Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Bsnl Ed Bg Nit No 18 Providing Repairs To Ei And Fans In E19 Quarters At Wms Compound Jayanagar Bengaluru; Electrical System Or Installation; Servic
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Bsnl Ed Bg Nit No 18 Providing Repairs To Ei And Fans In E19 Quarters At Wms Compound Jayanagar Bengaluru; Electrical System Or Installation; Service Provider - Supplying And Replacing Following Piano Type Switch/ Socket/ Electronic Fan Regulators/Call Bell On The Existing Switch Box/Junction Box Including Removing The Existing Faulty Switches, Connections Etc. As Required. (Make: M/S Anchor Or Ss Make) (A) 5/6 S Switch , B) 5/6A 2Way Switch , C) 3 Pin 5/6 A Socket Outlet , D) 15/16 A Switch , E) 6 Pin 15/16 A Socket Outlet , F)100 Watt Step Type Electronic Mini Fan Regulator , G) Pvc Angle/Batten Holder , H) Call Bell , I) 3 Pin Ceiling Rose , J) 16A 3 Pin Plug Top , Supplying And Replacing Following Modular Type Switch/ Socket/ Electronic Fan Regulators/Call Bell On The Existing Switch Board/Junction Box Including Connections Etc. As Required. (Make: M/S Anchor Roma Or Ss Make) (A) 10 S Switch , B) 2 Way 10 A Switch , C) 3 Pin 6 A Socket Outlet , D) 32 A Dp Switch , E) 6 Pin 6/16 A Socket Outlet , F) 10 Bell Push , Supplying & Fixing Following Module Surface/Recess Modular Pvc/Gi Enclosure Etc Complete As Reqd. (Make Anchor Roma Or Similar Superior Make) (A) 3 Module , B) 4 Module , C) 8 Module , Supplying & Fixing Following Module Cover Plate On Existing Surface/Recess Modular Pvc/Gi Enclosure Etc Complete As Reqd. (Make Anchor Roma Or Similar Superior Make) (A) 3 Module , B) 4 Module , C) 8 Module , Fixing Of 24W 4Ft Led Batten On Surface Of Wall/Ceiling , Connection From Existing Point Etc Complete As Required , Supplying And Fixing Of Foot L Suitable For 230 Volts 50Hz Ac Supply Along With S/F 3Mm Thick (Nominal) Phenolic Laminated Sheet On The Existing Ms Enclosure Etc Complete As Reqd (M/S Anchor Woods Foot Light Led White 3M Or Similar Superior Make) , Supplying And Fixing 10W Led Type Polycarbonate Bulkhead Fitting Including Connections Etc Complete As Reqd (M/S Crompton/Philips/Havells Or Ss Make) , Supplying And Fixing Of 18W Led Type Round Surface Fitting Made Of Polycarbonate Suitable For 230 Volts 50Hz Ac Supply Etc Complete As Reqd (M/S Crompton Or Ss Make) , Supplying And Fixing Of 5W, 1 Led Mirror Light Suitable For 230 Volts 50Hz Ac Supply Etc As Reqd (M/S Crompton Or Ss Make) , Supplying And Fixing 9W Wall Mounting Led Decorative Fitting Suitable For Operation On 230V, 1Ph, 50Hz Ac Supply Including Connections Etc As Required , Replacing The Led L In Existing Street Light Fitting With 22W Led Bulb Including Dismantling The Dome, Fixing New Bulb, Cleaning The Dome, Fixing, Arranging Suitable Ladder Etc As Required (M/S Crompton Or Similar Superior Make) , Replacement And Installation Of 1200Mm Sweep Ceiling Fan Suitable For Working On 230V 50Hz Ac Supply, 1Star Rated, Including Removing Of Faulty Fan Etc As Reqd.(M/S Crompton Greaves Or Superior Make) , Replacement And Installation Of 250Mm Sweep Ventilation Fan In Washroom Suitable For 1Phase, 230Volts, 50Hz Ac Supply, & Testing Commissioning Etc As Required. (Make: Crompton/Havells Or Ss Make) , Replacement And Installation Of 150Mm Sweep Ventilation Fan In Washroom Suitable For 1Phase, 230Volts, 50Hz Ac Supply, & Testing Commissioning Etc As Required. (Make: Crompton/Havells Or Ss Make) , Replacement And Installation Of 300Mm Sweep Exhaust Fan Fan Suitable For Working On 230V 50Hz Ac Supply Including Removing The Faulty Fan, Connections From Existing Point, Testing Etc As Reqd (M/S Crompton Greaves Or Superior Make) , Replacing The Damaged Louvers Suitable For 300Mm Exhaust Fan Including Removing The Faulty Louver, Fixing Etc As Required , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit/Pvc Casing & Capping As Required. A) 3 X 1.5 Sq. Mm , B) 3 X 2.5 Sq. Mm , Supplying And Fixing Of Following Sizes Of Pvc Casing And Capping With All Accessories Etc As Reqd. (Avonplast Or Ss Make) A) 20 X 10Mm , Replacing Of Storage Type 25 Litres Capacity 5 Star Rated Vertical Geyser With Inbuilt Thermostat, Cord Wire And 3Pin Plug Suitable For Working On 230V 50Hz Supply Including Inlet And Outlet Flexible Braided Water Pipe, Testing And Connections Etc As Reqd.(M/S Racold Cdr Or Similar Superior Make) , Replacing The Existing Switch Plate With 3Mm Thick (Nominal) Phenolic Laminated Sheet Of Size About 0.28X0.20M On The Existing Enclosure For Closing Unused Openings Including Providing Necessary Hardware Etc As Required , Replacing The Existing Switch Plate With 3Mm Thick (Nominal) Phenolic Laminated Sheet Of Size About 0.28X0.13M On The Existing Enclosure For Closing Unused Openings Including Providing Necessary Hardware Etc As Required , Replacing The Existing Switch Plate With 3Mm Thick (Nominal) Phenolic Laminated Sheet Of Size About 0.13X0.13M On The Existing Enclosure For Closing Unused Openings Including Providing Necessary Hardware Etc As Required , Replacing The Existing Switch Plate With 3Mm Thick (Nominal) Phenolic Laminated Sheet Of Size About 0.18X0.13M On The Existing Enclosure For Closing Unused Openings Including Providing Necessary Hardware Etc As Required , Supplying And Fixing Single Pole 5 A To 32 A Rating, 240V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 40A Double Pole Rccb With 30Ma Sensitivity Suitable For Operation 240V, 1Ph, 50Hz Ac Supply In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 16G Ms Sheet For Existing Db/Switch Box Including Cutting To The Required Shape And Size, Drilling, Painting, Providing Necessary Hardware For Fixing Etc As Required , Supplying And Fixing Of Gi Twin Bracket Suitable For Installation Of 30W/50W Led Street Light Made Of 50Mm Dia B Class Gi Pipe For Fixing On The Existing Pole And Extension For Mounting Of 2No Led Fittings With 32Mm Dia B Class Gi Pipe Of Suitable Length On Two Sides, Providing Nut Bolts With Top Cover I/C Cutting, Welding, Painting With Similar Colour, Fixing On Existing Pole Etc As Reqd , Supplying And Fixing Of 30W High Power Led Street Light Fitting Complete With All Accessories Suitable For 230V, 50Hz, Ac Supply, Fixing On The Existing Bracket, Interconnections, Transportation, Arranging Ladder Etc., As Reqd. (M/S Crompton Greaves Lsts-30-Cdl Or Ss Make) , Supplying & Connecting Of 3 Core 1.5Sq.Mm Pvc Insulated Pvc Round Sheathed Cable For Connecting From Pole Box To Street Light Fitting Etc Complete As Reqd. (M/S Havells/Polycab Or Ss Make) , Supplying And Fixing Of Weather Proof Smc Enclosure Of Size About 200Mm X 140Mm X 95Mm Deep (Nominal) With 1No 6 C Curve Sp Mcb With Din Channel, 6Way Bakelite Connector I/C Fixing On The Existing Cl , Etc As Reqd [M/S Sintex Or Similar Approved Make] , Disconnecting & Removing The Damaged Ms Box And Burnt Cable Along With Damaged End Terminations From The Existing Street Light Poles By Cutting The Gi Pipe Without Damaging The Cable Inside, Supplying And Fixing Of Suitable Size Support Made Of 20Mm X 5Mm (Nominal) Ms Flat To Match With The Size Of New Control Box, Fixing On The Existing Street Light Pole, Providing Necessary Hardware, Welding, Painting Etc As Reqd.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supplying and Replacing following Piano type switch/ socket/ electronic fan regulators/call bell on the existing switch box/junction box including removing the existing faulty switches, connections etc. as required. (Make: M/s Anchor or SS make) (a) 5/6 amps switch | Supplying and Replacing following Piano type switch/ socket/ electronic fan regulators/call bell on the existing switch box/junction box including removing the existing faulty switches, connections etc. as required. (Make: M/s Anchor or SS make) (a) 5/6 amps switch |
| 2 | b) 5/6A 2Way Switch | b) 5/6A 2Way Switch |
| 3 | c) 3 pin 5/6 A socket outlet | c) 3 pin 5/6 A socket outlet |
| 4 | d) 15/16 A switch | d) 15/16 A switch |
| 5 | e) 6 pin 15/16 A socket outlet | e) 6 pin 15/16 A socket outlet |
| 6 | f)100 Watt step type electronic Mini fan regulator | f)100 Watt step type electronic Mini fan regulator |
| 7 | g) PVC Angle/Batten holder | g) PVC Angle/Batten holder |
| 8 | h) Call bell | h) Call bell |
| 9 | i) 3 Pin Ceiling rose | i) 3 Pin Ceiling rose |
| 10 | j) 16A 3 Pin Plug top | j) 16A 3 Pin Plug top |
| 11 | Supplying and Replacing following MODULAR type switch/ socket/ electronic fan regulators/call bell on the existing switch board/junction box including connections etc. as required. (Make: M/s Anchor ROMA or SS make) (a) 10 amps switch | Supplying and Replacing following MODULAR type switch/ socket/ electronic fan regulators/call bell on the existing switch board/junction box including connections etc. as required. (Make: M/s Anchor ROMA or SS make) (a) 10 amps switch |
| 12 | b) 2 way 10 A switch | b) 2 way 10 A switch |
| 13 | c) 3 pin 6 A socket outlet | c) 3 pin 6 A socket outlet |
| 14 | d) 32 A DP switch | d) 32 A DP switch |
| 15 | e) 6 pin 6/16 A socket outlet | e) 6 pin 6/16 A socket outlet |
| 16 | f) 10 Bell push | f) 10 Bell push |
| 17 | Supplying & fixing following module surface/recess modular PVC/GI enclosure etc complete as reqd. (Make Anchor Roma or similar superior make) (a) 3 Module | Supplying & fixing following module surface/recess modular PVC/GI enclosure etc complete as reqd. (Make Anchor Roma or similar superior make) (a) 3 Module |
| 18 | b) 4 Module | b) 4 Module |
| 19 | c) 8 Module | c) 8 Module |
| 20 | Supplying & fixing following module cover plate on existing surface/recess modular PVC/GI enclosure etc complete as reqd. (Make Anchor Roma or similar superior make) (a) 3 Module | Supplying & fixing following module cover plate on existing surface/recess modular PVC/GI enclosure etc complete as reqd. (Make Anchor Roma or similar superior make) (a) 3 Module |
| 21 | b) 4 Module | b) 4 Module |
| 22 | c) 8 Module | c) 8 Module |
| 23 | Fixing of 24W 4ft LED batten on surface of wall/ceiling , connection from existing point etc complete as required | Fixing of 24W 4ft LED batten on surface of wall/ceiling , connection from existing point etc complete as required |
| 24 | Supplying and Fixing of foot lamp suitable for 230 volts 50Hz AC supply along with S/F 3mm thick (nominal) phenolic laminated sheet on the existing Ms enclosure etc complete as reqd (M/s Anchor Woods Foot Light LED White 3M or similar superior make) | Supplying and Fixing of foot lamp suitable for 230 volts 50Hz AC supply along with S/F 3mm thick (nominal) phenolic laminated sheet on the existing Ms enclosure etc complete as reqd (M/s Anchor Woods Foot Light LED White 3M or similar superior make) |
| 25 | Supplying and fixing 10W LED type polycarbonate bulkhead fitting including connections etc complete as reqd (M/s Crompton/Philips/Havells or SS Make) | Supplying and fixing 10W LED type polycarbonate bulkhead fitting including connections etc complete as reqd (M/s Crompton/Philips/Havells or SS Make) |
| 26 | Supplying and Fixing of 18W LED type round surface fitting made of polycarbonate suitable for 230 volts 50Hz AC supply etc complete as reqd (M/s Crompton or SS Make) | Supplying and Fixing of 18W LED type round surface fitting made of polycarbonate suitable for 230 volts 50Hz AC supply etc complete as reqd (M/s Crompton or SS Make) |
| 27 | Supplying and Fixing of 5W, 1' LED mirror light suitable for 230 volts 50Hz AC supply etc as reqd (M/s Crompton or SS make) | Supplying and Fixing of 5W, 1' LED mirror light suitable for 230 volts 50Hz AC supply etc as reqd (M/s Crompton or SS make) |
| 28 | Supplying and fixing 9W wall mounting LED decorative fitting suitable for operation on 230V, 1Ph, 50Hz AC supply including connections etc as required | Supplying and fixing 9W wall mounting LED decorative fitting suitable for operation on 230V, 1Ph, 50Hz AC supply including connections etc as required |
| 29 | Replacing the LED lamp in existing street light fitting with 22W LED bulb including dismantling the dome, fixing new bulb, cleaning the dome, fixing, arranging suitable ladder etc as required (M/s Crompton or similar superior make) | Replacing the LED lamp in existing street light fitting with 22W LED bulb including dismantling the dome, fixing new bulb, cleaning the dome, fixing, arranging suitable ladder etc as required (M/s Crompton or similar superior make) |
| 30 | Replacement and installation of 1200mm sweep ceiling fan suitable for working on 230V 50Hz AC supply, 1star rated, including removing of faulty fan etc as reqd.(M/s Crompton greaves or superior Make) | Replacement and installation of 1200mm sweep ceiling fan suitable for working on 230V 50Hz AC supply, 1star rated, including removing of faulty fan etc as reqd.(M/s Crompton greaves or superior Make) |
| 31 | Replacement and installation of 250mm sweep ventilation fan in washroom suitable for 1Phase, 230volts, 50Hz AC supply, & testing commissioning etc as required. (Make: Crompton/Havells or SS make) | Replacement and installation of 250mm sweep ventilation fan in washroom suitable for 1Phase, 230volts, 50Hz AC supply, & testing commissioning etc as required. (Make: Crompton/Havells or SS make) |
| 32 | Replacement and installation of 150mm sweep ventilation fan in washroom suitable for 1Phase, 230volts, 50Hz AC supply, & testing commissioning etc as required. (Make: Crompton/Havells or SS make) | Replacement and installation of 150mm sweep ventilation fan in washroom suitable for 1Phase, 230volts, 50Hz AC supply, & testing commissioning etc as required. (Make: Crompton/Havells or SS make) |
| 33 | Replacement and installation of 300mm sweep exhaust fan fan suitable for working on 230V 50Hz AC supply including removing the faulty fan, connections from existing point, testing etc as reqd (M/s Crompton greaves or superior Make) | Replacement and installation of 300mm sweep exhaust fan fan suitable for working on 230V 50Hz AC supply including removing the faulty fan, connections from existing point, testing etc as reqd (M/s Crompton greaves or superior Make) |
| 34 | Replacing the damaged louvers suitable for 300mm exhaust fan including removing the faulty louver, fixing etc as required | Replacing the damaged louvers suitable for 300mm exhaust fan including removing the faulty louver, fixing etc as required |
| 35 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/PVC casing & capping as required. a) 3 x 1.5 sq. mm | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/PVC casing & capping as required. a) 3 x 1.5 sq. mm |
| 36 | b) 3 x 2.5 sq. mm | b) 3 x 2.5 sq. mm |
| 37 | Supplying and fixing of following sizes of PVC casing and capping with all accessories etc as reqd. (Avonplast or SS Make) a) 20 x 10mm | Supplying and fixing of following sizes of PVC casing and capping with all accessories etc as reqd. (Avonplast or SS Make) a) 20 x 10mm |
| 38 | Replacing of storage type 25 litres capacity 5 star rated Vertical Geyser with inbuilt thermostat, cord wire and 3pin plug suitable for working on 230V 50Hz supply including inlet and outlet flexible braided water pipe, testing and connections etc as reqd.(M/s Racold CDR or similar superior make) | Replacing of storage type 25 litres capacity 5 star rated Vertical Geyser with inbuilt thermostat, cord wire and 3pin plug suitable for working on 230V 50Hz supply including inlet and outlet flexible braided water pipe, testing and connections etc as reqd.(M/s Racold CDR or similar superior make) |
| 39 | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.28x0.20m on the existing enclosure for closing unused openings including providing necessary hardware etc as required | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.28x0.20m on the existing enclosure for closing unused openings including providing necessary hardware etc as required |
| 40 | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.28x0.13m on the existing enclosure for closing unused openings including providing necessary hardware etc as required | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.28x0.13m on the existing enclosure for closing unused openings including providing necessary hardware etc as required |
| 41 | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.13x0.13m on the existing enclosure for closing unused openings including providing necessary hardware etc as required | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.13x0.13m on the existing enclosure for closing unused openings including providing necessary hardware etc as required |
| 42 | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.18x0.13m on the existing enclosure for closing unused openings including providing necessary hardware etc as required | Replacing the existing switch plate with 3mm thick (nominal) phenolic laminated sheet of size about 0.18x0.13m on the existing enclosure for closing unused openings including providing necessary hardware etc as required |
| 43 | Supplying and fixing SINGLE POLE 5 A to 32 A rating, 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. | Supplying and fixing SINGLE POLE 5 A to 32 A rating, 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 44 | Supplying and fixing 40A DOUBLE POLE RCCB with 30mA Sensitivity suitable for operation 240V, 1Ph, 50Hz AC supply in the existing MCB DB complete with connections, testing and commissioning etc. as required. | Supplying and fixing 40A DOUBLE POLE RCCB with 30mA Sensitivity suitable for operation 240V, 1Ph, 50Hz AC supply in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 45 | Supplying and fixing 16G MS Sheet for existing DB/Switch box including cutting to the required shape and size, drilling, painting, providing necessary hardware for fixing etc as required | Supplying and fixing 16G MS Sheet for existing DB/Switch box including cutting to the required shape and size, drilling, painting, providing necessary hardware for fixing etc as required |
| 46 | Supplying and fixing of GI Twin bracket suitable for installation of 30W/50W LED Street light made of 50mm dia B Class GI pipe for fixing on the existing pole and extension for mounting of 2no LED fittings with 32mm dia 'B' class GI Pipe of suitable length on two sides, providing nut bolts with top cover i/c cutting, welding, painting with similar colour, fixing on existing pole etc as reqd | Supplying and fixing of GI Twin bracket suitable for installation of 30W/50W LED Street light made of 50mm dia B Class GI pipe for fixing on the existing pole and extension for mounting of 2no LED fittings with 32mm dia 'B' class GI Pipe of suitable length on two sides, providing nut bolts with top cover i/c cutting, welding, painting with similar colour, fixing on existing pole etc as reqd |
| 47 | Supplying and Fixing of 30W high power LED street light fitting complete with all accessories suitable for 230V, 50Hz, AC supply, fixing on the existing bracket, interconnections, transportation, arranging ladder etc., as reqd. (M/s Crompton Greaves LSTS-30-CDL or SS make) | Supplying and Fixing of 30W high power LED street light fitting complete with all accessories suitable for 230V, 50Hz, AC supply, fixing on the existing bracket, interconnections, transportation, arranging ladder etc., as reqd. (M/s Crompton Greaves LSTS-30-CDL or SS make) |
| 48 | Supplying & connecting of 3 core 1.5sq.mm PVC insulated PVC round sheathed cable for connecting from pole box to street light fitting etc complete as reqd. (M/s Havells/Polycab or SS Make) | Supplying & connecting of 3 core 1.5sq.mm PVC insulated PVC round sheathed cable for connecting from pole box to street light fitting etc complete as reqd. (M/s Havells/Polycab or SS Make) |
| 49 | Supplying and Fixing of weather proof SMC enclosure of size about 200mm x 140mm x 95mm deep (nominal) with 1No 6Amp C curve SP MCB with din channel, 6way bakelite connector i/c fixing on the existing clamp, etc as reqd [M/s Sintex or similar approved make] | Supplying and Fixing of weather proof SMC enclosure of size about 200mm x 140mm x 95mm deep (nominal) with 1No 6Amp C curve SP MCB with din channel, 6way bakelite connector i/c fixing on the existing clamp, etc as reqd [M/s Sintex or similar approved make] |
| 50 | Disconnecting & removing the damaged MS Box and burnt cable along with damaged end terminations from the existing street light poles by cutting the GI pipe without damaging the cable inside, Supplying and fixing of suitable size support made of 20mm x 5mm (nominal) MS flat to match with the size of new control box, fixing on the existing street light pole, providing necessary hardware, welding, painting etc as reqd. | Disconnecting & removing the damaged MS Box and burnt cable along with damaged end terminations from the existing street light poles by cutting the GI pipe without damaging the cable inside, Supplying and fixing of suitable size support made of 20mm x 5mm (nominal) MS flat to match with the size of new control box, fixing on the existing street light pole, providing necessary hardware, welding, painting etc as reqd. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender