Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 3 days TDR #57273754

Tender For Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-1 And 2 Dda Flat Bps Jasola Vihar In Okhla Constituency Ac-54.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
3 days left
EMD
12300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-1 And 2 Dda Flat Bps Jasola Vihar In Okhla Constituency Ac-54. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2 Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminium. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5 Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire. The Panel Size Must Be Of 2000Mm X 2000Mm X 450Mm. Mounted On Ms Angle Having 4 Legs Of 1 Feet Height. , Mccb 250 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader& Handle Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mccb 125 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mccb 415V, 4 Pole, 3 Phase 50Ka 50Hz, 63 annual periodical maintenance With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mcb Single Pole 6 Amp. Make:- L&T/Havells/Schneider/ Djb Approved , Mcb Triple Pole 32 Amp. Make :-L&T/Havells/ Djb Approved , Mcb Triple Pole 63 Amp. Make:- L&T/Havells/ Djb Approved , Power Capacitors(Heavy Duty) 415V Unit Of 20 Kvar Make:- Havells /L&T/ Djb Approved , Shunt Power Capacitors(Heavy Duty) 415V Unit Of 5 Kvar Make :- Havells /L&T/ Djb Approved , Over Load Relay 42-69 annual periodical maintenance Make:-L&T/Siemens/ Djb Approved , Over Load Relay 14-23 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Over Load Relay 6-9 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Digital Amp. Meter Make Ae/L&T/ Djb Approved , Digital Volt Meter 0-500V .Make:- Ae/L&T/ Djb Approved , Motor Protection/Phase Failure Relay Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 70 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 50 Amp. Make:-L&T/Siemens/Djb Approved , Power Contactor 220V 3Phase 40 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 25 Amp. Make:- L&T/Siemens/ Djb Approved , Star Delta Timer On Delay. Make:- L&T/Siemens/ Djb Approved , Indicating Lights Led Type Ryb & On/Off Make:-L&T/Havells/ Djb Approved , Supply Of On / Off Push Button. Make:- L&T/Havells/ Djb Approved , Current Transformer 200/5, 100/5 & 30/5. Make:- Ae /Advance/ Djb Approved , On Load Change Over Switch 250 Amp. 415V, Open Execution Type Make:- L&T/Havells/C&S/ Djb Approved , Supply Of 95 Sq Mm X 3.5 Core Aluminium Armoured Cable . Make: Grandlay/Havells/Djb Approved , Supply Of Flexible Copper Cable 35 Sq Mm Single Core. Make: Grandlay/Havells/Djb Approved , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares, Control Wiring In 1.5 Sq. Mm, 2.5 Sq.Mm , 4.00 Sq.Mm & 6 Sqm Wire Complete In All Respect. Job Including Making Of Star Delta Starter Provision In Panel (3 Nos). , Dismantling Of Old Panel, Structure, Damaged Components And Installation Of New Panel At Site By Making Foundation, Termination Of Cable Both Incoming And Outgoing Side, Including Cable Connections. This Includes Cartage ,Loading And Unloading By Crane Or Heavy Labour Etc. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia. G.I. Pipe From Earth Electrode Including Connection With G.I. Nut Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow :- I) Continuity And Earth Testing Ii) Meggaring Of All Equipments For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. Iii) Checking For All Tightness Of Nut And Bolts. Iv) Alignments Of Doors Etc. V) Interlocking Tests. Vi) All Function Tests.

BOQ

Name of Work:- Replacement of very old and damaged LT Panel and allied works at Pkt-1 and 2 DDA Flat BPS Jasola Vihar in Okhla Constituency AC-54.
Sl. No. Item Description
1LT Distribution panel sheet steel enclosure made out of 2 mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminium. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 mm cross section. Each wire will be terminating with a ferule crimped to the wire. The panel size must be of 2000MM X 2000MM X 450MM. mounted on MS angle having 4 legs of 1 feet height.
2MCCB 250 Amp. 4 Pole 3phase High breaking capacity 50KA 50Hz, 430V with spreader& Handle Make : L&T/Siemens/Schneider/Havells/DJB approved make..
3MCCB 125 Amp. 4 Pole 3phase High breaking capacity 50KA 50Hz, 430V with spreader & Handle. Make : L&T/Siemens/Schneider/Havells/DJB approved make..
4MCCB 415V, 4 Pole, 3 phase 50KA 50Hz, 63 Amp with spreader & handle. Make : L&T/Siemens/Schneider/Havells/DJB approved make..
5MCB Single pole 6 Amp. Make:- L&T/Havells/Schneider/ DJB approved
6MCB Triple pole 32 Amp. Make :-L&T/Havells/ DJB approved
7MCB Triple pole 63 Amp. Make:- L&T/Havells/ DJB approved
8Power capacitors(Heavy Duty) 415V unit of 20 Kvar Make:- Havells /L&T/ DJB approved
9Shunt Power capacitors(Heavy Duty) 415V unit of 5 Kvar Make :- Havells /L&T/ DJB approved
10Over load relay 42-69 Amp Make:-L&T/Siemens/ DJB approved
11Over load relay 14-23 Amp Make:- L&T/Siemens DJB approved
12Over load relay 6-9 Amp Make:- L&T/Siemens DJB approved
13Digital Amp. Meter Make AE/L&T/ DJB approved
14Digital Volt Meter 0-500V .Make:- AE/L&T/ DJB approved
15Motor protection/Phase failure Relay Make:- L&T/Siemens/ DJB approved
16Power contactor 220V 3phase 70 Amp. Make:- L&T/Siemens/ DJB approved
17Power contactor 220V 3phase 50 Amp. Make:-L&T/Siemens/DJB approved
18Power contactor 220V 3phase 40 Amp. Make:- L&T/Siemens/ DJB approved
19Power contactor 220V 3phase 25 Amp. Make:- L&T/Siemens/ DJB approved
20Star delta timer on delay. make:- L&T/Siemens/ DJB approved
21Indicating lights LED type RYB & On/OFF Make:-L&T/Havells/ DJB approved
22Supply of ON / OFF Push Button. make:- L&T/Havells/ DJB approved
23Current Transformer 200/5, 100/5 & 30/5. Make:- AE /Advance/ DJB approved
24On load change over switch 250 Amp. 415V, Open execution type Make:- L&T/Havells/C&S/ DJB approved
25Supply of 95 sq mm x 3.5 core aluminium armoured cable . Make: Grandlay/Havells/DJB approved
26Supply of flexible Copper cable 35 sq mm single core. Make: Grandlay/Havells/DJB approved
27Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares, control wiring in 1.5 sq. mm, 2.5 sq.mm , 4.00 sq.mm & 6 sqm wire complete in all respect. Job including making of star delta starter provision in panel (3 Nos).
28Dismantling of old panel, structure, damaged components and installation of new panel at site by making foundation, termination of cable both incoming and outgoing side, including cable connections. This includes cartage ,loading and unloading by crane or heavy labour etc.
29Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia. G.I. pipe from earth electrode including connection with G.I. nut bolt, spring, washer excavation and re-filling etc. as required.
30Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
31Testing & commissioning of panel, as per required parameters with relevant IS. Testing of the panel prior to switching on as follow :- i) Continuity and earth testing ii) Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth.iii) Checking for all tightness of nut and bolts.iv) Alignments of doors etc.v) Interlocking tests. vi) All function tests. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57273754
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 07-09-2026
Authority
Authority Name Delhi Jal Board
Work Description Tender for Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-1 And 2 Dda Flat Bps Jasola Vihar In Okhla Constituency Ac-54. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2 Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminium. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5 Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire. The Panel Size Must Be Of 2000Mm X 2000Mm X 450Mm. Mounted On Ms Angle Having 4 Legs Of 1 Feet Height. , Mccb 250 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader& Handle Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mccb 125 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mccb 415V, 4 Pole, 3 Phase 50Ka 50Hz, 63 annual periodical maintenance With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mcb Single Pole 6 Amp. Make:- L&T/Havells/Schneider/ Djb Approved , Mcb Triple Pole 32 Amp. Make :-L&T/Havells/ Djb Approved , Mcb Triple Pole 63 Amp. Make:- L&T/Havells/ Djb Approved , Power Capacitors(Heavy Duty) 415V Unit Of 20 Kvar Make:- Havells /L&T/ Djb Approved , Shunt Power Capacitors(Heavy Duty) 415V Unit Of 5 Kvar Make :- Havells /L&T/ Djb Approved , Over Load Relay 42-69 annual periodical maintenance Make:-L&T/Siemens/ Djb Approved , Over Load Relay 14-23 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Over Load Relay 6-9 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Digital Amp. Meter Make Ae/L&T/ Djb Approved , Digital Volt Meter 0-500V .Make:- Ae/L&T/ Djb Approved , Motor Protection/Phase Failure Relay Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 70 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 50 Amp. Make:-L&T/Siemens/Djb Approved , Power Contactor 220V 3Phase 40 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 25 Amp. Make:- L&T/Siemens/ Djb Approved , Star Delta Timer On Delay. Make:- L&T/Siemens/ Djb Approved , Indicating Lights Led Type Ryb & On/Off Make:-L&T/Havells/ Djb Approved , Supply Of On / Off Push Button. Make:- L&T/Havells/ Djb Approved , Current Transformer 200/5, 100/5 & 30/5. Make:- Ae /Advance/ Djb Approved , On Load Change Over Switch 250 Amp. 415V, Open Execution Type Make:- L&T/Havells/C&S/ Djb Approved , Supply Of 95 Sq Mm X 3.5 Core Aluminium Armoured Cable . Make: Grandlay/Havells/Djb Approved , Supply Of Flexible Copper Cable 35 Sq Mm Single Core. Make: Grandlay/Havells/Djb Approved , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares, Control Wiring In 1.5 Sq. Mm, 2.5 Sq.Mm , 4.00 Sq.Mm & 6 Sqm Wire Complete In All Respect. Job Including Making Of Star Delta Starter Provision In Panel (3 Nos). , Dismantling Of Old Panel, Structure, Damaged Components And Installation Of New Panel At Site By Making Foundation, Termination Of Cable Both Incoming And Outgoing Side, Including Cable Connections. This Includes Cartage ,Loading And Unloading By Crane Or Heavy Labour Etc. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia. G.I. Pipe From Earth Electrode Including Connection With G.I. Nut Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow :- I) Continuity And Earth Testing Ii) Meggaring Of All Equipments For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. Iii) Checking For All Tightness Of Nut And Bolts. Iv) Alignments Of Doors Etc. V) Interlocking Tests. Vi) All Function Tests.
Basic Detail
Tender No NIT No. 20/EE(EM)M-11/(26-27)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 31 Aug 2026
Submission Date 07 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 12300
Exemption Available
Document List
41dcf760-f744-4822-bfc6-8b788c684c88.html
BOQ_396768.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

41dcf760-f744-4822-bfc6-8b788c684c88.html

xls

BOQ_396768.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders