Housing Urban and Rular Development Local Bodies Closing in 1 days TDR #57273776

Tender For maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh : repair maintenance Of Water Fountain With Multicolour Rgb Led Lights And Iei Work At Shaheed Chandra Shekhar Park, Saraswati Vihar Under Hd-2, Horticulture Zone

Issued by Local Bodies · Delhi, Delhi
Tender Value
12.99 Lakhs
Estimated cost
Bid Submission
05 Sep 2026
1 days left
EMD
25984
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh : repair maintenance Of Water Fountain With Multicolour Rgb Led Lights And Iei Work At Shaheed Chandra Shekhar Park, Saraswati Vihar Under Hd-2, Horticulture Zone.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Sep-2026 Corrigendum Other 05-Sep-2026

BOQ

Name of Work:- M/o Completed Scheme under Nazul Account-II, Horticulture Zone.SH : RMO of Water Fountain with Multicolour RGB LED Lights and IEI Work at Shaheed Chandra Shekhar Park, Saraswati Vihar under HD-2, Horticulture Zone.
Sl. No. Item Description
1Routine Maintenance & Operation of Fountain and other Electrical & Mechanical equipment’s associated with Fountain as per Terms & Condition attached.
2Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required.2C x 16 sq. mm
34C x 25 sq. mm
4Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the Existing RCC/HUME/METAL Pipe as required.Up to 35 sq. mm
5Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD-63 mm & ID-51 mm nominal)
6Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
7Supplying, Installation, Testing and Commissioning of 45-Watt Ruby NXT and GENS LED Post Top with Die Cast Aluminium housing for Gate Light mounted along with CCT-5700 K having Potted Driver, Symmetric Beam, Top Opening (TO) Driver Compartment, Polycarbonate Diffuser, CRI>70, IP-66 complete in all respect including connections with 1.5 sq. mm FRLS, PVC Insulated Copper conductor single core cable and earthing, suitable accessories (like Bracket, nut, bolt) etc. as required.
8Supplying and Embedding following dia. GI Pipe (Medium Class) in Pole Collar/Foundation (during casting) for Cable Entry including bending the Pipe to the required shape complete as required.40 mm dia.
9Wiring for Light Point/Fan Point/Exhaust Fan Point/Call Bell Point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed Medium Class PVC Conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
10Wiring for Circuit/Sub-Main Wiring along with Earth Wire with the following size of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed Medium Class PVC Conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm Earth Wire
11Wiring for Light/Power Plug with 2 x 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed Medium Class PVC Conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for Loop Earthing as required.
12Supplying and Fixing following way, Single Pole and Neutral, Sheet Steel, MCB Distribution Board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way, Double Door
13Supplying and Fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole
14Double Pole
15Supplying and Fixing suitable size GI Box with Modular Plate and Cover in front on surface or in recess, including Providing and Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet and 15/16 A Modular Switch, connections etc. as required.
16Supplying, Installation, Testing & Commissioning of LED Surface mounted Batten Light of following body material and construction as per IS: 10322 with Driver (Replceable) as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 40°C, Internal Surge Protection of 2.5 KV with Short & Open Circuit Protection, THD<10%, PF≥0.95, IP-20, CRI>80, Flicker Free (Flicker should be below 5%), life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard and Trademark Certificate (TC) Manufacturers Word Mark/Name Engraved/Embossing/Screen Printing on housing. OEM must have its own in house NABL Lab setup for all testing facilities for LED Fixtures. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM Warranty. System Lumen Efficacy>105<120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).Powder Coated Die Cast/Extruded Aluminium Body (Thickness>120 mm).18-22 Watt
17Supplying, Installation, Testing & Commissioning of Flood Light, Powder Coated Pressure Die Cast Aluminum body with built in or separate driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2, PF≥0.95, IP-66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC as per CISPR-15, Lenses for Beam Angle 30°-120° as per the application and the project requirement, suitable tilt able Fitting, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq. mm FRLS/HFFR, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).50 Watt
18Supplying, Installation, Testing & Commissioning of Ceiling Fan with Brush Less Direct Current (BLDC) Motor, Class of Insulation: B, 3 Nos. Metal (Aluminium Alloy) blades, 30 cm long down road, 2 Nos. canopies, Shackle kit, safety rope, copper winding, Steel/AI Body, Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD<10%, suitable for operation with Regulator for Speed Control and all remaining accessories including safety pin, nut bolts, washers, Temperature rise=75°C (Max.), Insulation Resistant more than 2 Mega Ohm, suitable for 230 V, 50Hz, Single Phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.1200 mm, Service Value>6.0 CM/Min/Watt, Air Delivery 210 CM/Min (minimum)
19Supplying and Fixing of SS Size-II Enclosure for 3P/4P MCCB suitable to accommodate up to 3.5C x 185 sq. mm Aluminium Armoured Cable along with In-built Neutral Link for TPN System, IK08, IP-30 Protection, Space for Cable termination, Louvers for better heat dissipation, mounting holes for wall mounting i/c connection, testing etc. complete as required.
20Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
21Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57273776
AUTHORITY Local Bodies
TENDER VALUE 12.99 Lakhs
LAST DATE 05-09-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Completed Scheme Under Nazul Account-Ii, Horticulture Zone.Sh : repair maintenance Of Water Fountain With Multicolour Rgb Led Lights And Iei Work At Shaheed Chandra Shekhar Park, Saraswati Vihar Under Hd-2, Horticulture Zone.
Basic Detail
Tender No 37/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 03 Sep 2026
Submission Date 05 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 12.99 Lakhs
Tender Fee Ref. Documents
EMD 25984
Exemption Available
Document List
BOQ_971185.xls
c38793e1-9dd3-49f2-96fd-b933dc0d6c05.html
NIT37.pdf
TenderNotice37.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 05, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Sep 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
xls

BOQ_971185.xls

html

c38793e1-9dd3-49f2-96fd-b933dc0d6c05.html

pdf

NIT37.pdf

pdf

TenderNotice37.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders