Railways Government Departments Closing in 4 days TDR #57271488

Supply Of Supply Installation Testing And commissioning of 125KVA at 0.8 pf 415V 50 Hz 3 phase CPCB IV+ DG Set complete with 1500 RPM DieselEngine of suitable BHP & AC Brush less Alternator mounted on a common base Frame & coupled through a flexible

Issued by Government Departments · Guntakal, Andhra Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Sep 2026
4 days left
EMD
26850
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Guntakal → Andhra Pradesh
EMD Exemption
Not Available
Quantity
1

Project Description

Supply Of supply installation testing and commissioning of 125kva at 0.8 pf 415v 50 hz 3 phase cpcb iv+ dg set complete with 1500 rpm dieselengine of suitable bhp & ac brush less alternator mounted on a common base frame & coupled through a flexible coupling or close coupled. , supply installation testing and commissioning of 125kva at 0.8 pf 415v 50 hz 3 phase cpcb iv+ dg set complete with 1500 rpm diesel engine of suitable bhp & ac brush less alternator mounted on a common base frame & coupled through a flexible coupling or close coupled. alternator 1. 1500 rpm, 1p or 3p, brushless type, screen protected , revolving field, self-excited alternator conforming to is/iec 60034-1 ip23, with standard alternator protection (over volt age, over speed & under voltage) 2. a reliable long life with superior class h insulation with temperature rise to class h diesel engine: engine: engine should comprise of silencer, electronic governor from >25 kva & above, suitable rating battery , battery charging alternator, battery charger , inbuilt fuel tank with fuel pipe, avm pads , control panel with 3p mccb of suitable rating with short circuit protections (25ka,36ka, 50ka) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, kwh, kvar, hrs etc.), the diesel engine shall be capable of providing 10% overload for 1 hr for every 11 hrs of continuous running at full load. the dg set shall be supplied as per oem specifications and s hall be tested at site along with below. 1. crdi engine >25 kva dg set 2. water cooled radiator coupled to engine 3. dr y type air cleaner with service indicator 4. first fill of lube oil, coolant & first fill of diesel 5. electrical starter motor with soft start system 6. battery charging alternator 7. remote monitor system >58.5 kva & above 8. 2 years / 5000 hrs wa rranty from commissioning or 30-month form supply. 9. emission control system - egr & (doc, scr for >75 kva dg set ) 10.10 mtrs exhaust pipe from silencer genset controller: 1. microprocessor based genset monitoring, metering and co ntrol system with full graphics lcd display for easy front panel access. 2. amf relay, manual and remote start / stop mo des for 1-ph & 3-ph gensets 3. backlit and full graphics display with power saving feature 4. engine parameter monitori ng -lube oil pressure, engine coolant temperature, fuel level, battery voltage, engine running hours 5. ac alternator pa rameter monitoring -voltage l-n & l_l, current, kw, kva (phase & total), frequency, kwh, pf 6. genset protection: engi ne: low lube oil pressure, high coolant temperature, battery high/low volts, fail to start, sensor failure, low fuel level, overspeed ac alternator: over/under voltage, over/under, frequency, loss of ac sensing, over frequency, over curren t, kw overload, unbalancing load 7. maintenance notification based on engine run hour & due date 8.communication: usb port, rs485, can 9.30-50 event logs acoustic enclosure: 1. specially designed to meet stringent moef/cpcb iv+ n orms 2. weatherproof, powder coated acoustic enclosure for dg set for sound attenuation fabricated from 1.2 mm / 1.6 mm crca sheet steel (structure) with side wall fabricated from 1.2mm /1.6 mm crca sheet and filled with pu foam/roc kwood for fire retardant acoustic and for better safety 3. designed to operate in extreme climatic conditions in tempera tures ranging from -10 deg to 55 deg without any external aid 4. fabricated base frame with avm pads. 5. noise level is less than 75 db (a) at a distance of 1 mtrs as per latest cpcb norms, complete in all respect. description of stage - 1 ins pection: rites (as 100% of poqty.) ]

AI Tender Summary

OUR REF NO 57271488
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 15-09-2026
Authority
Authority Name South Central Railway
Work Description Supply Of supply installation testing and commissioning of 125kva at 0.8 pf 415v 50 hz 3 phase cpcb iv+ dg set complete with 1500 rpm dieselengine of suitable bhp & ac brush less alternator mounted on a common base frame & coupled through a flexible coupling or close coupled. , supply installation testing and commissioning of 125kva at 0.8 pf 415v 50 hz 3 phase cpcb iv+ dg set complete with 1500 rpm diesel engine of suitable bhp & ac brush less alternator mounted on a common base frame & coupled through a flexible coupling or close coupled. alternator 1. 1500 rpm, 1p or 3p, brushless type, screen protected , revolving field, self-excited alternator conforming to is/iec 60034-1 ip23, with standard alternator protection (over volt age, over speed & under voltage) 2. a reliable long life with superior class h insulation with temperature rise to class h diesel engine: engine: engine should comprise of silencer, electronic governor from >25 kva & above, suitable rating battery , battery charging alternator, battery charger , inbuilt fuel tank with fuel pipe, avm pads , control panel with 3p mccb of suitable rating with short circuit protections (25ka,36ka, 50ka) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, kwh, kvar, hrs etc.), the diesel engine shall be capable of providing 10% overload for 1 hr for every 11 hrs of continuous running at full load. the dg set shall be supplied as per oem specifications and s hall be tested at site along with below. 1. crdi engine >25 kva dg set 2. water cooled radiator coupled to engine 3. dr y type air cleaner with service indicator 4. first fill of lube oil, coolant & first fill of diesel 5. electrical starter motor with soft start system 6. battery charging alternator 7. remote monitor system >58.5 kva & above 8. 2 years / 5000 hrs wa rranty from commissioning or 30-month form supply. 9. emission control system - egr & (doc, scr for >75 kva dg set ) 10.10 mtrs exhaust pipe from silencer genset controller: 1. microprocessor based genset monitoring, metering and co ntrol system with full graphics lcd display for easy front panel access. 2. amf relay, manual and remote start / stop mo des for 1-ph & 3-ph gensets 3. backlit and full graphics display with power saving feature 4. engine parameter monitori ng -lube oil pressure, engine coolant temperature, fuel level, battery voltage, engine running hours 5. ac alternator pa rameter monitoring -voltage l-n & l_l, current, kw, kva (phase & total), frequency, kwh, pf 6. genset protection: engi ne: low lube oil pressure, high coolant temperature, battery high/low volts, fail to start, sensor failure, low fuel level, overspeed ac alternator: over/under voltage, over/under, frequency, loss of ac sensing, over frequency, over curren t, kw overload, unbalancing load 7. maintenance notification based on engine run hour & due date 8.communication: usb port, rs485, can 9.30-50 event logs acoustic enclosure: 1. specially designed to meet stringent moef/cpcb iv+ n orms 2. weatherproof, powder coated acoustic enclosure for dg set for sound attenuation fabricated from 1.2 mm / 1.6 mm crca sheet steel (structure) with side wall fabricated from 1.2mm /1.6 mm crca sheet and filled with pu foam/roc kwood for fire retardant acoustic and for better safety 3. designed to operate in extreme climatic conditions in tempera tures ranging from -10 deg to 55 deg without any external aid 4. fabricated base frame with avm pads. 5. noise level is less than 75 db (a) at a distance of 1 mtrs as per latest cpcb norms, complete in all respect. description of stage - 1 ins pection: rites (as 100% of poqty.) ]
Basic Detail
Tender No LV265467A
Bidding Type Tender
Location
City Guntakal
State Andhra Pradesh
Key Dates
Publish Date 31 Aug 2026
Submission Date 15 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 26850
Exemption Not Available
Document List
5889014.pdf
5889015.pdf
5889018.pdf
de904d75-320a-46ef-9ac8-7fc4b73cabd9.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

5889014.pdf

pdf

5889015.pdf

pdf

5889018.pdf

pdf

de904d75-320a-46ef-9ac8-7fc4b73cabd9.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders