control Relay 208-480Vac , Switching Power Input 24Vac Output 12/24Vdc
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Overhaul of macerator pump iaw OEM manual | Overhaul of macerator pump iaw OEM manual |
| 2 | Renewal of macerator pump | Renewal of macerator pump |
| 3 | Overhaul of macerator pump motor iaw OEM Manual | Overhaul of macerator pump motor iaw OEM Manual |
| 4 | Renewal of macerator pump motor | Renewal of macerator pump motor |
| 5 | Overhaul filling pump as per OEM manual | Overhaul filling pump as per OEM manual |
| 6 | Renewal of filling pump | Renewal of filling pump |
| 7 | Overhaul of filling pump motor as per OEM manual | Overhaul of filling pump motor as per OEM manual |
| 8 | Renewal of filling pump motor | Renewal of filling pump motor |
| 9 | Overhaul of OBD pump as per OEM manual | Overhaul of OBD pump as per OEM manual |
| 10 | Renewal of OBD pump | Renewal of OBD pump |
| 11 | Overhaul of OBD pump motor as per OEM manual | Overhaul of OBD pump motor as per OEM manual |
| 12 | Renewal of OBD pump motor | Renewal of OBD pump motor |
| 13 | Repair of OBD pump starter | Repair of OBD pump starter |
| 14 | Renewal of OBD pump starter | Renewal of OBD pump starter |
| 15 | Overhaul of IMO pump as per OEM manual | Overhaul of IMO pump as per OEM manual |
| 16 | Renewal of IMO pump | Renewal of IMO pump |
| 17 | Overhaul of IMO pump motor as per OEM manual | Overhaul of IMO pump motor as per OEM manual |
| 18 | Renewal of IMO pump motor | Renewal of IMO pump motor |
| 19 | Repair of IMO pump starter | Repair of IMO pump starter |
| 20 | Renewal of IMO pump starter | Renewal of IMO pump starter |
| 21 | Overhaul/ repair of three way valve as per OEM manual | Overhaul/ repair of three way valve as per OEM manual |
| 22 | Renewal of three way valve | Renewal of three way valve |
| 23 | Overhaul/ repair of dosing pump | Overhaul/ repair of dosing pump |
| 24 | Renewal of dosing pump | Renewal of dosing pump |
| 25 | Renewal of dosing line | Renewal of dosing line |
| 26 | Filling up of disinfectant fluid (H202 solution) | Filling up of disinfectant fluid (H202 solution) |
| 27 | Renewal of rubber compensator fitted between lines per plant | Renewal of rubber compensator fitted between lines per plant |
| 28 | Serviceability checks of solenoid valve for sea water supply | Serviceability checks of solenoid valve for sea water supply |
| 29 | Renewal of solenoid valve for sea water supply | Renewal of solenoid valve for sea water supply |
| 30 | Serviceability checks for sensors for filling water pump | Serviceability checks for sensors for filling water pump |
| 31 | Renewal of sensor for filling water pump | Renewal of sensor for filling water pump |
| 32 | Serviceability checks / repair of float switches fitted in collection tank | Serviceability checks / repair of float switches fitted in collection tank |
| 33 | Renewal of float switches fitted in collection tank | Renewal of float switches fitted in collection tank |
| 34 | Serviceability checks/ repair of float switches fitted in treatment tank | Serviceability checks/ repair of float switches fitted in treatment tank |
| 35 | Renewal of float switches fitted in treatment tank | Renewal of float switches fitted in treatment tank |
| 36 | Inspection, pressure testing/ leak testing per system pipelines including overload discharge lines, flushing lines, IMO lines, lower end vent line, tank vent line, tank vent lines, gas indicator lines and PVC line per meter. | Inspection, pressure testing/ leak testing per system pipelines including overload discharge lines, flushing lines, IMO lines, lower end vent line, tank vent line, tank vent lines, gas indicator lines and PVC line per meter. |
| 37 | Repair/ renewal of pipeline including overboard discharge lines, flushing lines, IMO lines, lower end vent line, tank vent lines, gas indicator lines and PVC line per meter | Repair/ renewal of pipeline including overboard discharge lines, flushing lines, IMO lines, lower end vent line, tank vent lines, gas indicator lines and PVC line per meter |
| 38 | Repair/ reconditioning of blower with motor | Repair/ reconditioning of blower with motor |
| 39 | Serviceability checks/ repair of pressure sensor fitted in collection tank for remote indication of level in DCHQ | Serviceability checks/ repair of pressure sensor fitted in collection tank for remote indication of level in DCHQ |
| 40 | Serviceability checks of electrical equipment / sensors fitted in tanks (viz over pressure sensor etc) | Serviceability checks of electrical equipment / sensors fitted in tanks (viz over pressure sensor etc) |
| 41 | Renewal of electrical equipment/ sensors fitted in tanks (viz over pressure sensor etc) | Renewal of electrical equipment/ sensors fitted in tanks (viz over pressure sensor etc) |
| 42 | Renewal of pressure sensor for remote indication of tank level in DCIQ | Renewal of pressure sensor for remote indication of tank level in DCIQ |
| 43 | Overhauling / functionality checks of of electrical control panel (PLC based) and repair any defect on electrical control panel | Overhauling / functionality checks of of electrical control panel (PLC based) and repair any defect on electrical control panel |
| 44 | Renewal of electric component of electric control panel | Renewal of electric component of electric control panel |
| 45 | Repair/ renewal of electrical cable and accessories including earthing | Repair/ renewal of electrical cable and accessories including earthing |
| 46 | Inspection and calibration of instrumentation per plant | Inspection and calibration of instrumentation per plant |
| 47 | Renewal of pressure gauges for OBS pumps | Renewal of pressure gauges for OBS pumps |
| 48 | Endurance test and effluent test of samples of STP for BOD and TSS on completion of major repairs as proposed by SS/ every six | Endurance test and effluent test of samples of STP for BOD and TSS on completion of major repairs as proposed by SS/ every six |
| 49 | Renewal of various tallies per plant | Renewal of various tallies per plant |
| 50 | Impeller for macerating / transfer pump S8 1 | Impeller for macerating / transfer pump S8 1 |
| 51 | Mechanical seal for macerating / transfer pump S8 1 | Mechanical seal for macerating / transfer pump S8 1 |
| 52 | Wear plate for S81 | Wear plate for S81 |
| 53 | Maintenance kit for dosing pump | Maintenance kit for dosing pump |
| 54 | 2-WAY Valve 1' 24V Ac Gas F SOLEN | 2-WAY Valve 1' 24V Ac Gas F SOLEN |
| 55 | Pressure Regulator | Pressure Regulator |
| 56 | Actuator for 3-WAY Valve 2\\" | Actuator for 3-WAY Valve 2\\" |
| 57 | Floating Level Sensor Mobrey | Floating Level Sensor Mobrey |
| 58 | Level probe inox 316L, side mounting | Level probe inox 316L, side mounting |
| 59 | Ecomar cover board PRO14 R3 for ecomar | Ecomar cover board PRO14 R3 for ecomar |
| 60 | Actuator for rotary Valve EA0130 | Actuator for rotary Valve EA0130 |
| 61 | Flanged Rubber Joint DN25 | Flanged Rubber Joint DN25 |
| 62 | Flanged Rubber Joint DN50 | Flanged Rubber Joint DN50 |
| 63 | Flanged Rubber Joint DN65 | Flanged Rubber Joint DN65 |
| 64 | Flanged Rubber Joint DN80 | Flanged Rubber Joint DN80 |
| 65 | PCB Board PRO14/02 | PCB Board PRO14/02 |
| 66 | EXP14/0A REV. 1 Board For ECOMAR | EXP14/0A REV. 1 Board For ECOMAR |
| 67 | Transformer 100VA Prim: 230/400/415-SEC: 12/24V | Transformer 100VA Prim: 230/400/415-SEC: 12/24V |
| 68 | Transf. 400VA Prim: 380-400-415-440V SEC.230V | Transf. 400VA Prim: 380-400-415-440V SEC.230V |
| 69 | Fuse 2A (5X20) | Fuse 2A (5X20) |
| 70 | Fuse 2A (10x38) | Fuse 2A (10x38) |
| 71 | Fuse 1A (10x38) | Fuse 1A (10x38) |
| 72 | Motor Circuit Breaker 2.5-4A | Motor Circuit Breaker 2.5-4A |
| 73 | Motor Circuit Breaker 9-14A | Motor Circuit Breaker 9-14A |
| 74 | LED 24V AC/DC | LED 24V AC/DC |
| 75 | Contactor LC1D18B7 18A 24VAC 50/6 | Contactor LC1D18B7 18A 24VAC 50/6 |
| 76 | Contattore LC1D09B7 9A 24VAC 50/6 | Contattore LC1D09B7 9A 24VAC 50/6 |
| 77 | Contactor for ECOMAR 4P 24V 50/60Hz | Contactor for ECOMAR 4P 24V 50/60Hz |
| 78 | Relay 24VAC 40.52.8.024 | Relay 24VAC 40.52.8.024 |
| 79 | Flat Cable 20 Poles | Flat Cable 20 Poles |
| 80 | Auxiliary Contactor LADN20 | Auxiliary Contactor LADN20 |
| 81 | Measure and Control Relay 208-480VAC | Measure and Control Relay 208-480VAC |
| 82 | Switching Power Input 24VAC output 12/24VDC | Switching Power Input 24VAC output 12/24VDC |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender