Tender For Repair / Replacement And Maintenance Of 66/11 Kv Sub Station Alongwith Other Connected Works Under Age E/M-Ii Of Ge 865 Ews
Tender Overview
Project Description
Tender For Repair / Replacement And Maintenance Of 66/11 Kv Sub Station Alongwith Other Connected Works Under Age E/M-Ii Of Ge 865 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Sep-2026 | REVISION OF CRITICAL DATES | Date | 05-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting of HT supply from 11 KV VCB of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution and inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc. including checking of vaccume intrupter, tripping mechanism and ratchet wheel & spring charging mechanism etc. after servicing, complete all as specified and / or as directed by Engr-in-Charge. |
| 2 | Disconnecting of HT supply from 66 KV VCB/SF-6 breaker of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc. including checking of its control panel and power TR protection system such as defferential realy, master trip relay, power TR oil/windinding temp, bucolz relay and mechanical system etc. after servicing testing complete all as specified and / or as directed by Engr-in-Charge.Note for srl item 1.00 to 2.00 :- (i) Spare parts will be measured and paid for separatily under respective item and if copper wire and ferule required for wiring include in this items.(ii) For testing and calibration of relays will be measured and paid separately under respective items.(iii) Any damage, loss, accident or danger arising due to malfunction, negligence or improper execution of work shall be the sole responsibility and liability of the contractor. |
| 3 | Taking out IDMT relays from panel. Opening it for repair work, servicing complete with decarburizing the contact points, cleaning with CRC solution and inner body clean with vaccum cleaner etc and repair/replacement of all defective parts if any found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc. complete all as specified and / or as directed by Engr-in-Charge. NOTE :- All parts are deemed to be include in this item rate required for relay in service condition. |
| 4 | Supply only of following parts of HT VCB for item No 1.00 & 2.00 above :- |
| 5 | Spring charging motor 24-30/240 Volt DC/AC for 66 KV VCB/SF-6 breaker of existing make, type, size & capacity complete. Make : As per existing sample. |
| 6 | Spring charging motor 30/240 Volt DC/AC for 11KV VCB of existing make, type, size & capacity complete suitable for existing VCBs complete Make : As per existing sample. |
| 7 | Open/Close auxiliary contacts switch suitable for upto 1600 Amp HT VCB. Make/Type- As per existing sample. |
| 8 | Open/Close auxiliary contacts switch suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 9 | Plug-Socket connectors of electrical accessories suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 10 | Door locking handle suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 11 | Trolly alignment lever suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 12 | Under voltage release suitable for 1600 Amps HT VCB. Make/Type- As per existing sample. |
| 13 | Under voltage release suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 14 | Over voltage release suitable for 1600 Amps HT VCB. Make/Type- As per existing sample. |
| 15 | Over voltage release suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 16 | Under/over frequency release suitable for 1600 Amps HT VCB. Make/Type- As per existing sample. |
| 17 | Under/over frequency release suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample. |
| 18 | Shunt trip closing coil assembly 66 KV SF6 Breaker 24-30/220 volts, DC/AC. Make/Type- As per existing sample. |
| 19 | Shunt trip tripping coil assembly 66 KV SF6 Breaker 24-30/220 volts, DC/AC. Make/Type- As per existing sample. |
| 20 | Shunt trip closing coil assembly 24-30/220 volts, DC/Ac for HT VCB. Make/Type- As per existing sample. |
| 21 | Shunt trip tripping coil assembly 24-30/220 volts, DC/AC for HT VCB. Make/Type- As per existing sample. |
| 22 | Series trip coil 24-30/220 volts, DC/AC for HT VCB. Make/Type- As per existing sample. |
| 23 | Spring charging Motor Cut of switch. Make/Type- As per existing sample. |
| 24 | Ratchet wheel Assembly (small, large & middle gear assy). Make/Type- As per existing sample. |
| 25 | Manual spring charging gear assembly complete. Make/Type- As per existing sample. |
| 26 | Breaker IN/OUT handle. Make/Type- As per existing sample. |
| 27 | Local remote switch. Make/Type- As per existing sample. |
| 28 | Test/service position indicator. Make/Type- As per existing sample. |
| 29 | Breaker control switch. Make/Type- As per existing sample. |
| 30 | Mechanism charged/discharge indicator switch. Make/Type- As per existing sample. |
| 31 | Toggle ON/OFF switch for Heater & illumination circuit. Make/Type- As per existing sample. |
| 32 | Mechanical ON/OFF indication. |
| 33 | Door switch. Make/Type- As per existing sample. |
| 34 | Auto/Manual selection switch. Make/Type- As per existing sample. |
| 35 | Push button. Make/Type- As per existing sample. |
| 36 | ON/OFF Emergency trip push button. Make/Type- As per existing sample. |
| 37 | Indicator lamp LED type complete with holder to read RYB with necessary wiring complete. |
| 38 | Operation counter. Make/Type- As per existing sample. |
| 39 | Selector switch for voltmeter- 4 position (RY-YB-BR-OFF), 3 ways . |
| 40 | TNC control switch with pistol grip. |
| 41 | Spring charging handle. |
| 42 | VCB operating handle. |
| 43 | Terminal connectors. |
| 44 | Annunciator, 4 Window with existing dimension on panel for OC/EF/WTI/OTI/ Bucholz trip, with inbuilt PB of mute, ACK, Reset, Accept. |
| 45 | Master relay operating voltage 24V/110V DC or as per sample complete all as directed. |
| 46 | Spacer Heater. Make/Type- As per existing sample. |
| 47 | Thermostate 30-90 Deg. |
| 48 | Hooters. Make/Type- As per existing sample. |
| 49 | Terminal Block for CT wire. |
| 50 | Terminal Block for Remote feedback/within panel/board wire |
| 51 | NO/NC Contacts Make/Type- As per existing sample. |
| 52 | Bridge rectifier Make/Type- As per existing sample. |
| 53 | Auxiliary switch 7NO + 7NC Make/Type- As per existing sample. |
| 54 | \\"ZZ\\" micro switch Make/Type- As per existing sample. |
| 55 | Butterfly switch for motor cut off Make/Type- As per existing sample. |
| 56 | Motor cut off switch (Cherry) Make/Type- As per existing sample. |
| 57 | Timer for spring charging motor Make/Type- As per existing sample. |
| 58 | Drive link assembly with adjuster Make/Type- As per existing sample. |
| 59 | Big cam with main shaft with bearing & cover Make/Type- As per existing sample. |
| 60 | Trip /Close shaft assembly with springs & closing strips Make/Type- As per existing sample. |
| 61 | 11KV, VCB Fixed contact suitable for 1600Amp capacity. Make/Type- As per existing sample. |
| 62 | 11KV, VCB moving contact suitable for up to 1600Amp capacity. Make/Type- As per existing sample. |
| 63 | 11KV, VCB Fixed contact suitable for 1250Amp capacity. Make/Type- As per existing sample. |
| 64 | 11KV, VCB moving contact suitable for 1250Amp capacity. Make/Type- As per existing sample. |
| 65 | Spout insulator incl hardware suitable for 11KV VCB of various capacity Make/Type- As per existing sample. |
| 66 | Spur gear of sizes as per sample suitable for upward or downward trolly movement mechanism with lock and bushing as required for 11KV VCB/bus coupler complete. Make/Type- As per existing sample.complete all as specified and / or as directed by Engr-in-Charge. |
| 67 | Trip shackle lever. Make/Type- As per existing sample. |
| 68 | Ratchet Pin suitable for HT VCB (As per sample) complete all as directed. |
| 69 | Insulated dust proof cover frame. Make/Type- As per existing sample. |
| 70 | Push Rod. Make/Type- As per existing sample. |
| 71 | Fuses holder suitable for cylindrical/DIN fuse. |
| 72 | HRC fuse (link type) having capacity 2 to 6 amp, 415 V, 80 KA. |
| 73 | HRC fuse (link type) having capacity 10 to 32 amp, 415 V, 80 KA. |
| 74 | 11 KV, VCB, PT fuse 3.15 Amp complete as per sample. |
| 75 | Stud type terminals of 30V/110V DC suitable for 11KV VCB. |
| 76 | Antipumping Contactor 4NO+4NC, 24V/110V DC, 6 Amp Make/Type- As per existing sample. |
| 77 | Auxilary contactor for contact multiplication 4NO+4NC, 24V/110V, DC, 6 Amp Make/Type- As per existing sample. |
| 78 | Testing and calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system for smooth functioning and tripping at any type of fault developed in feeders complete all as specified and/or as directed by Engr-in-Charge. Note :- Contractor will submit primary and secondary test record at the time of caliberation of HT VCB, SF-6 based panel, TR control panel by current injecting kit duly signed to Engineer In Charge. The rate quoted by tender shall deemed to include the cost of this provision incl T&P required for injecting regulated high current, HT megger and other sundry items as required in complaince with relevent IS/IEC codes. |
| 79 | S & F in replacement Vaccum interrupter bottle for vaccum circuit breaker of 1600 Amps in HT panel 11000 volts grade complete all as directed. Make/Type- As per existing sample. |
| 80 | All as per Srl item No 6.00 above but up to 1250 Amps capacity. |
| 81 | S&F in replacement indicators flush mounted, high intensity, clustered LED type, insulated from 30/220 V, DC/AC supply with appropriate coloured code (Red, Green, Blue, Amber, White) complete all as specified and directed by Engr-in-Charge. |
| 82 | S & F in replacement MCB single pole 6 to 32 amps of 10 KA in existing panel with incoming and outgoing connection complete all as directed by Engr-in-Charge. Make : Legrand/L&T/Siemens as approved by GE |
| 83 | S&F in replacement Bus Support insulators, non hygroscopic, track-resistant, high strength epoxy insulators complete all as specified and / or as directed by Engr-in-Charge. |
| 84 | S & F in replacement of lugs, tinned copper, pre-insulated fork and pin type as applicable complete all as specified and / or as directed by Engr-in-Charge. |
| 85 | Supply, installation, testing and commissioning in replacement of 11KV Current Transformer with Indoor & Resin cast type single pole (Three core type) CTR-600-300/5+5A, STR - 26.3KA/3Sec, insulation level 28KV/75KVP, duty cycle: 0.03 Sec,-CO-3 Min,-CO fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel complete. Make / Type- as per existing sample. complete all as specified and / or as directed by Engr-in-Charge. |
| 86 | S & F in replacement of unsv defective PT unit 3 PH, Drawout type, VTR - 11000/110V AC, BA- 100VA/CL0.5 of breaker in VCB make / type as per existing of voltage transformer from VCB including, nut bolts, washers, re-assembling the complete parts, complete testing for smooth operation, all as directed. Make - As per existing sample of Voltage Transformer Type - 3PH, Drawout type, VTR - 11000/110V AC, BA- 100VA/CL0.5 |
| 87 | S & F in replacement of UNSV defective protective relays with Digital protective Relay - 3 OC + 1 Earth fault 3 phase over current and earth fault (2 NO + 2 NC output contact) with high set, CT rating 5A, field selectable 20-110V, including addition/alteration including testing,calibration of relays and replaced control wring as required at site. Make/ Type. all as per existing sample. |
| 88 | M&L for wiring from battery charger to all 11 KV VCB with 2.5 sqmm, 1100 volt grade multi strand flexible copper conducters and shall be properly bunched, tied, ferruled for proper indication and crimped with adequate size/types of lugs after wiring testing complete. complete all as specified and / or as directed by Engr-in-Charge. |
| 89 | Supply and errect fire stand of suitable size made out of MS / angle iron/ channel duly painted with two coats of synthetic enamel paint post office red colour over a coat of red oxide as primer and lettering with white paint including providing the following. complete all as specified and / or as directed by Engr-in-Charge :- (a) Galvanised MS fire buckets 9 litre capacity - 04 No's) Portable fire extinguisher CO2 type 4 Kg capacity - 04 No's Make:- Ceasefire / Firex/Omex (ABC) |
| 90 | S&F PVC insulated and PVC sheathed cable galvanised steel stip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 12 core 1100 volt grade incl taking out old cable of any size and type complete. complete all as specified and / or as directed by Engr-in-Charge. |
| 91 | All as per item No 18.00 here in before but 2.5 Sqmm 6 core 1100 volts grade. |
| 92 | All as per item No 18.00 here in before but 2.5 Sqmm 4 core 1100 volts grade. |
| 93 | All as per item No 18.00 here in before but 2.5 Sqmm 2 core 1100 volts grade. |
| 94 | Supply & Laying in trenches/through pipes / ducts or on poles XLPE insulated,screened, PVC bedded, galvanised steel strip armoured ,electric power cables(heavy duty) with aluminium conductor, 11 KV,earthed grade 120 sqmm 3 core (E) confirming to IS-7098. incl taking down old one. complete all as specified and / or as directed by Engr-in-Charge. |
| 95 | Supply & Laying in trenches/through pipes / ducts or on poles XLPE insulated,screened, PVC bedded, galvanised steel strip armoured , electric power cables(heavy duty) with aluminium conductor, 11 KV,earthed grade 185 sqmm 3 core (E) confirming to IS-7098. incl taking down old one. complete all as specified and / or as directed by Engr-in-Charge. |
| 96 | Supply & Laying in trenches/through pipes / ducts or on poles XLPE insulated,screened, PVC bedded, galvanised steel strip armoured , electric power cables(heavy duty) with aluminium conductor, 11 KV,earthed grade 400 sqmm 3 core (E) confirming to IS-7098. incl taking down old one. complete all as specified and / or as directed by Engr-in-Charge. |
| 97 | Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 3 core with working voltage 11000 volts. complete all as specified and / or as directed by Engr-in-Charge. |
| 98 | Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm 3 core with working voltage 11000 volts. complete all as specified and / or as directed by Engr-in-Charge. |
| 99 | Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 sqmm 3 core with working voltage 11000 volts. complete all as specified and / or as directed by Engr-in-Charge. |
| 100 | Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm . complete all as specified and / or as directed by Engr-in-Charge. |
| 101 | Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm . complete all as specified and / or as directed by Engr-in-Charge. |
| 102 | Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 Sqmm . complete all as specified and / or as directed by Engr-in-Charge. |
| 103 | Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm. complete all as specified and / or as directed by Engr-in-Charge. |
| 104 | Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm. complete all as specified and / or as directed by Engr-in-Charge. |
| 105 | Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 Sqmm. complete all as specified and / or as directed by Engr-in-Charge. |
| 106 | S & F in replacement lighting arrester expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 66000 V and required zccessories type as per existing including taking down old unserviceable lighting arrester. complete all as specified and / or as directed by Engr-in-Charge. |
| 107 | Supply and fixing in replacement 11 KV VCB switchgear 350MVA, 600/300/5-5-1A with vacuum circuit breker & control panel including cast resin CT, PT, E/F & C/O relay, Minic diagram, voltmeter, static energy meter with communication port, Annucciation window and annunciation relay and other accessories etc. for incoming feeder complete type as per existing including taking down old UNSV VCB. complete all as specified and direced by Engr- in Charge. |
| 108 | Supply and fixing in replacement 11 KV VCB switchgear 350MVA,500/300/5-5-1A with vacuum circuit breker & control panel including cast resin CT, PT, E/F & C/O relay, Minic diagram, voltmeter, static energy meter with communication port, Annucciation window and annunciation relay and other accessories etc. for outgoing feeder complete type as per existing including taking down old UNSV VCB. complete all as specified and direced by Engr- in Charge. |
| 109 | Supply and fixing in replacement Trolly of vaccum circuit breaker 800/1200 Amps 11KV in close cabinet suitable for 11 KV Make Electrofield,with moving and fixing contact,control wiring of micro processor EF/OC relay, triping coil, manual/auto triping system complete, including all machnical settings and placing the breaker trolly in it enclosure as existing in 66/11 Sub station complete and testing on full load. complete all as specified and / or as directed by Engr-in-Charge.Note:-(i) The trolly comprising with the following part :- (a) Fixed contact block complete suitable for 800/1200 amp, 11KV HT VCB in existing make and size. (b) Moving contact block complete suitable for 800/1200 amp, 11KV HT VCB in existing make and size.(c) Mechanical castle interlock assy with key suitable for HT 11 KV VCB of rating 800/1200 AMP.(d) Closing coil assy 230V AC/ 24 V DC(e) Triping coil with plunger assy 230 V AC / 24 V DC, Cat part No as per existing.(f) Closing coil plunger with 24 V DC, Cat part No as per existing.(g) Support Bushing 11 KV for VCB.(h) Vacum Interruptor type as per existing suitable for HT VCB 800/1200 Amp. |
| 110 | Supply and fixing in replacement 30V 200 AH Battery bank consisting of 2V 200 AH Batteries 15 Nos with terminal connections and mounting race including accessories. complete all as specified and / or as directed by Engr-in-Charge. |
| 111 | Supply and fixing in replacement 30-V, 20A Flot cum booster charger Auto / manual selection with full waverectification for 220V, 1 phase, 50Hz AC input along with inbuilt DC distribution box. complete all as specified and / or as directed by Engr-in-Charge. |
| 112 | Supply and filling SF6 Gas with 11 Kg cylinder. complete all as specified and / or as directed by Engr-in-Charge. |
| 113 | Supply , fixing and testing and commissioning in replacement of 66/11KV Current Transformer (CT) Suitable for existing VCB panel Rating 600-300/5-5-1A. complete all as specified and / or as directed by Engr-in-Charge. |
| 114 | Supply and fill up transformer oil as in topping up/ refilling of transformer having dielectric strength not less than 55 KV at 2.5 mm gap conforming to IS incl testing complete. complete all as specified and / or as directed by Engr-in-Charge. Make : Savita/Power Oil/Trans Oil. |
| 115 | Supply and fixing petroleum jelly used for 66 KV sub stn. complete all as specified and / or as directed by Engr-in-Charge. |
| 116 | Supply and filling Silica Gel 6-10mm all as specified and directed. |
| 117 | Supply only rubber hand gloves (ISI Marked) suitable for working with 66 KV HT lines. complete all as specified and directed. |
| 118 | Material and labour for danger notice plate for HT of size 25 cm x 20 cm x 1.6 mm thick mild steel sheet, synthetic enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts. complete all as specified and / or as directed by Engr-in-Charge. |
| 119 | Supply and fix and replacement of HT thimble for 400 Sqmm all as specified and directed. |
| 120 | Supply and fix and replacement of HT thimble for 185 Sqmm all as specified and directed. |
| 121 | Supply and fix and replacement of HT thimble for 120 Sqmm all as specified and directed. |
| 122 | Supply and laying in replacement synthetic insulated mats 4.0mm thick for voltage upto 66KV for electrical perpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of size 2 Mtr x 1Mtr all as specified and directed. |
| 123 | Supply and fixing in replacement HT 66 KV Line Insulator link set - 800 A 25 KA, 3 Phase all as specified and directed. |
| 124 | Supply and fixing in replacement of ACSR panther conductor for 66 KV over head tower line, all as specified and directed. |
| 125 | Supply and fixing in replacement P. G clamp for panther conductor for 66 KV over head tower line all as specified and directed. |
| 126 | Supply and fixing in replacement T clamp for panther condectore for 66 KV over head tower line all as specified and directed. |
| 127 | Checking for power transformer 6.3 MVA of hand operation of all taps including handle interlock switch, local and remote operation of accessories, WTI/OTI indication. Inspection and testing of transformer including drying / replacement of silica jel, checking of buchhloz relay, conservator oil level indicator, temp, sensore, topping of oil cooling system, alarm/ trip circuit. Measurement of IR relay,dielectric strength of transformer oil and BDV and Gas analysis of oil and submmiting test report from auth Lab or department , checking of marshalling box of OLTC, NGR, T.B of PDR, Bucholz relay, external cleaning of radiators, bushings etc. Note :- (i) Testing shoud be carried out from IEM/Auth testing ajency and all T & P shall be arranged by contractor. |
| 128 | Testing of capacitance and Tan Delta test , Narrow Band Dielectric frequency response winding test, Capacitance and Tan Delta & Narrow Band Dielectric frequency response Bushing (1--505 Hz) and Polarization Index (PI) of Transformer 6.3 MVA capacity from any authorised Lab/OEM or state electricity deptt and submmiting test report accordingly complete all as specified and directed. Note :- (i) All T&P & testing machine shall be arranged by contractor. |
| 129 | Testing of Transformer Turns Ratio test, Exitaion current test, Magnetic balance test, HV/LV winding resistance test, of Transformer 6.3 MVA capacity from any authorised Lab/OEM or state electricity deptt and submmiting test report accordingly complete all as specified and directed. Note :- (i) All T&P & testing machine shall be arranged by contractor. |
| 130 | Supply and fixing in replacement of HV (66KV side) bushing with brass metal connecting rod, nut, bolt and washer suitable for transformer 6.3MVA, 66/11KV as per IS, replacement of worn out stud complete all as specified and directed. |
| 131 | Supply and fixing in replacement of HV (11 KV Side) Bushing of transformer with Brass metal connecting rod, nut bolt and washer, suitable for 6.3MVA, 66/11KV capacity of transformer as per IS complete all as specified and directed. |
| 132 | Supply and fixing in replacement of HV bushing with brass metal connecting rod, nut, bolt and washer suitable for transformer 100 KVA, as per IS 1961, complete all as specified and directed. |
| 133 | Supply and fixing in replacement of LV Bushing of transformer with Brass metal connecting rod, nut bolt and washer, suitable for 100 KVA capacity of tranaformer 1100 Volt as per IS complete all as specified and directed. |
| 134 | Servicing of 66 KV isolator switch after taking proper safety measures and shut down , decabonizing of all contacts with anti corrosive solution and applying petrolium jelly to all contacts and greasing to all moving mechanical parts, tightening of all connection clamps and proper adjustment of isolator complete all as specified and directed. |
| 135 | Supply and fixing in replacement of male contact made out of tinned copper suitable for 66 KV isolator horizontal type as per existing complete with all nut bolt washers and fixing accessories complete all as specified and ditected. |
| 136 | Supply and fixing in replacement of female contact made out of tinned copper suitable for 66 KV isolator horizontal type as per existing complete with all nut bolt washers and fixing accessories including applying petrolium jelly complete all as specified and directed. |
| 137 | Dehydration of HV / EHV grade transformer oil minimum three cycles to achieve dielectric strength not less than 50 KV for 1 minute with 2.5mm Gap as per IS - 335 - 1983 for EHV grade including topping up with new transformer oil all as per specified and directed. Note :- (i) Centrifuging Machine with all T&P & testing machine of oil, required for dehydration shall be arranged by contractor at site. (ii) Oil required for topping up the transformer will be measured & paid separately. |
| 138 | M&L for GI nuts, bolts, off sizes complete with 3mm thick washers as per site requirement fixed in repairs. |
| 139 | Labour only for checking the serviceability of ACB/OCB/ACB/CT/PT panels or any connected electrical switch gear at 11 KV voltage level of any capacity including disconnecting HT/LT supply from any VCB & ACB if needed and testing of different spares / components / parts of panels of any description and in any position, checking functioning of relay, coils, switches, ratchet wheel assy, chrging motor, fuses contactors, MCCBs etc and their replacement if found to be unserviceable, regular cleaning of dust & dirt deposit due to natural effects, removal of carbon deposits it any or as direction of Engr-in-Charge. Replacement of un-serviceable/ damaged /broken part(s) either in single or in combination, re-assembling the panels and making the serviceable, fixing the VCB/ACB in position, connecting to electric supply and its testing on installation. complete all as specified and directed by Engineer-in-Charge.NOTE FOR ALL ITEMS OF THIS BOQ : The contractor shall depute his representative to Engineer -in-charge or his representative (JE incharge of the contract) on daily basis to collect the complaints. There after contractor shall deploy sufficient manpower to attend the complaints on daily basis. The contractor shall arrange his resources accordingly. Non -compliance of the above on account of contractor's representative to Engineer incharge/JE or deployment of in-sufficient manpower to attend the complaints shall be bound to a penalty of Rs 1500/- per complaint per day after 02 Hrs of communication of complaint by any mode of communication (via SMS, telephone call, whatsapp etc to contractor/contractors rep). Contractor must also mobilise/procure/arrange all tools & machinery like megger, earthing rod, protective gear, test lamp etc for expeditions & safe working compulsary. It is mandatory for all prospective bidders to undertake a site visit before submitting their bids. The purpose of the site visit is to provide the bidders with a comprehensive understanding of the site requirements and the conditions that may affect the execution the work. It is mandatorty for bidders to take reciept of each site visit from Engineer-in -Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender