Tender For Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-1 And 2 Dda Flat Bps Jasola Vihar In Okhla Constituency Ac-54.
Tender Overview
Project Description
Tender for Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-1 And 2 Dda Flat Bps Jasola Vihar In Okhla Constituency Ac-54. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2 Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminium. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5 Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire. The Panel Size Must Be Of 2000Mm X 2000Mm X 450Mm. Mounted On Ms Angle Having 4 Legs Of 1 Feet Height. , Mccb 250 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader& Handle Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mccb 125 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mccb 415V, 4 Pole, 3 Phase 50Ka 50Hz, 63 annual periodical maintenance With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mcb Single Pole 6 Amp. Make:- L&T/Havells/Schneider/ Djb Approved , Mcb Triple Pole 32 Amp. Make :-L&T/Havells/ Djb Approved , Mcb Triple Pole 63 Amp. Make:- L&T/Havells/ Djb Approved , Power Capacitors(Heavy Duty) 415V Unit Of 20 Kvar Make:- Havells /L&T/ Djb Approved , Shunt Power Capacitors(Heavy Duty) 415V Unit Of 5 Kvar Make :- Havells /L&T/ Djb Approved , Over Load Relay 42-69 annual periodical maintenance Make:-L&T/Siemens/ Djb Approved , Over Load Relay 14-23 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Over Load Relay 6-9 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Digital Amp. Meter Make Ae/L&T/ Djb Approved , Digital Volt Meter 0-500V .Make:- Ae/L&T/ Djb Approved , Motor Protection/Phase Failure Relay Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 70 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 50 Amp. Make:-L&T/Siemens/Djb Approved , Power Contactor 220V 3Phase 40 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 25 Amp. Make:- L&T/Siemens/ Djb Approved , Star Delta Timer On Delay. Make:- L&T/Siemens/ Djb Approved , Indicating Lights Led Type Ryb & On/Off Make:-L&T/Havells/ Djb Approved , Supply Of On / Off Push Button. Make:- L&T/Havells/ Djb Approved , Current Transformer 200/5, 100/5 & 30/5. Make:- Ae /Advance/ Djb Approved , On Load Change Over Switch 250 Amp. 415V, Open Execution Type Make:- L&T/Havells/C&S/ Djb Approved , Supply Of 95 Sq Mm X 3.5 Core Aluminium Armoured Cable . Make: Grandlay/Havells/Djb Approved , Supply Of Flexible Copper Cable 35 Sq Mm Single Core. Make: Grandlay/Havells/Djb Approved , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares, Control Wiring In 1.5 Sq. Mm, 2.5 Sq.Mm , 4.00 Sq.Mm & 6 Sqm Wire Complete In All Respect. Job Including Making Of Star Delta Starter Provision In Panel (3 Nos). , Dismantling Of Old Panel, Structure, Damaged Components And Installation Of New Panel At Site By Making Foundation, Termination Of Cable Both Incoming And Outgoing Side, Including Cable Connections. This Includes Cartage ,Loading And Unloading By Crane Or Heavy Labour Etc. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia. G.I. Pipe From Earth Electrode Including Connection With G.I. Nut Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow :- I) Continuity And Earth Testing Ii) Meggaring Of All Equipments For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. Iii) Checking For All Tightness Of Nut And Bolts. Iv) Alignments Of Doors Etc. V) Interlocking Tests. Vi) All Function Tests.
BOQ
| Sl. No. | Item Description |
| 1 | LT Distribution panel sheet steel enclosure made out of 2 mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminium. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 mm cross section. Each wire will be terminating with a ferule crimped to the wire. The panel size must be of 2000MM X 2000MM X 450MM. mounted on MS angle having 4 legs of 1 feet height. |
| 2 | MCCB 250 Amp. 4 Pole 3phase High breaking capacity 50KA 50Hz, 430V with spreader& Handle Make : L&T/Siemens/Schneider/Havells/DJB approved make.. |
| 3 | MCCB 125 Amp. 4 Pole 3phase High breaking capacity 50KA 50Hz, 430V with spreader & Handle. Make : L&T/Siemens/Schneider/Havells/DJB approved make.. |
| 4 | MCCB 415V, 4 Pole, 3 phase 50KA 50Hz, 63 Amp with spreader & handle. Make : L&T/Siemens/Schneider/Havells/DJB approved make.. |
| 5 | MCB Single pole 6 Amp. Make:- L&T/Havells/Schneider/ DJB approved |
| 6 | MCB Triple pole 32 Amp. Make :-L&T/Havells/ DJB approved |
| 7 | MCB Triple pole 63 Amp. Make:- L&T/Havells/ DJB approved |
| 8 | Power capacitors(Heavy Duty) 415V unit of 20 Kvar Make:- Havells /L&T/ DJB approved |
| 9 | Shunt Power capacitors(Heavy Duty) 415V unit of 5 Kvar Make :- Havells /L&T/ DJB approved |
| 10 | Over load relay 42-69 Amp Make:-L&T/Siemens/ DJB approved |
| 11 | Over load relay 14-23 Amp Make:- L&T/Siemens DJB approved |
| 12 | Over load relay 6-9 Amp Make:- L&T/Siemens DJB approved |
| 13 | Digital Amp. Meter Make AE/L&T/ DJB approved |
| 14 | Digital Volt Meter 0-500V .Make:- AE/L&T/ DJB approved |
| 15 | Motor protection/Phase failure Relay Make:- L&T/Siemens/ DJB approved |
| 16 | Power contactor 220V 3phase 70 Amp. Make:- L&T/Siemens/ DJB approved |
| 17 | Power contactor 220V 3phase 50 Amp. Make:-L&T/Siemens/DJB approved |
| 18 | Power contactor 220V 3phase 40 Amp. Make:- L&T/Siemens/ DJB approved |
| 19 | Power contactor 220V 3phase 25 Amp. Make:- L&T/Siemens/ DJB approved |
| 20 | Star delta timer on delay. make:- L&T/Siemens/ DJB approved |
| 21 | Indicating lights LED type RYB & On/OFF Make:-L&T/Havells/ DJB approved |
| 22 | Supply of ON / OFF Push Button. make:- L&T/Havells/ DJB approved |
| 23 | Current Transformer 200/5, 100/5 & 30/5. Make:- AE /Advance/ DJB approved |
| 24 | On load change over switch 250 Amp. 415V, Open execution type Make:- L&T/Havells/C&S/ DJB approved |
| 25 | Supply of 95 sq mm x 3.5 core aluminium armoured cable . Make: Grandlay/Havells/DJB approved |
| 26 | Supply of flexible Copper cable 35 sq mm single core. Make: Grandlay/Havells/DJB approved |
| 27 | Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares, control wiring in 1.5 sq. mm, 2.5 sq.mm , 4.00 sq.mm & 6 sqm wire complete in all respect. Job including making of star delta starter provision in panel (3 Nos). |
| 28 | Dismantling of old panel, structure, damaged components and installation of new panel at site by making foundation, termination of cable both incoming and outgoing side, including cable connections. This includes cartage ,loading and unloading by crane or heavy labour etc. |
| 29 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia. G.I. pipe from earth electrode including connection with G.I. nut bolt, spring, washer excavation and re-filling etc. as required. |
| 30 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 31 | Testing & commissioning of panel, as per required parameters with relevant IS. Testing of the panel prior to switching on as follow :- i) Continuity and earth testing ii) Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth.iii) Checking for all tightness of nut and bolts.iv) Alignments of doors etc.v) Interlocking tests. vi) All function tests. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender