Defence Government Departments Closing in 17 days TDR #57279437

Bids Are Invited For Custom Bid For Services - Repair Rate Contract For Routine/ Repair Of Stp System Onboard In Ships For A Period Of One Year And Extendable For Two More Years At Nd (Kar) - Overhaul Of Macerator Pump Iaw Oem Manual , Renewal Of Macerato

Issued by Government Departments · uttara kannada, Karnataka
Tender Value
5.81 Crore
Estimated cost
Bid Submission
21 Sep 2026
17 days left
EMD
17.43 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
uttara kannada → Karnataka
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are Invited For Custom Bid For Services - Repair Rate Contract For Routine/ Repair Of Stp System Onboard In Ships For A Period Of One Year And Extendable For Two More Years At Nd (Kar) - Overhaul Of Macerator Pump Iaw Oem Manual , Renewal Of Macerator Pump , Overhaul Of Macerator Pump Motor Iaw Oem Manual , Renewal Of Macerator Pump Motor , Overhaul Filling Pump As Per Oem Manual , Renewal Of Filling Pump , Overhaul Of Filling Pump Motor As Per Oem Manual , Renewal Of Filling Pump Motor , Overhaul Of Obd Pump As Per Oem Manual , Renewal Of Obd Pump , Overhaul Of Obd Pump Motor As Per Oem Manual , Renewal Of Obd Pump Motor , Repair Of Obd Pump Starter , Renewal Of Obd Pump Starter , Overhaul Of Imo Pump As Per Oem Manual , Renewal Of Imo Pump , Overhaul Of Imo Pump Motor As Per Oem Manual , Renewal Of Imo Pump Motor , Repair Of Imo Pump Starter , Renewal Of Imo Pump Starter , Overhaul/ Repair Of Three Way Valve As Per Oem Manual , Renewal Of Three Way Valve , Overhaul/ Repair Of Dosing Pump , Renewal Of Dosing Pump , Renewal Of Dosing Line , Filling Up Of Disinfectant Fluid (H202 Solution) , Renewal Of Rubber Compensator Fitted Between Lines Per Plant , Serviceability Checks Of Solenoid Valve For Sea Water Supply , Renewal Of Solenoid Valve For Sea Water Supply , Serviceability Checks For Sensors For Filling Water Pump , Renewal Of Sensor For Filling Water Pump , Serviceability Checks / Repair Of Float Switches Fitted In Collection Tank , Renewal Of Float Switches Fitted In Collection Tank , Serviceability Checks/ Repair Of Float Switches Fitted In Treatment Tank , Renewal Of Float Switches Fitted In Treatment Tank , Inspection, Pressure Testing/ Leak Testing Per System Pipelines Including Overload Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter. , Repair/ Renewal Of Pipeline Including Overboard Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter , Repair/ Reconditioning Of Blower With Motor , Serviceability Checks/ Repair Of Pressure Sensor Fitted In Collection Tank For Remote Indication Of Level In Dchq , Serviceability Checks Of Electrical Equipment / Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Electrical Equipment/ Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Pressure Sensor For Remote Indication Of Tank Level In Dciq , Overhauling / Functionality Checks Of Of Electrical Control Panel (Plc Based) And Repair Any Defect On Electrical Control Panel , Renewal Of Electric Component Of Electric Control Panel , Repair/ Renewal Of Electrical Cable And Accessories Including Earthing , Inspection And Calibration Of Instrumentation Per Plant , Renewal Of Pressure Gauges For Obs Pumps , Endurance Test And Effluent Test Of S Les Of Stp For Bod And Tss On Completion Of Major Repairs As Proposed By Ss/ Every Six , Renewal Of Various Tallies Per Plant , Impeller For Macerating / Transfer Pump S8 1 , Mechanical Seal For Macerating / Transfer Pump S8 1 , Wear Plate For S81 , Maintenance Kit For Dosing Pump , 2-Way Valve 1 24V Ac Gas F Solen , Pressure Regulator , Actuator For 3-Way Valve 2 , Floating Level Sensor Mobrey , Level Probe Inox 316L, Side Mounting , Ecomar Cover Board Pro14 R3 For Ecomar , Actuator For Rotary Valve Ea0130 , Flanged Rubber Joint Dn25 , Flanged Rubber Joint Dn50 , Flanged Rubber Joint Dn65 , Flanged Rubber Joint Dn80 , Pcb Board Pro14/02 , Exp14/0A Rev. 1 Board For Ecomar , Transformer 100Va Prim: 230/400/415-Sec: 12/24V , Transf. 400Va Prim: 380-400-415-440V Sec.230V , Fuse 2A (5X20) , Fuse 2A (10X38) , Fuse 1A (10X38) , Motor Circuit Breaker 2.5-4A , Motor Circuit Breaker 9-14A , Led 24V Ac/Dc , Contactor Lc1D18B7 18A 24Vac 50/6 , Contattore Lc1D09B7 9A 24Vac 50/6 , Contactor For Ecomar 4P 24V 50/60Hz , Relay 24Vac 40.52.8.024 , Flat Cable 20 Poles , Auxiliary Contactor Ladn20 , Measure And Control Relay 208-480Vac , Switching Power Input 24Vac Output 12/24Vdc

BOQ

Sl. No. Item TitleItem Description
1Overhaul of macerator pump iaw OEM manualOverhaul of macerator pump iaw OEM manual
2Renewal of macerator pumpRenewal of macerator pump
3Overhaul of macerator pump motor iaw OEM ManualOverhaul of macerator pump motor iaw OEM Manual
4Renewal of macerator pump motorRenewal of macerator pump motor
5Overhaul filling pump as per OEM manualOverhaul filling pump as per OEM manual
6Renewal of filling pumpRenewal of filling pump
7Overhaul of filling pump motor as per OEM manualOverhaul of filling pump motor as per OEM manual
8Renewal of filling pump motorRenewal of filling pump motor
9Overhaul of OBD pump as per OEM manualOverhaul of OBD pump as per OEM manual
10Renewal of OBD pumpRenewal of OBD pump
11Overhaul of OBD pump motor as per OEM manualOverhaul of OBD pump motor as per OEM manual
12Renewal of OBD pump motorRenewal of OBD pump motor
13Repair of OBD pump starterRepair of OBD pump starter
14Renewal of OBD pump starterRenewal of OBD pump starter
15Overhaul of IMO pump as per OEM manualOverhaul of IMO pump as per OEM manual
16Renewal of IMO pumpRenewal of IMO pump
17Overhaul of IMO pump motor as per OEM manualOverhaul of IMO pump motor as per OEM manual
18Renewal of IMO pump motorRenewal of IMO pump motor
19Repair of IMO pump starterRepair of IMO pump starter
20Renewal of IMO pump starterRenewal of IMO pump starter
21Overhaul/ repair of three way valve as per OEM manualOverhaul/ repair of three way valve as per OEM manual
22Renewal of three way valveRenewal of three way valve
23Overhaul/ repair of dosing pumpOverhaul/ repair of dosing pump
24Renewal of dosing pumpRenewal of dosing pump
25Renewal of dosing lineRenewal of dosing line
26Filling up of disinfectant fluid (H202 solution)Filling up of disinfectant fluid (H202 solution)
27Renewal of rubber compensator fitted between lines per plantRenewal of rubber compensator fitted between lines per plant
28Serviceability checks of solenoid valve for sea water supplyServiceability checks of solenoid valve for sea water supply
29Renewal of solenoid valve for sea water supplyRenewal of solenoid valve for sea water supply
30Serviceability checks for sensors for filling water pumpServiceability checks for sensors for filling water pump
31Renewal of sensor for filling water pumpRenewal of sensor for filling water pump
32Serviceability checks / repair of float switches fitted in collection tankServiceability checks / repair of float switches fitted in collection tank
33Renewal of float switches fitted in collection tankRenewal of float switches fitted in collection tank
34Serviceability checks/ repair of float switches fitted in treatment tankServiceability checks/ repair of float switches fitted in treatment tank
35Renewal of float switches fitted in treatment tankRenewal of float switches fitted in treatment tank
36Inspection, pressure testing/ leak testing per system pipelines including overload discharge lines, flushing lines, IMO lines, lower end vent line, tank vent line, tank vent lines, gas indicator lines and PVC line per meter.Inspection, pressure testing/ leak testing per system pipelines including overload discharge lines, flushing lines, IMO lines, lower end vent line, tank vent line, tank vent lines, gas indicator lines and PVC line per meter.
37Repair/ renewal of pipeline including overboard discharge lines, flushing lines, IMO lines, lower end vent line, tank vent lines, gas indicator lines and PVC line per meterRepair/ renewal of pipeline including overboard discharge lines, flushing lines, IMO lines, lower end vent line, tank vent lines, gas indicator lines and PVC line per meter
38Repair/ reconditioning of blower with motorRepair/ reconditioning of blower with motor
39Serviceability checks/ repair of pressure sensor fitted in collection tank for remote indication of level in DCHQServiceability checks/ repair of pressure sensor fitted in collection tank for remote indication of level in DCHQ
40Serviceability checks of electrical equipment / sensors fitted in tanks (viz over pressure sensor etc)Serviceability checks of electrical equipment / sensors fitted in tanks (viz over pressure sensor etc)
41Renewal of electrical equipment/ sensors fitted in tanks (viz over pressure sensor etc)Renewal of electrical equipment/ sensors fitted in tanks (viz over pressure sensor etc)
42Renewal of pressure sensor for remote indication of tank level in DCIQRenewal of pressure sensor for remote indication of tank level in DCIQ
43Overhauling / functionality checks of of electrical control panel (PLC based) and repair any defect on electrical control panelOverhauling / functionality checks of of electrical control panel (PLC based) and repair any defect on electrical control panel
44Renewal of electric component of electric control panelRenewal of electric component of electric control panel
45Repair/ renewal of electrical cable and accessories including earthingRepair/ renewal of electrical cable and accessories including earthing
46Inspection and calibration of instrumentation per plantInspection and calibration of instrumentation per plant
47Renewal of pressure gauges for OBS pumpsRenewal of pressure gauges for OBS pumps
48Endurance test and effluent test of samples of STP for BOD and TSS on completion of major repairs as proposed by SS/ every sixEndurance test and effluent test of samples of STP for BOD and TSS on completion of major repairs as proposed by SS/ every six
49Renewal of various tallies per plantRenewal of various tallies per plant
50Impeller for macerating / transfer pump S8 1Impeller for macerating / transfer pump S8 1
51Mechanical seal for macerating / transfer pump S8 1Mechanical seal for macerating / transfer pump S8 1
52Wear plate for S81Wear plate for S81
53Maintenance kit for dosing pumpMaintenance kit for dosing pump
542-WAY Valve 1' 24V Ac Gas F SOLEN2-WAY Valve 1' 24V Ac Gas F SOLEN
55Pressure RegulatorPressure Regulator
56Actuator for 3-WAY Valve 2\\"Actuator for 3-WAY Valve 2\\"
57Floating Level Sensor MobreyFloating Level Sensor Mobrey
58Level probe inox 316L, side mountingLevel probe inox 316L, side mounting
59Ecomar cover board PRO14 R3 for ecomarEcomar cover board PRO14 R3 for ecomar
60Actuator for rotary Valve EA0130Actuator for rotary Valve EA0130
61Flanged Rubber Joint DN25Flanged Rubber Joint DN25
62Flanged Rubber Joint DN50Flanged Rubber Joint DN50
63Flanged Rubber Joint DN65Flanged Rubber Joint DN65
64Flanged Rubber Joint DN80Flanged Rubber Joint DN80
65PCB Board PRO14/02PCB Board PRO14/02
66EXP14/0A REV. 1 Board For ECOMAREXP14/0A REV. 1 Board For ECOMAR
67Transformer 100VA Prim: 230/400/415-SEC: 12/24VTransformer 100VA Prim: 230/400/415-SEC: 12/24V
68Transf. 400VA Prim: 380-400-415-440V SEC.230VTransf. 400VA Prim: 380-400-415-440V SEC.230V
69Fuse 2A (5X20)Fuse 2A (5X20)
70Fuse 2A (10x38)Fuse 2A (10x38)
71Fuse 1A (10x38)Fuse 1A (10x38)
72Motor Circuit Breaker 2.5-4AMotor Circuit Breaker 2.5-4A
73Motor Circuit Breaker 9-14AMotor Circuit Breaker 9-14A
74LED 24V AC/DCLED 24V AC/DC
75Contactor LC1D18B7 18A 24VAC 50/6Contactor LC1D18B7 18A 24VAC 50/6
76Contattore LC1D09B7 9A 24VAC 50/6Contattore LC1D09B7 9A 24VAC 50/6
77Contactor for ECOMAR 4P 24V 50/60HzContactor for ECOMAR 4P 24V 50/60Hz
78Relay 24VAC 40.52.8.024Relay 24VAC 40.52.8.024
79Flat Cable 20 PolesFlat Cable 20 Poles
80Auxiliary Contactor LADN20Auxiliary Contactor LADN20
81Measure and Control Relay 208-480VACMeasure and Control Relay 208-480VAC
82Switching Power Input 24VAC output 12/24VDCSwitching Power Input 24VAC output 12/24VDC

AI Tender Summary

OUR REF NO 57279437
AUTHORITY Government Departments
TENDER VALUE 5.81 Crore
LAST DATE 21-09-2026
Authority
Authority Name Indian Navy
Work Description Bids Are Invited For Custom Bid For Services - Repair Rate Contract For Routine/ Repair Of Stp System Onboard In Ships For A Period Of One Year And Extendable For Two More Years At Nd (Kar) - Overhaul Of Macerator Pump Iaw Oem Manual , Renewal Of Macerator Pump , Overhaul Of Macerator Pump Motor Iaw Oem Manual , Renewal Of Macerator Pump Motor , Overhaul Filling Pump As Per Oem Manual , Renewal Of Filling Pump , Overhaul Of Filling Pump Motor As Per Oem Manual , Renewal Of Filling Pump Motor , Overhaul Of Obd Pump As Per Oem Manual , Renewal Of Obd Pump , Overhaul Of Obd Pump Motor As Per Oem Manual , Renewal Of Obd Pump Motor , Repair Of Obd Pump Starter , Renewal Of Obd Pump Starter , Overhaul Of Imo Pump As Per Oem Manual , Renewal Of Imo Pump , Overhaul Of Imo Pump Motor As Per Oem Manual , Renewal Of Imo Pump Motor , Repair Of Imo Pump Starter , Renewal Of Imo Pump Starter , Overhaul/ Repair Of Three Way Valve As Per Oem Manual , Renewal Of Three Way Valve , Overhaul/ Repair Of Dosing Pump , Renewal Of Dosing Pump , Renewal Of Dosing Line , Filling Up Of Disinfectant Fluid (H202 Solution) , Renewal Of Rubber Compensator Fitted Between Lines Per Plant , Serviceability Checks Of Solenoid Valve For Sea Water Supply , Renewal Of Solenoid Valve For Sea Water Supply , Serviceability Checks For Sensors For Filling Water Pump , Renewal Of Sensor For Filling Water Pump , Serviceability Checks / Repair Of Float Switches Fitted In Collection Tank , Renewal Of Float Switches Fitted In Collection Tank , Serviceability Checks/ Repair Of Float Switches Fitted In Treatment Tank , Renewal Of Float Switches Fitted In Treatment Tank , Inspection, Pressure Testing/ Leak Testing Per System Pipelines Including Overload Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter. , Repair/ Renewal Of Pipeline Including Overboard Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter , Repair/ Reconditioning Of Blower With Motor , Serviceability Checks/ Repair Of Pressure Sensor Fitted In Collection Tank For Remote Indication Of Level In Dchq , Serviceability Checks Of Electrical Equipment / Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Electrical Equipment/ Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Pressure Sensor For Remote Indication Of Tank Level In Dciq , Overhauling / Functionality Checks Of Of Electrical Control Panel (Plc Based) And Repair Any Defect On Electrical Control Panel , Renewal Of Electric Component Of Electric Control Panel , Repair/ Renewal Of Electrical Cable And Accessories Including Earthing , Inspection And Calibration Of Instrumentation Per Plant , Renewal Of Pressure Gauges For Obs Pumps , Endurance Test And Effluent Test Of S Les Of Stp For Bod And Tss On Completion Of Major Repairs As Proposed By Ss/ Every Six , Renewal Of Various Tallies Per Plant , Impeller For Macerating / Transfer Pump S8 1 , Mechanical Seal For Macerating / Transfer Pump S8 1 , Wear Plate For S81 , Maintenance Kit For Dosing Pump , 2-Way Valve 1 24V Ac Gas F Solen , Pressure Regulator , Actuator For 3-Way Valve 2 , Floating Level Sensor Mobrey , Level Probe Inox 316L, Side Mounting , Ecomar Cover Board Pro14 R3 For Ecomar , Actuator For Rotary Valve Ea0130 , Flanged Rubber Joint Dn25 , Flanged Rubber Joint Dn50 , Flanged Rubber Joint Dn65 , Flanged Rubber Joint Dn80 , Pcb Board Pro14/02 , Exp14/0A Rev. 1 Board For Ecomar , Transformer 100Va Prim: 230/400/415-Sec: 12/24V , Transf. 400Va Prim: 380-400-415-440V Sec.230V , Fuse 2A (5X20) , Fuse 2A (10X38) , Fuse 1A (10X38) , Motor Circuit Breaker 2.5-4A , Motor Circuit Breaker 9-14A , Led 24V Ac/Dc , Contactor Lc1D18B7 18A 24Vac 50/6 , Contattore Lc1D09B7 9A 24Vac 50/6 , Contactor For Ecomar 4P 24V 50/60Hz , Relay 24Vac 40.52.8.024 , Flat Cable 20 Poles , Auxiliary Contactor Ladn20 , Measure And Control Relay 208-480Vac , Switching Power Input 24Vac Output 12/24Vdc
Basic Detail
Tender No GEM/2026/B/7914384
Bidding Type Tender
Location
City uttara kannada
State Karnataka
Key Dates
Publish Date 31 Aug 2026
Submission Date 21 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 5.81 Crore
Tender Fee Ref. Documents
EMD 17.43 Lakhs
Exemption Not Available
Document List
978754e8-45eb-4a3b-9bcc-72623572c833.pdf
1786615278.xlsx
1786618006.pdf
1786618029.pdf
1786618044.pdf
1786618128.pdf
1786618140.pdf
1786618147.pdf
1786618161.pdf
1786618175.pdf
1786618294.pdf
1786618328.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

978754e8-45eb-4a3b-9bcc-72623572c833.pdf

xlsx

1786615278.xlsx

pdf

1786618006.pdf

pdf

1786618029.pdf

pdf

1786618044.pdf

pdf

1786618128.pdf

pdf

1786618140.pdf

pdf

1786618147.pdf

pdf

1786618161.pdf

pdf

1786618175.pdf

pdf

1786618294.pdf

pdf

1786618328.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders