Tender For Replacement /Maint Of Re-Wiring Alongwith Modular Fitting And Allied Works Under Ge Clement Town.
Tender Overview
Project Description
Tender for Replacement /Maint Of Re-Wiring Alongwith Modular Fitting And Allied Works Under Ge Clement Town.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Sep-2026 |
| 2 | 14-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches,sockets, ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc |
| 2 | Taking down carefully unserviceable MCB/TPN DBs of any type/size with MCBs and disconnecting and making good disturbed surfaces complete all as directed. |
| 3 | M & L for complete point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn in and including surface/concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engr In Charge for the following :- |
| 4 | All as per item No 3 above but for multi 5 pin 5 amp socket outlet on same board ISI marked complete all as specified and directed |
| 5 | All as per item No 3 above but for multi 5 pin socket outlet 5 amp socket on independent board ISI marked complete all as specified and directed |
| 6 | All as per item No 3 above but for One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 Sq. mm size |
| 7 | All as per item No 3 above but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 sqmm copper conductor multistrand cable pvc insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsheathed copper conductor multistranded cable 2.5 sqmm as earth wire FRLS pvc insulated in green color all as directed by Engr-in-charge. |
| 8 | Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel sunken / terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. |
| 9 | Description same as per Ser Item No 08.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed. |
| 10 | Description same as per Ser Item No 08.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed. |
| 11 | Description same as per Ser Item No 08.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed. |
| 12 | S&F of Modular Socket, 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and directed |
| 13 | S&F of Modular switch 1 module 6A,1 module , 240 volts ISI marked complete all as specified and directed |
| 14 | S&F of Modular bell push 6A, 1 module , 240 volts ISI marked complete all as specified and directed |
| 15 | S&F of ceiling rose, 3 Pin/PVC/polycarbonate isolated body ISI marked complete all as specified and directed |
| 16 | S&F of Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed |
| 17 | S&F of Modular Socket 6A/16A - 6 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed |
| 18 | S&F of Calling bell Ding Dong/buzzer AC 230 Volts, single pole ISI marked complete all as specified and directed |
| 19 | M& L of Lamp holder, Modular type, PVC/Polycarbonate type with back plate suitable for batten fittings |
| 20 | Supply and fixing of Fan step regulator, 100W - 1 module 240 volts ISI marked complete all as specified and directed |
| 21 | S & F Moduler Distribution box MCB Protected socket with Plastic enclosure ,Surface/concealed mounting, 20 Amp MCB DBOXX Combo DP including Plug top with indicator all as specified and directed. |
| 22 | Supply and fixing Distribution box Indostrial type single pole and neutral enclosure with a two pole and earth plug & socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC all as specified. |
| 23 | S&F in repair LED lights fitting 1x 22W, 220V, AC decorative box type complete with LED 20 watts driver, holder and power factor >0.9, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 24 | S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED 18 watts driver, holder and power factor >0.9, 100 Lumen/Watt, 3000 to 4500 K WW type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 25 | S&F in repair LED lights fitting 1x 18W, 220V, AC decorative box type complete with LED 18 watts driver, holder and power factor >0.9, 100 Lumen/Watt, 3000 to 4500 K WW type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 26 | S&F of Vertical Distribution Board (V.TP&N) 4 way double door suitable for TPN 4 pole 125 Amp 16 KA four pole as incomer, it should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar all as specified and directed. |
| 27 | M&L in repair Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion. |
| 28 | S & F in repair LED light fitting 10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 29 | Supply and fixing of 415V 10 KA 'B' curve miniature circuit breaker (MCB) TPN 4P, 32 Amp to125 Amp of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by EIC. |
| 30 | Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge. |
| 31 | Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge. |
| 32 | Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge. |
| 33 | Material and labour in repair for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. |
| 34 | Material and labour in repair for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. |
| 35 | Material and labour in repair for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 2.5 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. |
| 36 | Supply and fixing in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable and flexible pipe of suitable size complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 37 | Supply and fixing in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable and flexible pipe of suitable size complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender