Tender For Repairs To Internal Structural Strengthening To Old & New Building Of Gst Bhavan @ Mazgoan, Mumbai. (Repairs To Reinforced Cement Concrete Ceiling, Beam, Column, Flooring, Toilet Block, All Section Window, Furniture Internally Plumbing Wit
Tender Overview
Project Description
Tender for Repairs To Internal Structural Strengthening To Old & New Building Of Gst Bhavan @ Mazgoan, Mumbai. (Repairs To Reinforced Cement Concrete Ceiling, Beam, Column, Flooring, Toilet Block, All Section Window, Furniture Internally Plumbing With Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 2 | Breaking/ Chipping carefully the loose concrete / plaster of distressed member without damaging existing strong concrete by means of sharp chissle which should tempered regularly or high frequency low impact hammers used, cleaning the surface by water jet pressure pump at 4 to 5 kg/ sqcm pressure to remove chlorides and loose particles, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damaged area of member / concrete will be measured) etc complete. |
| 3 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 4 | Removing Existing Expension Joints System including removel of all metal parts, chemicals, sealants with least possible damage to the adjucent area and surface perpetiton such as joints shall be free from loose/flaky particals, oil dust etc. The joints surface shall be cleaned with wire brush and cleaned by blower etc. complete. (Horizontal & Vertical) |
| 5 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/ quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 7 | Drilling 14 mm diameter hole in concrete at required locations and level, cleaning and anchoring the rebar reinforcement as per manufactures specifications etc. complete and as directed by Engineer in charge. (Excluding Cost of reinforcement bar) |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 10 | Providing and grouting the holes by Poly Ceramic Cementitious i.e Nic Grout G 06 + 53 grade cement material of Dimple Chemicals as per requirement to reduce the porosity of concrete / Masonry structure and to increase the strength of structure using grouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge. |
| 11 | Injecting approved low viscous epoxy grout into concrete slab, stone masonry cracks, columns etc. by suitable gun/ pump (using Araldite GY-257 & Aradur -21 in 1:0.21 prop.) at required pressures by providing necessary scaffolding, drilling and inserting 12mm dia.Brass grouting multiperforated nipples upto 30mm to 40mm depth, using M Seal,Quartz sand around the nipple, cutting of nipples after curing, cleaning etc. complete. (This item shall be paid on actual consumption of epoxy used in Kgs.) |
| 12 | Repair with Microconcrete: Providing, mixing and placing 100 mm thick encasement with free flow high performance micro-concrete as per technical specification. (Note :- This rate is for 100 mm thickness during execution, if thickness is reduced rate to be reduced accordingly) |
| 13 | Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another enoate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate.(If scaffolding is required, same shall be provided and will be paid under relevant item) (Upto 15 mm thickness at a time). |
| 14 | Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another innovate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, formaldehyde based polymer with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item) (15-30 mm thickness at a time). |
| 15 | Shear Connectors: Make 10/12 mm dia holes using heavy duty lectrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars. |
| 16 | Carbon Fiber Wrapping System : Providing & laying applying carbon Fiber sheet wrap at structural members including Surface Preparation: Grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete. Profiling: Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc., complete. Wrapping : Wrapping the Glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., Repeat the same procedure for multiple layer with interval of 8 hours. Sand Pasting: Applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes. (Mode of Measurement: Per Sq.Mt of Fiber consume and not application of surface area.) |
| 17 | Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) |
| 18 | Providing and erecting steel tubular props of required height upto 14' feet, L head or flat head braced at center and supporting a continuous 2\\" x 3\\" wooden runner, resting on wedge and block minimum capacity 3 Ton to support the structure provisionally during repair and jacketing etc. and maintaining them in position till all required item are complete. The props are erected in perfect vertical in plumb taking / transferring the load equally / uniformly. The location of every prop should be one over another floor and it should not be eccentric. The tightening of every prop should be uniform to all props to strain the building uniformly, removing the same as and when directed by structural engineer / Site Engineer. The work should be carried out with all the safety measures like helmet, safety belt and adequate labor insurance under the supervision of qualified supervisor and remove the same completion of work etc. complete. |
| 19 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. complete |
| 20 | Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. |
| 21 | Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. |
| 22 | Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. |
| 23 | Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed. |
| 24 | Supply of HDPE Tarpoline (GSM of 268+or-8) as per approved sample by the Engineer in charge with all lead and lift etc. |
| 25 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. |
| 26 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. |
| 27 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. |
| 28 | Removing cement tiles, or marble of polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 29 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. |
| 30 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 31 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. |
| 32 | Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 33 | Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete. One side polish |
| 34 | Providing and laying telephone black / Amba White / Cadbury brown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc.complete. |
| 35 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) |
| 36 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 37 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer incharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box |
| 38 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. |
| 39 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete. |
| 40 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 41 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 42 | Providing and fixing orissa type colour glazed earthenware 625 x 450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100 mm. dia. C.I. plug, bend, 15mm. thick 10 litre PVC flushing cistern with all necessary pipe connection etc. complete. |
| 43 | Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. |
| 44 | Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. |
| 45 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 46 | Providing and fixing of approved make white aquafree Waterless Urinal of with cartride size of 31.5x33x60cm including other necessary fittings etc. complete. |
| 47 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super bib tap with flange including all accessories etc complete |
| 48 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 49 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend, connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) |
| 50 | Providing and applying gypsum plaster (with Gypsum material of Gypsum India / Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 51 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean. Applying Asian / Berger / Nerolac / Dulux Paints or equivalent wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. Applying Asian / Berger / Nerolac / Dulux Paints or equivalent Acrylic wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying Asian / Berger / Nerolac / Dulux Paints or equivalent wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, Applying Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat of Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) |
| 52 | Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete. |
| 53 | Providing and fixing 6 mm thick commercial plywood with jungle wood frame work of 50 x 35 mm size at 60 cm on both ways for closing the window portion/openings for protection from falling debris, dust etc. including cutting, fixing with nails and removing after the same after completion of the work. (To be used after approval of Superintending Engineer) |
| 54 | Removing any kind of debris including loading in truck and conveying to dumping point approved by MCGM, unloading, spreading etc. complete. With all leads and lifts. |
| 55 | Supplying Skilled Labour for day to day transport for exesting furniture during the execution of Work & also for Misc. Work. |
| 56 | Providing and applying two coat of Fibre Reinforced Liquid Applied membrane of Asian paints or equivalent make, having, track bridging ability up to 2mm, superior anti carbonation with life of 10 years ensuring forced coverage of 160 microns, applying one coat of thick acrylic base texture (2.0 mm to 2.5 mm thick), and after 8 hours applying two coats of organo licon with VOC (Volatile organic compound) less than 30 grame per litre, UV cross Linking Emulsion having advance anti regal, Excellent DPUR for dirt pick up Resistance, (Colour stay) resistance to fading of colours, protection against bird dropping and paint performance warranty for 15 years on requisite stamp paper so as to obtain an acceptable finish and during minimum 40 microns thickness for two coat, as directed by engineer-in-charge. |
| 57 | Providing and fixing construction three layer monofilament safety net including first layer of machine knotted 5mm braided Rope with 100 mm x 100 mm mesh size, second layer of machine knotted 2.5 mm braided rope with 25 mm x 25mm mesh size, third layer of monofilament stabilizer and net with welding / grinding splatter resistance, border rope of 12 mm maximum including the cord of 12 mm maximum at tower corners at 1.50 meter long at every 1.50 meter distance including require size and as per specification and certification approved including testing criteria for safety net EN1263-1 including drop test (dynamic test) and energy absorption test (En-1263-1:2002) and as per instructions and approved of the Engineer - In - Charge (Horizontal Safety Net) |
| 58 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 59 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 60 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 61 | Providing internal cement plaster 20mm thick in a single coat using Ready to use wall plaster to concrete, brick surfaces in all positions including scaffolding and curing. Providing groove at joint of B.B.Masonry and concrete members complete C ) cement mortar 1:3 With Prior Approval of Concerned S.E. |
| 62 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. |
| 63 | Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. |
| 64 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 65 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 66 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 67 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 68 | Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. |
| 69 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 70 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 71 | Supplying and erecting ISI mark modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete |
| 72 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 73 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 74 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 1 module complete duly erected. |
| 75 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 3 module complete duly erected. |
| 76 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 6 module complete duly erected. |
| 77 | Supplying and erecting PVC Surface modular switch box with doublemounting & front plate for 8 module complete duly connected. |
| 78 | Supplying and erecting PVC Surface modular switch box with doublemounting & front plate for 16/18 module complete duly connected. |
| 79 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 80 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 81 | Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 moduleof modular switch in provided box complete & duly concealed with necessary material and connected. |
| 82 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 83 | Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW |
| 84 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm(2+1E) FRLSH grade copper wire, modular type switch, earthing andrequired accessories as per specification No: WG-PW/SW |
| 85 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 86 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with highdensity polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 87 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 88 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 89 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 90 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min.1.5mm thick MS sheet as per specification no. WG-TW |
| 91 | Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK |
| 92 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty |
| 93 | Supplying and erecting ding dong / electronic musical type call bell withheavy duty coil suitable to operate on 230V A.C. supply erected on polisheddouble wooden block/sunmica block of suitable size. |
| 94 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200mm complete erected in position as per specification no. FG-FN/CF |
| 95 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 96 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 97 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 98 | Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 99 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 100 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 101 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I.Clamps fixed on wall/cable/ conduit with screws in an approved manner. |
| 102 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware. |
| 103 | Dismantling the existing switchgears, DB, and bus bar of any size completewith/ without board or angle iron frame |
| 104 | Dismantling of existing fluorescent fittings of any type & size. |
| 105 | Dismantling the existing ceiling fan /exhaust fan / cabin fan / bracket fancomplete with accessories, G.I. down rod, frame etc. and making the site clear. |
| 106 | Dismantling the existing light, fan, bell, clock, independent plug point,wiring including circuit mains of all types along with accessories etc.complete as per specification No: WG-DM/PW |
| 107 | Dismantling the existing cables of all types & size up to 10 sq mm. |
| 108 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 109 | Supplying,installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM CSR 22-23 (13-10-12 ) |
| 110 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.CSR 22-23 (13-10-9 ) |
| 111 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty . FF- AFAS/SSH. CSR 22-23 ( 13-10-13) |
| 112 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mmconforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP CSR 22-23 ( 13-10-5) |
| 113 | Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP |
| 114 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU CSR 22-23 ( 13-9-10 ) |
| 115 | Supplying, erecting, testing and commissioning amplifier 120 Wfor public address system suitable to operate on230Volts A.C. /12 Volts D.C. supply complete asperspecification no. FFPA/AFR |
| 116 | Supplying, erecting, testing and commissioning microphone complete as per specification no. FF-PA/MIC |
| 117 | Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating/powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete. |
| 118 | Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender