Rural Development Government Departments Closing in 8 days TDR #57273990

Tender For Infrastructure Development Of Diet Moirang, Bishnupur District, Manipur.

Issued by Government Departments · Imphal West, Manipur
Tender Value
9.09 Crore
Estimated cost
Bid Submission
14 Sep 2026
8 days left
EMD
18.19 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Imphal West → Manipur
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Infrastructure Development Of Diet Moirang, Bishnupur District, Manipur.

BOQ

Name of Work:- Infrastructure Development of DIET Moirang, Bishnupur District, Manipur.
Sl. No. Item Description
1A: Construction of Administrative Block.
2Sub- Head - Earth Work,
3Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
4(a) All kinds of soil
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6Supplying and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete.
7Sub- Head - Concrete & RCC Work,
8Providing and laying in position cement concrete in foundation and plinth excluding the cost of centering and shuttering. (a) 1:4:8 (1 cement : 4 c/sand : 8 graded stone aggregate. 40mm. nominal size).
9Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
10RCC work in wall (any thickness), including attached plasters, butressess, plinth and string courses, fillets, columns pillars, piers, abutments, posts, and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
11RCC work in beams suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases ends spiral staricase upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
12Sub- Head - Reinforcement Steel Work,
13Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
14(a) Thermo-Mechanically Treated bars
15Sub- Head - Form work
16Centering and shuttering including strutting, propping etc. and removal of form for:
17(a) Foundations, footings, bases of columns, etc. for mass concrete.
18(b) Suspended floors, roofs, landings, balconies and acess platform with water proof ply 12mm thick.
19(c) Columns, pillars, piers, abutments, post and struts.
20(d) Stairs, (excluding landings) except spiral-staircases.
21Sub- Head - Brick Work,
22Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1:4 (1 cement : 4 coarse sand)
23Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1 : 3 (1 cement : 3 coarse sand)
24Sub- Head -Wood Work,
25Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(a) Local best quality Teak wood
26Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(a) Local best quality Teak wood 35 mm thick shutters
27P/F in position collapsible steel shutters with vertical channels 20mm × 10 mm × 2 mm & braced with flats iron diagonals 20 mm × 5 mm sizes with top & bottom rails of T iron 40mm × 40 mm × 6 mm with 38 mm dia steel pullets complete with bolts and nuts, looking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
28Providing 40x5 mm. flat iron hold fast 40 cm i/c fixing toframed with 10mm dia. Bolt nuts windows plugs and enamelled in c. c.block 30x10x15 cm.1:3:6 (1 cement :3 coarse sand :6 graded stone aggrt 20mm nominal size).
29Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
30Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : (a) Local best quality Tolhao wood.
31P/F Aluminium sliding door bolts, ISI marked anodised ( anopdic coating not less then grade AC 10 as per IS : 1866 ) transperent or dyed to required colour or shade with nuts and screws etc complete
32(a)300 x 16 mm
33P/F Aluminium tower bolts , ISI marked anodised ( anopdic coating not less then grade AC 10 as per IS : 1866 ) transperent or dyed to required colour or shade with nuts and screws etc complete .
34(a)250 x 10 mm
35P/F Aluminium handles , ISI marked anodised ( anopdic coating not less then grade AC 10 as per IS : 1866 ) transperent or dyed to required colour or shade with nuts and screws etc complete . (a ) 125 mm.
36Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (a) Double charge vitrified tile polished finish of size. (i) Size of Tile 600 x 600 mm
379.21.2 P/F MS grills of required pattern to wooden frames of windows etc with M.S flats ,square or round bars etc. including priming coat with approved stell primer all complete . (a) Fixed to openings/wooden frames with rawl plugs screws etc.
38Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer -in-charge) with zinc coating 120 grams per sqm as per IS:277,in 240mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minium to avoid scratches during trasportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal,complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required with : Precoated galvanised iron profile sheets 0.50mm thick.
39Providing and fixing precoated galvanised steel sheets roofing accessories, Zinc coating 120gsm as per IS:277 in 240mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I.seam bolts and nuts,G.I.plain and bitumen washers complete: Ridges plain (500x600mm) Precoated galvanised iron profile sheets 0.50mm thick.
40Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately): (i) White face insulating board 12mm thick
4112mm cement plaster of mix : (a) 1:4( 1 cement : 4 fine sand)
4215mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) finishing with a floating coat of neat cement.
43Providing & applying white cement based putty of average thickness 1 mm , of approved brand and manufacture, over the plaster wall surface to prepare the surface even and smooth complete.
44Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work( hard and soft wood).
45Finishing walls with textured exterior paint of required shade ,(i) New work ( two or more coats applied @ 3.28 ltre/10 sqm ) over and including base coat of water proofing cement paint applied @ 2.2 kg/10 sqm.
46Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
47Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion. couple 75mm
48Providing and fixing M.S. holder bat clamps of approved design to C. I. or S.C.I, rain water pipes embedded in and including cement concrete blocks 1 Oxl Ox 10cm of 1 :2:4 mix {1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. (a) 100 mm dia
49Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
50B: Construction of Boys Hostel for DIET.
51Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5M including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50M
52(a) All kinds of soil.
53Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift
54Filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete.
55Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size )
565.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :5.1.1 1: 1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
57Centering and shuttering including strutting, propping etc. and removal of form for:
58a). Foundation, footing, bases of column etcand mass concrete.
59b). Column, pillar, posts and struts (square rectangle or polygon in plain).
60d). suspended floor,roofs landing balconies and access platform with water proof ply 12 mm thick
61f). Stairs ,(excluding landing )except sprial -Staircases
62Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement:(a) 1.5:3 (1 cement: 1. 5 coarse sand : 3 graded stone aggre gate 20 mm nominal size)
63Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
64Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up toplinth level.
65(a) Thermo-Mechanically Treated bars
66Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1:4 (1 cement : 4 coarse sand)
67Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1 : 3 (1 cement : 3 coarse sand)
68Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :
69(a) Local best quality Teak wood
70Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISi marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(a). Local best quality Teak wood(i) 35 mm thick shutters
71Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer.
72Providing & fixing ISI marked oxidised M.S. Sliding bolts with screws etc. Complete.(a) 250X16mm.
73Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :(a). 250x10mm
74Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :(a) 125 mm
75Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
76Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
77Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with(a) Precoated galvanised iron profile sheets 0.50 mm thick
78Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :(a) Ridges plain (500 - 600mm).(i) Precoated galvanised iron profile sheets 0.50 mm thick
79Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :(a) Local best quality Tolhao wood.
80Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately): (a) White face insulating board.(i) 12 mm thick
81Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(a) 40mm thick with 20mm nominal size stone aggregate.
82Cement plaster skirting (upto 30 cm height) with cement mortar 1: 3 (1 cement: 3coarse sand) finished with a floating coat of neat cement. (a) 18 mm thick.
8312mm cement plaster of mix : (a) 1:4( 1 cement : 4 fine sand)
8415 mm cement plaster on rough side of single or half brick wall of mix:-(a) 1: 4 (1 cement : 4 fine sand)
8515 mm cement plaster 1: 3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
86Painting with oil type wood preservative of approved brand and manufacture:(a) New work (Two or more coats)
87Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (a) Two or more coats on new work
88Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
89Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade(a) New work (two or more coats) over and including priming coat with cement primer:-
90Finishing walls with textured exterior paint of required shade :(a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
91Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.(a) In grating, frames, guard bar, railing, brackets, gates and similar works.
92Making plinth protection 50 mm cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggrt. of 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm niminal size well rammed ans consolidated and grouted with fine sand including finishing the top smooth.
93Construction of 2nd class brick mansonary 15cm vide open surface drain in CM 1:3 (1 cement: 3 C/S) i/c earth excavation 10 cm bed concrete 1:5:10 (1 cement: 5 c/s: 10 gr. St. aggrt. 40mm n/size) i/c 12mm thick cement plaster 1:3 (1 cement: 3 c/s) with a floating coat of neat cement inside and outside as per standard design
94C: Construction of Faculty Quarters of DIET.
95Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
96(a) All kinds of soil.
97Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m
98Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete.
99Centering and shuttering including strutting, propping etc. and removal of form for :
100(a) Foundations, footings, bases of columns etc. and mass concrete.
101(b) Suspended floors, roofs landings, balconies and access platform, with water proof ply 12 mm thick.
102( c) Lintels, Chajjas, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick.
103(d) Columns, Pillars, Piers, Abutments, Posts and Struts.
104(e) Stair case with sloping or stepped, soffits i/c raisers and stringers excluding landing
105(f) 5.9.18. Weather shade, Chajjas, corbels etc., including edges.
106Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level
107(a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size )
108Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:
109(a) 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size)
110Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement:
111(a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
112Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 :1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
113Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
114(a) Thermo-Mechanically Treated bars
115Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in :
116(a) Cement mortar 1:4 (1 cement : 4 coarse sand)
117Brick work with common burnt clay F.P.S. (non modular) bricks of class in superstructure above plinth level upto floor V level in all shapes and sizes in :
118(a) Cement mortar 1:4 (1 cement : 4 coarse sand)
119Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate. 20mm nominal size)
120Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
121(a) Local best quality Teak wood.
122Providing & fixing panelled or panelled and glazed shutters for doors, windows, clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
123(a) Local best quality Teak wood.
124(i) 35 mm thick shutters
125Providing and fixing curtain rods of 1.25mm thick chromium plated brass plate with two chromium plated brass brackets fixed with C.P brass screws and wooden plugs, etc, whenever necessary complete.
126(i) 25 mm dia
127Providing and fixing ISi marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
128(i) 250x10 mm
129(ii) 150x10 mm
130Providing and fixing ISi marked oxidised M.S. Handles conforming to I.S: 4992 with necessary screws etc complete:
131(i) 125mm
132Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
133(a) Fixed to openings /wooden frames with rawl plugs screws etc.
134Providing and fixing bright finished brass 100 mm mortice latch and lock, ISi marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete.
135Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
136(a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works .
137Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufactor) with water absortion less than 0.08% and conforming to IS: 15622 of approved make, in all colours and shade, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement :3 c/sand) joining with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. ( a ) Size of Tile 600x600mm
138Providing and fixing 10mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS: 4457 complete as per the direction of Engineer-in- Charge.
139(a) In dado/skirting on 12 mm thick mortar 1 :(1 acid proof cement: 4 coarse sand).(i). Acid and alkali resistant tile.
14012mm cement plaster of mix :-
141(a) 1:4 ( 1 cement : 4 coarse sand)
14215mm cement plaster of mix :-
1431:4 ( 1 cement : 4 coarse sand)
14416 mm cement plaster 1 :3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
145Painting with oil type wood preservative of approved brand and manufacturer:
146(a) Two or more coats on new work
147Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
148(a) Two or more coats on new work
149Applying priming coat:-
150(a) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works:-
151Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
152(a) Two or more coats on new work
153Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall nsurface to prepare the surface even and smooth complete.
154Finishing walls with textured exterior paint of required shade :
155(a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
156Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
157New work (two or more coats) over and i/c priming coat with cement primer.
158Making plinth protection 50 mm. in c.c. 1:3:6 (1 cement : 3 course sand : 6 graded stone aggrt. 20 mm. nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finished the top smooth.
159Construction of 2nd class brick masonry 15cm vide open surface drain in CM 1:3 (1 cement: 3 C?S) i/c earth excavation 10 cm bed concrete 1:5:10 ( 1 cement: 5c/s : 10 gt. St. aggrt. 40mm n/size) i/c 12mm thick cement plaster 1:3 ( 1 cement: 3 c/s) with a floating coat of neat cement inside and outside as per standard design.
160D: Construction of Boundary Wall, Gate with Security Post & Fencing in the Outer Land( Existing)
161Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
162(a) All kinds of soil
163Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
164Providing and laying in position cement concrete in foundation and plinth excluding the cost of centering and shuttering. (a) 1:4:8 (1 cement : 4 c/sand : 8 graded stone aggregate. 40mm. nominal size).
165Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1 : 3 (1 cement : 3 coarse sand)
166Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
167RCC work in beams suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases ends spiral staricase upto floor five level excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
168RCC work in wall (any thickness), including attached plasters, butressess, plinth and string courses, fillets, columns pillars, piers, abutments, posts, and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
169Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. (a) Thermo-Mechanically Treated bars.
170Centering and shuttering including strutting, propping etc. and removal of form for:
171(a) Foundations, footings, bases of columns, etc. for mass concrete.
172(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
173( c) Lintels, beams, plinth beams, girders, bressumers and sqm cantilevers.
17412 mm cement plaster of mix : (a) 1:4 (1 cement : 4 fine sand).
17515 mm cement plaster on rough side of single or half brick wall of mix :(a) 1:4 (1 cement: 4 coarse sand)
176Colour washing such as green, blue or buff to give an even shade :(a) New work (two or more coats) with a base coat of white washing with lime
177Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
178Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5 x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with(i) Precoated galvanised iron profile sheets 0.50 mm thick
179Providing and fixing 1 mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer.
180E: Construction of Principal Quarter.
181Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
182(a) All kinds of soil
183Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
184Supplying and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete.
185Providing and laying in position cement concrete in foundation and plinth excluding the cost of centering and shuttering. (a) 1:4:8 (1 cement : 4 c/sand : 8 graded stone aggregate. 40mm. nominal size).
186Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
187Centering and shuttering including strutting, propping etc. and removal of form for:
188(a) Foundations, footings, bases of columns, etc. for mass concrete.
189(b) Columns, pillars, piers, abutments, post and struts.
190(c) Suspended floors, roofs, landings, balconies and acess platform with water proof ply 12mm thick.
191RCC work in wall (any thickness), including attached plasters, butressess, plinth and string courses, fillets, columns pillars, piers, abutments, posts, and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
192RCC work in beams suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases ends spiral staricase upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
193Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
194(a) Thermo-Mechanically Treated bars
195Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1:4 (1 cement : 4 coarse sand)
196Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1 : 3 (1 cement : 3 coarse sand)
197Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(a) Local best quality Teak wood
198Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(a) Local best quality Teak wood 35 mm thick shutters
199Providing and fixing ISI marked oxidised M.S. sliding door bolts with screws etc. complete :(a) 250x16 mm
200Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete: (a) 250x10mm
201Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (a) 125 mm
202Providing 40x5 mm flat iron hold fast 40 cm long including fixing each to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1 :3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
203Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
204Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5 x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with(i) Precoated galvanised iron profile sheets 0.50 mm thick
205Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :(a) Precoated galvanised iron profile sheets 0.50 mm thick
206Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :(a) Local best quality Tolhao wood
207Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately):(a) White face insulating board 12 mm thick
208Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (i) 40mm thick with 20mm nominal size stone aggregate.
209Cement plaster skirting (upto 30 cm height) with cement mortar 1 :3 (1 cement: 3coarse sand) finished with a floating coat of neat cement.(a) 18 mm thick.
21012 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand).
21115 mm cement plaster of mix 1:4 (1 cement : 4 fine sand).
21215 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement.
213Painting with oil type wood preservative of approved brand and manufacture:(a) New work (Two or more coats)
214Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:(a) Two or more coats on new work
215Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
216Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :(a) New work (two or more coats) over and including priming coat with cement primer:-
217Finishing walls with textured exterior paint of required shade : (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
218Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 c : 3 c/s : 6 g/ stone aggrtgate 20 mm nominal size)
219Construction of 2nd class brick masonry 15 cm vide open surface drain in CM 1:3 (1 cement : 3 C/S) i/c earth excavation 10 cm bed concrete 1:5:10 (1 cement: 5 c/s : 10 graded stone aggrt. 40mm nominal size) i/c 12mm thick cement plaster 1:3 (1 cement : 3 c/s) with a floating coat of neat cement inside and outside as per standard design.
220F: Construction of Chowkidar Quarter.
221Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
222(a) all kinds of soil
223Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
224Supplying and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete.
225Providing and laying in position cement concrete in foundation and plinth excluding the cost of centering and shuttering. (a) 1:4:8 (1 cement : 4 c/sand : 8 graded stone aggregate. 40mm. nominal size).
226Centering and shuttering including strutting, propping etc. and removal of form for:
227(a) Foundations, footings, bases of columns, etc. for mass concrete.
228(b) Columns, pillars, piers, abutments, post and struts.
229(c) Suspended floors, roofs, landings, balconies and acess platform with water proof ply 12mm thick.
230(d) Weather shadde, Chajjas. corbels etc.
231Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
232RCC work in beams suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases ends spiral staricase upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
233RCC work in wall (any thickness), including attached plasters, butressess, plinth and string courses, fillets, columns pillars, piers, abutments, posts, and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
234Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
235(a) Thermo-Mechanically Treated bars
236Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1:4 (1 cement : 4 coarse sand)
237Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1 : 3 (1 cement : 3 coarse sand)
238Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(i) Local best quality Teak wood
239Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(a) Local best quality Teak wood 35 mm thick shutters
240Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
241Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :(a) Local best quality Tolhao wood
242Providing and fixing ISI marked oxidised M.S. sliding door bolts with screws etc. complete(i) 250x16 mm
243Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :(i) 250x10mm
244(ii) 100x10
245Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frames with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm 1 :3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize)
246Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (i) 125 mm
247Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.(a) Fixed to openings /wooden frames with rawl plugs screws etc.
248Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (i) 40mm thick with 20mm nominal size stone aggregate.
249Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinccoating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. Thesheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal,complete upto any pitch in horizontal/ verticalor curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with
250(i) Precoated galvanised iron profile sheets 0.50 mm thick
251Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated Jor L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :
252(i) Precoated galvanised iron profile sheets 0.50 mm thick
253Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately): (i) White face insulating board 12 mm thick
25412mm cement plaster of mix : 1:4 (1 cement : 4 fine sand).
25515mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of heat cement on the roughside of single or hall brick.
256Providing and applying white cement based putty of average thickness1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
257Finishing walls with Acrylic exterior paint of required shade :(i) New work (Two or more coats applied @ 1.67 ltr/ 10 sqm.over and including base coat of water proofing cement paint applied @2.20 kg/ 10 sqm).
258Finishing walls with textured exterior paint of required shade :(i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @2.20kg/10 sqm.
259G: Construction of Vehicle Parking for DIET.
260Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1. 5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
261(a) All kinds of soil.
262Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m
263Supplying and filling in plinth with sandy soil under floors including, watering. Ramming consolidating and dressing complete.
264Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level
265(a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size )
266(a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size )
267Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:
268(a) 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size)
269Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 :1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
270Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement:
271(a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
272Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
273(a) Thermo-Mechanically Treated bars
274Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level.
275(a) Thermo-Mechanically Treated bars
276Centering and shuttering including strutting, propping etc. and removal of form for:
277(a) Foundation footings, bases of columns etc. and mass concrete.
278(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
279(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick.
280Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in :
281(a) Cement mortar 1:4 (1 cement : 4 coarse sand)
282Brick work with common burnt clay F.P.S. (non modular) bricks of class in superstructure above plinth level upto floor V level in all shapes and sizes in :
283(a) Cement mortar 1:4 (1 cement : 4 coarse sand)
284Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in .
285(a) Cement mortar 1:3 (1 cement : 3 coarse sand)
286Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.
287(a) Hot finished welded type tubes
288Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grames per sqm as IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scrates during transportation and should be supplied in single length upto 12 metre or as desire by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with
289(a) Precoated galvanised iron profile sheets 0.50 mm thick.
290Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS : 277, in 240 mpa steel grade, 5-7 microns epoxy primer on on both side of the sheet and polyester top coat 15-18 microns using self drilling / self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I plain and bitumen washers complete :
291(a) Ridge plain (500 - 600)
292(i) Precoated galvanised iron profile sheets 0.50 mm thick.
29312mm cement plaster of mix :-
294(a) 1:4 ( 1 cement : 4 fine sand)
29515 mm cement plaster 1 :3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
296Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. .
297Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
298(a) New work (two or more coats) over and including priming coat with cement primer:-
299H: Construction of Cafeteria for DIET
300Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
301(a) All kinds of soil
302Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
303Supplying and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete.
304Providing and laying in position cement concrete in foundation and plinth excluding the cost of centering and shuttering. (a) 1:4:8 (1 cement : 4 c/sand : 8 graded stone aggregate. 40mm. nominal size).
305Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
306RCC work in wall (any thickness), including attached plasters, butressess, plinth and string courses, fillets, columns pillars, piers, abutments, posts, and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
307RCC work in beams suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases ends spiral staricase upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
308Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
309(a) Thermo-Mechanically Treated bars
310Centering and shuttering including strutting, propping etc. and removal of form for:
311(a) Foundations, footings, bases of columns, etc. for mass concrete.
312(b) Suspended floors, roofs, landings, balconies and acess platform with water proof ply 12mm thick.
313(c) Columns, pillars, piers, abutments, post and struts.
314Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1:4 (1 cement : 4 coarse sand)
315Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: (a) Cement mortar 1 : 3 (1 cement : 3 coarse sand)
316Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(a) Local best quality Uningthou wood
317Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(a) Local best quality Teak wood 35 mm thick shutters
318Providing 40x5 mm flat iron hold fast 40 cm long including fixing each to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1 :3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
319Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :(a) Local best quality Uningthou wood
320Providing and fixing ISI marked oxidised M.S. sliding door bolts with screws etc. complete :(a) 250x16 mm
321Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:
322(a) 250x10mm
323(b) 150x10mm
324Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
325(a) 125 mm
326(b) 100 mm
327Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(a) 40mm thick with 20mm nominal size stone aggregate.
328Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.(a) Fixed to openings /wooden frames with rawl plugs screws etc.
329Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5 x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with(i) Precoated galvanised iron profile sheets 0.50 mm thick
33012.46.3 Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :(a) Precoated galvanised iron profile sheets 0.50 mm thick
33112.22.2 Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately):(a) White face insulating board 12 mm thick
33212 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand).
33315 mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement.
33413.58 Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
33513.27.1 Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
33613.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :(a) New work (Two or more coats) over and including priming coat with cement primer :-
33710.16.1Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
338I: Construction Rain Water Harvesting System
339A - Construction of Water Reservoir:
340Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
341(a) All kinds of soil
342Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
343Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stoneaggregate. 40mm. nominal size))
344RCC work in beams suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases ends spiral staricase upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
345Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
346RCC work in wall (any thickness), including attached plasters, butressess, plinth and string courses, fillets, columns pillars, piers, abutments, posts, and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
347Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars.
348Centering and shuttering including strutting, propping etc. and removal of form for:
349(a) Suspended floors, roofs, landings, balconies and acess platform with water proof ply 12mm thick.
350(b) Foundations, footings, bases of columns, etc. for mass concrete.
351(c) Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc.
352B - Construction of Overhead Tank:
353Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
354(a) All kinds of soil
355Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
356Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level:
357(a) 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate cum 40 mm nominal size)
358Centering and shuttering including strutting, propping etc. and removal of form for:
359(a) Foundations, footings, bases of columns, etc. for mass concrete.
360Providing and laying in position specified grade of RCC, excluding the cost of centering, shutter, finishing and reinforcement. All work upto plinth level.(a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm nominal size)
361Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.(a) In grating, frames, guard bar, railing, brackets, gates and similar works.
362Providing and placing on terrace (at all floor levels) polyethylene per Rs. 11.30 water storage tank, IS : 12701 marked, with cover and suitable locking litre arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
363P & F Polyethelene Aluminium Polyethelene PEAL-PE Composite Pressure Pipes conforming to IS- 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 800C including all special fitings of composite material (engineering plastic blend and brass inserts wherever required) eg. elbows, tess, reducers couplers, refilling and testing of joints completes as per direction of the engineer in charge. EXTERNAL WORK
364(a) 2532 (32mm OD) Pipe
365(b) 4050 ( 50mm OD) Pipe Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57273990
AUTHORITY Government Departments
TENDER VALUE 9.09 Crore
LAST DATE 14-09-2026
Authority
Authority Name Planning And Development Department
Work Description Tender for Infrastructure Development Of Diet Moirang, Bishnupur District, Manipur.
Basic Detail
Tender No No. EE-II-PDA/NIT/2026-27/3
Bidding Type Tender
Location
City Imphal West
State Manipur
Key Dates
Publish Date 31 Aug 2026
Submission Date 14 Sep 2026
Open Date 14 Sep 2026
Finance
Tender Value 9.09 Crore
Tender Fee 5000
EMD 18.19 Lakhs
Exemption Not Available
Document List
5c735cc5-cf5b-4b20-b270-8e4435d06e22.html
BOQ_3760.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

5c735cc5-cf5b-4b20-b270-8e4435d06e22.html

xls

BOQ_3760.xls

pdf

Tendernotice_1.pdf

Disclaimer